-
The SHMS 11 GeV/c Spectrometer in Hall C at Jefferson Lab
Authors:
S. Ali,
A. Ahmidouch,
G. R. Ambrose,
A. Asaturyan,
C. Ayerbe Gayoso,
J. Benesch,
V. Berdnikov,
H. Bhatt,
D. Bhetuwal,
D. Biswas,
P. Brindza,
M. Bukhari,
M. Burton,
R. Carlini,
M. Carmignotto,
M. E. Christy,
C. Cotton,
J. Crafts,
D. Day,
S. Danagoulian,
A. Dittmann,
D. H. Dongwi,
B. Duran,
D. Dutta,
R. Ent
, et al. (50 additional authors not shown)
Abstract:
The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/c, the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnet…
▽ More
The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/c, the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5 to 40 degrees, thus allowing a wide range of low cross-section experiments to be conducted. These experiments complement and extend the previous Hall C research program to higher energies.
△ Less
Submitted 9 March, 2025;
originally announced March 2025.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and developing detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
Scintillating crystals for the Neutral Particle Spectrometer in Hall C at JLab
Authors:
T. Horn,
V. V. Berdnikov,
S. Ali,
A. Asaturyan,
M. Carmignotto,
J. Crafts,
A. Demarque,
R. Ent,
G. Hull,
H. -S. Ko,
M. Mostafavi,
C. Munoz-Camacho,
A. Mkrtchyan,
H. Mkrtchyan,
T. Nguyen Trung,
I. L. Pegg,
E. Rindel,
A. Somov,
V. Tadevosyan,
R. Trotta,
S. Zhamkochyan,
R. Wang,
S. A. Wood
Abstract:
This paper discusses the quality and performance of currently available PbWO$_4$ crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron-Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihi…
▽ More
This paper discusses the quality and performance of currently available PbWO$_4$ crystals of relevance to high-resolution electromagnetic calorimetry, e.g. detectors for the Neutral Particle Spectrometer at Jefferson Lab or those planned for the Electron-Ion Collider. Since the construction of the Compact Muon Solenoid (CMS) at the Large Hadron Collider (LHC) and early PANDA (The antiProton ANnihilations at DArmstadt) electromagnetic calorimeter (ECAL) the worldwide availability of high quality PbWO$_4$ production has changed dramatically. We report on our studies of crystal samples from SICCAS/China and CRYTUR/Czech Republic that were produced between 2014 and 2019.
△ Less
Submitted 24 November, 2019;
originally announced November 2019.
-
Design and Performance of the Spin Asymmetries of the Nucleon Experiment
Authors:
J. D. Maxwell,
W. R. Armstrong,
S. Choi,
M. K. Jones,
H. Kang,
A. Liyanage,
Z. -E. Meziani,
J. Mulholland,
L. Ndukum,
O. A. Rondon,
A. Ahmidouch,
I. Albayrak,
A. Asaturyan,
O. Ates,
H. Baghdasaryan,
W. Boeglin,
P. Bosted,
E. Brash,
J. Brock,
C. Butuceanu,
M. Bychkov,
C. Carlin,
P. Carter,
C. Chen,
J. -P. Chen
, et al. (80 additional authors not shown)
Abstract:
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employin…
▽ More
The Spin Asymmetries of the Nucleon Experiment (SANE) performed inclusive, double-polarized electron scattering measurements of the proton at the Continuous Electron Beam Accelerator Facility at Jefferson Lab. A novel detector array observed scattered electrons of four-momentum transfer $2.5 < Q^2< 6.5$ GeV$^2$ and Bjorken scaling $0.3<x<0.8$ from initial beam energies of 4.7 and 5.9 GeV. Employing a polarized proton target whose magnetic field direction could be rotated with respect to the incident electron beam, both parallel and near perpendicular spin asymmetries were measured, allowing model-independent access to transverse polarization observables $A_1$, $A_2$, $g_1$, $g_2$ and moment $d_2$ of the proton. This document summarizes the operation and performance of the polarized target, polarized electron beam, and novel detector systems used during the course of the experiment, and describes analysis techniques utilized to access the physics observables of interest.
△ Less
Submitted 21 December, 2017; v1 submitted 22 November, 2017;
originally announced November 2017.
