Skip to main content

Showing 1–16 of 16 results for author: Angelico, E

Searching in archive physics. Search in all archives.
.
  1. arXiv:2504.15464  [pdf, other

    physics.ins-det hep-ex

    Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system

    Authors: nEXO Collaboration, A. Anker, P. A. Breur, B. Mong, P. Acharya, A. Amy, E. Angelico, I. J. Arnquist, A. Atencio, J. Bane, V. Belov, E. P. Bernard, T. Bhatta, A. Bolotnikov, J. Breslin, J. P. Brodsky, S. Bron, E. Brown, T. Brunner, B. Burnell, E. Caden, L. Q. Cao, G. F. Cao, D. Cesmecioglu, D. Chernyak , et al. (116 additional authors not shown)

    Abstract: Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC)… ▽ More

    Submitted 24 April, 2025; v1 submitted 21 April, 2025; originally announced April 2025.

    Comments: 14 pages, 9 figures, 1 table

  2. arXiv:2407.09575  [pdf, other

    physics.ins-det hep-ex

    Design of an 8-Channel 40 GS/s 20 mW/Ch Waveform Sampling ASIC in 65 nm CMOS

    Authors: Jinseo Park, Evan Angelico, Andrew Arzac, Davide Braga, Ahan Datta, Troy England, Camden Ertley, Farah Fahim, Henry J. Frisch, Mary Heintz, Eric Oberla, Nathaniel J. Pastika, Hector D. Rico-Aniles, Paul M. Rubinov, Xiaoran Wang, Yui Man Richmond Yeung, Tom N. Zimmerman

    Abstract: 1 ps timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe a preliminary design for PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in the TSMC 65 nm process targetting 1 ps resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing ps… ▽ More

    Submitted 17 July, 2024; v1 submitted 11 July, 2024; originally announced July 2024.

    Comments: 16th Pisa Meeting on Advanced Detectors

  3. arXiv:2407.00285  [pdf, other

    physics.atom-ph hep-ex nucl-ex

    Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment

    Authors: M. Yvaine, D. Fairbank, J. Soderstrom, C. Taylor, J. Stanley, T. Walton, C. Chambers, A. Iverson, W. Fairbank, S. Al Kharusi, A. Amy, E. Angelico, A. Anker, I. J. Arnquist, A. Atencio, J. Bane, V. Belov, E. P. Bernard, T. Bhatta, A. Bolotnikov, J. Breslin, P. A. Breur, J. P. Brodsky, E. Brown, T. Brunner , et al. (112 additional authors not shown)

    Abstract: Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s… ▽ More

    Submitted 28 June, 2024; originally announced July 2024.

    Comments: 9 pages, 8 figures

  4. arXiv:2305.07173  [pdf

    physics.med-ph hep-ex

    Simulation of a Compton-based detector for low-dose high-resolution time-of-flight positron emission tomography

    Authors: Kepler Domurat-Sousa, Cameron M. Poe, Maya S. McDaniel, Eric Spieglan, Joao F. Shida, Evan Angelico, Bernhard W. Adams, Patrick J. La Riviere, Henry J. Frisch, Allison H. Squires

    Abstract: Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scatte… ▽ More

    Submitted 3 January, 2024; v1 submitted 11 May, 2023; originally announced May 2023.

    Comments: 25 pages, 9 figures

  5. arXiv:2304.06180  [pdf, other

    physics.ins-det nucl-ex

    An integrated online radioassay data storage and analytics tool for nEXO

    Authors: R. H. M. Tsang, A. Piepke, S. Al Kharusi, E. Angelico, I. J. Arnquist, A. Atencio, I. Badhrees, J. Bane, V. Belov, E. P. Bernard, A. Bhat, T. Bhatta, A. Bolotnikov, P. A. Breur, J. P. Brodsky, E. Brown, T. Brunner, E. Caden, G. F. Cao, L. Q. Cao, D. Cesmecioglu, C. Chambers, E. Chambers, B. Chana, S. A. Charlebois , et al. (135 additional authors not shown)

    Abstract: Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa… ▽ More

    Submitted 20 June, 2023; v1 submitted 12 April, 2023; originally announced April 2023.

