-
Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system
Authors:
nEXO Collaboration,
A. Anker,
P. A. Breur,
B. Mong,
P. Acharya,
A. Amy,
E. Angelico,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
J. P. Brodsky,
S. Bron,
E. Brown,
T. Brunner,
B. Burnell,
E. Caden,
L. Q. Cao,
G. F. Cao,
D. Cesmecioglu,
D. Chernyak
, et al. (116 additional authors not shown)
Abstract:
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC)…
▽ More
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $μ$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.
△ Less
Submitted 24 April, 2025; v1 submitted 21 April, 2025;
originally announced April 2025.
-
A Flexible Data Acquisition System Architecture for the Nab Experiment
Authors:
D. G. Mathews,
H. Acharya,
C. B. Crawford,
M. H. Gervais,
A. P. Jezghani,
M. McCrea,
A. Nelsen,
A. Atencio,
N. Birge,
L. J. Broussard,
J. H. Choi,
F. M. Gonzalez,
H. Li,
N. Macsai,
A. Mendelsohn,
R. R. Mammei,
G. V. Riley,
R. A. Whitehead
Abstract:
The Nab experiment will measure the electron-neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model Physics. Using National Instrument's PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab's specifications, but flexible enough to be adapt…
▽ More
The Nab experiment will measure the electron-neutrino correlation and Fierz interference term in free neutron beta decay to test the Standard Model and probe Beyond the Standard Model Physics. Using National Instrument's PXIe-5171 Reconfigurable Oscilloscope module, we have developed a data acquisition system that is not only capable of meeting Nab's specifications, but flexible enough to be adapted in situ as the experimental environment dictates. The L1 and L2 trigger logic can be reconfigured to optimize the system for coincidence event detection at runtime through configuration files and LabVIEW controls. This system is capable of identifying L1 triggers at at least $1$ MHz, while reading out a peak signal rate of approximately $2$ GB/s. During commissioning, the system ran at a sustained readout rate of $400$ MB/s of signal data originating from roughly $6$ kHz L2 triggers, well within the peak performance of the system.
△ Less
Submitted 24 July, 2024;
originally announced July 2024.
-
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment
Authors:
M. Yvaine,
D. Fairbank,
J. Soderstrom,
C. Taylor,
J. Stanley,
T. Walton,
C. Chambers,
A. Iverson,
W. Fairbank,
S. Al Kharusi,
A. Amy,
E. Angelico,
A. Anker,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (112 additional authors not shown)
Abstract:
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s…
▽ More
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
An integrated online radioassay data storage and analytics tool for nEXO
Authors:
R. H. M. Tsang,
A. Piepke,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao,
D. Cesmecioglu,
C. Chambers,
E. Chambers,
B. Chana,
S. A. Charlebois
, et al. (135 additional authors not shown)
Abstract:
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa…
▽ More
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.
△ Less
Submitted 20 June, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
Characterization of Muon and Electron Beams in the Paul Scherrer Institute PiM1 Channel for the MUSE Experiment
Authors:
E. Cline,
W. Lin,
P. Roy,
P. E. Reimer,
K. E. Mesick,
A. Akmal,
A. Alie,
H. Atac,
A. Atencio,
C. Ayerbe Gayoso,
N. Benmouna,
F. Benmokhtar,
J. C. Bernauer,
W. J. Briscoe,
J. Campbell,
D. Cohen,
E. O. Cohen,
C. Collicott,
K. Deiters,
S. Dogra,
E. Downie,
I. P. Fernando,
A. Flannery,
T. Gautam,
D. Ghosal
, et al. (35 additional authors not shown)
Abstract:
The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the prope…
▽ More
The MUon Scattering Experiment, MUSE, at the Paul Scherrer Institute, Switzerland, investigates the proton charge radius puzzle, lepton universality, and two-photon exchange, via simultaneous measurements of elastic muon-proton and electron-proton scattering. The experiment uses the PiM1 secondary beam channel, which was designed for high precision pion scattering measurements. We review the properties of the beam line established for pions. We discuss the production processes that generate the electron and muon beams, and the simulations of these processes. Simulations of the $π$/$μ$/$e$ beams through the channel using TURTLE and G4beamline are compared. The G4beamline simulation is then compared to several experimental measurements of the channel, including the momentum dispersion at the IFP and target, the shape of the beam spot at the target, and timing measurements that allow the beam momenta to be determined. We conclude that the PiM1 channel can be used for high precision $π$, $μ$, and $e$ scattering.
△ Less
Submitted 15 September, 2021;
originally announced September 2021.
-
Timing Detectors with SiPM read-out for the MUSE Experiment at PSI
Authors:
Tigran Rostomyan,
Ethan Cline,
Ievgen Lavrukhin,
Hamza Atac,
Ariella Atencio,
Jan C. Bernauer,
William J. Briscoe,
Dan Cohen,
Erez O. Cohen,
Cristina Collicott,
Konrad Deiters,
Shraddha Dogra,
Evangeline Downie,
Werner Erni,
Ishara P. Fernando,
Anne Flannery,
Thir Gautam,
Debdeep Ghosal,
Ronald Gilman,
Alexander Golossanov,
Jack Hirschman,
Minjung Kim,
Michael Kohl,
Bernd Krusche,
Lin Li
, et al. (18 additional authors not shown)
Abstract:
The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of three timing detectors using plastic scintillator read out with silicon photomultipliers that have been built for the experiment. The Beam Hodoscope, upstream of…
▽ More
The Muon Scattering Experiment at the Paul Scherrer Institut uses a mixed beam of electrons, muons, and pions, necessitating precise timing to identify the beam particles and reactions they cause. We describe the design and performance of three timing detectors using plastic scintillator read out with silicon photomultipliers that have been built for the experiment. The Beam Hodoscope, upstream of the scattering target, counts the beam flux and precisely times beam particles both to identify species and provide a starting time for time-of-flight measurements. The Beam Monitor, downstream of the scattering target, counts the unscattered beam flux, helps identify background in scattering events, and precisely times beam particles for time-of-flight measurements. The Beam Focus Monitor, mounted on the target ladder under the liquid hydrogen target inside the target vacuum chamber, is used in dedicated runs to sample the beam spot at three points near the target center, where the beam should be focused.
△ Less
Submitted 15 October, 2020; v1 submitted 23 July, 2020;
originally announced July 2020.