-
A novel comparison of Møller and Compton electron-beam polarimeters
Authors:
J. A. Magee,
A. Narayan,
D. Jones,
R. Beminiwattha,
J. C. Cornejo,
M. M. Dalton,
W. Deconinck,
D. Dutta,
D. Gaskell,
J. W. Martin,
K. D. Paschke,
V. Tvaskis,
A. Asaturyan,
J. Benesch,
G. Cates,
B. S. Cavness,
L. A. Dillon-Townes,
G. Hays,
J. Hoskins,
E. Ihloff,
R. Jones,
P. M. King,
S. Kowalski,
L. Kurchaninov,
L. Lee
, et al. (16 additional authors not shown)
Abstract:
We have performed a novel comparison between electron-beam polarimeters based on Møller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents ($<$ 5 $μ$A) during the $Q_{\rm weak}$ experiment in Hall C at Jefferson Lab. These low current measurements were bracketed by the regular high current (180 $μ$A) operation of the Compton polarimete…
▽ More
We have performed a novel comparison between electron-beam polarimeters based on Møller and Compton scattering. A sequence of electron-beam polarization measurements were performed at low beam currents ($<$ 5 $μ$A) during the $Q_{\rm weak}$ experiment in Hall C at Jefferson Lab. These low current measurements were bracketed by the regular high current (180 $μ$A) operation of the Compton polarimeter. All measurements were found to be consistent within experimental uncertainties of 1% or less, demonstrating that electron polarization does not depend significantly on the beam current. This result lends confidence to the common practice of applying Møller measurements made at low beam currents to physics experiments performed at higher beam currents. The agreement between two polarimetry techniques based on independent physical processes sets an important benchmark for future precision asymmetry measurements that require sub-1% precision in polarimetry.
△ Less
Submitted 25 January, 2017; v1 submitted 19 October, 2016;
originally announced October 2016.
-
The Aerogel Cherenkov Detector for the SHMS magnetic spectrometer in Hall C at Jefferson Lab
Authors:
T. Horn,
H. Mkrtchyan,
S. Ali,
A. Asaturyan,
M. A. P. Carmignotto,
A. Dittmann,
D. Dutta,
R. Ent,
N. Hlavin,
Y. Illieva,
A. Mkrtchyan,
P. Nadel-Turonski,
I. L. Pegg,
A. Ramos,
J. Reinhold,
I. Sapkota,
V. Tadevosyan,
S. Zhamkochyan,
S. A. Wood
Abstract:
Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C…
▽ More
Hadronic reactions producing strange quarks such as exclusive or semi-inclusive kaon production, play an important role in studies of hadron structure and the dynamics that bind the most basic elements of nuclear physics. The small-angle capability of the new Super High Momentum Spectrometer (SHMS) in Hall C, coupled with its high momentum reach - up to the anticipated 11-GeV beam energy in Hall C - and coincidence capability with the well-understood High Momentum Spectrometer, will allow for probes of such hadron structure involving strangeness down to the smallest distance scales to date. To cleanly select the kaons, a threshold aerogel Cerenkov detector has been constructed for the SHMS. The detector consists of an aerogel tray followed by a diffusion box. Four trays for aerogel of nominal refractive indices of n=1.030, 1.020, 1.015 and 1.011 were constructed. The tray combination will allow for identification of kaons from 1 GeV/c up to 7.2 GeV/c, reaching 10^-2 proton and 10^-3 pion rejection, with kaon detection efficiency better than 95%. The diffusion box of the detector is equipped with 14 five-inch diameter photomultiplier tubes. Its interior walls are covered with Gore diffusive reflector, which is superior to the commonly used Millipore paper and improved the detector performance by 35%. The inner surface of the two aerogel trays with higher refractive index is covered with Millipore paper, however, those two trays with lower aerogel refractive index are again covered with Gore diffusive reflector for higher performance. The measured mean number of photoelectrons in saturation is ~12 for n=1.030, ~sim8 for n=1.020, ~10 for n=1.015, and ~5.5 for n=1.011. The design details, the results of component characterization, and initial performance tests and optimization of the detector are presented.
△ Less
Submitted 15 July, 2016;
originally announced July 2016.
-
Precision Electron-Beam Polarimetry using Compton Scattering at 1 GeV
Authors:
A. Narayan,
D. Jones,
J. C. Cornejo,
M. M. Dalton,
W. Deconinck,
D. Dutta,
D. Gaskell,
J. W. Martin,
K. D. Paschke,
V. Tvaskis,
A. Asaturyan,
J. Benesch,
G. Cates,
B. S. Cavness,
L. A. Dillon-Townes,
G. Hays,
E. Ihloff,
R. Jones,
S. Kowalski,
L. Kurchaninov,
L. Lee,
A. McCreary,
M. McDonald,
A. Micherdzinska,
A. Mkrtchyan
, et al. (11 additional authors not shown)
Abstract:
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond micr…
▽ More
We report on the highest precision yet achieved in the measurement of the polarization of a low energy, $\mathcal{O}$(1 GeV), electron beam, accomplished using a new polarimeter based on electron-photon scattering, in Hall~C at Jefferson Lab. A number of technical innovations were necessary, including a novel method for precise control of the laser polarization in a cavity and a novel diamond micro-strip detector which was able to capture most of the spectrum of scattered electrons. The data analysis technique exploited track finding, the high granularity of the detector and its large acceptance. The polarization of the $180~μ$A, $1.16$~GeV electron beam was measured with a statistical precision of $<$~1\% per hour and a systematic uncertainty of 0.59\%. This exceeds the level of precision required by the \qweak experiment, a measurement of the vector weak charge of the proton. Proposed future low-energy experiments require polarization uncertainty $<$~0.4\%, and this result represents an important demonstration of that possibility. This measurement is also the first use of diamond detectors for particle tracking in an experiment.
