Skip to main content

Showing 1–12 of 12 results for author: Alme, J

Searching in archive physics. Search in all archives.
.
  1. arXiv:2503.02788  [pdf, other

    physics.comp-ph physics.ins-det

    Reconstruction of proton relative stopping power with a granular calorimeter detector model

    Authors: M. Aehle, J. Alme, G. G. Barnaföldi, G. Bíró, T. Bodova, V. Borshchov, A. van den Brink, M. Chaar, B. Dudás, V. Eikeland, G. Feofilov, C. Garth, N. R. Gauger, O. Grøttvik, H. Helstrup, S. Igolkin, Zs. Jólesz, R. Keidel, C. Kobdaj, T. Kortus, L. Kusch, V. Leonhardt, S. Mehendale, R. Ningappa, O. H. Odland , et al. (27 additional authors not shown)

    Abstract: Proton computed tomography (pCT) aims to facilitate precise dose planning for hadron therapy, a promising and effective method for cancer treatment. Hadron therapy utilizes protons and heavy ions to deliver well focused doses of radiation, leveraging the Bragg peak phenomenon to target tumors while sparing healthy tissues. The Bergen pCT Collaboration aims to develop a novel pCT scanner, and accom… ▽ More

    Submitted 4 March, 2025; originally announced March 2025.

    Comments: 14 pages, 6 figures, 1 table

  2. Performance of the electromagnetic and hadronic prototype segments of the ALICE Forward Calorimeter

    Authors: M. Aehle, J. Alme, C. Arata, I. Arsene, I. Bearden, T. Bodova, V. Borshchov, O. Bourrion, M. Bregant, A. van den Brink, V. Buchakchiev, A. Buhl, T. Chujo, L. Dufke, V. Eikeland, M. Fasel, N. Gauger, A. Gautam, A. Ghimouz, Y. Goto, R. Guernane, T. Hachiya, H. Hassan, L. He, H. Helstrup , et al. (52 additional authors not shown)

    Abstract: We present the performance of a full-length prototype of the ALICE Forward Calorimeter (FoCal). The detector is composed of a silicon-tungsten electromagnetic sampling calorimeter with longitudinal and transverse segmentation (FoCal-E) of about 20$X_0$ and a hadronic copper-scintillating-fiber calorimeter (FoCal-H) of about 5$λ_{\rm int}$. The data were taken between 2021 and 2023 at the CERN PS a… ▽ More

    Submitted 16 July, 2024; v1 submitted 13 November, 2023; originally announced November 2023.

    Comments: 57 pages (without acronyms), 45 captioned figures

    Journal ref: JINST 19 P07006 (2024)

  3. arXiv:2209.02511  [pdf, other

    physics.ins-det hep-ex

    Performance of the Electromagnetic Pixel Calorimeter Prototype EPICAL-2

    Authors: J. Alme, R. Barthel, A. van Bochove, V. Borshchov, R. Bosley, A. van den Brink, E. Broeils, H. Büsching, V. N. Eikeland, O. S. Groettvik, Y. H. Han, N. van der Kolk, J. H. Kim, T. J. Kim, Y. Kwon, M. Mager, Q. W. Malik, E. Okkinga, T. Y. Park, T. Peitzmann, F. Pliquett, M. Protsenko, F. Reidt, S. van Rijk, K. Røed , et al. (9 additional authors not shown)

    Abstract: The first evaluation of an ultra-high granularity digital electromagnetic calorimeter prototype using 1.0-5.8 GeV/c electrons is presented. The $25\times10^6$ pixel detector consists of 24 layers of ALPIDE CMOS MAPS sensors, with a pitch of around 30~$μ$m, and has a depth of almost 20 radiation lengths of tungsten absorber. Ultra-thin cables allow for a very compact design. The properties that are… ▽ More

    Submitted 28 December, 2022; v1 submitted 6 September, 2022; originally announced September 2022.

    Comments: 30 pages, 19 figures, submitted to JINST

  4. arXiv:2207.01815  [pdf, other

    physics.ins-det hep-ex

    Results from the EPICAL-2 Ultra-High Granularity Electromagnetic Calorimeter Prototype

    Authors: T. Peitzmann, J. Alme, R. Barthel, A. van Bochove, V. Borshchov, R. Bosley, A. van den Brink, E. Broeils, H. Büsching, V. N. Eikeland, O. S. Groettvik, Y. H. Han, N. van der Kolk, J. H. Kim, T. J. Kim, Y. Kwon, M. Mager, Q. W. Malik, E. Okkinga, T. Y. Park, F. Pliquett, M. Protsenko, F. Reidt, S. van Rijk, K. Røed , et al. (9 additional authors not shown)

    Abstract: A prototype of a new type of calorimeter has been designed and constructed, based on a silicon-tungsten sampling design using pixel sensors with digital readout. It makes use of the Alpide MAPS sensor developed for the ALICE ITS upgrade. A binary readout is possible due to the pixel size of $\approx 30 \times 30 \, μ\mathrm{m}^2$. This prototype has been successfully tested with cosmic muons and w… ▽ More

    Submitted 27 September, 2022; v1 submitted 5 July, 2022; originally announced July 2022.

