-
Machine learning-assisted techniques for Compton-background discrimination in Broad Energy Germanium (BEGe) detector
Authors:
Giovanni Baccolo,
Andrea Barresi,
Davide Chiesa,
Andrea Giachero,
Danilo Labranca,
Roberto Moretti,
Massimiliano Nastasi,
Alessandro Paonessa,
Marco Picione,
Ezio Previtali,
Monica Sisti
Abstract:
High Purity Germanium (HPGe) detectors are powerful detectors for gamma-ray spectroscopy. The sensitivity to low-intensity gamma-ray peaks is often hindered by the presence of Compton continuum distributions, originated by gamma-rays emitted at higher energies. This study explores novel, pulse shape-based, machine learning-assisted techniques to enhance Compton background discrimination in Broad E…
▽ More
High Purity Germanium (HPGe) detectors are powerful detectors for gamma-ray spectroscopy. The sensitivity to low-intensity gamma-ray peaks is often hindered by the presence of Compton continuum distributions, originated by gamma-rays emitted at higher energies. This study explores novel, pulse shape-based, machine learning-assisted techniques to enhance Compton background discrimination in Broad Energy Germanium (BEGe TM) detectors. We introduce two machine learning models: an autoencoder-MLP (Multilayer Perceptron) and a Gaussian Mixture Model (GMM). These models differentiate single-site events (SSEs) from multi-site events (MSEs) and train on signal waveforms produced in the detector. The GMM method differs from previous machine learning efforts in that it is fully unsupervised, hence not requiring specific data labelling during the training phase. Being both label-free and simulation-agnostic makes the unsupervised approach particularly advantageous for tasks where realistic, high-fidelity labeling is challenging or where biases introduced by simulated data must be avoided. In our analysis, the full-energy Peak-to-Compton ratio of the 137-Cs, a radionuclide contained in a cryoconite sample, exhibits an improvement from 0.238 in the original spectrum to 0.547 after the ACM data filtering and 0.414 after the GMM data filtering, demonstrating the effectiveness of these methods. The results also showcase an enhancement in the signal-to-background ratio across many regions of interest, enabling the detection of lower concentrations of radionuclides.
△ Less
Submitted 11 December, 2024;
originally announced December 2024.
-
Radiopurity screening of materials for rare event searches by neutron activation at the TRIGA reactor of Pavia
Authors:
G. Baccolo,
A. Barresi,
D. Chiesa,
M. Nastasi,
E. Previtali,
M. Sisti
Abstract:
In the framework of physics experiments searching for rare events, the selection of extremely radiopure materials is a challenging task, as the signal of interest is often hidden by instrumental background. Neutron activation is a powerful technique to measure trace contaminants with high sensitivity but, to be properly applied, it requires a good characterization of neutron irradiation and $γ$-sp…
▽ More
In the framework of physics experiments searching for rare events, the selection of extremely radiopure materials is a challenging task, as the signal of interest is often hidden by instrumental background. Neutron activation is a powerful technique to measure trace contaminants with high sensitivity but, to be properly applied, it requires a good characterization of neutron irradiation and $γ$-spectroscopy facilities. This paper presents the state-of-the-art workflow adopted by the Radioactivity Laboratory of the University of Milano-Bicocca for radiopurity screening of materials by neutron activation performed at the TRIGA reactor in Pavia. The ultimate sensitivity of the described workflow, in the absence of interfering activation products and without the application of radiochemical and/or active background rejection techniques, is $<10^{-14}$ g/g for $^{40}$K, $<10^{-12}$ g/g for $^{238}$U and of the order of $10^{-12}$ g/g for $^{232}$Th contaminations. Further details are here provided to address systematic uncertainties related to neutron irradiation that may bias results. To this aim, a dedicated neutron activation campaign was performed and the data were analyzed exploiting a Monte Carlo simulation model of the reactor and applying an unfolding technique to obtain a comprehensive characterization of the neutron flux in typical irradiation configurations. The results of this work provide a valuable benchmark for the application of neutron activation in future radiopurity screening campaigns.
△ Less
Submitted 4 November, 2024;
originally announced November 2024.
