-
Measurement of SiPM Dark Currents and Annealing Recovery for Fluences Expected in ePIC Calorimeters at the Electron-Ion Collider
Authors:
Jiajun Huang,
Sean Preins,
Ryan Tsiao,
Miguel Rodriguez,
Barak Schmookler,
Miguel Arratia
Abstract:
Silicon photomultipliers (SiPMs) will be used to read out all calorimeters in the ePIC experiment at the Electron-Ion Collider (EIC). A thorough characterization of the radiation damage expected for SiPMs under anticipated EIC fluences is essential for accurate simulations, detector design, and effective operational strategies. In this study, we evaluate radiation damage for the specific SiPM mode…
▽ More
Silicon photomultipliers (SiPMs) will be used to read out all calorimeters in the ePIC experiment at the Electron-Ion Collider (EIC). A thorough characterization of the radiation damage expected for SiPMs under anticipated EIC fluences is essential for accurate simulations, detector design, and effective operational strategies. In this study, we evaluate radiation damage for the specific SiPM models chosen for ePIC across the complete fluence range anticipated at the EIC, $10^8$ to $10^{12}$ 1-MeV $n_{\mathrm{eq}}$/cm$^2$ per year, depending on the calorimeter location. The SiPMs were irradiated using a 64 MeV proton beam provided by the University of California, Davis 76" Cyclotron. We measured the SiPM dark-current as a function of fluence and bias voltage and investigated the effectiveness of high-temperature annealing to recover radiation damage. These results provide a comprehensive reference for the design, simulation, and operational planning of all ePIC calorimeter systems.
△ Less
Submitted 18 March, 2025;
originally announced March 2025.
-
Tools for Unbinned Unfolding
Authors:
Ryan Milton,
Vinicius Mikuni,
Trevin Lee,
Miguel Arratia,
Tanvi Wamorkar,
Benjamin Nachman
Abstract:
Machine learning has enabled differential cross section measurements that are not discretized. Going beyond the traditional histogram-based paradigm, these unbinned unfolding methods are rapidly being integrated into experimental workflows. In order to enable widespread adaptation and standardization, we develop methods, benchmarks, and software for unbinned unfolding. For methodology, we demonstr…
▽ More
Machine learning has enabled differential cross section measurements that are not discretized. Going beyond the traditional histogram-based paradigm, these unbinned unfolding methods are rapidly being integrated into experimental workflows. In order to enable widespread adaptation and standardization, we develop methods, benchmarks, and software for unbinned unfolding. For methodology, we demonstrate the utility of boosted decision trees for unfolding with a relatively small number of high-level features. This complements state-of-the-art deep learning models capable of unfolding the full phase space. To benchmark unbinned unfolding methods, we develop an extension of existing dataset to include acceptance effects, a necessary challenge for real measurements. Additionally, we directly compare binned and unbinned methods using discretized inputs for the latter in order to control for the binning itself. Lastly, we have assembled two software packages for the OmniFold unbinned unfolding method that should serve as the starting point for any future analyses using this technique. One package is based on the widely-used RooUnfold framework and the other is a standalone package available through the Python Package Index (PyPI).
△ Less
Submitted 12 March, 2025;
originally announced March 2025.
-
First-Ever Deployment of a SiPM-on-Tile Calorimeter in a Collider: A Parasitic Test with 200 GeV $pp$ Collisions at RHIC
Authors:
Weibin Zhang,
Sean Preins,
Jiajun Huang,
Sebouh J. Paul,
Ryan Milton,
Miguel Rodriguez,
Peter Carney,
Ryan Tsiao,
Yousef Abdelkadous,
Miguel Arratia
Abstract:
We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV $pp$ run in 2024. The prototype, measuring $20 \times 20 \, \text{cm}^{2}$ and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapid…
▽ More
We describe the testing of a prototype SiPM-on-tile iron-scintillator calorimeter at the Relativistic Heavy Ion Collider (RHIC) during its 200 GeV $pp$ run in 2024. The prototype, measuring $20 \times 20 \, \text{cm}^{2}$ and 24 radiation lengths in depth, was positioned in the STAR experimental hall, approximately 8 m from the interaction point and 65 cm from the beam line, covering a pseudorapidity range of about $3.1<η<3.4$. By using the dark current of a reference SiPM as a radiation monitor, we estimate that the prototype was exposed to a fluence of about $10^{10}$ 1-MeV $n_{\mathrm{eq}}$/cm$^2$. Channel-by-channel calibration was performed in a data-driven way with the signature from minimum-ionizing particles during beam-on conditions. A Geant4 detector simulation, with inputs from the Pythia8 event generator, describes measurements of energy spectra and hit multiplicities reasonably well. These results mark the first deployment, commissioning, calibration, and long-term operation of a SiPM-on-tile calorimeter in a collider environment. This experimental campaign will guide detector designs and operational strategies for the ePIC detector at the future EIC, as well as other applications.
