-
Towards the Quantum Limits of Phase Retrieval
Authors:
Jacob Trzaska,
Amit Ashok
Abstract:
We consider the problem of determining the spatial phase profile of a single-mode electromagnetic field. Our attention is on input states that are a statistical mixture of displaced and squeezed number states, a superset of Gaussian states. In particular, we derive the quantum Fisher information matrix (QFIM) for estimating the expansion coefficients of the wavefront in an orthonormal basis, findi…
▽ More
We consider the problem of determining the spatial phase profile of a single-mode electromagnetic field. Our attention is on input states that are a statistical mixture of displaced and squeezed number states, a superset of Gaussian states. In particular, we derive the quantum Fisher information matrix (QFIM) for estimating the expansion coefficients of the wavefront in an orthonormal basis, finding that it is diagonal. Moreover, we show that a measurement saturating the QFIM always exists, and point to an adaptive strategy capable of implementing it. We then construct the optimal measurements for three particular states: mixtures of photon number, coherent, and single-mode squeezed vacuum states. Sensitivity of the measurements to nuisance parameters is explored.
△ Less
Submitted 7 July, 2024;
originally announced July 2024.
-
Boosting Resonant Sensing in Fluids: A Surprising Discovery
Authors:
Sri Harsha Paladugu,
Kaustav Roy,
Anuj Ashok,
Bibhas Nayak,
Annapoorni Rangarajan,
Rudra Pratap
Abstract:
Micro-mechanical resonators are widely used in modern sensing technology due to their high quality-factor (Q), enabling sensitive detection of various stimuli. However, the performance of these resonators in fluid environments is limited by significant viscous and acoustic radiation losses that reduce their Q. Here, we present a paradigm-shifting discovery that challenges the conventional wisdom o…
▽ More
Micro-mechanical resonators are widely used in modern sensing technology due to their high quality-factor (Q), enabling sensitive detection of various stimuli. However, the performance of these resonators in fluid environments is limited by significant viscous and acoustic radiation losses that reduce their Q. Here, we present a paradigm-shifting discovery that challenges the conventional wisdom of resonant sensing in fluids. We report an optimal volume of fluid over a 2D micro-resonator that increases the Q by up to 1000% compared to that in air. We have conducted precise experiments on piezoelectric, circular, membrane-type micro-resonators of 4 mm diameter fabricated using MEMS technology on silicon-on-insulator (SOI) wafers. The top side of the resonator was filled with different volumes of fluid and its Q was measured through resonance tracking by actuating the resonator with an appropriate voltage. We found the existence of an optimal volume of fluid that maximized the Q. We argue that this phenomenon is a result of a balance between the enhancement of kinetic energy of the resonator due to mass loading of the fluid and the energy dissipation through viscous and acoustic radiation losses in the fluid medium. This remarkable enhancement in Q substantially improves the sensitivity of the resonator, with important implications for diverse applications such as biosensing, chemical detection, and environmental monitoring. Our findings challenge the prevailing understanding of resonant sensing in fluids and open up new avenues for the development of highly sensitive and accurate sensors.
△ Less
Submitted 8 December, 2023;
originally announced December 2023.
-
PMUT-Powered Photoacoustic Detection: Revolutionizing Microfluidic Concentration Measurements
Authors:
Kaustav Roy,
Akshay Kumar,
Vijayendra Shastri,
Isha Munjal,
Kritank Kalyan,
Anuj Ashok,
Anthony Jeyaseelan,
Jaya Prakash,
Rudra Pratap
Abstract:
This report introduces a novel optofluidic platform based on piezo-MEMS technology, capable of identifying subtle variations in the fluid concentration. The system utilizes piezoelectric micromachined ultrasound transducers (PMUTs) as receivers to capture sound waves produced by nanosecond photoacoustic (PA) pulses emanating from a fluid target housed in PDMS microchannels. Additionally, a dedicat…
▽ More
This report introduces a novel optofluidic platform based on piezo-MEMS technology, capable of identifying subtle variations in the fluid concentration. The system utilizes piezoelectric micromachined ultrasound transducers (PMUTs) as receivers to capture sound waves produced by nanosecond photoacoustic (PA) pulses emanating from a fluid target housed in PDMS microchannels. Additionally, a dedicated low-noise single-channel amplifier has been developed to extract the minute analog voltage signals from the PMUTs, given the inherently weak ultrasound signals generated by fluid targets. The PMUTs' proficiency in detecting changes in fluid concentration under both static and time-varying conditions has been documented and verified, confirming the platform's efficacy in monitoring fluid concentrations.
