-
Ultra-sensitive radon assay using an electrostatic chamber in a recirculating system
Authors:
nEXO Collaboration,
A. Anker,
P. A. Breur,
B. Mong,
P. Acharya,
A. Amy,
E. Angelico,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
J. P. Brodsky,
S. Bron,
E. Brown,
T. Brunner,
B. Burnell,
E. Caden,
L. Q. Cao,
G. F. Cao,
D. Cesmecioglu,
D. Chernyak
, et al. (116 additional authors not shown)
Abstract:
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC)…
▽ More
Rare event searches such as neutrinoless double beta decay and Weakly Interacting Massive Particle detection require ultra-low background detectors. Radon contamination is a significant challenge for these experiments, which employ highly sensitive radon assay techniques to identify and select low-emission materials. This work presents the development of ultra-sensitive electrostatic chamber (ESC) instruments designed to measure radon emanation in a recirculating gas loop, for future lower background experiments. Unlike traditional methods that separate emanation and detection steps, this system allows continuous radon transport and detection. This is made possible with a custom-built recirculation pump. A Python-based analysis framework, PyDAn, was developed to process and fit time-dependent radon decay data. Radon emanation rates are given for various materials measured with this instrument. A radon source of known activity provides an absolute calibration, enabling statistically-limited minimal detectable activities of 20 $μ$Bq. These devices are powerful tools for screening materials in the development of low-background particle physics experiments.
△ Less
Submitted 24 April, 2025; v1 submitted 21 April, 2025;
originally announced April 2025.
-
Design of an 8-Channel 40 GS/s 20 mW/Ch Waveform Sampling ASIC in 65 nm CMOS
Authors:
Jinseo Park,
Evan Angelico,
Andrew Arzac,
Davide Braga,
Ahan Datta,
Troy England,
Camden Ertley,
Farah Fahim,
Henry J. Frisch,
Mary Heintz,
Eric Oberla,
Nathaniel J. Pastika,
Hector D. Rico-Aniles,
Paul M. Rubinov,
Xiaoran Wang,
Yui Man Richmond Yeung,
Tom N. Zimmerman
Abstract:
1 ps timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe a preliminary design for PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in the TSMC 65 nm process targetting 1 ps resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing ps…
▽ More
1 ps timing resolution is the entry point to signature based searches relying on secondary/tertiary vertices and particle identification. We describe a preliminary design for PSEC5, an 8-channel 40 GS/s waveform-sampling ASIC in the TSMC 65 nm process targetting 1 ps resolution at 20 mW power per channel. Each channel consists of four fast and one slow switched capacitor arrays (SCA), allowing ps time resolution combined with a long effective buffer. Each fast SCA is 1.6 ns long and has a nominal sampling rate of 40 GS/s. The slow SCA is 204.8 ns long and samples at 5 GS/s. Recording of the analog data for each channel is triggered by a fast discriminator capable of multiple triggering during the window of the slow SCA. To achieve a large dynamic range, low leakage, and high bandwidth, the SCA sampling switches are implemented as 2.5 V nMOSFETs controlled by 1.2 V shift registers. Stored analog data are digitized by an external ADC at 10 bits or better. Specifications on operational parameters include a 4 GHz analog bandwidth and a dead time of 20 microseconds, corresponding to a 50 kHz readout rate, determined by the choice of the external ADC.
△ Less
Submitted 17 July, 2024; v1 submitted 11 July, 2024;
originally announced July 2024.
-
Imaging of single barium atoms in a second matrix site in solid xenon for barium tagging in a $^{136}$Xe double beta decay experiment
Authors:
M. Yvaine,
D. Fairbank,
J. Soderstrom,
C. Taylor,
J. Stanley,
T. Walton,
C. Chambers,
A. Iverson,
W. Fairbank,
S. Al Kharusi,
A. Amy,
E. Angelico,
A. Anker,
I. J. Arnquist,
A. Atencio,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
J. Breslin,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (112 additional authors not shown)
Abstract:
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform s…
▽ More
Neutrinoless double beta decay is one of the most sensitive probes for new physics beyond the Standard Model of particle physics. One of the isotopes under investigation is $^{136}$Xe, which would double beta decay into $^{136}$Ba. Detecting the single $^{136}$Ba daughter provides a sort of ultimate tool in the discrimination against backgrounds. Previous work demonstrated the ability to perform single atom imaging of Ba atoms in a single-vacancy site of a solid xenon matrix. In this paper, the effort to identify signal from individual barium atoms is extended to Ba atoms in a hexa-vacancy site in the matrix and is achieved despite increased photobleaching in this site. Abrupt fluorescence turn-off of a single Ba atom is also observed. Significant recovery of fluorescence signal lost through photobleaching is demonstrated upon annealing of Ba deposits in the Xe ice. Following annealing, it is observed that Ba atoms in the hexa-vacancy site exhibit antibleaching while Ba atoms in the tetra-vacancy site exhibit bleaching. This may be evidence for a matrix site transfer upon laser excitation. Our findings offer a path of continued research toward tagging of Ba daughters in all significant sites in solid xenon.