-
Improving radioactive contaminant identification through the analysis of delayed coincidences with an $α$-spectrometer
Authors:
G. Baccolo,
A. Barresi,
M. Beretta,
D. Chiesa,
M. Nastasi,
L. Pagnanini,
S. Pozzi,
E. Previtali,
M. Sisti,
G. Terragni
Abstract:
In the framework of rare event searches, the identification of radioactive contaminants in ultra-pure samples is a challenging task, because the signal is often at the same level of the instrumental background. This is a rather common situation for $α$-spectrometers and other detectors used for low-activity measurements. In order to obtain the target sensitivity without extending the data taking l…
▽ More
In the framework of rare event searches, the identification of radioactive contaminants in ultra-pure samples is a challenging task, because the signal is often at the same level of the instrumental background. This is a rather common situation for $α$-spectrometers and other detectors used for low-activity measurements. In order to obtain the target sensitivity without extending the data taking live-time, analysis strategies that highlight the presence of the signal sought should be developed. In this paper, we show how to improve the contaminant tagging capability relying on the time-correlation of radioactive decay sequences. We validate the proposed technique by measuring the impurity level of both contaminated and ultra-pure copper samples, demonstrating the potential of this analysis tool in disentangling different background sources and providing an effective way to mitigate their impact in rare event searches.
△ Less
Submitted 9 November, 2021; v1 submitted 7 May, 2021;
originally announced May 2021.
-
FAMU: study of the energy dependent transfer rate $Λ_{μp \rightarrow μO}$
Authors:
FAMU Collaboration,
E. Mocchiutti,
V. Bonvicini,
M. Danailov,
E. Furlanetto,
K. S. Gadedjisso-Tossou,
D. Guffanti,
C. Pizzolotto,
A. Rachevski,
L. Stoychev,
E. Vallazza,
G. Zampa,
J. Niemela,
K. Ishida,
A. Adamczak,
G. Baccolo,
R. Benocci,
R. Bertoni,
M. Bonesini,
F. Chignoli,
M. Clemenza,
A. Curioni,
V. Maggi,
R. Mazza,
M. Moretti
, et al. (31 additional authors not shown)
Abstract:
The main goal of the FAMU experiment is the measurement of the hyperfine splitting (hfs) in the 1S state of muonic hydrogen $ΔE_{hfs}(μ^-p)1S$. The physical process behind this experiment is the following: $μp$ are formed in a mixture of hydrogen and a higher-Z gas. When absorbing a photon at resonance-energy $ΔE_{hfs}\approx0.182$~eV, in subsequent collisions with the surrounding $H_2$ molecules,…
▽ More
The main goal of the FAMU experiment is the measurement of the hyperfine splitting (hfs) in the 1S state of muonic hydrogen $ΔE_{hfs}(μ^-p)1S$. The physical process behind this experiment is the following: $μp$ are formed in a mixture of hydrogen and a higher-Z gas. When absorbing a photon at resonance-energy $ΔE_{hfs}\approx0.182$~eV, in subsequent collisions with the surrounding $H_2$ molecules, the $μp$ is quickly de-excited and accelerated by $\sim2/3$ of the excitation energy. The observable is the time distribution of the K-lines X-rays emitted from the $μZ$ formed by muon transfer $(μp) +Z \rightarrow (μZ)^*+p$, a reaction whose rate depends on the $μp$ kinetic energy. The maximal response, to the tuned laser wavelength, of the time distribution of X-ray from K-lines of the $(μZ)^*$ cascade indicate the resonance. During the preparatory phase of the FAMU experiment, several measurements have been performed both to validate the methodology and to prepare the best configuration of target and detectors for the spectroscopic measurement. We present here the crucial study of the energy dependence of the transfer rate from muonic hydrogen to oxygen ($Λ_{μp \rightarrow μO}$), precisely measured for the first time.
△ Less
Submitted 22 January, 2019; v1 submitted 20 August, 2018;
originally announced August 2018.