△ Less
Submitted 5 December, 2023;
originally announced December 2023.
-
Stabilizing ultrathin Silver (Ag) films on different substrates
Authors:
Allamula Ashok,
Pradeep Kumar Rana,
Daljin Jacob,
Peela Lasya,
P Muhammed Razi,
Satyesh Kumar Yadav
Abstract:
This paper reports an effective method of stabilizing ultrathin Silver (Ag) films on substrates using a filler metal (Zn). Ag films with a thickness < 15 nm were deposited by DC magnetron sputtering above a Zn filler metal on glass, quartz, silicon and PET (polyethylene terephthalate) substrates. Zinc is expected to partially or fully fill the roughness associated with the substrates. The Zn fille…
▽ More
This paper reports an effective method of stabilizing ultrathin Silver (Ag) films on substrates using a filler metal (Zn). Ag films with a thickness < 15 nm were deposited by DC magnetron sputtering above a Zn filler metal on glass, quartz, silicon and PET (polyethylene terephthalate) substrates. Zinc is expected to partially or fully fill the roughness associated with the substrates. The Zn filler material and ultrathin Ag film form a 3-D augmented atomically chemically graded interface. 3-D interfaces have smoothly varying chemistry. The ability of Zn to partially or fully fill the substrate roughness improves the adhesion of Zn along with the Ag to the substrate. Also, Zn acts as a barrier layer against the diffusion of Ag into the substrate. This technique leads to ultrathin Ag films with low sheet resistance (~ 3 Ω/Sq.), low mean absolute surface roughness (~1 nm), good optical transparency (~ 65 %), better stability and compatibility with the environment. The results indicate significant potential for applying stable ultrathin Ag film/electrode as a practical and economically feasible design solution for optoelectronic (transparent and conductive electrodes for solar cells and LEDs) and plasmonic devices. This film shows good conductivity, transparency, stability, and flexibility.
△ Less
Submitted 27 June, 2023;
originally announced June 2023.
-
Instabilities of Decelerating Flow
Authors:
Ahire Swapnil Ashok,
Manu K. V
Abstract:
This paper numerically investigates the instability characteristics of decelerating flows. The flow dynamics and temporal evolution of coherent structures in a diverging section with mild spatial pressure gradient are analyzed using numerical experiments with Incompact3d code. The unsteady nature of flow and adverse pressure gradient is the reason for inflectional velocity profiles, results into b…
▽ More
This paper numerically investigates the instability characteristics of decelerating flows. The flow dynamics and temporal evolution of coherent structures in a diverging section with mild spatial pressure gradient are analyzed using numerical experiments with Incompact3d code. The unsteady nature of flow and adverse pressure gradient is the reason for inflectional velocity profiles, results into boundary layer separation and instability with reverse flow and later on it leads to vortex formation. Vortex formation time is found by vortex Reynold's number. Time of first vortex formation, non-dimensional vortex formation times with Reynold's number etc. are validated with an experimental results.
△ Less
Submitted 29 May, 2023;
originally announced May 2023.
-
Photoacoustic Image Quality Improvement from a Single Cell Low Frequency PMUT
Authors:
Kaustav Roy,
Arijit Paramanik,
Souradip Paul,
Akshay Kalyan,
Eshani Sarkar,
Anuj Ashok,
Rudra Pratap,
M Suheshkumar Singh
Abstract:
Photoacoustic image (PAI) quality improvement using a low frequency piezoelectric micromachined ultrasound transducer (PMUT) having the fundamental resonant frequency 1 MHz is being reported. Specifically, three different methods are implemented such as the frame averaging, mathematically improved algorithms, and a hardware position accurate arrangement in order to obtain unparallel PAI image qual…
▽ More
Photoacoustic image (PAI) quality improvement using a low frequency piezoelectric micromachined ultrasound transducer (PMUT) having the fundamental resonant frequency 1 MHz is being reported. Specifically, three different methods are implemented such as the frame averaging, mathematically improved algorithms, and a hardware position accurate arrangement in order to obtain unparallel PAI image quality. Validation study has been conducted in both agar phantom and ex-vivo tissue samples. Measurable image quantifiers in the form of full width at half maximum (FWHM), signal to noise ratio (SNR), and contrast ratio (CR) are used to evaluate the improvement in the image quality. It is found that the FWHM increases by 34%, SNR by 23% and CR by 25%, suggesting the efficacy of the methods to achieve better photoacoustic images employing PMUT-based detector. The study demonstrates that the suggested methods of improvement could play a key role in a promising cost-effective PMUT-PAI system in future.
△ Less
Submitted 30 November, 2022;
originally announced November 2022.