△ Less
Submitted 15 January, 2025;
originally announced January 2025.
-
Design of a SiPM-on-Tile ZDC for the future EIC and its Performance with Graph Neural Networks
Authors:
Ryan Milton,
Sebouh J. Paul,
Barak Schmookler,
Miguel Arratia,
Piyush Karande,
Aaron Angerami,
Fernando Torales Acosta,
Benjamin Nachman
Abstract:
We present a design for a high-granularity zero-degree calorimeter (ZDC) for the upcoming Electron-Ion Collider (EIC). The design uses SiPM-on-tile technology and features a novel staggered-layer arrangement that improves spatial resolution. To fully leverage the design's high granularity and non-trivial geometry, we employ graph neural networks (GNNs) for energy and angle regression as well as si…
▽ More
We present a design for a high-granularity zero-degree calorimeter (ZDC) for the upcoming Electron-Ion Collider (EIC). The design uses SiPM-on-tile technology and features a novel staggered-layer arrangement that improves spatial resolution. To fully leverage the design's high granularity and non-trivial geometry, we employ graph neural networks (GNNs) for energy and angle regression as well as signal classification. The GNN-boosted performance metrics meet, and in some cases, significantly surpass the requirements set in the EIC Yellow Report, laying the groundwork for enhanced measurements that will facilitate a wide physics program. Our studies show that GNNs can significantly enhance the performance of high-granularity CALICE-style calorimeters by automating and optimizing the software compensation algorithms required for these systems. This improvement holds true even in the case of complicated geometries that pose challenges for image-based AI/ML methods.
△ Less
Submitted 11 May, 2024;
originally announced June 2024.
-
The Optimal use of Segmentation for Sampling Calorimeters
Authors:
Fernando Torales Acosta,
Bishnu Karki,
Piyush Karande,
Aaron Angerami,
Miguel Arratia,
Kenneth Barish,
Ryan Milton,
Sebastián Morán,
Benjamin Nachman,
Anshuman Sinha
Abstract:
One of the key design choices of any sampling calorimeter is how fine to make the longitudinal and transverse segmentation. To inform this choice, we study the impact of calorimeter segmentation on energy reconstruction. To ensure that the trends are due entirely to hardware and not to a sub-optimal use of segmentation, we deploy deep neural networks to perform the reconstruction. These networks m…
▽ More
One of the key design choices of any sampling calorimeter is how fine to make the longitudinal and transverse segmentation. To inform this choice, we study the impact of calorimeter segmentation on energy reconstruction. To ensure that the trends are due entirely to hardware and not to a sub-optimal use of segmentation, we deploy deep neural networks to perform the reconstruction. These networks make use of all available information by representing the calorimeter as a point cloud. To demonstrate our approach, we simulate a detector similar to the forward calorimeter system intended for use in the ePIC detector, which will operate at the upcoming Electron Ion Collider. We find that for the energy estimation of isolated charged pion showers, relatively fine longitudinal segmentation is key to achieving an energy resolution that is better than 10% across the full phase space. These results provide a valuable benchmark for ongoing EIC detector optimizations and may also inform future studies involving high-granularity calorimeters in other experiments at various facilities.
△ Less
Submitted 2 October, 2023;
originally announced October 2023.
-
Beam Test of the First Prototype of SiPM-on-Tile Calorimeter Insert for the Electron-Ion Collider Using 4 GeV Positrons at Jefferson Laboratory
Authors:
Miguel Arratia,
Bruce Bagby,
Peter Carney,
Jiajun Huang,
Ryan Milton,
Sebouh J. Paul,
Sean Preins,
Miguel Rodriguez,
Weibin Zhang
Abstract:
We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that uses plastic scintillator tiles read out by SiPMs. Among its innovative features are an ASIC-away-of-SiPM strategy for reducing cooling requirements and minimizing space use, along with employing 3D-printed frames to reduce optical crosstalk and dead areas. To evaluate these features, we built a 40-…
▽ More
We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that uses plastic scintillator tiles read out by SiPMs. Among its innovative features are an ASIC-away-of-SiPM strategy for reducing cooling requirements and minimizing space use, along with employing 3D-printed frames to reduce optical crosstalk and dead areas. To evaluate these features, we built a 40-channel prototype and tested it using a 4 GeV positron beam at Jefferson Laboratory. The measured energy spectra and 3D shower shapes are well described by simulations, confirming the effectiveness of the design, construction techniques, and calibration strategy. This constitutes the first use of SiPM-on-tile technology in EIC detector designs.
