-
Genetic algorithm as a tool for detection setup optimisation: SiFi-CC case study
Authors:
Jonas Kasper,
Awal Awal,
Ronja Hetzel,
Magdalena Kołodziej,
Katarzyna Rusiecka,
Achim Stahl,
Ming-Liang Wong,
Aleksandra Wrońska
Abstract:
Objective: Proton therapy is a precision-focused cancer treatment where accurate proton beam range monitoring is critical to ensure effective dose delivery. This can be achieved by prompt gamma detection with a Compton camera like the SiFi-CC. This study aims to show the feasibility of optimising the geometry of SiFi-CC Compton camera for verification of dose distribution via prompt gamma detectio…
▽ More
Objective: Proton therapy is a precision-focused cancer treatment where accurate proton beam range monitoring is critical to ensure effective dose delivery. This can be achieved by prompt gamma detection with a Compton camera like the SiFi-CC. This study aims to show the feasibility of optimising the geometry of SiFi-CC Compton camera for verification of dose distribution via prompt gamma detection using a genetic algorithm (GA). Approach: The SiFi-CC key geometric parameters for optimisation with the GA are the source-to-scatterer and scatterer-to-absorber distances, and the module thicknesses. The optimisation process was conducted with a software framework based on the Geant4 toolkit, which included detailed and realistic modelling of gamma interactions, detector response, and further steps such as event selection and image reconstruction. The performance of each individual configuration was evaluated using a fitness function incorporating factors related to gamma detection efficiency and image resolution. Results: The GA-optimised SiFi-CC configuration demonstrated the capability to detect a 5 mm proton beam range shift with a 2 mm resolution using 5e8 protons. The best-performing geometry, with 16 fibre layers in the scatterer, 36 layers in the absorber, source-to-scatterer distance 150 mm and scatterer-to-absorber distance 120 mm, has an imaging sensitivity of 5.58(1)e-5. Significance: This study demonstrates that the SiFi-CC setup, optimised through a GA, can reliably detect clinically relevant proton beam range shifts, improving real-time range verification accuracy in proton therapy. The presented implementation of a GA is a systematic and feasible way of searching for a SiFi-CC geometry that shows the best performance.
△ Less
Submitted 2 July, 2025; v1 submitted 27 November, 2024;
originally announced November 2024.
-
Injection Optimization at Particle Accelerators via Reinforcement Learning: From Simulation to Real-World Application
Authors:
Awal Awal,
Jan Hetzel,
Ralf Gebel,
Jörg Pretz
Abstract:
Optimizing the injection process in particle accelerators is crucial for enhancing beam quality and operational efficiency. This paper presents a framework for utilizing Reinforcement Learning (RL) to optimize the injection process at accelerator facilities. By framing the optimization challenge as an RL problem, we developed an agent capable of dynamically aligning the beam's transverse space wit…
▽ More
Optimizing the injection process in particle accelerators is crucial for enhancing beam quality and operational efficiency. This paper presents a framework for utilizing Reinforcement Learning (RL) to optimize the injection process at accelerator facilities. By framing the optimization challenge as an RL problem, we developed an agent capable of dynamically aligning the beam's transverse space with desired targets. Our methodology leverages the Soft Actor-Critic algorithm, enhanced with domain randomization and dense neural networks, to train the agent in simulated environments with varying dynamics promoting it to learn a generalized robust policy. The agent was evaluated in live runs at the Cooler Synchrotron COSY and it has successfully optimized the beam cross-section reaching human operator level but in notably less time. An empirical study further validated the importance of each architecture component in achieving a robust and generalized optimization strategy. The results demonstrate the potential of RL in automating and improving optimization tasks at particle acceleration facilities.
△ Less
Submitted 19 February, 2025; v1 submitted 18 June, 2024;
originally announced June 2024.
-
Optimization of the injection beam line at the Cooler Synchrotron COSY using Bayesian Optimization
Authors:
A. Awal,
J. Hetzel,
R. Gebel,
V. Kamerdzhiev,
J. Pretz
Abstract:
The complex non-linear processes in multi-dimensional parameter spaces, that are typical for an accelerator, are a natural application for machine learning algorithms. This paper reports on the use of Bayesian optimization for the optimization of the Injection Beam Line (IBL) of the Cooler Synchrotron storage ring COSY at the Forschungszentrum Jülich, Germany. Bayesian optimization is a machine le…
▽ More
The complex non-linear processes in multi-dimensional parameter spaces, that are typical for an accelerator, are a natural application for machine learning algorithms. This paper reports on the use of Bayesian optimization for the optimization of the Injection Beam Line (IBL) of the Cooler Synchrotron storage ring COSY at the Forschungszentrum Jülich, Germany. Bayesian optimization is a machine learning method that optimizes a continuous objective function using limited observations. The IBL is composed of 15 quadrupoles and 28 steerers. The goal is to increase the beam intensity inside the storage ring. The results showed the effectiveness of the Bayesian optimization in achieving better/faster results compared to manual optimization.
△ Less
Submitted 16 March, 2023; v1 submitted 17 February, 2023;
originally announced February 2023.