△ Less
Submitted 28 June, 2024;
originally announced July 2024.
-
Simulation of a Compton-based detector for low-dose high-resolution time-of-flight positron emission tomography
Authors:
Kepler Domurat-Sousa,
Cameron M. Poe,
Maya S. McDaniel,
Eric Spieglan,
Joao F. Shida,
Evan Angelico,
Bernhard W. Adams,
Patrick J. La Riviere,
Henry J. Frisch,
Allison H. Squires
Abstract:
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scatte…
▽ More
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scattering locations in the detector has been proposed as a promising alternative, but the minimum technical requirements for such a system have not yet been established. Here we present a simulation study evaluating the potential of a proposed low-Z detection medium, linear alkylbenzene (LAB) doped with a switchable molecular recorder, for next-generation TOF-PET detection. We developed a custom Monte Carlo simulation of full-body TOF-PET using the TOPAS Geant4 software package. By quantifying contributions and tradeoffs for energy, spatial, and timing resolution of the detector, we show that at reasonable combination of specifications, our likelihood-based identification of pairs of first interaction locations in the simulated detector identifies 87.1% of pairs with zero or negligible error, and correctly rejects 90% of all in-patient scatters. The same specifications give TOF-PET sensitivity of ~66.7% and PSF width 4.6 mm with clear contrast. A detector with these specifications provides a clear image of a brain phantom simulated at less than 1% of a standard radiotracer dose.
△ Less
Submitted 3 January, 2024; v1 submitted 11 May, 2023;
originally announced May 2023.
-
An integrated online radioassay data storage and analytics tool for nEXO
Authors:
R. H. M. Tsang,
A. Piepke,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
A. Atencio,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Q. Cao,
D. Cesmecioglu,
C. Chambers,
E. Chambers,
B. Chana,
S. A. Charlebois
, et al. (135 additional authors not shown)
Abstract:
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassa…
▽ More
Large-scale low-background detectors are increasingly used in rare-event searches as experimental collaborations push for enhanced sensitivity. However, building such detectors, in practice, creates an abundance of radioassay data especially during the conceptual phase of an experiment when hundreds of materials are screened for radiopurity. A tool is needed to manage and make use of the radioassay screening data to quantitatively assess detector design options. We have developed a Materials Database Application for the nEXO experiment to serve this purpose. This paper describes this database, explains how it functions, and discusses how it streamlines the design of the experiment.
△ Less
Submitted 20 June, 2023; v1 submitted 12 April, 2023;
originally announced April 2023.
-
Performance of novel VUV-sensitive Silicon Photo-Multipliers for nEXO
Authors:
G. Gallina,
Y. Guan,
F. Retiere,
G. Cao,
A. Bolotnikov,
I. Kotov,
S. Rescia,
A. K. Soma,
T. Tsang,
L. Darroch,
T. Brunner,
J. Bolster,
J. R. Cohen,
T. Pinto Franco,
W. C. Gillis,
H. Peltz Smalley,
S. Thibado,
A. Pocar,
A. Bhat,
A. Jamil,
D. C. Moore,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist
, et al. (140 additional authors not shown)
Abstract:
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with…
▽ More
Liquid xenon time projection chambers are promising detectors to search for neutrinoless double beta decay (0$νββ$), due to their response uniformity, monolithic sensitive volume, scalability to large target masses, and suitability for extremely low background operations. The nEXO collaboration has designed a tonne-scale time projection chamber that aims to search for 0$νββ$ of \ce{^{136}Xe} with projected half-life sensitivity of $1.35\times 10^{28}$~yr. To reach this sensitivity, the design goal for nEXO is $\leq$1\% energy resolution at the decay $Q$-value ($2458.07\pm 0.31$~keV). Reaching this resolution requires the efficient collection of both the ionization and scintillation produced in the detector. The nEXO design employs Silicon Photo-Multipliers (SiPMs) to detect the vacuum ultra-violet, 175 nm scintillation light of liquid xenon. This paper reports on the characterization of the newest vacuum ultra-violet sensitive Fondazione Bruno Kessler VUVHD3 SiPMs specifically designed for nEXO, as well as new measurements on new test samples of previously characterised Hamamatsu VUV4 Multi Pixel Photon Counters (MPPCs). Various SiPM and MPPC parameters, such as dark noise, gain, direct crosstalk, correlated avalanches and photon detection efficiency were measured as a function of the applied over voltage and wavelength at liquid xenon temperature (163~K). The results from this study are used to provide updated estimates of the achievable energy resolution at the decay $Q$-value for the nEXO design.