△ Less
Submitted 2 September, 2023;
originally announced September 2023.
-
Leveraging Staggered Tessellation for Enhanced Spatial Resolution in High-Granularity Calorimeters
Authors:
Sebouh J. Paul,
Miguel Arratia
Abstract:
We advance the concept of high-granularity calorimeters with staggered tessellations, underscoring the effectiveness of a design incorporating multifold staggering cycles based on hexagonal cells to enhance position resolution. Moreover, we introduce HEXPLIT, a sub-cell re-weighting algorithm tailored to harness staggered designs, resulting in additional performance improvements. By combining our…
▽ More
We advance the concept of high-granularity calorimeters with staggered tessellations, underscoring the effectiveness of a design incorporating multifold staggering cycles based on hexagonal cells to enhance position resolution. Moreover, we introduce HEXPLIT, a sub-cell re-weighting algorithm tailored to harness staggered designs, resulting in additional performance improvements. By combining our proposed staggered design with HEXPLIT, we achieve an approximately twofold enhancement in position resolution for neutrons across a wide energy range, as compared to unstaggered designs. These findings hold the potential to elevate particle-flow performance across various forthcoming facilities.
△ Less
Submitted 29 August, 2023; v1 submitted 14 August, 2023;
originally announced August 2023.
-
A Few-Degree Calorimeter for the future Electron-Ion Collider
Authors:
Miguel Arratia,
Ryan Milton,
Sebouh J. Paul,
Barak Schmookler,
Weibin Zhang
Abstract:
Measuring the region $0.1 < Q^{2} < 1.0$ GeV$^{2}$ is essential to support searches for gluon saturation at the future Electron-Ion Collider. Recent studies have revealed that covering this region at the highest beam energies is not feasible with current detector designs, resulting in the so-called $Q^{2}$ gap. In this work, we present a design for the Few-Degree Calorimeter (FDC), which addresses…
▽ More
Measuring the region $0.1 < Q^{2} < 1.0$ GeV$^{2}$ is essential to support searches for gluon saturation at the future Electron-Ion Collider. Recent studies have revealed that covering this region at the highest beam energies is not feasible with current detector designs, resulting in the so-called $Q^{2}$ gap. In this work, we present a design for the Few-Degree Calorimeter (FDC), which addresses this issue. The FDC uses SiPM-on-tile technology with tungsten absorber and covers the range of $-4.6 < η< -3.6$. It offers fine transverse and longitudinal granularity, along with excellent time resolution, enabling standalone electron tagging. Our design represents the first concrete solution to bridge the $Q^{2}$ gap at the EIC.
△ Less
Submitted 24 July, 2023;
originally announced July 2023.
-
Comparison of Point Cloud and Image-based Models for Calorimeter Fast Simulation
Authors:
Fernando Torales Acosta,
Vinicius Mikuni,
Benjamin Nachman,
Miguel Arratia,
Bishnu Karki,
Ryan Milton,
Piyush Karande,
Aaron Angerami
Abstract:
Score based generative models are a new class of generative models that have been shown to accurately generate high dimensional calorimeter datasets. Recent advances in generative models have used images with 3D voxels to represent and model complex calorimeter showers. Point clouds, however, are likely a more natural representation of calorimeter showers, particularly in calorimeters with high gr…
▽ More
Score based generative models are a new class of generative models that have been shown to accurately generate high dimensional calorimeter datasets. Recent advances in generative models have used images with 3D voxels to represent and model complex calorimeter showers. Point clouds, however, are likely a more natural representation of calorimeter showers, particularly in calorimeters with high granularity. Point clouds preserve all of the information of the original simulation, more naturally deal with sparse datasets, and can be implemented with more compact models and data files. In this work, two state-of-the-art score based models are trained on the same set of calorimeter simulation and directly compared.
△ Less
Submitted 31 July, 2023; v1 submitted 10 July, 2023;
originally announced July 2023.
