The Electronics, Trigger and Data Acquisition System for the Liquid Argon Time Projection Chamber of the DarkSide-50 Search for Dark Matter
Authors:
DarkSide Collaboration,
P. Agnes,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
D. M. Asner,
M. Ave,
H. O. Back,
B. Baldin,
K. Biery,
V. Bocci,
G. Bonfini,
W. Bonivento,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela
, et al. (155 additional authors not shown)
Abstract:
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which proce…
▽ More
The DarkSide-50 experiment at the Laboratori Nazionali del Gran Sasso is a search for dark matter using a dual phase time projection chamber with 50 kg of low radioactivity argon as target. Light signals from interactions in the argon are detected by a system of 38 photo-multiplier tubes (PMTs), 19 above and 19 below the TPC volume inside the argon cryostat. We describe the electronics which processes the signals from the photo-multipliers, the trigger system which identifies events of interest, and the data-acquisition system which records the data for further analysis. The electronics include resistive voltage dividers on the PMTs, custom pre-amplifiers mounted directly on the PMT voltage dividers in the liquid argon, and custom amplifier/discriminators (at room temperature). After amplification, the PMT signals are digitized in CAEN waveform digitizers, and CAEN logic modules are used to construct the trigger, the data acquisition system for the TPC is based on the Fermilab "artdaq" software. The system has been in operation since early 2014.
△ Less
Submitted 20 November, 2017; v1 submitted 31 July, 2017;
originally announced July 2017.
-
The Electronics and Data Acquisition System for the DarkSide-50 Veto Detectors
Authors:
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
M. Carlini,
S. Catalanotti
, et al. (133 additional authors not shown)
Abstract:
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic muon veto detec…
▽ More
DarkSide-50 is a detector for dark matter candidates in the form of weakly interacting massive particles (WIMPs). It utilizes a liquid argon time projection chamber (LAr TPC) for the inner main detector. The TPC is surrounded by a liquid scintillator veto (LSV) and a water Cherenkov veto detector (WCV). The LSV and WCV, both instrumented with PMTs, act as the neutron and cosmogenic muon veto detectors for DarkSide-50. This paper describes the electronics and data acquisition system used for these two detectors.
△ Less
Submitted 10 June, 2016;
originally announced June 2016.
-
The veto system of the DarkSide-50 experiment
Authors:
The DarkSide Collaboration,
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
L. Cadonati,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello
, et al. (136 additional authors not shown)
Abstract:
Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector…
▽ More
Nuclear recoil events produced by neutron scatters form one of the most important classes of background in WIMP direct detection experiments, as they may produce nuclear recoils that look exactly like WIMP interactions. In DarkSide-50, we both actively suppress and measure the rate of neutron-induced background events using our neutron veto, composed of a boron-loaded liquid scintillator detector within a water Cherenkov detector. This paper is devoted to the description of the neutron veto system of DarkSide-50, including the detector structure, the fundamentals of event reconstruction and data analysis, and basic performance parameters.
△ Less
Submitted 24 December, 2015;
originally announced December 2015.
-
Results from the first use of low radioactivity argon in a dark matter search
Authors:
The DarkSide Collaboration,
P. Agnes,
L. Agostino,
I. F. M. Albuquerque,
T. Alexander,
A. K. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
B. Bottino,
A. Brigatti,
J. Brodsky,
F. Budano,
S. Bussino,
M. Cadeddu,
L. Cadonati,
M. Cadoni,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello
, et al. (136 additional authors not shown)
Abstract:
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the La…
▽ More
Liquid argon is a bright scintillator with potent particle identification properties, making it an attractive target for direct-detection dark matter searches. The DarkSide-50 dark matter search here reports the first WIMP search results obtained using a target of low-radioactivity argon. DarkSide-50 is a dark matter detector, using two-phase liquid argon time projection chamber, located at the Laboratori Nazionali del Gran Sasso. The underground argon is shown to contain Ar-39 at a level reduced by a factor (1.4 +- 0.2) x 10^3 relative to atmospheric argon. We report a background-free null result from (2616 +- 43) kg d of data, accumulated over 70.9 live-days. When combined with our previous search using an atmospheric argon, the 90 % C.L. upper limit on the WIMP-nucleon spin-independent cross section based on zero events found in the WIMP search regions, is 2.0 x 10^-44 cm^2 (8.6 x 10^-44 cm^2, 8.0 x 10^-43 cm^2) for a WIMP mass of 100 GeV/c^2 (1 TeV/c^2 , 10 TeV/c^2).
