-
Characterization of MKIDs for CMB observation at 220 GHz with the South Pole Telescope
Authors:
Karia R. Dibert,
Peter S. Barry,
Adam J. Anderson,
Bradford A. Benson,
Thomas Cecil,
Clarence L. Chang,
Kyra N. Fichman,
Kirit Karkare,
Juliang Li,
Tyler Natoli,
Zhaodi Pan,
Maclean Rouble,
Erik Shirokoff,
Matthew Young
Abstract:
We present an updated design of the 220 GHz microwave kinetic inductance detector (MKID) pixel for SPT-3G+, the next-generation camera for the South Pole Telescope. We show results of the dark testing of a 63-pixel array with mean inductor quality factor $Q_i = 4.8 \times 10^5$, aluminum inductor transition temperature $T_c = 1.19$ K, and kinetic inductance fraction $α_k = 0.32$. We optically char…
▽ More
We present an updated design of the 220 GHz microwave kinetic inductance detector (MKID) pixel for SPT-3G+, the next-generation camera for the South Pole Telescope. We show results of the dark testing of a 63-pixel array with mean inductor quality factor $Q_i = 4.8 \times 10^5$, aluminum inductor transition temperature $T_c = 1.19$ K, and kinetic inductance fraction $α_k = 0.32$. We optically characterize both the microstrip-coupled and CPW-coupled resonators, and find both have a spectral response close to prediction with an optical efficiency of $η\sim 70\%$. However, we find slightly lower optical response on the lower edge of the band than predicted, with neighboring dark detectors showing more response in this region, though at level consistent with less than 5\% frequency shift relative to the optical detectors. The detectors show polarized response consistent with expectations, with a cross-polar response of $\sim 10\%$ for both detector orientations.
△ Less
Submitted 3 April, 2023;
originally announced April 2023.
-
Noise Optimization for MKIDs with Different Design Geometries and Material Selections
Authors:
Z. Pan,
K. R. Dibert,
J. Zhang,
P. S. Barry,
A. J. Anderson,
A. N. Bender,
B. A. Benson,
T. Cecil,
C. L. Chang,
R. Gualtieri,
J. Li,
M. Lisovenko,
V. Novosad,
M. Rouble,
G. Wang,
V. Yefremenko
Abstract:
The separation and optimization of noise components is critical to microwave-kinetic inductance detector (MKID) development. We analyze the effect of several changes to the lumped-element inductor and interdigitated capacitor geometry on the noise performance of a series of MKIDs intended for millimeter-wavelength experiments. We extract the contributions from two-level system noise in the dielect…
▽ More
The separation and optimization of noise components is critical to microwave-kinetic inductance detector (MKID) development. We analyze the effect of several changes to the lumped-element inductor and interdigitated capacitor geometry on the noise performance of a series of MKIDs intended for millimeter-wavelength experiments. We extract the contributions from two-level system noise in the dielectric layer, the generation-recombination noise intrinsic to the superconducting thin-film, and system white noise from each detector noise power spectrum and characterize how these noise components depend on detector geometry, material, and measurement conditions such as driving power and temperature. We observe a reduction in the amplitude of two-level system noise with both an elevated sample temperature and an increased gap between the fingers within the interdigitated capacitors for both aluminum and niobium detectors. We also verify the expected reduction of the generation-recombination noise and associated quasiparticle lifetime with reduced inductor volume. This study also iterates over different materials, including aluminum, niobium, and aluminum manganese, and compares the results with an underlying physical model.
△ Less
Submitted 3 April, 2023;
originally announced April 2023.
-
Fabrication Development for SPT-SLIM, a Superconducting Spectrometer for Line Intensity Mapping
Authors:
T. Cecil,
C. Albert,
A. J. Anderson,
P. S. Barry,
B. Benson,
C. Cotter,
C. Chang,
M. Dobbs,
K. Dibert,
R. Gualtieri,
K. S. Karkare,
M. Lisovenko,
D. P. Marrone,
J. Montgomery,
Z. Pan,
G. Robson,
M. Rouble,
E. Shirokoff,
G. Smecher,
G. Wang,
V. Yefremenko
Abstract:
Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format a…
▽ More
Line Intensity Mapping (LIM) is a new observational technique that uses low-resolution observations of line emission to efficiently trace the large-scale structure of the Universe out to high redshift. Common mm/sub-mm emission lines are accessible from ground-based observatories, and the requirements on the detectors for LIM at mm-wavelengths are well matched to the capabilities of large-format arrays of superconducting sensors. We describe the development of an R = 300 on-chip superconducting filter-bank spectrometer covering the 120--180 GHz band optimized for future mm-LIM experiments, focusing on SPT-SLIM, a pathfinder LIM instrument for the South Pole Telescope. Radiation is coupled from the telescope optical system to the spectrometer chip via an array of feedhorn-coupled orthomode transducers. Superconducting microstrip transmission lines then carry the signal to an array of channelizing half-wavelength resonators, and the output of each spectral channel is sensed by a lumped element kinetic inductance detector (leKID). Key areas of development include incorporating new low-loss dielectrics to improve both the achievable spectral resolution and optical efficiency and development of a robust fabrication process to create a galvanic connection between ultra-pure superconducting thin-films to realize multi-material (hybrid) leKIDs. We provide an overview of the spectrometer design, fabrication process, and prototype devices.