-
Quantum Multi-Parameter Adaptive Bayesian Estimation and Application to Super-Resolution Imaging
Authors:
Kwan Kit Lee,
Christos Gagatsos,
Saikat Guha,
Amit Ashok
Abstract:
In Bayesian estimation theory, the estimator ${\hat θ} = E[θ|l]$ attains the minimum mean squared error (MMSE) for estimating a scalar parameter of interest $θ$ from the observation of $l$ through a noisy channel $P_{l|θ}$, given a prior $P_θ$ on $θ$. In quantum sensing tasks, the user gets $ρ_θ$, the quantum state that encodes $θ$. They choose a measurement, a positive-operator valued measure (PO…
▽ More
In Bayesian estimation theory, the estimator ${\hat θ} = E[θ|l]$ attains the minimum mean squared error (MMSE) for estimating a scalar parameter of interest $θ$ from the observation of $l$ through a noisy channel $P_{l|θ}$, given a prior $P_θ$ on $θ$. In quantum sensing tasks, the user gets $ρ_θ$, the quantum state that encodes $θ$. They choose a measurement, a positive-operator valued measure (POVM) $Π_l$, which induces the channel $P_{l|θ} = {\rm Tr}(ρ_θΠ_l)$ to the measurement outcome $l$, on which the aforesaid classical MMSE estimator is employed. Personick found the optimum POVM $Π_l$ that minimizes the MMSE over all possible measurements, and that MMSE. This result from 1971 is less-widely known than the quantum Fisher information (QFI), which lower bounds the variance of an unbiased estimator over all measurements, when $P_θ$ is unavailable. For multi-parameter estimation, i.e., when $θ$ is a vector, in Fisher quantum estimation theory, the inverse of the QFI matrix provides an operator lower bound to the covariance of an unbiased estimator. However, there has been little work on quantifying quantum limits and measurement designs, for multi-parameter quantum estimation in the {\em Bayesian} setting. In this paper, we build upon Personick's result to construct a Bayesian adaptive measurement scheme for multi-parameter estimation when $N$ copies of $ρ_θ$ are available. We illustrate an application to localizing a cluster of point emitters in a highly sub-Rayleigh angular field-of-view, an important problem in fluorescence microscopy and astronomy. Our algorithm translates to a multi-spatial-mode transformation prior to a photon-detection array, with electro-optic feedback to adapt the mode sorter. We show that this receiver performs far superior to quantum-noise-limited focal-plane direct imaging.
△ Less
Submitted 9 June, 2022; v1 submitted 20 February, 2022;
originally announced February 2022.
-
An Experimental Study of the Acoustic Field of a Single-Cell Piezoelectric Micromachined Ultrasound Transducer (PMUT)
Authors:
Bibhas Nayak,
Harshvardhan Gupta,
Kaustav Roy,
Anuj Ashok,
Vijayendra Shastri,
Rudra Pratap
Abstract:
Piezoelectric micromachined ultrasound transducers (PMUTs) have gained popularity in the past decade as acoustic transmitters and receivers. As these devices usually operate at resonance, they can deliver large output sound pressures with very low power consumption. This paper explores the influence of the transmitter's packaging on the radiated acoustic field in air. We run simplified axisymmetri…
▽ More
Piezoelectric micromachined ultrasound transducers (PMUTs) have gained popularity in the past decade as acoustic transmitters and receivers. As these devices usually operate at resonance, they can deliver large output sound pressures with very low power consumption. This paper explores the influence of the transmitter's packaging on the radiated acoustic field in air. We run simplified axisymmetric numerical models to observe the change in the acoustic field and directivity with respect to the device's package dimensions. The simulations demonstrate a notable change in the directivity of transmitter based on the size of the baffle. Experimental measurements are carried out to validate the simulations, which prove useful in designing packages for transmitters to meet application specific requirements.
△ Less
Submitted 15 July, 2021;
originally announced August 2021.