-
First FAMU observation of muon transfer from mu-p atoms to higher-Z elements
Authors:
FAMU Collaboration,
Emiliano Mocchiutti,
Valter Bonvicini,
Rita Carbone,
Miltcho Danailov,
Elena Furlanetto,
Komlan Segbeya Gadedjisso-Tossou,
Daniele Guffanti,
Cecilia Pizzolotto,
Alexandre Rachevski,
Lyubomir Stoychev,
Erik Silvio Vallazza,
Gianluigi Zampa,
Joseph Niemela,
Katsuhiko Ishida,
Andrzej Adamczak,
Giovanni Baccolo,
Roberto Benocci,
Roberto Bertoni,
Maurizio Bonesini,
Francesco Chignoli,
Massimiliano Clemenza,
Alessandro Curioni,
Valter Maggi,
Roberto Mazza
, et al. (32 additional authors not shown)
Abstract:
The FAMU experiment aims to accurately measure the hyperfine splitting of the ground state of the muonic hydrogen atom. A measurement of the transfer rate of muons from hydrogen to heavier gases is necessary for this purpose. In June 2014, within a preliminary experiment, a pressurized gas-target was exposed to the pulsed low-energy muon beam at the RIKEN RAL muon facility (Rutherford Appleton Lab…
▽ More
The FAMU experiment aims to accurately measure the hyperfine splitting of the ground state of the muonic hydrogen atom. A measurement of the transfer rate of muons from hydrogen to heavier gases is necessary for this purpose. In June 2014, within a preliminary experiment, a pressurized gas-target was exposed to the pulsed low-energy muon beam at the RIKEN RAL muon facility (Rutherford Appleton Laboratory, UK). The main goal of the test was the characterization of both the noise induced by the pulsed beam and the X-ray detectors. The apparatus, to some extent rudimental, has served admirably to this task. Technical results have been published that prove the validity of the choices made and pave the way for the next steps. This paper presents the results of physical relevance of measurements of the muon transfer rate to carbon dioxide, oxygen, and argon from non-thermalized excited mu-p atoms. The analysis methodology and the approach to the systematics errors are useful for the subsequent study of the transfer rate as function of the kinetic energy of the mu-p currently under way.
△ Less
Submitted 15 December, 2017; v1 submitted 10 August, 2017;
originally announced August 2017.
-
Steps towards the hyperfine splitting measurement of the muonic hydrogen ground state: pulsed muon beam and detection system characterization
Authors:
A. Adamczak,
G. Baccolo,
D. Bakalov,
G. Baldazzi,
R. Bertoni,
M. Bonesini,
V. Bonvicini,
R. Campana,
R. Carbone,
T. Cervi,
F. Chignoli,
M. Clemenza,
L. Colace,
A. Curioni,
M. Danailov,
P. Danev,
I. D'Antone,
A. De,
C. De,
M. De,
M. Furini,
F. Fuschino,
K. Gadejisso-Tossou,
D. Guffanti,
A. Iaciofano
, et al. (30 additional authors not shown)
Abstract:
The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the…
▽ More
The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the test were the characterization of the target, the hodoscope and the X-ray detectors. The apparatus consisted of a beam hodoscope and X-rays detectors made with high purity Germanium and Lanthanum Bromide crystals. In this paper the experimental setup is described and the results of the detector characterization are presented.
△ Less
Submitted 21 June, 2016; v1 submitted 6 April, 2016;
originally announced April 2016.
-
JUNO Conceptual Design Report
Authors:
T. Adam,
F. An,
G. An,
Q. An,
N. Anfimov,
V. Antonelli,
G. Baccolo,
M. Baldoncini,
E. Baussan,
M. Bellato,
L. Bezrukov,
D. Bick,
S. Blyth,
S. Boarin,
A. Brigatti,
T. Brugière,
R. Brugnera,
M. Buizza Avanzini,
J. Busto,
A. Cabrera,
H. Cai,
X. Cai,
A. Cammi,
D. Cao,
G. Cao
, et al. (372 additional authors not shown)
Abstract:
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the dete…
▽ More
The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the detection of reactor antineutrinos can resolve the neutrino mass hierarchy at a confidence level of 3-4$σ$, and determine neutrino oscillation parameters $\sin^2θ_{12}$, $Δm^2_{21}$, and $|Δm^2_{ee}|$ to an accuracy of better than 1%. The JUNO detector can be also used to study terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model. The central detector contains 20,000 tons liquid scintillator with an acrylic sphere of 35 m in diameter. $\sim$17,000 508-mm diameter PMTs with high quantum efficiency provide $\sim$75% optical coverage. The current choice of the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of detected photoelectrons per MeV is larger than 1,100 and the energy resolution is expected to be 3% at 1 MeV. The calibration system is designed to deploy multiple sources to cover the entire energy range of reactor antineutrinos, and to achieve a full-volume position coverage inside the detector. The veto system is used for muon detection, muon induced background study and reduction. It consists of a Water Cherenkov detector and a Top Tracker system. The readout system, the detector control system and the offline system insure efficient and stable data acquisition and processing.
△ Less
Submitted 28 September, 2015; v1 submitted 28 August, 2015;
originally announced August 2015.