△ Less
Submitted 3 April, 2023;
originally announced April 2023.
-
Conceptual Design of the Modular Detector and Readout System for the CMB-S4 survey experiment
Authors:
D. R. Barron,
Z. Ahmed,
J. Aguilar,
A. J. Anderson,
C. F. Baker,
P. S. Barry,
J. A. Beall,
A. N. Bender,
B. A. Benson,
R. W. Besuner,
T. W. Cecil,
C. L. Chang,
S. C. Chapman,
G. E. Chesmore,
G. Derylo,
W. B. Doriese,
S. M. Duff,
T. Elleflot,
J. P. Filippini,
B. Flaugher,
J. G. Gomez,
P. K. Grimes,
R. Gualtieri,
I. Gullett,
G. Haller
, et al. (25 additional authors not shown)
Abstract:
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental…
▽ More
We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background Stage 4 (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60 percent of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over a wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4's science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 square meters of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
The Simulation and Design of an On-Chip Superconducting Millimetre Filter-Bank Spectrometer
Authors:
Gethin Robson,
Adam J. Anderson,
Peter S. Barry,
Simon Doyle,
Kirit S. Karkare
Abstract:
Superconducting on-chip filter-banks provide a scalable, space saving solution to create imaging spectrometers at millimetre and sub-millimetre wavelengths. We present an easy to realise, lithographed superconducting filter design with a high tolerance to fabrication error. Using a capacitively coupled $λ/2$ microstrip resonator to define a narrow ($λ/Δλ= 300$) spectral pass band, the filtered out…
▽ More
Superconducting on-chip filter-banks provide a scalable, space saving solution to create imaging spectrometers at millimetre and sub-millimetre wavelengths. We present an easy to realise, lithographed superconducting filter design with a high tolerance to fabrication error. Using a capacitively coupled $λ/2$ microstrip resonator to define a narrow ($λ/Δλ= 300$) spectral pass band, the filtered output of a given spectrometer channel directly connects to a Lumped Element Kinetic Inductance Detector (LEKID). We show the tolerance analysis of our design, demonstrating $<11\%$ change in filter quality factor to any one realistic fabrication errors and a full filter-bank efficiency forecast to be 60\% after accounting for fabrication errors and dielectric loss tangent.
△ Less
Submitted 14 June, 2022; v1 submitted 8 November, 2021;
originally announced November 2021.
-
Broadband, millimeter-wave antireflection coatings for large-format, cryogenic aluminum oxide optics
Authors:
A. Nadolski,
J. D. Vieira,
J. A. Sobrin,
A. M. Kofman,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
L. Bryant,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. R. Cheshire IV,
G. E. Chesmore,
J. F. Cliche,
A. Cukierman,
T. de Haan,
M. Dierickx,
J. Ding,
D. Dutcher,
W. Everett
, et al. (64 additional authors not shown)
Abstract:
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of com…
▽ More
We present two prescriptions for broadband (~77 - 252 GHz), millimeter-wave antireflection coatings for cryogenic, sintered polycrystalline aluminum oxide optics: one for large-format (700 mm diameter) planar and plano-convex elements, the other for densely packed arrays of quasi-optical elements, in our case 5 mm diameter half-spheres (called "lenslets"). The coatings comprise three layers of commercially-available, polytetrafluoroethylene-based, dielectric sheet material. The lenslet coating is molded to fit the 150 mm diameter arrays directly while the large-diameter lenses are coated using a tiled approach. We review the fabrication processes for both prescriptions then discuss laboratory measurements of their transmittance and reflectance. In addition, we present the inferred refractive indices and loss tangents for the coating materials and the aluminum oxide substrate. We find that at 150 GHz and 300 K the large-format coating sample achieves (97 +/- 2)% transmittance and the lenslet coating sample achieves (94 +/- 3)% transmittance.
△ Less
Submitted 2 March, 2020; v1 submitted 6 December, 2019;
originally announced December 2019.