-
A PMUT Integrated Microfluidic System for Fluid Density Sensing
Authors:
Kaustav Roy,
Kritank Kalyan,
Anuj Ashok,
Vijayendra Shastri,
Antony Jeyaseelan,
Avinandan Mandal,
Rudra Pratap
Abstract:
We demonstrate the design, fabrication and use of a dual electrode PMUT (Piezoelectric Micromachined Ultrasound Transducer) integrated with a microfluidic channel as a fluid density sensor in both static and dynamic density-change conditions. The dual electrode configuration makes the PMUT resonator a self-contained resonant peak-shift sensor and the microfluidic integration makes this system a ve…
▽ More
We demonstrate the design, fabrication and use of a dual electrode PMUT (Piezoelectric Micromachined Ultrasound Transducer) integrated with a microfluidic channel as a fluid density sensor in both static and dynamic density-change conditions. The dual electrode configuration makes the PMUT resonator a self-contained resonant peak-shift sensor and the microfluidic integration makes this system a versatile fluid density sensing platform that can be used with extremely low volumes of fluids in various industrial and healthcare applications. The density measurements carried out here under flowing fluid conditions demonstrate the potential of this system as a real-time fluid density monitoring system. We include results of density measurements in the range of 1020 - 1090 kg/m3 that corresponds to the human blood density variation generally due to the change in its hemoglobin content. The sensitivity of the sensor-26.3 Hz/(kg/m3)-is good enough to reliably detect even 1% change in the hemoglobin content of the human blood. Thus, this system could potentially be used also as a hemoglobin measurement sensor in healthcare applications.
△ Less
Submitted 23 April, 2021;
originally announced April 2021.
-
Invertibility of Multi-Energy X-ray Transform
Authors:
Yijun Ding,
Eric W. Clarkson,
Amit Ashok
Abstract:
Purpose: The goal is to provide a sufficient condition on the invertibility of a multi-energy (ME) X-ray transform. The energy-dependent X-ray attenuation profiles can be represented by a set of coefficients using the Alvarez-Macovski (AM) method. An ME X-ray transform is a mapping from $N$ AM coefficients to $N$ noise-free energy-weighted measurements, where $N\geq2$.
Methods: We apply a genera…
▽ More
Purpose: The goal is to provide a sufficient condition on the invertibility of a multi-energy (ME) X-ray transform. The energy-dependent X-ray attenuation profiles can be represented by a set of coefficients using the Alvarez-Macovski (AM) method. An ME X-ray transform is a mapping from $N$ AM coefficients to $N$ noise-free energy-weighted measurements, where $N\geq2$.
Methods: We apply a general invertibility theorem which tests whether the Jacobian of the mapping $J(\mathbf A)$ has zero values over the support of the mapping. The Jacobian of an arbitrary ME X-ray transform is an integration over all spectral measurements. A sufficient condition of $J(\mathbf A)\neq0$ for all $\mathbf A$ is that the integrand of $J(\mathbf A)$ is $\geq0$ (or $\leq0$) everywhere. Note that the trivial case of the integrand equals to zero everywhere is ignored. With symmetry, we simplified the integrand of the Jacobian into three factors that are determined by the total attenuation, the basis functions, and the energy-weighting functions, respectively. The factor related to total attenuation is always positive, hence the invertibility of the X-ray transform can be determined by testing the signs of the other two factors. Furthermore, we use the Cramer-Rao lower bound (CRLB) to characterize the noise-induced estimation uncertainty and provide a maximum-likelihood (ML) estimator.
Conclusions: We have provided a framework to study the invertibility of an arbitrary ME X-ray transform and proved the global invertibility for four types of systems.
△ Less
Submitted 12 October, 2021; v1 submitted 8 July, 2020;
originally announced July 2020.
-
X-ray measurement model incorporating energy-correlated material variability and its application in information-theoretic system analysis
Authors:
Yijun Ding,
Amit Ashok
Abstract:
Extending our prior work, we propose a multi-energy X-ray measurement model incorporating material variability with energy correlations to enable the analysis and exploration of the performance of X-ray imaging and sensing systems. Based on this measurement model, we provide analytical expressions for bounds on the probability of error, $P_e$, to quantify the performance limits of an X-ray measure…
▽ More
Extending our prior work, we propose a multi-energy X-ray measurement model incorporating material variability with energy correlations to enable the analysis and exploration of the performance of X-ray imaging and sensing systems. Based on this measurement model, we provide analytical expressions for bounds on the probability of error, $P_e$, to quantify the performance limits of an X-ray measurement system for binary classification task. We analyze the performance of a prototypical X-ray measurement system to demonstrate the utility of our proposed material variability measurement model.
△ Less
Submitted 21 February, 2020;
originally announced February 2020.