△ Less
Submitted 13 April, 2016; v1 submitted 2 October, 2015;
originally announced October 2015.
-
Search for Event Rate Modulation in XENON100 Electronic Recoil Data
Authors:
The XENON Collaboration,
E. Aprile,
J. Aalbers,
F. Agostini,
M. Alfonsi,
M. Anthony,
L. Arazi,
K. Arisaka,
F. Arneodo,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
P. A. Breur,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. M. R. Cardoso,
M. Cervantes,
D. Coderre,
A. P. Colijn,
H. Contreras
, et al. (77 additional authors not shown)
Abstract:
We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to ide…
▽ More
We have searched for periodic variations of the electronic recoil event rate in the (2-6) keV energy range recorded between February 2011 and March 2012 with the XENON100 detector, adding up to 224.6 live days in total. Following a detailed study to establish the stability of the detector and its background contributions during this run, we performed an un-binned profile likelihood analysis to identify any periodicity up to 500 days. We find a global significance of less than 1 sigma for all periods suggesting no statistically significant modulation in the data. While the local significance for an annual modulation is 2.8 sigma, the analysis of a multiple-scatter control sample and the phase of the modulation disfavor a dark matter interpretation. The DAMA/LIBRA annual modulation interpreted as a dark matter signature with axial-vector coupling of WIMPs to electrons is excluded at 4.8 sigma.
△ Less
Submitted 28 July, 2015;
originally announced July 2015.
-
Lowering the radioactivity of the photomultiplier tubes for the XENON1T dark matter experiment
Authors:
E. Aprile,
F. Agostini,
M. Alfonsi,
L. Arazi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
L. Buetikofer,
J. M. R. Cardoso,
D. Coderre,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowksi
, et al. (73 additional authors not shown)
Abstract:
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experime…
▽ More
The low-background, VUV-sensitive 3-inch diameter photomultiplier tube R11410 has been developed by Hamamatsu for dark matter direct detection experiments using liquid xenon as the target material. We present the results from the joint effort between the XENON collaboration and the Hamamatsu company to produce a highly radio-pure photosensor (version R11410-21) for the XENON1T dark matter experiment. After introducing the photosensor and its components, we show the methods and results of the radioactive contamination measurements of the individual materials employed in the photomultiplier production. We then discuss the adopted strategies to reduce the radioactivity of the various PMT versions. Finally, we detail the results from screening 216 tubes with ultra-low background germanium detectors, as well as their implications for the expected electronic and nuclear recoil background of the XENON1T experiment.
△ Less
Submitted 26 March, 2015;
originally announced March 2015.
-
The Electronics and Data Acquisition System of the DarkSide Dark Matter Search
Authors:
The DarkSide Collaboration,
P. Agnes,
T. Alexander,
A. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
A. Brigatti,
J. Brodsky,
F. Budano,
L. Cadonati,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
A. G. Cocco,
L. Crippa,
D. D'Angelo
, et al. (121 additional authors not shown)
Abstract:
It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del…
▽ More
It is generally inferred from astronomical measurements that Dark Matter (DM) comprises approximately 27\% of the energy-density of the universe. If DM is a subatomic particle, a possible candidate is a Weakly Interacting Massive Particle (WIMP), and the DarkSide-50 (DS) experiment is a direct search for evidence of WIMP-nuclear collisions. DS is located underground at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, and consists of three active, embedded components; an outer water veto (CTF), a liquid scintillator veto (LSV), and a liquid argon (LAr) time projection chamber (TPC). This paper describes the data acquisition and electronic systems of the DS detectors, designed to detect the residual ionization from such collisions.
△ Less
Submitted 22 January, 2015; v1 submitted 9 December, 2014;
originally announced December 2014.