-
Micro-X Sounding Rocket: Transitioning from First Flight to a Dark Matter Configuration
Authors:
J. S. Adams,
A. J. Anderson,
R. Baker,
S. R. Bandler,
N. Bastidon,
D. Castro,
M. E. Danowski,
W. B. Doriese,
M. E. Eckart,
E. Figueroa-Feliciano,
D. C. Goldfinger,
S. N. T. Heine,
G. C. Hilton,
A. J. F. Hubbard,
R. L. Kelley,
C. A. Kilbourne,
R. E. Manzagol-Harwood,
D. McCammon,
T. Okajima,
F. S. Porter,
C. D. Reintsema,
P. Serlemitsos,
S. J. Smith,
P. Wikus
Abstract:
The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for in…
▽ More
The Micro-X sounding rocket flew for the first time on July 22, 2018, becoming the first program to fly Transition-Edge Sensors and multiplexing SQUID readout electronics in space. While a rocket pointing failure led to no time on-target, the success of the flight systems was demonstrated. The successful flight operation of the instrument puts the program in a position to modify the payload for indirect galactic dark matter searches. The payload modifications are motivated by the science requirements of this observation. Micro-X can achieve world-leading sensitivity in the keV regime with a single flight. Dark matter sensitivity projections have been updated to include recent observations and the expected sensitivity of Micro-X to these observed fluxes. If a signal is seen (as seen in the X-ray satellites), Micro-X can differentiate an atomic line from a dark matter signature.
△ Less
Submitted 30 January, 2020; v1 submitted 22 August, 2019;
originally announced August 2019.
-
Performance of Al-Mn Transition-Edge Sensor Bolometers in SPT-3G
Authors:
A. J. Anderson,
P. A. R. Ade,
Z. Ahmed,
J. S. Avva,
P. S. Barry,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
L. Bryant,
K. Byrum,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
H. -M. Cho,
J. F. Cliche,
A. Cukierman,
T. de Haan,
E. V. Denison,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
K. R. Ferguson,
A. Foster
, et al. (64 additional authors not shown)
Abstract:
SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector wafers, containing a total of 16,000 transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of the…
▽ More
SPT-3G is a polarization-sensitive receiver, installed on the South Pole Telescope, that measures the anisotropy of the cosmic microwave background (CMB) from degree to arcminute scales. The receiver consists of ten 150~mm-diameter detector wafers, containing a total of 16,000 transition-edge sensor (TES) bolometers observing at 95, 150, and 220 GHz. During the 2018-2019 austral summer, one of these detector wafers was replaced by a new wafer fabricated with Al-Mn TESs instead of the Ti/Au design originally deployed for SPT-3G. We present the results of in-lab characterization and on-sky performance of this Al-Mn wafer, including electrical and thermal properties, optical efficiency measurements, and noise-equivalent temperature. In addition, we discuss and account for several calibration-related systematic errors that affect measurements made using frequency-domain multiplexing readout electronics.
△ Less
Submitted 27 July, 2019;
originally announced July 2019.
-
On-sky performance of the SPT-3G frequency-domain multiplexed readout
Authors:
A. N. Bender,
A. J. Anderson,
J. S. Avva,
P. A. R. Ade,
Z. Ahmed,
P. S. Barry,
R. Basu Thakur,
B. A. Benson,
L. Bryant,
K. Byrum,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
H. -M. Cho,
J. F. Cliche,
A. Cukierman,
T. de Haan,
E. V. Denison,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
K. R. Ferguson,
A. Foster
, et al. (64 additional authors not shown)
Abstract:
Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme enables the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current…
▽ More
Frequency-domain multiplexing (fMux) is an established technique for the readout of large arrays of transition edge sensor (TES) bolometers. Each TES in a multiplexing module has a unique AC voltage bias that is selected by a resonant filter. This scheme enables the operation and readout of multiple bolometers on a single pair of wires, reducing thermal loading onto sub-Kelvin stages. The current receiver on the South Pole Telescope, SPT-3G, uses a 68x fMux system to operate its large-format camera of $\sim$16,000 TES bolometers. We present here the successful implementation and performance of the SPT-3G readout as measured on-sky. Characterization of the noise reveals a median pair-differenced 1/f knee frequency of 33 mHz, indicating that low-frequency noise in the readout will not limit SPT-3G's measurements of sky power on large angular scales. Measurements also show that the median readout white noise level in each of the SPT-3G observing bands is below the expectation for photon noise, demonstrating that SPT-3G is operating in the photon-noise-dominated regime.
△ Less
Submitted 25 July, 2019;
originally announced July 2019.
-
Design and characterization of the SPT-3G receiver
Authors:
J. A. Sobrin,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. F. Cliche,
A. Cukierman,
T. de Haan,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
A. Foster,
J. Gallichio,
A. Gilbert,
J. C. Groh,
S. T. Guns,
N. W. Halverson
, et al. (46 additional authors not shown)
Abstract:
The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map anisotropies in the cosmic microwave background (CMB). New optics, detector, and readout technologies have yielded a multichroic, high-resolution, low-noise camera with impressive throughput and sensitivity, offering the potential to improve our understanding of inflationary physics, astroparticle…
▽ More
The SPT-3G receiver was commissioned in early 2017 on the 10-meter South Pole Telescope (SPT) to map anisotropies in the cosmic microwave background (CMB). New optics, detector, and readout technologies have yielded a multichroic, high-resolution, low-noise camera with impressive throughput and sensitivity, offering the potential to improve our understanding of inflationary physics, astroparticle physics, and growth of structure. We highlight several key features and design principles of the new receiver, and summarize its performance to date.
