-
Multi-scale simulation of red blood cell trauma in large-scale high-shear flows after Norwood operation
Authors:
Saba Mansour,
Emily Logan,
James F. Antaki,
Mahdi Esmaily
Abstract:
Cardiovascular surgeries and mechanical circulatory support devices create non-physiological blood flow conditions that can be detrimental, especially for pediatric patients. A source of complications is mechanical red blood cell (RBC) damage induced by the localized supraphysiological shear fields. To understand such complications, we introduce a multi-scale numerical model to predict the risk of…
▽ More
Cardiovascular surgeries and mechanical circulatory support devices create non-physiological blood flow conditions that can be detrimental, especially for pediatric patients. A source of complications is mechanical red blood cell (RBC) damage induced by the localized supraphysiological shear fields. To understand such complications, we introduce a multi-scale numerical model to predict the risk of hemolysis in a set of idealized anatomies. We employed our in-house CFD solver coupled with Lagrangian tracking and cell-resolved fluid-structure interaction to measure flow-induced stresses and strains on the RBC membrane. The Norwood procedure, well-known to be associated with high mortality rate, is selected for its importance in the survival of the single-ventricle population. We simulated three anatomies including 2.5mm and 4.0mm diameter modified Blalock-Taussig (BT) shunts and a 2.5mm central shunt (CS), with hundreds of RBCs in each case for statistical analysis. The results show that the conditions created by these surgeries can elongate RBCs by more than two-fold (3.1% of RBCs for 2.5mm BT shunt, 1.4% for 4mm BT shunt, and 8.8% for CS). Shear and areal strain metrics also reveal that the central shunt creates the greatest deformations on the RBCs membrane, indicating it is a more hemolytic procedure in comparison to the BT shunt. Between the two BT shunts, the smaller diameter is slightly more prone to hemolysis. These conclusions are confirmed when strain history and different damage thresholds are considered. The spatial damage maps produced based on these metrics highlighted hot zones that match the clinical images of shunt thrombosis.
△ Less
Submitted 19 November, 2024;
originally announced November 2024.
-
Exploratory Simulation of Thrombosis in a Temporary LVAD Catheter Pump within a Virtual In-vivo Left Heart Environment
Authors:
Greg W. Burgreen,
Mansur Zhussupbekov,
Rodrigo Méndez Rojano,
James F. Antaki
Abstract:
Percutaneous catheter pumps are intraventricular temporary mechanical circulatory support (MCS) devices that are positioned across the aortic valve into the left ventricle (LV) and provide continuous antegrade blood flow from the LV into the ascending aorta (AA). MCS devices are most often computationally evaluated as isolated devices subject to idealized steady-state blood flow conditions. In cli…
▽ More
Percutaneous catheter pumps are intraventricular temporary mechanical circulatory support (MCS) devices that are positioned across the aortic valve into the left ventricle (LV) and provide continuous antegrade blood flow from the LV into the ascending aorta (AA). MCS devices are most often computationally evaluated as isolated devices subject to idealized steady-state blood flow conditions. In clinical practice, MCS devices operate connected to or within diseased pulsatile native hearts and are often complicated by hemocompatibility related adverse events such as stroke, bleeding, and thrombosis. Whereas aspects of the human circulation are increasingly being simulated via computational methods, the precise interplay of pulsatile LV hemodynamics with MCS pump hemocompatibility remains mostly unknown and not well characterized. Technologies are rapidly converging such that next-generation MCS devices will soon be evaluated in virtual physiological environments that increasingly mimic clinical settings. The purpose of this brief communication is to report results and lessons learned from an exploratory CFD simulation of hemodynamics and thrombosis for a catheter pump situated within a virtual in-vivo left heart environment.
△ Less
Submitted 7 December, 2023;
originally announced December 2023.
-
In Vitro and In Silico Characterization of the Aggregation of Thrombi on Ventricular Assist Device Cannula
Authors:
Wenxuan He,
Abhishek Karmakar,
Grant Rowlands,
Samuel Schirmacher,
Rodrigo Méndez-Rojano,
James F. Antaki
Abstract:
The unacceptably high stroke rate of HeartMate III VAD without signs of adherent pump thrombosis is hypothesized to be the result of the thrombi originating on the inflow cannula, ingesting and ejecting emboli from the VAD. Therefore, inflow cannula thrombosis has been an emerging focus. The inflow cannula of contemporary VADs, which incorporate both polished and rough regions serve as useful benc…
▽ More
The unacceptably high stroke rate of HeartMate III VAD without signs of adherent pump thrombosis is hypothesized to be the result of the thrombi originating on the inflow cannula, ingesting and ejecting emboli from the VAD. Therefore, inflow cannula thrombosis has been an emerging focus. The inflow cannula of contemporary VADs, which incorporate both polished and rough regions serve as useful benchmarks to study the effects of roughness and shear on thrombogenesis. An in vitro study was conducted to emulate the micro-hemodynamic condition on a sintered inflow cannula, and to observe the deposition and detachment patterns. Together with a computational fluid dynamic tool, this study aimed to provide insight into the optimization of inflow cannula and potentially reducing adverse neurological events due to upstream thrombus.