-
Measurement of the absolute Quantum Efficiency of Hamamatsu model R11410-10 photomultiplier tubes at low temperatures down to liquid xenon boiling point
Authors:
Alexey Lyashenko,
Tam Nguyen,
Adam Snyder,
Hanguo Wang,
Katsushi Arisaka
Abstract:
We report on the measurements of the absolute Quantum Efficiency(QE) for Hamamatsu model R11410-10 PMTs specially designed for the use in low background liquid xenon detectors. QE was measured for five PMTs in a spectral range between 154.5 nm to 400 nm at low temperatures down to -110$^0$C. It was shown that during the PMT cooldown from room temperature to -110 $^0$C (a typical PMT operation temp…
▽ More
We report on the measurements of the absolute Quantum Efficiency(QE) for Hamamatsu model R11410-10 PMTs specially designed for the use in low background liquid xenon detectors. QE was measured for five PMTs in a spectral range between 154.5 nm to 400 nm at low temperatures down to -110$^0$C. It was shown that during the PMT cooldown from room temperature to -110 $^0$C (a typical PMT operation temperature in liquid xenon detectors), the absolute QE increases by a factor of 1.1 - 1.15 at 175 nm. The QE growth rate with respect to temperature is wavelength dependent peaking at about 165 nm corresponding to the fastest growth of about -0.07 %QE/$^{0}C$ and at about 200 nm corresponding to slowest growth of below -0.01 %QE/$^{0}C$. A dedicated setup and methods for PMT Quantum Efficiency measurement at low temperatures are described in details.
△ Less
Submitted 29 October, 2014; v1 submitted 14 October, 2014;
originally announced October 2014.
-
First Results from the DarkSide-50 Dark Matter Experiment at Laboratori Nazionali del Gran Sasso
Authors:
P. Agnes,
T. Alexander,
A. Alton,
K. Arisaka,
H. O. Back,
B. Baldin,
K. Biery,
G. Bonfini,
M. Bossa,
A. Brigatti,
J. Brodsky,
F. Budano,
L. Cadonati,
F. Calaprice,
N. Canci,
A. Candela,
H. Cao,
M. Cariello,
P. Cavalcante,
A. Chavarria,
A. Chepurnov,
A. G. Cocco,
L. Crippa,
D. D'Angelo,
M. D'Incecco
, et al. (121 additional authors not shown)
Abstract:
We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid sci…
▽ More
We report the first results of DarkSide-50, a direct search for dark matter operating in the underground Laboratori Nazionali del Gran Sasso (LNGS) and searching for the rare nuclear recoils possibly induced by weakly interacting massive particles (WIMPs). The dark matter detector is a Liquid Argon Time Projection Chamber with a (46.4+-0.7) kg active mass, operated inside a 30 t organic liquid scintillator neutron veto, which is in turn installed at the center of a 1 kt water Cherenkov veto for the residual flux of cosmic rays. We report here the null results of a dark matter search for a (1422+-67) kg d exposure with an atmospheric argon fill. This is the most sensitive dark matter search performed with an argon target, corresponding to a 90% CL upper limit on the WIMP-nucleon spin-independent cross section of 6.1x10^-44 cm^2 for a WIMP mass of 100 GeV/c^2.
△ Less
Submitted 27 February, 2015; v1 submitted 2 October, 2014;
originally announced October 2014.
-
Conceptual design and simulation of a water Cherenkov muon veto for the XENON1T experiment
Authors:
E. Aprile,
F. Agostini,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
M. Auger,
C. Balan,
P. Barrow,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Breskin,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni
, et al. (66 additional authors not shown)
Abstract:
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for W…
▽ More
XENON is a dark matter direct detection project, consisting of a time projection chamber (TPC) filled with liquid xenon as detection medium. The construction of the next generation detector, XENON1T, is presently taking place at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy. It aims at a sensitivity to spin-independent cross sections of $2 \cdot 10^{-47} ~ \mathrm{cm}^{\mathrm{2}}$ for WIMP masses around 50 GeV/c$^{2}$, which requires a background reduction by two orders of magnitude compared to XENON100, the current generation detector. An active system that is able to tag muons and muon-induced backgrounds is critical for this goal. A water Cherenkov detector of $\sim$10 m height and diameter has been therefore developed, equipped with 8 inch photomultipliers and cladded by a reflective foil. We present the design and optimization study for this detector, which has been carried out with a series of Monte Carlo simulations. The muon veto will reach very high detection efficiencies for muons ($>99.5%$) and showers of secondary particles from muon interactions in the rock ($>70%$). Similar efficiencies will be obtained for XENONnT, the upgrade of XENON1T, which will later improve the WIMP sensitivity by another order of magnitude. With the Cherenkov water shield studied here, the background from muon-induced neutrons in XENON1T is negligible.