△ Less
Submitted 31 August, 2018;
originally announced September 2018.
-
Broadband anti-reflective coatings for cosmic microwave background experiments
Authors:
A. Nadolski,
A. M. Kofman,
J. D. Vieira,
P. A. R. Ade,
Z. Ahmed,
A. J. Anderson,
J. S. Avva,
R. Basu Thakur,
A. N. Bender,
B. A. Benson,
J. E. Carlstrom,
F. W. Carter,
T. W. Cecil,
C. L. Chang,
J. F. Cliche,
A. Cukierman,
T. de Haan,
J. Ding,
M. A. Dobbs,
D. Dutcher,
W. Everett,
A. Foster,
J. Fu,
J. Gallicchio,
A. Gilbert
, et al. (49 additional authors not shown)
Abstract:
The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth comp…
▽ More
The desire for higher sensitivity has driven ground-based cosmic microwave background (CMB) experiments to employ ever larger focal planes, which in turn require larger reimaging optics. Practical limits to the maximum size of these optics motivates the development of quasi-optically-coupled (lenslet-coupled), multi-chroic detectors. These detectors can be sensitive across a broader bandwidth compared to waveguide-coupled detectors. However, the increase in bandwidth comes at a cost: the lenses (up to $\sim$700 mm diameter) and lenslets ($\sim$5 mm diameter, hemispherical lenses on the focal plane) used in these systems are made from high-refractive-index materials (such as silicon or amorphous aluminum oxide) that reflect nearly a third of the incident radiation. In order to maximize the faint CMB signal that reaches the detectors, the lenses and lenslets must be coated with an anti-reflective (AR) material. The AR coating must maximize radiation transmission in scientifically interesting bands and be cryogenically stable. Such a coating was developed for the third generation camera, SPT-3G, of the South Pole Telescope (SPT) experiment, but the materials and techniques used in the development are general to AR coatings for mm-wave optics. The three-layer polytetrafluoroethylene-based AR coating is broadband, inexpensive, and can be manufactured with simple tools. The coating is field tested; AR coated focal plane elements were deployed in the 2016-2017 austral summer and AR coated reimaging optics were deployed in 2017-2018.
△ Less
Submitted 31 August, 2018;
originally announced September 2018.
-
Nuclear-recoil energy scale in CDMS II silicon dark-matter detectors
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
W. Baker,
D. Balakishiyeva,
S. Banik,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
H. Chagani,
Y. -Y. Chang,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman
, et al. (84 additional authors not shown)
Abstract:
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absol…
▽ More
The Cryogenic Dark Matter Search (CDMS II) experiment aims to detect dark matter particles that elastically scatter from nuclei in semiconductor detectors. The resulting nuclear-recoil energy depositions are detected by ionization and phonon sensors. Neutrons produce a similar spectrum of low-energy nuclear recoils in such detectors, while most other backgrounds produce electron recoils. The absolute energy scale for nuclear recoils is necessary to interpret results correctly. The energy scale can be determined in CDMS II silicon detectors using neutrons incident from a broad-spectrum $^{252}$Cf source, taking advantage of a prominent resonance in the neutron elastic scattering cross section of silicon at a recoil (neutron) energy near 20 (182) keV. Results indicate that the phonon collection efficiency for nuclear recoils is $4.8^{+0.7}_{-0.9}$% lower than for electron recoils of the same energy. Comparisons of the ionization signals for nuclear recoils to those measured previously by other groups at higher electric fields indicate that the ionization collection efficiency for CDMS II silicon detectors operated at $\sim$4 V/cm is consistent with 100% for nuclear recoils below 20 keV and gradually decreases for larger energies to $\sim$75% at 100 keV. The impact of these measurements on previously published CDMS II silicon results is small.
△ Less
Submitted 27 July, 2018; v1 submitted 7 March, 2018;
originally announced March 2018.
-
Unfolding Neutron Spectrum with Markov Chain Monte Carlo at MIT Research Reactor with He-3 Neutral Current Detectors
Authors:
A. F. Leder,
A. J. Anderson,
J. Billard,
E. Figueroa-Feliciano,
J. A. Formaggio,
C. Hasselkus,
E. Newman,
K. Palladino,
M. Phuthi,
L. Winslow,
L. Zhang
Abstract:
The Ricochet experiment seeks to measure Coherent (neutral-current) Elastic Neutrino-Nucleus Scattering using dark-matter-style detectors with sub-keV thresholds placed near a neutrino source, such as the MIT (research) Reactor (MITR), which operates at 5.5 MW generating approximately 2.2e18 neutrinos/second in its core. Currently, Ricochet is characterizing the backgrounds at MITR, the main compo…
▽ More
The Ricochet experiment seeks to measure Coherent (neutral-current) Elastic Neutrino-Nucleus Scattering using dark-matter-style detectors with sub-keV thresholds placed near a neutrino source, such as the MIT (research) Reactor (MITR), which operates at 5.5 MW generating approximately 2.2e18 neutrinos/second in its core. Currently, Ricochet is characterizing the backgrounds at MITR, the main component of which comes in the form of neutrons emitted from the core simultaneous with the neutrino signal. To characterize this background, we wrapped Bonner cylinders around a He-3 thermal neutron detector, whose data was then unfolded via a Markov Chain Monte Carlo (MCMC) to produce a neutron energy spectrum across several orders of magnitude. We discuss the resulting spectrum and its implications for deploying Ricochet at the MITR site as well as the feasibility of reducing this background level via the addition of polyethylene shielding around the detector setup.