△ Less
Submitted 25 November, 2022; v1 submitted 16 September, 2022;
originally announced September 2022.
-
Development of a $^{127}$Xe calibration source for nEXO
Authors:
B. G. Lenardo,
C. A. Hardy,
R. H. M. Tsang,
J. C. Nzobadila Ondze,
A. Piepke,
S. Triambak,
A. Jamil,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
V. Belov,
E. P. Bernard,
A. Bhat,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
B. Chana,
S. A. Charlebois
, et al. (103 additional authors not shown)
Abstract:
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and…
▽ More
We study a possible calibration technique for the nEXO experiment using a $^{127}$Xe electron capture source. nEXO is a next-generation search for neutrinoless double beta decay ($0νββ$) that will use a 5-tonne, monolithic liquid xenon time projection chamber (TPC). The xenon, used both as source and detection medium, will be enriched to 90% in $^{136}$Xe. To optimize the event reconstruction and energy resolution, calibrations are needed to map the position- and time-dependent detector response. The 36.3 day half-life of $^{127}$Xe and its small $Q$-value compared to that of $^{136}$Xe $0νββ$ would allow a small activity to be maintained continuously in the detector during normal operations without introducing additional backgrounds, thereby enabling in-situ calibration and monitoring of the detector response. In this work we describe a process for producing the source and preliminary experimental tests. We then use simulations to project the precision with which such a source could calibrate spatial corrections to the light and charge response of the nEXO TPC.
△ Less
Submitted 12 January, 2022;
originally announced January 2022.
-
Low-Dose High-Resolution TOF-PET Using Ionization-activated Multi-State Low-Z Detector Media
Authors:
Joao Francisco Shida,
Eric Spieglan,
Bernhard W. Adams,
Evan Angelico,
Kepler Domurat-Sousa,
Andrey Elagin,
Henry J. Frisch,
Patrick La Riviere,
Allison H. Squires
Abstract:
We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatter…
▽ More
We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a `Switchillator', that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
NEXO: Neutrinoless double beta decay search beyond $10^{28}$ year half-life sensitivity
Authors:
nEXO Collaboration,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
G. Anton,
I. J. Arnquist,
I. Badhrees,
J. Bane,
V. Belov,
E. P. Bernard,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner,
E. Caden,
G. F. Cao,
L. Cao,
C. Chambers,
B. Chana,
S. A. Charlebois,
D. Chernyak,
M. Chiu,
B. Cleveland
, et al. (136 additional authors not shown)
Abstract:
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the…
▽ More
The nEXO neutrinoless double beta decay experiment is designed to use a time projection chamber and 5000 kg of isotopically enriched liquid xenon to search for the decay in $^{136}$Xe. Progress in the detector design, paired with higher fidelity in its simulation and an advanced data analysis, based on the one used for the final results of EXO-200, produce a sensitivity prediction that exceeds the half-life of $10^{28}$ years. Specifically, improvements have been made in the understanding of production of scintillation photons and charge as well as of their transport and reconstruction in the detector. The more detailed knowledge of the detector construction has been paired with more assays for trace radioactivity in different materials. In particular, the use of custom electroformed copper is now incorporated in the design, leading to a substantial reduction in backgrounds from the intrinsic radioactivity of detector materials. Furthermore, a number of assumptions from previous sensitivity projections have gained further support from interim work validating the nEXO experiment concept. Together these improvements and updates suggest that the nEXO experiment will reach a half-life sensitivity of $1.35\times 10^{28}$ yr at 90% confidence level in 10 years of data taking, covering the parameter space associated with the inverted neutrino mass ordering, along with a significant portion of the parameter space for the normal ordering scenario, for almost all nuclear matrix elements. The effects of backgrounds deviating from the nominal values used for the projections are also illustrated, concluding that the nEXO design is robust against a number of imperfections of the model.
△ Less
Submitted 22 February, 2022; v1 submitted 30 June, 2021;
originally announced June 2021.