-
Studies of time resolution, light yield, and crosstalk using SiPM-on-tile calorimetry for the future Electron-Ion Collider
Authors:
Miguel Arratia,
Luis Garabito Ruiz,
Jiajun Huang,
Sebouh J. Paul,
Sean Preins,
Miguel Rodriguez
Abstract:
We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that is based on plastic scintillator tiles readout with silicon photomultipliers. In this work, we concretize its design by characterizing its building blocks with measurements of light yield, optical crosstalk, and timing resolutions using cosmic-rays, an LED, and a beta source. We also compared two ap…
▽ More
We recently proposed a high-granularity calorimeter insert for the Electron-Ion Collider (EIC) that is based on plastic scintillator tiles readout with silicon photomultipliers. In this work, we concretize its design by characterizing its building blocks with measurements of light yield, optical crosstalk, and timing resolutions using cosmic-rays, an LED, and a beta source. We also compared two approaches for the optical isolation of cells: ``megatiles'' with grooved boundaries between cells, and a 3D-printed plastic frame hosting individual cells. We found that the latter suppresses optical crosstalk to negligible levels while providing an easier assembly method. Overall, these performance studies can help inform calorimeter design and realistic simulations of 5D showers (time, energy, position) for the EIC and other experiments.
△ Less
Submitted 27 May, 2023; v1 submitted 7 February, 2023;
originally announced February 2023.
-
ATHENA Detector Proposal -- A Totally Hermetic Electron Nucleus Apparatus proposed for IP6 at the Electron-Ion Collider
Authors:
ATHENA Collaboration,
J. Adam,
L. Adamczyk,
N. Agrawal,
C. Aidala,
W. Akers,
M. Alekseev,
M. M. Allen,
F. Ameli,
A. Angerami,
P. Antonioli,
N. J. Apadula,
A. Aprahamian,
W. Armstrong,
M. Arratia,
J. R. Arrington,
A. Asaturyan,
E. C. Aschenauer,
K. Augsten,
S. Aune,
K. Bailey,
C. Baldanza,
M. Bansal,
F. Barbosa,
L. Barion
, et al. (415 additional authors not shown)
Abstract:
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its e…
▽ More
ATHENA has been designed as a general purpose detector capable of delivering the full scientific scope of the Electron-Ion Collider. Careful technology choices provide fine tracking and momentum resolution, high performance electromagnetic and hadronic calorimetry, hadron identification over a wide kinematic range, and near-complete hermeticity. This article describes the detector design and its expected performance in the most relevant physics channels. It includes an evaluation of detector technology choices, the technical challenges to realizing the detector and the R&D required to meet those challenges.
△ Less
Submitted 13 October, 2022;
originally announced October 2022.
-
A high-granularity calorimeter insert based on SiPM-on-tile technology at the future Electron-Ion Collider
Authors:
Miguel Arratia,
Kenneth Barish,
Liam Blanchard,
Huan Z. Huang,
Zhongling Ji,
Bishnu Karki,
Owen Long,
Ryan Milton,
Ananya Paul,
Sebouh J. Paul,
Sean Preins,
Barak Schmookler,
Oleg Tsai,
Zhiwan Xu
Abstract:
We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage close to the beampipe, while solving challenges arising from the beam-crossing angle and mechanical integration. It yields a compensated response that is linear…
▽ More
We present a design for a high-granularity calorimeter insert for future experiments at the Electron-Ion Collider (EIC). The sampling-calorimeter design uses scintillator tiles read out with silicon photomultipliers. It maximizes coverage close to the beampipe, while solving challenges arising from the beam-crossing angle and mechanical integration. It yields a compensated response that is linear over the energy range of interest for the EIC. Its energy resolution meets the requirements set in the EIC Yellow Report even with a basic reconstruction algorithm. Moreover, this detector will provide 5D shower data (position, energy, and time), which can be exploited with machine-learning techniques. This detector concept has the potential to unleash the power of imaging calorimetry at the EIC to enable measurements at extreme kinematics in electron-proton and electron-nucleus collisions.
△ Less
Submitted 12 December, 2022; v1 submitted 10 August, 2022;
originally announced August 2022.