△ Less
Submitted 7 February, 2018; v1 submitted 2 October, 2017;
originally announced October 2017.
-
Low-Mass Dark Matter Search with CDMSlite
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aralis,
T. Aramaki,
I. J. Arnquist,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
T. Binder,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeno,
Y. Chang,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell
, et al. (83 additional authors not shown)
Abstract:
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is…
▽ More
The SuperCDMS experiment is designed to directly detect weakly interacting massive particles (WIMPs) that may constitute the dark matter in our Galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}$10 GeV/$c^2$. In this mode, a higher detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector-biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 eV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the Galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses $\lesssim$3 GeV/$c^2$
△ Less
Submitted 18 January, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
Projected Sensitivity of the SuperCDMS SNOLAB experiment
Authors:
R. Agnese,
A. J. Anderson,
T. Aramaki,
I. Arnquist,
W. Baker,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
C. Cartaro,
D. G. Cerdeño,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty
, et al. (71 additional authors not shown)
Abstract:
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle…
▽ More
SuperCDMS SNOLAB will be a next-generation experiment aimed at directly detecting low-mass (< 10 GeV/c$^2$) particles that may constitute dark matter by using cryogenic detectors of two types (HV and iZIP) and two target materials (germanium and silicon). The experiment is being designed with an initial sensitivity to nuclear recoil cross sections ~ 1 x 10$^{-43}$ cm$^2$ for a dark matter particle mass of 1 GeV/c$^2$, and with capacity to continue exploration to both smaller masses and better sensitivities. The phonon sensitivity of the HV detectors will be sufficient to detect nuclear recoils from sub-GeV dark matter. A detailed calibration of the detector response to low energy recoils will be needed to optimize running conditions of the HV detectors and to interpret their data for dark matter searches. Low-activity shielding, and the depth of SNOLAB, will reduce most backgrounds, but cosmogenically produced $^{3}$H and naturally occurring $^{32}$Si will be present in the detectors at some level. Even if these backgrounds are x10 higher than expected, the science reach of the HV detectors would be over three orders of magnitude beyond current results for a dark matter mass of 1 GeV/c$^2$. The iZIP detectors are relatively insensitive to variations in detector response and backgrounds, and will provide better sensitivity for dark matter particle masses (> 5 GeV/c$^2$). The mix of detector types (HV and iZIP), and targets (germanium and silicon), planned for the experiment, as well as flexibility in how the detectors are operated, will allow us to maximize the low-mass reach, and understand the backgrounds that the experiment will encounter. Upgrades to the experiment, perhaps with a variety of ultra-low-background cryogenic detectors, will extend dark matter sensitivity down to the "neutrino floor", where coherent scatters of solar neutrinos become a limiting background.
△ Less
Submitted 30 September, 2016;
originally announced October 2016.
-
WIMP-Search Results from the Second CDMSlite Run
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
T. Aramaki,
M. Asai,
W. Baker,
D. Balakishiyeva,
D. Barker,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
R. Calkins,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
P. Cushman,
M. Daal
, et al. (65 additional authors not shown)
Abstract:
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization…
▽ More
The CDMS low ionization threshold experiment (CDMSlite) uses cryogenic germanium detectors operated at a relatively high bias voltage to amplify the phonon signal in the search for weakly interacting massive particles (WIMPs). Results are presented from the second CDMSlite run with an exposure of 70 kg days, which reached an energy threshold for electron recoils as low as 56 eV. A fiducialization cut reduces backgrounds below those previously reported by CDMSlite. New parameter space for the WIMP-nucleon spin-independent cross section is excluded for WIMP masses between 1.6 and 5.5 GeV/$c^2$.
△ Less
Submitted 9 March, 2016; v1 submitted 8 September, 2015;
originally announced September 2015.
-
Maximum Likelihood Analysis of Low Energy CDMS II Germanium Data
Authors:
SuperCDMS Collaboration,
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban
, et al. (62 additional authors not shown)
Abstract:
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background…
▽ More
We report on the results of a search for a Weakly Interacting Massive Particle (WIMP) signal in low-energy data of the Cryogenic Dark Matter Search (CDMS~II) experiment using a maximum likelihood analysis. A background model is constructed using GEANT4 to simulate the surface-event background from $^{210}$Pb decay-chain events, while using independent calibration data to model the gamma background. Fitting this background model to the data results in no statistically significant WIMP component. In addition, we perform fits using an analytic ad hoc background model proposed by Collar and Fields, who claimed to find a large excess of signal-like events in our data. We confirm the strong preference for a signal hypothesis in their analysis under these assumptions, but excesses are observed in both single- and multiple-scatter events, which implies the signal is not caused by WIMPs, but rather reflects the inadequacy of their background model.
