-
Optically Pumped Polarized $^3$He$^{++}$ Ion Source Development for RHIC/EIC
Authors:
A. Zelenski,
G. Atoian,
E. Beebe,
S. Ikeda,
T. Kanesue,
S. Kondrashev,
J. Maxwell,
R. Milner,
M. Musgrave,
M. Okamura,
A. A. Poblaguev,
D. Raparia,
J. Ritter,
A. Sukhanov,
S. Trabocchi
Abstract:
The proposed polarized $^3$He$^{++}$ acceleration in RHIC and the future Electron-Ion Collider will require about $2\times10^{11}$ ions in the source pulse. A new technique had been proposed for production of high intensity polarized $^3$He$^{++}$ ion beams. It is based on ionization and accumulation of the $^3$He gas (polarized by metastability-exchange optical pumping and in the 5 T high magneti…
▽ More
The proposed polarized $^3$He$^{++}$ acceleration in RHIC and the future Electron-Ion Collider will require about $2\times10^{11}$ ions in the source pulse. A new technique had been proposed for production of high intensity polarized $^3$He$^{++}$ ion beams. It is based on ionization and accumulation of the $^3$He gas (polarized by metastability-exchange optical pumping and in the 5 T high magnetic field) in the existing Electron Beam Ion Source (EBIS). A novel $^3$He cryogenic purification and storage technique was developed to provide the required gas purity. An original gas refill and polarized $^3$He gas injection to the EBIS long drift tubes, (which serves as the storage cell) were developed to ensure polarization preservation. An infrared laser system for optical pumping and polarization measurements in the high 3--5 T field has been developed. The $^3$He polarization 80--85\% (and sufficiently long $\sim30$ min relaxation time) was obtained in the \lq\lq{open}\rq\rq\ cell configuration with refilling valve tube inlet and isolation valve closed. The development of the spin-rotator and $^3$He $^4$He absolute nuclear polarimeter at 6 MeV $^3$He$^{++}$ beam energy is also presented.
△ Less
Submitted 7 July, 2023; v1 submitted 18 March, 2023;
originally announced March 2023.
-
Systematic error analysis in the absolute hydrogen gas jet polarimeter at RHIC
Authors:
A. A. Poblaguev,
A. Zelenski,
G. Atoian,
Y. Makdisi,
J. Ritter
Abstract:
The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam i…
▽ More
The Polarized Atomic Hydrogen Gas Jet Target polarimeter (HJET) is operated at the Relativistic Heavy Ion Collider (RHIC) since 2004 to measure the absolute polarization of each colliding proton beam. Polarimeter detectors and data acquisition were upgraded in 2015 to increase the solid angle, energy range, and to improve the energy and time resolution. These upgrades along with an improved beam intensity and polarization allowed us to greatly reduce the statistical and systematic errors for the proton polarization measurements in RHIC Runs 15 ($E_\text{beam}\!=\!100~\text{GeV}$) and 17 ($255~\text{GeV}$). For a typical 8 hour RHIC store, the measured proton beam average polarization was about $P_\text{beam}\!\sim\!55\pm2.0_\text{stat}\pm0.3_\text{syst}\%$. The elastic $\mathit{pp}$ analyzing power, $A_\text{N}(t)\!\sim\!0.04$, was determined with a precision of about $|δA_\text{N}(t)|\!\sim\!0.0002$ in the momentum transfer squared range $0.001\!<\!-t\!<\!0.020\,\text{GeV}^2$. In this paper we present a detailed systematic error analysis of the polarization measurements at HJET. Perspectives of using the HJET based absolute polarimeters in the future Electron Ion Collider (EIC) will be also discussed.
△ Less
Submitted 15 June, 2020;
originally announced June 2020.
-
Enhanced Polarization of Low Pressure $^3$He through Metastability-Exchange Optical Pumping at High Field
Authors:
J. D. Maxwell,
J. Alessi,
G. Atoian,
E. Beebe,
C. S. Epstein,
R. G. Milner,
M. Musgrave,
A. Pikin,
J. Ritter,
A. Zelenski
Abstract:
We report high steady-state nuclear polarization of 1 torr $^3$He gas nuclei via metastability-exchange optical pumping at magnetic fields above 2 T. The introduction of highly polarized $^3$He gas into Brookhaven's Electron Beam Ion Source would enable a new, polarized $^3$He ion source for use at the Relativistic Heavy Ion Collider and a future Electron-Ion Collider facility. By adapting recent…
▽ More
We report high steady-state nuclear polarization of 1 torr $^3$He gas nuclei via metastability-exchange optical pumping at magnetic fields above 2 T. The introduction of highly polarized $^3$He gas into Brookhaven's Electron Beam Ion Source would enable a new, polarized $^3$He ion source for use at the Relativistic Heavy Ion Collider and a future Electron-Ion Collider facility. By adapting recent developments in high field metastability-exchange optical pumping for higher pressure gas, we have successfully polarized 1 torr $^3$He sealed cells in the EBIS solenoid. Through careful manipulation of the RF discharge parameters, polarizations above 80% were attained at 2, 3 and 4 T, with 89% being reached at 3 T with a 664 s relaxation time.