△ Less
Submitted 25 February, 2015; v1 submitted 9 June, 2014;
originally announced June 2014.
-
Observation and applications of single-electron charge signals in the XENON100 experiment
Authors:
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
S. Bruenner,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (55 additional authors not shown)
Abstract:
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector…
▽ More
The XENON100 dark matter experiment uses liquid xenon in a time projection chamber (TPC) to measure xenon nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper, we report the observation of single-electron charge signals which are not related to WIMP interactions. These signals, which show the excellent sensitivity of the detector to small charge signals, are explained as being due to the photoionization of impurities in the liquid xenon and of the metal components inside the TPC. They are used as a unique calibration source to characterize the detector. We explain how we can infer crucial parameters for the XENON100 experiment: the secondary-scintillation gain, the extraction yield from the liquid to the gas phase and the electron drift velocity.
△ Less
Submitted 28 January, 2014; v1 submitted 5 November, 2013;
originally announced November 2013.
-
The neutron background of the XENON100 dark matter experiment
Authors:
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
A. Brown,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella,
W. Fulgione
, et al. (52 additional authors not shown)
Abstract:
The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($α$,n) and spontaneous fission re…
▽ More
The XENON100 experiment, installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. This paper presents a study on the nuclear recoil background of the experiment, taking into account neutron backgrounds from ($α$,n) and spontaneous fission reactions due to natural radioactivity in the detector and shield materials, as well as muon-induced neutrons. Based on Monte Carlo simulations and using measured radioactive contaminations of all detector components, we predict the nuclear recoil backgrounds for the WIMP search results published by the XENON100 experiment in 2011 and 2012, 0.11$^{+0.08}_{-0.04}$ events and 0.17$^{+0.12}_{-0.07}$ events, respectively, and conclude that they do not limit the sensitivity of the experiment.
△ Less
Submitted 2 September, 2013; v1 submitted 10 June, 2013;
originally announced June 2013.
-
The distributed Slow Control System of the XENON100 Experiment
Authors:
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. M. Bruno,
R. Budnik,
M. Le Calloch,
J. M. Cardoso,
W. -T. Chen,
B. Choi,
H. Contreras,
J. -P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella,
W. Fulgione,
F. Gao,
M. Garbini
, et al. (50 additional authors not shown)
Abstract:
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature…
▽ More
The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature. The system software was designed according to the rules of Object-Oriented Programming and coded in Java, thus promoting code reusability and maximum flexibility during commissioning of the experiment. The SCS has been continuously monitoring the XENON100 detector since mid 2008, remotely recording hundreds of parameters on a few dozen instruments in real time, and setting emergency alarms for the most important variables.
△ Less
Submitted 5 November, 2012;
originally announced November 2012.
-
Expected Sensitivity to Galactic/Solar Axions and Bosonic Super-WIMPs based on the Axio-electric Effect in Liquid Xenon Dark Matter Detectors
Authors:
K. Arisaka,
P. Beltrame,
C. Ghag,
J. Kaidi,
K. Lung,
A. Lyashenko,
R. D. Peccei,
P. Smith,
K. Ye
Abstract:
We present systematic case studies to investigate the sensitivity of axion searches by liquid xenon detectors, using the axio-electric effect (analogue of the photoelectric effect) on xenon atoms. Liquid xenon is widely considered to be one of the best target media for detection of WIMPs (Weakly Interacting Massive Particles which may form the galactic dark matter) using nuclear recoils. Since the…
▽ More
We present systematic case studies to investigate the sensitivity of axion searches by liquid xenon detectors, using the axio-electric effect (analogue of the photoelectric effect) on xenon atoms. Liquid xenon is widely considered to be one of the best target media for detection of WIMPs (Weakly Interacting Massive Particles which may form the galactic dark matter) using nuclear recoils. Since these detectors also provide an extremely low radioactivity environment for electron recoils, very weakly-interacting low-mass particles (< 100 keV/c^2), such as the hypothetical axion, could be detected as well - in this case using the axio-electric effect. Future ton-scale liquid Xe detectors will be limited in sensitivity only by irreducible neutrino background (pp-chain solar neutrino and the double beta decay of 136Xe) in the mass range between 1 and 100 keV/c^2. Assuming one ton-year of exposure, galactic axions (as non-relativistic dark matter) could be detected if the axio-electric coupling g_Ae is greater than 10^-14 at 1 keV/c^2 (or $10^-13 at 100 keV/c^2). Below a few keV/c^2, and independent of the mass, a solar axion search would be sensitive to a coupling g_Ae ~ 10^-12. This limit will set a stringent upper bound on axion mass for the DFSV and KSVZ models for the mass ranges m_A < 0.1 eV/c^2 and < 10 eV/c^2, respectively. Vector-boson dark matter could also be detected for a coupling constant alpha'/alpha > 10^-33 (for mass 1 keV/c^2) or > 10^-27 (for mass 100 keV/c^2).