△ Less
Submitted 3 October, 2014;
originally announced October 2014.
-
First direct limits on Lightly Ionizing Particles with electric charge less than $e/6$
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (60 additional authors not shown)
Abstract:
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six…
▽ More
While the Standard Model of particle physics does not include free particles with fractional charge, experimental searches have not ruled out their existence. We report results from the Cryogenic Dark Matter Search (CDMS II) experiment that give the first direct-detection limits for cosmogenically-produced relativistic particles with electric charge lower than $e$/6. A search for tracks in the six stacked detectors of each of two of the CDMS II towers found no candidates, thereby excluding new parameter space for particles with electric charges between $e$/6 and $e$/200.
△ Less
Submitted 3 February, 2015; v1 submitted 10 September, 2014;
originally announced September 2014.
-
Phonon-Based Position Determination in SuperCDMS iZIP Detectors
Authors:
A. J. Anderson
Abstract:
SuperCDMS is currently operating a 10-kg array of cryogenic germanium detectors in the Soudan underground laboratory to search for weakly interacting massive particles, a leading dark matter candidate. These detectors, known as iZIPs, measure ionization and athermal phonons from particle interactions with sensors on both sides of a Ge crystal. The ionization signal can be used to efficiently tag e…
▽ More
SuperCDMS is currently operating a 10-kg array of cryogenic germanium detectors in the Soudan underground laboratory to search for weakly interacting massive particles, a leading dark matter candidate. These detectors, known as iZIPs, measure ionization and athermal phonons from particle interactions with sensors on both sides of a Ge crystal. The ionization signal can be used to efficiently tag events at high radius and near the top and bottoms surfaces, where diminished charge collection can cause events to mimic WIMP-induced nuclear recoils. Using calibration data taken with a 210Pb source underground at Soudan, we demonstrate rejection of surface events of (4.5 +/- 0.9) x 10^-4 with 46% acceptance of nuclear recoils using the phonon signal only. We also show with 133Ba calibration data underground that the phonon channels can efficiently identify events near the sidewall. This phonon-based approach can also be extended to lower energies than the ionization-based position reconstruction.
△ Less
Submitted 16 May, 2014;
originally announced May 2014.
-
Constraints on Light WIMPs from SuperCDMS
Authors:
A. J. Anderson
Abstract:
The SuperCDMS experiment searches for weakly interacting massive particles (WIMPs) using cryogenic germanium detectors that measure ionization and phonon energy. Several direct searches for WIMPs have recently reported excesses of events above their background expectations, which could be interpreted as WIMPs with masses in the 8-20 GeV/c^2 range. The excellent intrinsic signal-to-noise of SuperCD…
▽ More
The SuperCDMS experiment searches for weakly interacting massive particles (WIMPs) using cryogenic germanium detectors that measure ionization and phonon energy. Several direct searches for WIMPs have recently reported excesses of events above their background expectations, which could be interpreted as WIMPs with masses in the 8-20 GeV/c^2 range. The excellent intrinsic signal-to-noise of SuperCDMS detectors and their powerful background rejection make SuperCDMS an ideal experiment to further test these signal hints. We present the results of two recent SuperCDMS analyses targeting this mass range: the first using Luke-Neganov amplification of the ionization signal to lower the effective energy threshold, and the second using multivariate methods to optimize background rejection in a larger 577 kg-d exposure.
△ Less
Submitted 16 May, 2014;
originally announced May 2014.
-
Search for Low-Mass WIMPs with SuperCDMS
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Beaty,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
Y. Chen,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
D. DeVaney
, et al. (70 additional authors not shown)
Abstract:
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is i…
▽ More
We report a first search for weakly interacting massive particles (WIMPs) using the background rejection capabilities of SuperCDMS. An exposure of 577 kg-days was analyzed for WIMPs with mass < 30 GeV/c2, with the signal region blinded. Eleven events were observed after unblinding. We set an upper limit on the spin-independent WIMP-nucleon cross section of 1.2e-42 cm2 at 8 GeV/c2. This result is in tension with WIMP interpretations of recent experiments and probes new parameter space for WIMP-nucleon scattering for WIMP masses < 6 GeV/c2.
△ Less
Submitted 12 March, 2014; v1 submitted 28 February, 2014;
originally announced February 2014.