△ Less
Submitted 6 October, 2023;
originally announced October 2023.
-
Automated CFD shape optimization of stator blades for the PediaFlow pediatric ventricular assist device
Authors:
Mansur Zhussupbekov,
Greg W Burgreen,
Jeongho Kim,
James F Antaki
Abstract:
PediaFlow is a miniature mixed-flow ventricular assist device for neonates and toddlers. PediaFlow has a fully magnetically levitated rotor which improves biocompatibility, but the increased length of the rotor creates a long annular passage where fluid energy is lost. Therefore, a set of helical stator blades was proposed immediately after the impeller stage to remove the swirling flow and recove…
▽ More
PediaFlow is a miniature mixed-flow ventricular assist device for neonates and toddlers. PediaFlow has a fully magnetically levitated rotor which improves biocompatibility, but the increased length of the rotor creates a long annular passage where fluid energy is lost. Therefore, a set of helical stator blades was proposed immediately after the impeller stage to remove the swirling flow and recover the dynamic head as static pressure. Automated computational fluid dynamics (CFD) shape optimization of the stator blades was performed to maximize pressure recovery at the operating point of 1.5 LPM and 16,000 RPM. Additionally, the effect on hemolysis and thrombogenicity was assessed using numerical modeling. The optimization algorithm favored fewer blades of greater length over a larger number of short blades. The ratio of wrap angle to axial length emerged as a key constraint to ensure the viability of a design. The best design had 2 blades and generated 73 mmHg of pressure recovery in an isolated stage. When re-introduced to the CFD simulation of the complete flow path, the added stator stage increased the pump head by 46% and improved the pump efficiency from 21.9% to 25.7% at the selected operating point. Automated CFD shape optimization combined with in silico evaluation of hemocompatibility can be an effective tool for exploring design choices and informing early development process.
△ Less
Submitted 8 November, 2022;
originally announced November 2022.
-
von Willebrand Factor unfolding mediates platelet deposition in a model of high-shear thrombosis
Authors:
Mansur Zhussupbekov,
Rodrigo Mendez Rojano,
Wei-Tao Wu,
James F Antaki
Abstract:
Thrombosis under high-shear conditions is mediated by the mechanosensitive blood glycoprotein von Willebrand Factor (vWF). vWF unfolds in response to strong flow gradients and facilitates rapid recruitment of platelets in flowing blood. While the thrombogenic effect of vWF is well recognized, its conformational response in complex flows has largely been omitted from numerical models of thrombosis.…
▽ More
Thrombosis under high-shear conditions is mediated by the mechanosensitive blood glycoprotein von Willebrand Factor (vWF). vWF unfolds in response to strong flow gradients and facilitates rapid recruitment of platelets in flowing blood. While the thrombogenic effect of vWF is well recognized, its conformational response in complex flows has largely been omitted from numerical models of thrombosis. We recently presented a continuum model for the unfolding of vWF, where we represented vWF transport and its flow-induced conformational change using convection-diffusion-reaction equations. Here, we incorporate the vWF component into our multi-constituent model of thrombosis, where the local concentration of stretched vWF amplifies the deposition rate of free-flowing platelets and reduces the shear cleaning of deposited platelets. We validate the model using three benchmarks: in vitro model of atherothrombosis, a stagnation point flow, and the PFA-100, a clinical blood test commonly used for screening for von Willebrand Disease (vWD). The simulations reproduced the key aspects of vWF-mediated thrombosis observed in these experiments, such as the thrombus location, thrombus growth dynamics, and the effect of blocking platelet-vWF interactions. The PFA-100 simulations closely matched the reported occlusion times for normal blood and several hemostatic deficiencies, namely, thrombocytopenia, vWD Type 1, and vWD Type 3. Overall, the multi-constituent model of thrombosis presented in this work enables macro-scale 3-D simulations of thrombus formation in complex geometries over a wide range of shear rates and accounts for qualitative and quantitative hemostatic deficiencies in patient blood. The results also demonstrate the utility of the continuum model of vWF unfolding that could be adapted to other numerical models of thrombosis.
△ Less
Submitted 30 September, 2022; v1 submitted 8 April, 2022;
originally announced April 2022.