△ Less
Submitted 11 April, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Design of a 10 picosecond Time of Flight Detector using Avalanche Photodiodes
Authors:
Sebastian White,
Mickey Chiu,
Milind Diwan,
Grigor Atoian,
Vladimir Issakov
Abstract:
We describe a detector for measuring the time of flight of forward protons at the Large Hadron Collider (LHC) up to and beyond the full instantaneous design luminosity of 1034 cm-2 s-1. Our design is based on deep diffused, high gain avalanche photodiodes (APDs) which give a signal of ~6000 e when traversed by 7 Teravolt protons. We observe pulse risetimes of 650 psec and a pulse width of 5 nsec…
▽ More
We describe a detector for measuring the time of flight of forward protons at the Large Hadron Collider (LHC) up to and beyond the full instantaneous design luminosity of 1034 cm-2 s-1. Our design is based on deep diffused, high gain avalanche photodiodes (APDs) which give a signal of ~6000 e when traversed by 7 Teravolt protons. We observe pulse risetimes of 650 psec and a pulse width of 5 nsec and calculate a time resolution of ~10 psec and a maximum count rate of >100 Mhz.
△ Less
Submitted 16 January, 2009;
originally announced January 2009.
-
An Improved Shashlyk Calorimeter
Authors:
G. S. Atoian,
G. I. Britvich,
S. K. Chernichenko,
S. Dhawan,
V. V. Issakov,
O. V. Karavichev,
T. L. Karavicheva,
V. N. Marin,
A. A. Poblaguev,
I. V. Shein,
A. P. Soldatov,
M. E. Zeller
Abstract:
Shashlyk electromagnetic calorimeter modules with an energy resolution of about 3%/sqrt{E (GeV)} for 50-1000 MeV photons has been developed, and a prototype tested. Details of these improved modules, including mechanical construction, selection of wave shifting fibers and photo-detectors, and development of a new scintillator with improved optical and mechanical properties are described. How the…
▽ More
Shashlyk electromagnetic calorimeter modules with an energy resolution of about 3%/sqrt{E (GeV)} for 50-1000 MeV photons has been developed, and a prototype tested. Details of these improved modules, including mechanical construction, selection of wave shifting fibers and photo-detectors, and development of a new scintillator with improved optical and mechanical properties are described. How the modules will perform in a large calorimeter was determined from prototype measurements. The experimentally determined characteristics of the calorimeter prototype show energy resolution of sigma_E/E=(1.96+-0.1)% \oplus (2.74+-0.05)%/sqrt{E}, time resolution of sigma_T = (72+-4)/sqrt{E} \oplus (14+-2)/E (ps), where photon energy E is given in GeV units and \oplus means a quadratic summation. A punch-through inefficiency of photon detection was measured to be ε= 5*10^{-5} (Θ>5 mrad).
△ Less
Submitted 27 September, 2007;
originally announced September 2007.
-
Development of Shashlyk Calorimeter for KOPIO
Authors:
G. S. Atoian,
V. V. Issakov,
O. V. Karavichev,
T. L. Karavicheva,
A. A. Poblaguev,
M. E. Zeller
Abstract:
A Shashlyk calorimeter prototype for the KOPIO experiment has been constructed and experimentally tested. The energy resolution of about 4%/sqrt(E(GeV)) for 0.5-2.0 GeV/c positrons was obtained. Based on this results as well as on the results of special measurements, a Monte-Carlo model of the Shashlyk module response was developed. This model, including the effects of shower evolution, light co…
▽ More
A Shashlyk calorimeter prototype for the KOPIO experiment has been constructed and experimentally tested. The energy resolution of about 4%/sqrt(E(GeV)) for 0.5-2.0 GeV/c positrons was obtained. Based on this results as well as on the results of special measurements, a Monte-Carlo model of the Shashlyk module response was developed. This model, including the effects of shower evolution, light collection in scintillator plates, light attenuation in fibers, quantum efficiency of the photodetector, thresholds and noises in the readout system is consistent with experimental results. Possible improvment of the Shashlyk energy resolution up to 3%/sqrt(E(GeV)), the level required by KOPIO experiment, are discussed.
△ Less
Submitted 10 October, 2003;
originally announced October 2003.