-
CDMSlite: A Search for Low-Mass WIMPs using Voltage-Assisted Calorimetric Ionization Detection in the SuperCDMS Experiment
Authors:
R. Agnese,
A. J. Anderson,
M. Asai,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
M. A. Bowles,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
T. Doughty,
L. Esteban,
S. Fallows
, et al. (55 additional authors not shown)
Abstract:
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were coll…
▽ More
SuperCDMS is an experiment designed to directly detect Weakly Interacting Massive Particles (WIMPs), a favored candidate for dark matter ubiquitous in the Universe. In this paper, we present WIMP-search results using a calorimetric technique we call CDMSlite, which relies on voltage- assisted Luke-Neganov amplification of the ionization energy deposited by particle interactions. The data were collected with a single 0.6 kg germanium detector running for 10 live days at the Soudan Underground Laboratory. A low energy threshold of 170 eVee (electron equivalent) was obtained, which allows us to constrain new WIMP-nucleon spin-independent parameter space for WIMP masses below 6 GeV/c2.
△ Less
Submitted 20 December, 2013; v1 submitted 12 September, 2013;
originally announced September 2013.
-
Demonstration of Surface Electron Rejection with Interleaved Germanium Detectors for Dark Matter Searches
Authors:
R. Agnese,
A. J. Anderson,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
A. Borgland,
D. Brandt,
P. L. Brink,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
M. Cherry,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
P. C. F. Di Stefano,
E. Do Couto E Silva,
T. Doughty,
L. Esteban,
S. Fallows,
E. Figueroa-Feliciano
, et al. (66 additional authors not shown)
Abstract:
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were teste…
▽ More
The SuperCDMS experiment in the Soudan Underground Laboratory searches for dark matter with a 9-kg array of cryogenic germanium detectors. Symmetric sensors on opposite sides measure both charge and phonons from each particle interaction, providing excellent discrimination between electron and nuclear recoils, and between surface and interior events. Surface event rejection capabilities were tested with two $^{210}$Pb sources producing $\sim$130 beta decays/hr. In $\sim$800 live hours, no events leaked into the 8--115 keV signal region, giving upper limit leakage fraction $1.7 \times 10^{-5}$ at 90% C.L., corresponding to $< 0.6$ surface event background in the future 200-kg SuperCDMS SNOLAB experiment.
△ Less
Submitted 4 October, 2013; v1 submitted 10 May, 2013;
originally announced May 2013.
-
Silicon Detector Dark Matter Results from the Final Exposure of CDMS II
Authors:
CDMS Collaboration,
R. Agnese,
Z. Ahmed,
A. J. Anderson,
S. Arrenberg,
D. Balakishiyeva,
R. Basu Thakur,
D. A. Bauer,
J. Billard,
A. Borgland,
D. Brandt,
P. L. Brink,
T. Bruch,
R. Bunker,
B. Cabrera,
D. O. Caldwell,
D. G. Cerdeno,
H. Chagani,
J. Cooley,
B. Cornell,
C. H. Crewdson,
P. Cushman,
M. Daal,
F. Dejongh,
E. Do Couto E Silva
, et al. (66 additional authors not shown)
Abstract:
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206P…
▽ More
We report results of a search for Weakly Interacting Massive Particles (WIMPS) with the silicon detectors of the CDMS II experiment. This blind analysis of 140.2 kg-days of data taken between July 2007 and September 2008 revealed three WIMP-candidate events with a surface-event background estimate of 0.41^{+0.20}_{-0.08}(stat.)^{+0.28}_{-0.24}(syst.). Other known backgrounds from neutrons and 206Pb are limited to < 0.13 and <0.08 events at the 90% confidence level, respectively. The exposure of this analysis is equivalent to 23.4 kg-days for a recoil energy range of 7-100 keV for a WIMP of mass 10 GeV/c2. The probability that the known backgrounds would produce three or more events in the signal region is 5.4%. A profile likelihood ratio test of the three events that includes the measured recoil energies gives a 0.19% probability for the known-background-only hypothesis when tested against the alternative WIMP+background hypothesis. The highest likelihood occurs for a WIMP mass of 8.6 GeV/c2 and WIMP-nucleon cross section of 1.9e-41 cm2.
△ Less
Submitted 11 October, 2013; v1 submitted 15 April, 2013;
originally announced April 2013.
-
Measuring Active-to-Sterile Neutrino Oscillations with Neutral Current Coherent Neutrino-Nucleus Scattering
Authors:
A. J. Anderson,
J. M. Conrad,
E. Figueroa-Feliciano,
C. Ignarra,
G. Karagiorgi,
K. Scholberg,
M. H. Shaevitz,
J. Spitz
Abstract:
Light sterile neutrinos have been introduced as an explanation for a number of oscillation signals at $Δm^2 \sim 1$ eV$^2$. Neutrino oscillations at relatively short baselines provide a probe of these possible new states. This paper describes an accelerator-based experiment using neutral current coherent neutrino-nucleus scattering to strictly search for active-to-sterile neutrino oscillations. Th…
▽ More
Light sterile neutrinos have been introduced as an explanation for a number of oscillation signals at $Δm^2 \sim 1$ eV$^2$. Neutrino oscillations at relatively short baselines provide a probe of these possible new states. This paper describes an accelerator-based experiment using neutral current coherent neutrino-nucleus scattering to strictly search for active-to-sterile neutrino oscillations. This experiment could, thus, definitively establish the existence of sterile neutrinos and provide constraints on their mixing parameters. A cyclotron-based proton beam can be directed to multiple targets, producing a low energy pion and muon decay-at-rest neutrino source with variable distance to a single detector. Two types of detectors are considered: a germanium-based detector inspired by the CDMS design and a liquid argon detector inspired by the proposed CLEAR experiment.