  6. Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO

    Authors: G. Gallina, Y. Guan, F. Retiere, G. Cao, A. Bolotnikov, I. Kotov, S. Rescia, A. K. Soma, T. Tsang, L. Darroch, T. Brunner, J. Bolster, J. R. Cohen, T. Pinto Franco, W. C. Gillis, H. Peltz Smalley, S. Thibado, A. Pocar, A. Bhat, A. Jamil, D. C. Moore, G. Adhikari, S. Al Kharusi, E. Angelico, I. J. Arnquist , et al. (140 additional authors not shown)

    Abstract: Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with… ▽ More

    Submitted 25 November, 2022; v1 submitted 16 September, 2022; originally announced September 2022.

  7. arXiv:2201.04681  [pdf, other

    physics.ins-det nucl-ex

    Development of a $^{127}$Xe calibration source for nEXO

    Authors: B. G. Lenardo, C. A. Hardy, R. H. M. Tsang, J. C. Nzobadila Ondze, A. Piepke, S. Triambak, A. Jamil, G. Adhikari, S. Al Kharusi, E. Angelico, I. J. Arnquist, V. Belov, E. P. Bernard, A. Bhat, T. Bhatta, A. Bolotnikov, P. A. Breur, J. P. Brodsky, E. Brown, T. Brunner, E. Caden, G. F. Cao, L. Cao, B. Chana, S. A. Charlebois , et al. (103 additional authors not shown)

    Abstract: We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and… ▽ More

    Submitted 12 January, 2022; originally announced January 2022.

    Comments: 24 pages, 16 figures

  8. arXiv:2108.01715  [pdf, other

    physics.ins-det physics.med-ph

    Low-Dose High-Resolution TOF-PET Using Ionization-activated Multi-State Low-Z Detector Media

    Authors: Joao Francisco Shida, Eric Spieglan, Bernhard W. Adams, Evan Angelico, Kepler Domurat-Sousa, Andrey Elagin, Henry J. Frisch, Patrick La Riviere, Allison H. Squires

    Abstract: We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatter… ▽ More

    Submitted 3 August, 2021; originally announced August 2021.

  9. arXiv:2106.16243  [pdf, other

    nucl-ex physics.ins-det

    NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity

    Authors: nEXO Collaboration, G. Adhikari, S. Al Kharusi, E. Angelico, G. Anton, I. J. Arnquist, I. Badhrees, J. Bane, V. Belov, E. P. Bernard, T. Bhatta, A. Bolotnikov, P. A. Breur, J. P. Brodsky, E. Brown, T. Brunner, E. Caden, G. F. Cao, L. Cao, C. Chambers, B. Chana, S. A. Charlebois, D. Chernyak, M. Chiu, B. Cleveland , et al. (136 additional authors not shown)

    Abstract: The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the… ▽ More

    Submitted 22 February, 2022; v1 submitted 30 June, 2021; originally announced June 2021.

    Comments: 26 pages, 19 figures, version accepted by Journal of Phys. G

    Journal ref: J. Phys. G: Nucl. Part. Phys. 49, 015104 (2022)

  10. Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon

    Authors: M. Wagenpfeil, T. Ziegler, J. Schneider, A. Fieguth, M. Murra, D. Schulte, L. Althueser, C. Huhmann, C. Weinheimer, T. Michel, G. Anton, G. Adhikari, S. Al Kharusi, E. Angelico, I. J. Arnquist, I. Badhrees, J. Bane, D. Beck, V. Belov, T. Bhatta, A. Bolotnikov, P. A. Breur, J. P. Brodsky, E. Brown, T. Brunner , et al. (118 additional authors not shown)

    Abstract: Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t… ▽ More

    Submitted 26 May, 2021; v1 submitted 16 April, 2021; originally announced April 2021.