△ Less
Submitted 17 February, 2016; v1 submitted 22 September, 2015;
originally announced September 2015.
-
Search for polarization effects in the antiproton production process
Authors:
D. Grzonka,
K. Kilian,
J. Ritman,
T. Sefzick,
W. Oelert,
M. Diermaier,
E. Widmann,
J. Zmeskal,
B. Glowacz,
P. Moskal,
M. Zielinski,
M. Wolke,
P. Nadel-Turonski,
M. Carmignotto,
T. Horn,
H. Mkrtchyan,
A. Asaturyan,
A. Mkrtchyan,
V. Tadevosyan,
S. Zhamkochyan,
S. Malbrunot-Ettenauer,
W. Eyrich,
F. Hauenstein,
A. Zink
Abstract:
For the production of a polarized antiproton beam various methods have been suggested including the possibility that antiprotons may be produced polarized which will be checked experimentally. The polarization of antiprotons produced under typical conditions for antiproton beam preparation will be measured at the CERN/PS. If the production process creates some polarization a polarized antiproton b…
▽ More
For the production of a polarized antiproton beam various methods have been suggested including the possibility that antiprotons may be produced polarized which will be checked experimentally. The polarization of antiprotons produced under typical conditions for antiproton beam preparation will be measured at the CERN/PS. If the production process creates some polarization a polarized antiproton beam could be prepared by a rather simple modification of the antiproton beam facility. The detection setup and the expected experimental conditions are described.
△ Less
Submitted 23 January, 2015;
originally announced January 2015.
-
The Q_weak Experimental Apparatus
Authors:
Qweak Collaboration,
T. Allison,
M. Anderson,
D. Androic,
D. S. Armstrong,
A. Asaturyan,
T. D. Averett,
R. Averill,
J. Balewski,
J. Beaufait,
R. S. Beminiwattha,
J. Benesch,
F. Benmokhtar,
J. Bessuille,
J. Birchall,
E. Bonnell,
J. Bowman,
P. Brindza,
D. B. Brown,
R. D. Carlini,
G. D. Cates,
B. Cavness,
G. Clark,
J. C. Cornejo,
S. Covrig Dusa
, et al. (104 additional authors not shown)
Abstract:
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry…
▽ More
The Jefferson Lab Q_weak experiment determined the weak charge of the proton by measuring the parity-violating elastic scattering asymmetry of longitudinally polarized electrons from an unpolarized liquid hydrogen target at small momentum transfer. A custom apparatus was designed for this experiment to meet the technical challenges presented by the smallest and most precise ${\vec{e}}$p asymmetry ever measured. Technical milestones were achieved at Jefferson Lab in target power, beam current, beam helicity reversal rate, polarimetry, detected rates, and control of helicity-correlated beam properties. The experiment employed 180 microA of 89% longitudinally polarized electrons whose helicity was reversed 960 times per second. The electrons were accelerated to 1.16 GeV and directed to a beamline with extensive instrumentation to measure helicity-correlated beam properties that can induce false asymmetries. Moller and Compton polarimetry were used to measure the electron beam polarization to better than 1%. The electron beam was incident on a 34.4 cm liquid hydrogen target. After passing through a triple collimator system, scattered electrons between 5.8 degrees and 11.6 degrees were bent in the toroidal magnetic field of a resistive copper-coil magnet. The electrons inside this acceptance were focused onto eight fused silica Cerenkov detectors arrayed symmetrically around the beam axis. A total scattered electron rate of about 7 GHz was incident on the detector array. The detectors were read out in integrating mode by custom-built low-noise pre-amplifiers and 18-bit sampling ADC modules. The momentum transfer Q^2 = 0.025 GeV^2 was determined using dedicated low-current (~100 pA) measurements with a set of drift chambers before (and a set of drift chambers and trigger scintillation counters after) the toroidal magnet.
△ Less
Submitted 6 January, 2015; v1 submitted 24 September, 2014;
originally announced September 2014.