△ Less
Submitted 23 January, 2013; v1 submitted 17 September, 2012;
originally announced September 2012.
-
Dark Matter Results from 225 Live Days of XENON100 Data
Authors:
XENON100 Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
B. Bauermeister,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. Cline,
A. P. Colijn,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella
, et al. (53 additional authors not shown)
Abstract:
We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence…
▽ More
We report on a search for particle dark matter with the XENON100 experiment, operated at the Laboratori Nazionali del Gran Sasso (LNGS) for 13 months during 2011 and 2012. XENON100 features an ultra-low electromagnetic background of (5.3 \pm 0.6) \times 10^-3 events (kg day keVee)^-1 in the energy region of interest. A blind analysis of 224.6 live days \times 34 kg exposure has yielded no evidence for dark matter interactions. The two candidate events observed in the pre-defined nuclear recoil energy range of 6.6-30.5 keVnr are consistent with the background expectation of (1.0 \pm 0.2) events. A Profile Likelihood analysis using a 6.6-43.3 keVnr energy range sets the most stringent limit on the spin-independent elastic WIMP-nucleon scattering cross section for WIMP masses above 8 GeV/c^2, with a minimum of 2 \times 10^-45 cm^2 at 55 GeV/c^2 and 90% confidence level.
△ Less
Submitted 20 March, 2013; v1 submitted 25 July, 2012;
originally announced July 2012.
-
Analysis of the XENON100 Dark Matter Search Data
Authors:
The XENON100 Collaboration,
E. Aprile,
M. Alfonsi,
K. Arisaka,
F. Arneodo,
C. Balan,
L. Baudis,
A. Behrens,
P. Beltrame,
K. Bokeloh,
E. Brown,
G. Bruno,
R. Budnik,
J. M. R. Cardoso,
W. -T. Chen,
B. Choi,
D. B. Cline,
H. Contreras,
J. P. Cussonneau,
M. P. Decowski,
E. Duchovni,
S. Fattori,
A. D. Ferella,
W. Fulgione,
F. Gao
, et al. (49 additional authors not shown)
Abstract:
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have…
▽ More
The XENON100 experiment, situated in the Laboratori Nazionali del Gran Sasso, aims at the direct detection of dark matter in the form of weakly interacting massive particles (WIMPs), based on their interactions with xenon nuclei in an ultra low background dual-phase time projection chamber. This paper describes the general methods developed for the analysis of the XENON100 data. These methods have been used in the 100.9 and 224.6 live days science runs from which results on spin-independent elastic, spin-dependent elastic and inelastic WIMP-nucleon cross-sections have already been reported.
△ Less
Submitted 14 October, 2013; v1 submitted 14 July, 2012;
originally announced July 2012.
-
Characterization of the Hamamatsu R11410-10 3-Inch Photomultiplier Tube for Liquid Xenon Dark Matter Direct Detection Experiments
Authors:
K. Lung,
K. Arisaka,
A. Bargetzi,
P. Beltrame,
A. Cahill,
T. Genma,
C. Ghag,
D. Gordon,
J. Sainz,
A. Teymourian,
Y. Yoshizawa
Abstract:
To satisfy the requirements of the next generation of dark matter detectors based on the dual phase TPC, Hamamatsu, in close collaboration with UCLA, has developed the R11410-10 photomultipler tube. In this work, we present the detailed tests performed on this device. High QE (>30%) accompanied by a low dark count rate (50 Hz at 0.3 PE) and high gain (10^7) with good single PE resolution have been…
▽ More
To satisfy the requirements of the next generation of dark matter detectors based on the dual phase TPC, Hamamatsu, in close collaboration with UCLA, has developed the R11410-10 photomultipler tube. In this work, we present the detailed tests performed on this device. High QE (>30%) accompanied by a low dark count rate (50 Hz at 0.3 PE) and high gain (10^7) with good single PE resolution have been observed. A comprehensive screening measurement campaign is ongoing while the manufacturer quotes a radioactivity of 20 mBq/PMT. These characteristics show the R11410-10 to be particularly suitable for the forthcoming zero background liquid xenon detectors.