-
A continuum model for the unfolding of von Willebrand Factor
Authors:
Mansur Zhussupbekov,
Rodrigo Mendez Rojano,
Wei-Tao Wu,
Mehrdad Massoudi,
James F. Antaki
Abstract:
von Willebrand Factor is a mechano-sensitive protein circulating in blood that mediates platelet adhesion to subendothelial collagen and platelet aggregation at high shear rates. Its hemostatic function and thrombogenic effect, as well as susceptibility to enzymatic cleavage, are regulated by a conformational change from a collapsed globular state to a stretched state. Therefore, it is essential t…
▽ More
von Willebrand Factor is a mechano-sensitive protein circulating in blood that mediates platelet adhesion to subendothelial collagen and platelet aggregation at high shear rates. Its hemostatic function and thrombogenic effect, as well as susceptibility to enzymatic cleavage, are regulated by a conformational change from a collapsed globular state to a stretched state. Therefore, it is essential to account for the conformation of the vWF multimers when modeling vWF-mediated thrombosis or vWF degradation. We introduce a continuum model of vWF unfolding that is developed within the framework of our multi-constituent model of platelet-mediated thrombosis. The model considers two interconvertible vWF species corresponding to the collapsed and stretched conformational states. vWF unfolding takes place via two regimes: tumbling in simple shear and strong unfolding in flows with dominant extensional component. These two regimes were demonstrated in a Couette flow between parallel plates and an extensional flow in a cross-slot geometry. The vWF unfolding model was then verified in several microfluidic systems designed for inducing high-shear vWF-mediated thrombosis and screening for von Willebrand Disease. The model predicted high concentration of stretched vWF in key regions where occlusive thrombosis was observed experimentally. Strong unfolding caused by the extensional flow was limited to the center axis or middle plane of the channels, whereas vWF unfolding near the channel walls relied upon the shear tumbling mechanism. The continuum model of vWF unfolding presented in this work can be employed in numerical simulations of vWF-mediated thrombosis or vWF degradation in complex geometries. However, extending the model to 3-D arbitrary flows and turbulent flows will pose considerable challenges.
△ Less
Submitted 11 August, 2021; v1 submitted 5 August, 2021;
originally announced August 2021.
-
Influence of shear rate and surface chemistry on thrombus formation in micro-crevice
Authors:
Mansur Zhussupbekov,
Wei-Tao Wu,
Megan A. Jamiolkowski,
Mehrdad Massoudi,
James F. Antaki
Abstract:
Thromboembolic complications remain a central issue in management of patients on mechanical circulatory support. Despite the best practices employed in design and manufacturing of modern ventricular assist devices, complexity and modular nature of these systems often introduces internal steps and crevices in the flow path which can serve as nidus for thrombus formation. Thrombotic potential is inf…
▽ More
Thromboembolic complications remain a central issue in management of patients on mechanical circulatory support. Despite the best practices employed in design and manufacturing of modern ventricular assist devices, complexity and modular nature of these systems often introduces internal steps and crevices in the flow path which can serve as nidus for thrombus formation. Thrombotic potential is influenced by multiple factors including the characteristics of the flow and surface chemistry of the biomaterial. This study explored these elements in the setting of blood flow over a micro-crevice using a multi-constituent numerical model of thrombosis. The simulations reproduced the platelet deposition patterns observed experimentally and elucidated the role of flow, shear rate, and surface chemistry in shaping the deposition. The results offer insights for design and operation of blood-contacting devices.
△ Less
Submitted 1 April, 2021; v1 submitted 20 November, 2020;
originally announced November 2020.
-
A non-linear fluid suspension model for blood flow
Authors:
Wei-Tao Wu,
Nadine Aubry,
James F. Antaki,
Mehrdad Massoudi
Abstract:
Motivated by the complex rheological behaviors observed in small/micro scale blood vessels, such as the Fahraeus effect, plasma-skimming, shear-thinning, etc., we develop a non-linear suspension model for blood. The viscosity is assumed to depend on the volume fraction (hematocrit) and the shear rate. The migration of the red blood cells (RBCs) is studied using a concentration flux equation. A par…
▽ More
Motivated by the complex rheological behaviors observed in small/micro scale blood vessels, such as the Fahraeus effect, plasma-skimming, shear-thinning, etc., we develop a non-linear suspension model for blood. The viscosity is assumed to depend on the volume fraction (hematocrit) and the shear rate. The migration of the red blood cells (RBCs) is studied using a concentration flux equation. A parametric study with two representative problems, namely simple shear flow and a pressure driven flow demonstrate the ability of this reduced-order model to reproduce several key features of the two-fluid model (mixture theory approach), with much lower computational cost.