-
Approaching Quantum Limited Super-Resolution Imaging without Prior Knowledge of the Object Location
Authors:
Michael R Grace,
Zachary Dutton,
Amit Ashok,
Saikat Guha
Abstract:
A recently identified class of receivers which demultiplex an optical field into a set of orthogonal spatial modes prior to detection can surpass canonical diffraction limits on spatial resolution for simple incoherent imaging tasks. However, these mode-sorting receivers tend to exhibit high sensitivity to contextual nuisance parameters (e.g., the centroid of a clustered or extended object), raisi…
▽ More
A recently identified class of receivers which demultiplex an optical field into a set of orthogonal spatial modes prior to detection can surpass canonical diffraction limits on spatial resolution for simple incoherent imaging tasks. However, these mode-sorting receivers tend to exhibit high sensitivity to contextual nuisance parameters (e.g., the centroid of a clustered or extended object), raising questions on their viability in realistic imaging scenarios where little or no prior information about the scene is available. We propose a multi-stage passive imaging strategy which segments the total recording time between different physical measurements to build up the required prior information for near quantum-optimal imaging performance at sub-Rayleigh length scales. We show via Monte Carlo simulations that an adaptive two-stage scheme which dynamically allocates the total recording time between a traditional direct detection measurement and a binary mode-sorting receiver outperforms idealized direct detection alone for simple estimation tasks when no prior knowledge of the object centroid is available, achieving one to two orders of magnitude improvement in mean squared error. Our scheme can be generalized for more sophisticated imaging tasks with multiple parameters and minimal prior information.
△ Less
Submitted 6 August, 2019;
originally announced August 2019.
-
Attaining the quantum limit of super resolution in imaging an object's length via pre-detection spatial mode sorting
Authors:
Zachary Dutton,
Ronan Kerviche,
Amit Ashok,
Saikat Guha
Abstract:
Recent work considered the ultimate (quantum) limit of the precision of estimating the distance between two point objects. It was shown that the performance gap between the quantum limit and that of ideal continuum image-plane direct detection is the largest for highly sub-Rayleigh separation of the objects, and that a pre-detection mode sorting could attain the quantum limit. Here we extend this…
▽ More
Recent work considered the ultimate (quantum) limit of the precision of estimating the distance between two point objects. It was shown that the performance gap between the quantum limit and that of ideal continuum image-plane direct detection is the largest for highly sub-Rayleigh separation of the objects, and that a pre-detection mode sorting could attain the quantum limit. Here we extend this to a more general problem of estimating the length of an incoherently radiating extended (line) object. We find, as expected by the Rayleigh criterion, the Fisher information (FI) per integrated photon vanishes in the limit of small length for ideal image plane direct detection. Conversely, for a Hermite-Gaussian (HG) pre-detection mode sorter, this normalized FI does not decrease with decreasing object length, similar to the two point object case. However, unlike in the two-object problem, the FI per photon of both detection strategies gradually decreases as the object length greatly exceeds the Rayleigh limit, due to the relative inefficiency of information provided by photons emanating from near the center of the object about its length. We evaluate the quantum Fisher information per unit integrated photons and find that the HG mode sorter exactly achieves this limit at all values of the object length. Further, a simple binary mode sorter maintains the advantage of the full mode sorter at highly sub-Rayleigh length. In addition to this FI analysis, we quantify improvement in terms of the actual mean squared error of the length estimate. Finally, we consider the effect of imperfect mode sorting, and show that the performance improvement over direct detection is robust over a range of sub-Rayleigh lengths.
△ Less
Submitted 19 January, 2018;
originally announced January 2018.
-
Fundamental limit of resolving two point sources limited by an arbitrary point spread function
Authors:
Ronan Kerviche,
Saikat Guha,
Amit Ashok
Abstract:
Estimating the angular separation between two incoherently radiating monochromatic point sources is a canonical toy problem to quantify spatial resolution in imaging. In recent work, Tsang {\em et al.} showed, using a Fisher Information analysis, that Rayleigh's resolution limit is just an artifact of the conventional wisdom of intensity measurement in the image plane. They showed that the optimal…
▽ More
Estimating the angular separation between two incoherently radiating monochromatic point sources is a canonical toy problem to quantify spatial resolution in imaging. In recent work, Tsang {\em et al.} showed, using a Fisher Information analysis, that Rayleigh's resolution limit is just an artifact of the conventional wisdom of intensity measurement in the image plane. They showed that the optimal sensitivity of estimating the angle is only a function of the total photons collected during the camera's integration time but entirely independent of the angular separation itself no matter how small it is, and found the information-optimal mode basis, intensity detection in which achieves the aforesaid performance. We extend the above analysis, which was done for a Gaussian point spread function (PSF) to a hard-aperture pupil proving the information optimality of image-plane sinc-Bessel modes, and generalize the result further to an arbitrary PSF. We obtain new counterintuitive insights on energy vs. information content in spatial modes, and extend the Fisher Information analysis to exact calculations of minimum mean squared error, both for Gaussian and hard aperture pupils.
△ Less
Submitted 17 January, 2017;
originally announced January 2017.