-
Reflectivity of VUV-sensitive Silicon Photomultipliers in Liquid Xenon
Authors:
M. Wagenpfeil,
T. Ziegler,
J. Schneider,
A. Fieguth,
M. Murra,
D. Schulte,
L. Althueser,
C. Huhmann,
C. Weinheimer,
T. Michel,
G. Anton,
G. Adhikari,
S. Al Kharusi,
E. Angelico,
I. J. Arnquist,
I. Badhrees,
J. Bane,
D. Beck,
V. Belov,
T. Bhatta,
A. Bolotnikov,
P. A. Breur,
J. P. Brodsky,
E. Brown,
T. Brunner
, et al. (118 additional authors not shown)
Abstract:
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows t…
▽ More
Silicon photomultipliers are regarded as a very promising technology for next-generation, cutting-edge detectors for low-background experiments in particle physics. This work presents systematic reflectivity studies of Silicon Photomultipliers (SiPM) and other samples in liquid xenon at vacuum ultraviolet (VUV) wavelengths. A dedicated setup at the University of Münster has been used that allows to acquire angle-resolved reflection measurements of various samples immersed in liquid xenon with 0.45° angular resolution. Four samples are investigated in this work: one Hamamatsu VUV4 SiPM, one FBK VUV-HD SiPM, one FBK wafer sample and one Large-Area Avalanche Photodiode (LA-APD) from EXO-200. The reflectivity is determined to be 25-36% at an angle of incidence of 20° for the four samples and increases to up to 65% at 70° for the LA-APD and the FBK samples. The Hamamatsu VUV4 SiPM shows a decline with increasing angle of incidence. The reflectivity results will be incorporated in upcoming light response simulations of the nEXO detector.
△ Less
Submitted 26 May, 2021; v1 submitted 16 April, 2021;
originally announced April 2021.
-
Segmented Anodes with Sub-millimeter Spatial Resolution for MCP-Based Photodetectors
Authors:
Jinseo Park,
Fangjian Wu,
Evan Angelico,
Henry J. Frisch,
Eric Spieglan
Abstract:
Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time resolutions of 30-50 psec for single photons. Incorporating a capacitively-coupled anode allows for the use of external pickup electrodes optimized for occupancy, rate,…
▽ More
Micro-channel-plate-based photo-detectors are unique in being capable of covering areas of many square-meters while providing sub-millimeter space resolution, time resolutions of less than 10 picoseconds for charged particles, time resolutions of 30-50 psec for single photons. Incorporating a capacitively-coupled anode allows for the use of external pickup electrodes optimized for occupancy, rate, and time/space resolution. The signal pickup antenna can be implemented as a printed circuit card with a pattern chosen to match the specific application needs. The electrode elements are typically either a 2-dimensional array of pads for high-occupancy/high-rate applications, or a 1-dimensional array of strips for low-occupancy/low-rate, and a lower channel count. Here we present pad patterns that enhance charge-sharing between pads to significantly lower the required channel count/area while maintaining spatial resolutions of 100 to 200 microns for charged particles and 400 microns to 1 mm for single photons. Patterns that use multiple signal layers in the capacitively-coupled printed circuit signal pickup board can lower the channel count even further, moving the scaling behavior in the number of pads versus total area from quadratic to linear.
△ Less
Submitted 17 July, 2020; v1 submitted 15 July, 2020;
originally announced July 2020.
-
Measuring the Neutrino Event Time in Liquid Argon by a Post-Reconstruction One-parameter Fit
Authors:
Evan Angelico,
Andrey Elagin,
Henry J. Frisch,
Matthew Wetstein
Abstract:
We propose a relatively simple method to measure the event time in liquid Argon (LAr) TPC-based neutrino detectors that takes advantage of the topological reconstruction of each event from the TPC data prior to performing a one-parameter fit. Measured times and positions of detected photons are fit to the expected pattern of light from the tracks as reconstructed using the electron drift. The even…
▽ More
We propose a relatively simple method to measure the event time in liquid Argon (LAr) TPC-based neutrino detectors that takes advantage of the topological reconstruction of each event from the TPC data prior to performing a one-parameter fit. Measured times and positions of detected photons are fit to the expected pattern of light from the tracks as reconstructed using the electron drift. The event can be treated as a rigid body with only the neutrino interaction time as a free parameter. The optical properties of LAr are comparable to those of water for Cherenkov light in visible wavelengths. Data-Monte Carlo comparisons of the light patterns, given the known track topology from electron drift, enable in situ calibration of the optical model and further optimization of the timing. A back-of-the-envelope calculation predicts that the single parameter fit for the interaction time requires a significantly lower photodetector coverage than needed for the same precision in conventional warm-liquid detectors.
△ Less
Submitted 1 April, 2020;
originally announced April 2020.