-
Bucking Coil Implementation on PMT for Active Cancelling of Magnetic Field
Authors:
T. Gogami,
A. Asaturyan,
J. Bono,
P. Baturin,
C. Chen,
A. Chiba,
N. Chiga,
Y. Fujii,
O. Hashimoto,
D. Kawama,
T. Maruta,
V. Maxwell,
A. Mkrtchyan,
S. Nagao,
S. N. Nakamura,
J. Reinhold,
A. Shichijo,
L. Tang,
N. Taniya,
S. A. Wood,
Z. Ye
Abstract:
Aerogel and water Cerenkov detectors were employed to tag kaons for a lambda hypernuclear spectroscopic experiment which used the (e,e'K+) reaction in experimental Hall C at Jefferson Lab (JLab E05-115). Fringe fields from the kaon spectrometer magnet yielded ~5 Gauss at the photomultiplier tubes (PMT) for these detectors which could not be easily shielded. As this field results in a lowered kaon…
▽ More
Aerogel and water Cerenkov detectors were employed to tag kaons for a lambda hypernuclear spectroscopic experiment which used the (e,e'K+) reaction in experimental Hall C at Jefferson Lab (JLab E05-115). Fringe fields from the kaon spectrometer magnet yielded ~5 Gauss at the photomultiplier tubes (PMT) for these detectors which could not be easily shielded. As this field results in a lowered kaon detection efficiency, we implemented a bucking coil on each photomultiplier tubes to actively cancel this magnetic field, thus maximizing kaon detection efficiency.
△ Less
Submitted 2 July, 2013;
originally announced July 2013.
-
The lead-glass electromagnetic calorimeters for the magnetic spectrometers in Hall C at Jefferson Lab
Authors:
H. Mkrtchyan,
R. Carlini,
V. Tadevosyan,
J. Arrington,
A. Asaturyan,
M. E. Christy,
D. Dutta,
R. Ent,
H. C. Fenker,
D. Gaskell,
T. Horn,
M. K. Jones,
C. E. Keppel,
D. J. Mack,
S. P. Malace,
A. Mkrtchyan,
M. I. Niculescu,
J. Seely,
V. Tvaskis,
S. A. Wood,
S. Zhamkochyan
Abstract:
The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $σ/E \sim 6%/\sqrt E $, and pion/electron ($π/e$)…
▽ More
The electromagnetic calorimeters of the various magnetic spectrometers in Hall C at Jefferson Lab are presented. For the existing HMS and SOS spectrometers design considerations, relevant construction information, and comparisons of simulated and experimental results are included. The energy resolution of the HMS and SOS calorimeters is better than $σ/E \sim 6%/\sqrt E $, and pion/electron ($π/e$) separation of about 100:1 has been achieved in energy range 1 -- 5 GeV. Good agreement has been observed between the experimental and simulated energy resolutions, but simulations systematically exceed experimentally determined $π^-$ suppression factors by close to a factor of two. For the SHMS spectrometer presently under construction details on the design and accompanying GEANT4 simulation efforts are given. The anticipated performance of the new calorimeter is predicted over the full momentum range of the SHMS. Good electron/hadron separation is anticipated by combining the energy deposited in an initial (preshower) calorimeter layer with the total energy deposited in the calorimeter.
△ Less
Submitted 28 April, 2012;
originally announced April 2012.
-
The Qweak Experiment: A Search for New Physics at the TeV Scale via a Measurement of the Proton's Weak Charge
Authors:
R. D. Carlini,
J. M. Finn,
S. Kowalski,
S. A. Page,
D. S. Armstrong,
A. Asaturyan,
T. Averett,
J. Benesch,
J. Birchall,
P. Bosted,
A. Bruell,
C. L. Capuano,
G. Cates,
C. Carrigee,
S. Chattopadhyay,
S. Covrig,
C. A. Davis,
K. Dow,
J. Dunne,
D. Dutta,
R. Ent,
J. Erler,
W. Falk,
H. Fenker,
T. A. Forest
, et al. (61 additional authors not shown)
Abstract:
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep…
▽ More
We propose a new precision measurement of parity-violating electron scattering on the proton at very low Q^2 and forward angles to challenge predictions of the Standard Model and search for new physics. A unique opportunity exists to carry out the first precision measurement of the proton's weak charge, $Q_W =1 - 4\sin^2θ_W$. A 2200 hour measurement of the parity violating asymmetry in elastic ep scattering at Q^2=0.03 (GeV/c)^2 employing 180 $μ$A of 85% polarized beam on a 35 cm liquid Hydrogen target will determine the proton's weak charge with approximately 4% combined statistical and systematic errors. The Standard Model makes a firm prediction of $Q_W$, based on the running of the weak mixing angle from the Z0 pole down to low energies, corresponding to a 10 sigma effect in this experiment.
△ Less
Submitted 7 February, 2012; v1 submitted 6 February, 2012;
originally announced February 2012.