△ Less
Submitted 23 August, 2012; v1 submitted 12 February, 2012;
originally announced February 2012.
-
A New Analysis Method for WIMP searches with Dual-Phase Liquid Xe TPCs
Authors:
K. Arisaka,
P. Beltrame,
C. Ghag,
K. Lung,
P. R. Scovell
Abstract:
A new data analysis method based on physical observables for WIMP dark matter searches with noble liquid Xe dual-phase TPCs is presented. Traditionally, the nuclear recoil energy from a scatter in the liquid target has been estimated by means of the initial prompt scintillation light (S1) produced at the interaction vertex. The ionization charge (C2), or its secondary scintillation (S2), is combin…
▽ More
A new data analysis method based on physical observables for WIMP dark matter searches with noble liquid Xe dual-phase TPCs is presented. Traditionally, the nuclear recoil energy from a scatter in the liquid target has been estimated by means of the initial prompt scintillation light (S1) produced at the interaction vertex. The ionization charge (C2), or its secondary scintillation (S2), is combined with the primary scintillation in Log(S2/S1) vs. S1 only as a discrimination parameter against electron recoil background. Arguments in favor of C2 as the more reliable nuclear recoil energy estimator than S1 are presented. The new phase space of Log(S1/C2) vs. C2 is introduced as more efficient for nuclear recoil acceptance and exhibiting superior energy resolution. This is achieved without compromising the discrimination power of the LXe TPC, nor its 3D event reconstruction and fiducialization capability, as is the case for analyses that exploit only the ionization channel. Finally, the concept of two independent energy estimators for background rejection is presented: E2 as the primary (based on C2) and E1 as the secondary (based on S1). Log(E1/E2) vs. E2 is shown to be the most appropriate phase space in which to evaluate WIMP signal candidates.
△ Less
Submitted 22 June, 2012; v1 submitted 9 February, 2012;
originally announced February 2012.
-
Studies of a three-stage dark matter and neutrino observatory based on multi-ton combinations of liquid xenon and liquid argon detectors
Authors:
K. Arisaka,
P. Beltrame,
C. W. Lam,
P. F. Smith,
C. Ghag,
D. B. Cline,
K. Lung,
Y. Meng,
E. Pantic,
P. R. Scovell,
A. Teymourian,
H. Wang
Abstract:
We study a three stage dark matter and neutrino observatory based on multi-ton two-phase liquid Xe and Ar detectors with sufficiently low backgrounds to be sensitive to WIMP dark matter interaction cross sections down to 10E-47 cm^2, and to provide both identification and two independent measurements of the WIMP mass through the use of the two target elements in a 5:1 mass ratio, giving an expecte…
▽ More
We study a three stage dark matter and neutrino observatory based on multi-ton two-phase liquid Xe and Ar detectors with sufficiently low backgrounds to be sensitive to WIMP dark matter interaction cross sections down to 10E-47 cm^2, and to provide both identification and two independent measurements of the WIMP mass through the use of the two target elements in a 5:1 mass ratio, giving an expected similarity of event numbers. The same detection systems will also allow measurement of the pp solar neutrino spectrum, the neutrino flux and temperature from a Galactic supernova, and neutrinoless double beta decay of 136Xe to the lifetime level of 10E27 - 10E28 y corresponding to the Majorana mass predicted from current neutrino oscillation data. The proposed scheme would be operated in three stages G2, G3, G4, beginning with fiducial masses 1-ton Xe + 5-ton Ar (G2), progressing to 10-ton Xe + 50-ton Ar (G3) then, dependent on results and performance of the latter, expandable to 100-ton Xe + 500-ton Ar (G4). This method of scale-up offers the advantage of utilizing the Ar vessel and ancillary systems of one stage for the Xe detector of the succeeding stage, requiring only one new detector vessel at each stage. Simulations show the feasibility of reducing or rejecting all external and internal background levels to a level <1 events per year for each succeeding mass level, by utilizing an increasing outer thickness of target material as self-shielding. The system would, with increasing mass scale, become increasingly sensitive to annual signal modulation, the agreement of Xe and Ar results confirming the Galactic origin of the signal. Dark matter sensitivities for spin-dependent and inelastic interactions are also included, and we conclude with a discussion of possible further gains from the use of Xe/Ar mixtures.