△ Less
Submitted 18 January, 2012;
originally announced January 2012.
-
Modeling phase-separated transition-edge sensors in SuperCDMS detectors
Authors:
A. J. Anderson,
S. W. Leman,
T. Doughty,
E. Figueroa-Feliciano,
K. A. McCarthy,
M. Pyle,
B. A. Young
Abstract:
The SuperCDMS experiment implements transition-edge sensors to measure athermal phonons produced by nuclear recoils in Ge crystals. We discuss a numerical simulation of these TES devices and a procedure for tuning the free model parameters to data, which reproduces superconducting-to-normal phase separation within a TES. This tuning provides insight into the behavior of the TESs, allows us to stud…
▽ More
The SuperCDMS experiment implements transition-edge sensors to measure athermal phonons produced by nuclear recoils in Ge crystals. We discuss a numerical simulation of these TES devices and a procedure for tuning the free model parameters to data, which reproduces superconducting-to-normal phase separation within a TES. This tuning provides insight into the behavior of the TESs, allows us to study the phase-separation length to optimize our detector design, and is integrated into a more complete simulation of the phonon and charge physics of SuperCDMS detectors.
△ Less
Submitted 23 September, 2011; v1 submitted 16 September, 2011;
originally announced September 2011.
-
Simulations of Noise in Phase-Separated Transition-Edge Sensors for SuperCDMS
Authors:
A. J. Anderson,
S. W. Leman,
M. Pyle,
E. Figueroa-Feliciano,
K. McCarthy,
T. Doughty,
M. Cherry,
B. Young
Abstract:
We briefly review a simple model of superconducting-normal phase-separation in transition-edge sensors in the SuperCDMS experiment. After discussing some design considerations relevant to the TES in the detectors, we study noise sources in both the phase-separated and phase-uniform cases. Such simulations are valuable for optimizing the critical temperature and TES length of future SuperCDMS detec…
▽ More
We briefly review a simple model of superconducting-normal phase-separation in transition-edge sensors in the SuperCDMS experiment. After discussing some design considerations relevant to the TES in the detectors, we study noise sources in both the phase-separated and phase-uniform cases. Such simulations are valuable for optimizing the critical temperature and TES length of future SuperCDMS detectors.
△ Less
Submitted 6 September, 2011;
originally announced September 2011.
-
The Measurement of the Hubble Constant H_0 in the Solar System
Authors:
Allen Joel Anderson
Abstract:
This paper discusses the methodology necessary to measure the Hubble constant Ho to a high degree of accuracy based upon Doppler tracking of spacecraft in the solar system. Using this methodology with available published data we determine a model independent value of the Hubble constant for the current epoch in the solar system to be Ho = 2.59 \pm 0.05 x 10^-18 (s^-1) or as 79.8 \pm 1.7 (km/s/Mpc)…
▽ More
This paper discusses the methodology necessary to measure the Hubble constant Ho to a high degree of accuracy based upon Doppler tracking of spacecraft in the solar system. Using this methodology with available published data we determine a model independent value of the Hubble constant for the current epoch in the solar system to be Ho = 2.59 \pm 0.05 x 10^-18 (s^-1) or as 79.8 \pm 1.7 (km/s/Mpc).
We calculate the direct effect of the Cosmic Redshift on Doppler tracking of spacecraft in the solar system. It is shown that with current tracking systems, such as NASA's Deep Space Tracking Network, when the return trip light time of the Doppler signal exceeds a certain threshold, imposed by the stability of the frequency standard, the effect of the Cosmic Redshift is coherently conserved in the returning Doppler signal.
We demonstrate that in an underdetermined orbit, one determined by line of sight Doppler alone, that if this Cosmic Redshift term is not accounted for, the orbit determination program (ODP) miscalculates the actual recessional velocity of the spacecraft from the measured recessional velocity causing a mismatch between the actual and the predicted trajectory of the spacecraft. One consequence is that the ODP will generate Doppler residuals, the difference between the actual trajectory and the predicted trajectory which show an anomalous force. When this effect is integrated in long arc solutions, it can grow to considerable magnitude. We show that the ODP residuals uniquely separate the Cosmic Redshift term from velocity Doppler sources and that the solution can provide an accurate determination of Ho.
△ Less
Submitted 8 November, 2010;
originally announced November 2010.