    Comments: 18 pages, 11 figures

  11. Segmented Anodes with Sub-millimeter Spatial Resolution for MCP-Based Photodetectors

    Authors: Jinseo Park, Fangjian Wu, Evan Angelico, Henry J. Frisch, Eric Spieglan

    Abstract: Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time resolutions of 30-50 psec for single photons. Incorporating a capacitively-coupled anode allows for the use of external pickup electrodes optimized for occupancy, rate,… ▽ More

    Submitted 17 July, 2020; v1 submitted 15 July, 2020; originally announced July 2020.

  12. arXiv:2004.00580  [pdf, other

    physics.ins-det hep-ex

    Measuring the Neutrino Event Time in Liquid Argon by a Post-Reconstruction One-parameter Fit

    Authors: Evan Angelico, Andrey Elagin, Henry J. Frisch, Matthew Wetstein

    Abstract: We propose a relatively simple method to measure the event time in liquid Argon (LAr) TPC-based neutrino detectors that takes advantage of the topological reconstruction of each event from the TPC data prior to performing a one-parameter fit. Measured times and positions of detected photons are fit to the expected pattern of light from the tracks as reconstructed using the electron drift. The even… ▽ More

    Submitted 1 April, 2020; originally announced April 2020.

  13. arXiv:2003.06491  [pdf, other

    physics.ins-det hep-ex

    Air-Transfer Production Method for Large-Area Picosecond Photodetectors

    Authors: E. Angelico, A. Elagin, H. J. Frisch, E. Spieglan, B. W. Adams, M. R. Foley, M. J. Minot

    Abstract: We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside th… ▽ More

    Submitted 13 March, 2020; originally announced March 2020.

    Comments: 15 pages; 13 Figures

  14. arXiv:1909.10399  [pdf, other

    physics.ins-det nucl-ex physics.med-ph

    Performance of Large Area Picosecond Photo-Detectors (LAPPD)

    Authors: A. V. Lyashenko, B. W. Adams, M. Aviles, T. Cremer, C. D. Ertley, M. R. Foley, M. J. Minot, M. A. Popecki, M. E. Stochaj, W. A. Worstell, J. W. Elam, A. U. Mane, O. H. W. Siegmund, H. J. Frisch, A. L. Elagin, E. Angelico, E. Spieglan

    Abstract: We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single ph… ▽ More

    Submitted 23 September, 2019; originally announced September 2019.

    Comments: accepted for publication at NIMA

  15. arXiv:1904.01611  [pdf, other

    physics.acc-ph hep-ex

    Energy and Flavor Discrimination Using Precision Time Structure in On-Axis Neutrino Beams

    Authors: Evan Angelico, Jonathan Eisch, Andrey Elagin, Henry Frisch, Sergei Nagaitsev, Matthew Wetstein

    Abstract: We propose to use a higher-frequency RF bunch structure for the primary proton beam on target and precision timing to select different energy and flavor spectra from a wide-band neutrino beam, based on the relative arrival times of the neutrinos with respect to the RF bunch structure. This `stroboscopic' approach is complementary to techniques that select different neutrino energy spectra based on… ▽ More

    Submitted 2 September, 2019; v1 submitted 2 April, 2019; originally announced April 2019.

    Comments: 12 pages, 11 figures

    Journal ref: Phys. Rev. D 100, 032008 (2019)

  16. Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode

    Authors: Evan Angelico, Todd Seiss, Bernhard Adams, Andrey Elagin, Henry Frisch, Eric Spieglan

    Abstract: We have designed and tested a robust 20 $\times$ 20 cm$^2$ thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10nm-thick NiCr film deposited on a 96% pure Al$_2$O$_3$ 3mm-thick ceramic plate and connected to HV ground, provides the return path for the electron… ▽ More

    Submitted 5 October, 2016; originally announced October 2016.

    Comments: 10 pages, 7 figures