△ Less
Submitted 10 September, 2018; v1 submitted 24 August, 2018;
originally announced August 2018.
-
Transport of platelets induced by red blood cells based on mixture theory
Authors:
Wei-Tao Wu,
Nadine Aubry,
James F. Antaki,
Mehrdad Massoudi
Abstract:
Thrombosis is a common complication following the surgical implantation of blood contacting devices, and is strongly influenced by the phenomenon of near-wall enrichment of platelets. This paper describes a multi-constituent continuum approach to study this phenomenon. A mixture-theory model is used to describe the motion of the plasma and the red blood cells (RBCs) and the interactions between th…
▽ More
Thrombosis is a common complication following the surgical implantation of blood contacting devices, and is strongly influenced by the phenomenon of near-wall enrichment of platelets. This paper describes a multi-constituent continuum approach to study this phenomenon. A mixture-theory model is used to describe the motion of the plasma and the red blood cells (RBCs) and the interactions between the two components. A transport model is developed to study the influence of the RBC field on the platelets. The model is used to study blood flow in a rectangular micro-channel, a sudden expansion micro-channel, and a channel containing micro crevices (representing a practical problem encountered in most blood-wetted devices). The simulations show that in the rectangular channel the concentration of platelets near the walls is about five times higher than the concentration near the centerline of the channel. It is also noticed that in the channel with crevices, extremely a large number of platelets accumulate in the deep part of the crevices and this may serve as the nidus for thrombosis occurring in medical devices.
Keywords: Platelets; Blood flow; RBCs; Micro-channel; Mixture theory; Two-fluids; Thrombosis
△ Less
Submitted 7 May, 2017; v1 submitted 1 March, 2017;
originally announced March 2017.
-
Normal stress effects in the gravity driven flow of granular materials
Authors:
Wei-Tao Wu,
Nadine Aubry,
James F. Antaki,
Mehrdad Massoudi
Abstract:
In this paper, we study the fully developed gravity-driven flow of granular materials between two inclined planes. We assume that the granular materials can be represented by a modified form of the second-grade fluid where the viscosity depends on the shear rate and volume fraction and the normal stress coefficients depend on the volume fraction. We also propose a new isotropic (spherical) part of…
▽ More
In this paper, we study the fully developed gravity-driven flow of granular materials between two inclined planes. We assume that the granular materials can be represented by a modified form of the second-grade fluid where the viscosity depends on the shear rate and volume fraction and the normal stress coefficients depend on the volume fraction. We also propose a new isotropic (spherical) part of the stress tensor which can be related to the compactness of the (rigid) particles. This new term ensures that the rigid solid particles cannot be compacted beyond a point, namely when the volume fraction has reached the critical/maximum packing value. The numerical results indicate that the newly proposed stress tensor has an obvious and physically meaningful effects on both the velocity and the volume fraction fields.
△ Less
Submitted 10 February, 2017; v1 submitted 6 February, 2017;
originally announced February 2017.
-
Multi-Constituent Simulation of Thrombus Deposition
Authors:
Wei-Tao Wu,
Megan A. Jamiolkowski,
William R. Wagner,
Nadine Aubry,
Mehrdad Massoudi,
James F. Antaki
Abstract:
In this paper, we present a spatio-temporal mathematical model for simulating the formation and growth of a thrombus. Blood is treated as a multi-constituent mixture comprised of a linear fluid phase and a thrombus (solid) phase. The transport and reactions of 10 chemical and biological species are incorporated using a system of coupled convection-reaction-diffusion (CRD) equations to represent th…
▽ More
In this paper, we present a spatio-temporal mathematical model for simulating the formation and growth of a thrombus. Blood is treated as a multi-constituent mixture comprised of a linear fluid phase and a thrombus (solid) phase. The transport and reactions of 10 chemical and biological species are incorporated using a system of coupled convection-reaction-diffusion (CRD) equations to represent three processes in thrombus formation: initiation, propagation and stabilization. Computational fluid dynamic (CFD) simulations using the libraries of OpenFOAM were performed for two illustrative benchmark problems: in vivo thrombus growth in an injured blood vessel and in vitro thrombus deposition in micro-channels (1.5mm x 1.6mm x 0.1mm) with small crevices (125μm x 75μm and 125μm x 137μm). For both problems, the simulated thrombus deposition agreed very well with experimental observations, both spatially and temporally. Based on the success with these two benchmark problems, which have very different flow conditions and biological environments, we believe that the current model will provide useful insight into the genesis of thrombosis in blood-wetted devices, and provide a tool for the design of less thrombogenic devices.
△ Less
Submitted 1 December, 2016; v1 submitted 25 January, 2016;
originally announced January 2016.