-
Air-Transfer Production Method for Large-Area Picosecond Photodetectors
Authors:
E. Angelico,
A. Elagin,
H. J. Frisch,
E. Spieglan,
B. W. Adams,
M. R. Foley,
M. J. Minot
Abstract:
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside th…
▽ More
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside the vacuum tube and hermetically sealing the large-perimeter window-body interface. We have also synthesized a photocathode in a large-area low-aspect-ratio volume, and shown that the micro-channel plates recover their functionality after cathode synthesis. The steps inform a design for a multi-module batch facility employing dual nested low-vacuum (LV) and ultra-high-vacuum (UHV) systems in a small-footprint. The facility design provides full access to multiple MCP-PMT modules prior to hermetic pinch-off for leak-checking and real-time photocathode optimization.
△ Less
Submitted 13 March, 2020;
originally announced March 2020.
-
Performance of Large Area Picosecond Photo-Detectors (LAPPD)
Authors:
A. V. Lyashenko,
B. W. Adams,
M. Aviles,
T. Cremer,
C. D. Ertley,
M. R. Foley,
M. J. Minot,
M. A. Popecki,
M. E. Stochaj,
W. A. Worstell,
J. W. Elam,
A. U. Mane,
O. H. W. Siegmund,
H. J. Frisch,
A. L. Elagin,
E. Angelico,
E. Spieglan
Abstract:
We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single ph…
▽ More
We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single photoelectron spatial resolution along and across strips of 3.2mm (electronics limited) and 0.8 mm RMS respectively and high (about 25\% or higher in some units) QE uniform bi-alkali photocathodes. LAPPDs is a good candidate to be employed in neutrino experiments (e.g. ANNIE, WATCHMAN, DUNE), particle collider experiments (e.g. EIC), neutrinoless double-beta decay experiments (e.g. THEIA), medical and nuclear non-proliferation applications.
△ Less
Submitted 23 September, 2019;
originally announced September 2019.
-
Energy and Flavor Discrimination Using Precision Time Structure in On-Axis Neutrino Beams
Authors:
Evan Angelico,
Jonathan Eisch,
Andrey Elagin,
Henry Frisch,
Sergei Nagaitsev,
Matthew Wetstein
Abstract:
We propose to use a higher-frequency RF bunch structure for the primary proton beam on target and precision timing to select different energy and flavor spectra from a wide-band neutrino beam, based on the relative arrival times of the neutrinos with respect to the RF bunch structure. This `stroboscopic' approach is complementary to techniques that select different neutrino energy spectra based on…
▽ More
We propose to use a higher-frequency RF bunch structure for the primary proton beam on target and precision timing to select different energy and flavor spectra from a wide-band neutrino beam, based on the relative arrival times of the neutrinos with respect to the RF bunch structure. This `stroboscopic' approach is complementary to techniques that select different neutrino energy spectra based on the angle with respect to the beam axis. A timing-based approach allows for the selection of varying energy spectra from the same on-axis detector, and applies equally to both the near and far detectors in an oscillation experiment. Energy and flavor discrimination of neutrinos produced by hadrons in-flight will require proton bunch lengths on the order of 100 ps and commensurate time resolution in the detector. Correlating neutrino events with the parent proton interaction is currently limited by the nanosecond-scale width of the proton bunches impinging on the target. We show that these limitations can be addressed by using a superconducting RF cavity to rebunch the present 53.1 MHz RF bunch structure with a factor of 10 higher RF frequency, thus attaining the required shorter bunch length.
△ Less
Submitted 2 September, 2019; v1 submitted 2 April, 2019;
originally announced April 2019.
-
Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode
Authors:
Evan Angelico,
Todd Seiss,
Bernhard Adams,
Andrey Elagin,
Henry Frisch,
Eric Spieglan
Abstract:
We have designed and tested a robust 20 $\times$ 20 cm$^2$ thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10nm-thick NiCr film deposited on a 96% pure Al$_2$O$_3$ 3mm-thick ceramic plate and connected to HV ground, provides the return path for the electron…
▽ More
We have designed and tested a robust 20 $\times$ 20 cm$^2$ thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10nm-thick NiCr film deposited on a 96% pure Al$_2$O$_3$ 3mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50$Ω$ 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20 $\times$ 20 cm$^2$ array of 2-dimensional square `pads' with sides of 1.27 cm or 2.54 cm. The rise-time of the fast input pulse is maintained for both pickup patterns. For the pad pattern, we observe 80% of the directly coupled amplitude. For the strip pattern we measure 34% of the directly coupled amplitude on the central strip of a broadened signal. The physical decoupling of the photodetector from the pickup pattern allows easy customization for different applications while maintaining high analog bandwidth.
△ Less
Submitted 5 October, 2016;
originally announced October 2016.