-
Alignment of the CLAS12 central hybrid tracker with a Kalman Filter
Authors:
S. J. Paul,
A. Peck,
M. Arratia,
Y. Gotra,
V. Ziegler,
R. De Vita,
F. Bossu,
M. Defurne,
H. Atac,
C. Ayerbe Gayoso,
L. Baashen,
N. A. Baltzell,
L. Barion,
M. Bashkanov,
M. Battaglieri,
I. Bedlinskiy,
B. Benkel,
F. Benmokhtar,
A. Bianconi,
L. Biondo,
A. S. Biselli,
M. Bondi,
S. Boiarinov,
K. Th. Brinkmann,
W. J. Briscoe
, et al. (109 additional authors not shown)
Abstract:
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors wit…
▽ More
Several factors can contribute to the difficulty of aligning the sensors of tracking detectors, including a large number of modules, multiple types of detector technologies, and non-linear strip patterns on the sensors. All three of these factors apply to the CLAS12 CVT, which is a hybrid detector consisting of planar silicon sensors with non-parallel strips, and cylindrical micromegas sensors with longitudinal and arc-shaped strips located within a 5~T superconducting solenoid. To align this detector, we used the Kalman Alignment Algorithm, which accounts for correlations between the alignment parameters without requiring the time-consuming inversion of large matrices. This is the first time that this algorithm has been adapted for use with hybrid technologies, non-parallel strips, and curved sensors. We present the results for the first alignment of the CLAS12 CVT using straight tracks from cosmic rays and from a target with the magnetic field turned off. After running this procedure, we achieved alignment at the level of 10~$μ$m, and the widths of the residual spectra were greatly reduced. These results attest to the flexibility of this algorithm and its applicability to future use in the CLAS12 CVT and other hybrid or curved trackers, such as those proposed for the future Electron-Ion Collider.
△ Less
Submitted 9 August, 2022;
originally announced August 2022.
-
Presenting Unbinned Differential Cross Section Results
Authors:
Miguel Arratia,
Anja Butter,
Mario Campanelli,
Vincent Croft,
Aishik Ghosh,
Dag Gillberg,
Kristin Lohwasser,
Bogdan Malaescu,
Vinicius Mikuni,
Benjamin Nachman,
Juan Rojo,
Jesse Thaler,
Ramon Winterhalder
Abstract:
Machine learning tools have empowered a qualitatively new way to perform differential cross section measurements whereby the data are unbinned, possibly in many dimensions. Unbinned measurements can enable, improve, or at least simplify comparisons between experiments and with theoretical predictions. Furthermore, many-dimensional measurements can be used to define observables after the measuremen…
▽ More
Machine learning tools have empowered a qualitatively new way to perform differential cross section measurements whereby the data are unbinned, possibly in many dimensions. Unbinned measurements can enable, improve, or at least simplify comparisons between experiments and with theoretical predictions. Furthermore, many-dimensional measurements can be used to define observables after the measurement instead of before. There is currently no community standard for publishing unbinned data. While there are also essentially no measurements of this type public, unbinned measurements are expected in the near future given recent methodological advances. The purpose of this paper is to propose a scheme for presenting and using unbinned results, which can hopefully form the basis for a community standard to allow for integration into analysis workflows. This is foreseen to be the start of an evolving community dialogue, in order to accommodate future developments in this field that is rapidly evolving.
△ Less
Submitted 17 November, 2021; v1 submitted 27 September, 2021;
originally announced September 2021.
-
A Delphes card for the EIC yellow-report detector
Authors:
Miguel Arratia,
Stephen Sekula
Abstract:
The Electron-Ion Collider (EIC) Yellow Report specified parameters for the general-purpose detector that can deliver the scientific goals delineated by the EIC White Paper and NAS report. These parameters dictate the tracking momentum resolution, secondary-vertex resolutions, calorimeter energy resolutions, as well as $π/K/p$ ID. We have incorporated these parameters into a configuration card for…
▽ More
The Electron-Ion Collider (EIC) Yellow Report specified parameters for the general-purpose detector that can deliver the scientific goals delineated by the EIC White Paper and NAS report. These parameters dictate the tracking momentum resolution, secondary-vertex resolutions, calorimeter energy resolutions, as well as $π/K/p$ ID. We have incorporated these parameters into a configuration card for Delphes, which is a widely used "C++ framework, for performing a fast multipurpose detector response simulation". We include both the 1.5 T and 3.0 T scenarios. We also show the expected performance for high-level quantities such as jets, missing transverse energy, charm tagging, and others. These parametrizations can be easily updated with more refined Geant4 studies, which provides an efficient way to perform simulations to benchmark a variety of observables using state-of-the art event generators such as Pythia8.
△ Less
Submitted 11 March, 2021;
originally announced March 2021.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and developing detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.