△ Less
Submitted 15 April, 2012; v1 submitted 7 July, 2011;
originally announced July 2011.
-
Material screening and selection for XENON100
Authors:
XENON100 Collaboration,
E. Aprile,
K. Arisaka,
F. Arneodo,
A. Askin,
L. Baudis,
A. Behrens,
K. Bokeloh,
E. Brown,
J. M. R. Cardoso,
B. Choi,
D. Cline,
S. Fattori,
A. D. Ferella,
K. L. Giboni,
A. Kish,
C. W. Lam,
J. Lamblin,
R. F. Lang,
K. E. Lim,
J. A. M. Lopes,
T. Marrodan Undagoitia,
Y. Mei,
A. J. Melgarejo Fernandez,
K. Ni
, et al. (16 additional authors not shown)
Abstract:
Results of the extensive radioactivity screening campaign to identify materials for the construction of XENON100 are reported. This Dark Matter search experiment is operated underground at Laboratori Nazionali del Gran Sasso (LNGS), Italy. Several ultra sensitive High Purity Germanium detectors (HPGe) have been used for gamma ray spectrometry. Mass spectrometry has been applied for a few low mass…
▽ More
Results of the extensive radioactivity screening campaign to identify materials for the construction of XENON100 are reported. This Dark Matter search experiment is operated underground at Laboratori Nazionali del Gran Sasso (LNGS), Italy. Several ultra sensitive High Purity Germanium detectors (HPGe) have been used for gamma ray spectrometry. Mass spectrometry has been applied for a few low mass plastic samples. Detailed tables with the radioactive contaminations of all screened samples are presented, together with the implications for XENON100.
△ Less
Submitted 22 June, 2011; v1 submitted 30 March, 2011;
originally announced March 2011.
-
Characterization of the QUartz Photon Intensifying Detector (QUPID) for Noble Liquid Detectors
Authors:
A. Teymourian,
D. Aharoni,
L. Baudis,
P. Beltrame,
E. Brown,
D. Cline,
A. D. Ferella,
A. Fukasawa,
C. W. Lam,
T. Lim,
K. Lung,
Y. Meng,
S. Muramatsu,
E. Pantic,
M. Suyama,
H. Wang,
K. Arisaka
Abstract:
Dark Matter and Double Beta Decay experiments require extremely low radioactivity within the detector materials. For this purpose, the University of California, Los Angeles and Hamamatsu Photonics have developed the QUartz Photon Intensifying Detector (QUPID), an ultra-low background photodetector based on the Hybrid Avalanche Photo Diode (HAPD) and entirely made of ultraclean synthetic fused sili…
▽ More
Dark Matter and Double Beta Decay experiments require extremely low radioactivity within the detector materials. For this purpose, the University of California, Los Angeles and Hamamatsu Photonics have developed the QUartz Photon Intensifying Detector (QUPID), an ultra-low background photodetector based on the Hybrid Avalanche Photo Diode (HAPD) and entirely made of ultraclean synthetic fused silica. In this work we present the basic concept of the QUPID and the testing measurements on QUPIDs from the first production line. Screening of radioactivity at the Gator facility in the Laboratori Nazionali del Gran Sasso has shown that the QUPIDs safely fulfill the low radioactive contamination requirements for the next generation zero background experiments set by Monte Carlo simulations. The quantum efficiency of the QUPID at room temperature is > 30% at the xenon scintillation wavelength. At low temperatures, the QUPID shows a leakage current less than 1 nA and a global gain of 10^5. In these conditions, the photocathode and the anode show > 95% linearity up to 1 uA for the cathode and 3 mA for the anode. The photocathode and collection efficiency are uniform to 80% over the entire surface. In parallel with single photon counting capabilities, the QUPIDs have a good timing response: 1.8 +/- 0.1 ns rise time, 2.5 +/- 0.2 ns fall time, 4.20 +/- 0.05 ns pulse width, and 160 +/- 30 ps transit time spread. The QUPIDs have also been tested in a liquid xenon environment, and scintillation light from 57Co and 210Po radioactive sources were observed.
△ Less
Submitted 15 July, 2011; v1 submitted 18 March, 2011;