    Comments: Proceedings to PM2021 - The 15. PISA Meeting on Advanced Detectors, updated after referee review

  5. arXiv:2202.05551  [pdf, other

    physics.med-ph cs.MS

    Exploration of Differentiability in a Proton Computed Tomography Simulation Framework

    Authors: Max Aehle, Johan Alme, Gergely Gábor Barnaföldi, Johannes Blühdorn, Tea Bodova, Vyacheslav Borshchov, Anthony van den Brink, Viljar Eikeland, Gregory Feofilov, Christoph Garth, Nicolas R. Gauger, Ola Grøttvik, Håvard Helstrup, Sergey Igolkin, Ralf Keidel, Chinorat Kobdaj, Tobias Kortus, Lisa Kusch, Viktor Leonhardt, Shruti Mehendale, Raju Ningappa Mulawade, Odd Harald Odland, George O'Neill, Gábor Papp, Thomas Peitzmann , et al. (25 additional authors not shown)

    Abstract: Objective. Algorithmic differentiation (AD) can be a useful technique to numerically optimize design and algorithmic parameters by, and quantify uncertainties in, computer simulations. However, the effectiveness of AD depends on how "well-linearizable" the software is. In this study, we assess how promising derivative information of a typical proton computed tomography (pCT) scan computer simulati… ▽ More

    Submitted 12 May, 2023; v1 submitted 11 February, 2022; originally announced February 2022.

    Comments: 27 pages, 11 figures

  6. The charge sensitivity calibration of the upgraded ALICE Inner Tracking System

    Authors: Shiming Yuan, Johan Alme, Markus Keil, Ivan Ravasenga, Matthias Richter, Dieter Röhrich

    Abstract: The ALICE detector is undergoing an upgrade for Run 3 at the LHC. A new Inner Tracking System (ITS) is part of this upgrade. The upgraded ALICE ITS features the ALPIDE, a Monolithic Active Pixel Sensor. Due to IC fabrication variations and radiation damages, the threshold values for the ALPIDE chips in ITS need to be measured and adjusted periodically to ensure the quality of data. The calibration… ▽ More

    Submitted 24 October, 2021; originally announced October 2021.

  7. arXiv:2105.13000  [pdf, other

    physics.ins-det

    First demonstration of in-beam performance of bent Monolithic Active Pixel Sensors

    Authors: ALICE ITS project, :, G. Aglieri Rinella, M. Agnello, B. Alessandro, F. Agnese, R. S. Akram, J. Alme, E. Anderssen, D. Andreou, F. Antinori, N. Apadula, P. Atkinson, R. Baccomi, A. Badalà, A. Balbino, C. Bartels, R. Barthel, F. Baruffaldi, I. Belikov, S. Beole, P. Becht, A. Bhatti, M. Bhopal, N. Bianchi , et al. (230 additional authors not shown)

    Abstract: A novel approach for designing the next generation of vertex detectors foresees to employ wafer-scale sensors that can be bent to truly cylindrical geometries after thinning them to thicknesses of 20-40$μ$m. To solidify this concept, the feasibility of operating bent MAPS was demonstrated using 1.5$\times$3cm ALPIDE chips. Already with their thickness of 50$μ$m, they can be successfully bent to ra… ▽ More

    Submitted 17 August, 2021; v1 submitted 27 May, 2021; originally announced May 2021.

  8. The upgrade of the ALICE TPC with GEMs and continuous readout

    Authors: J. Adolfsson, M. Ahmed, S. Aiola, J. Alme, T. Alt, W. Amend, F. Anastasopoulos, C. Andrei, M. Angelsmark, V. Anguelov, A. Anjam, H. Appelshäuser, V. Aprodu, O. Arnold, M. Arslandok, D. Baitinger, M. Ball, G. G. Barnaföldi, E. Bartsch, P. Becht, R. Bellwied, A. Berdnikova, M. Berger, N. Bialas, P. Bialas , et al. (210 additional authors not shown)

    Abstract: The upgrade of the ALICE TPC will allow the experiment to cope with the high interaction rates foreseen for the forthcoming Run 3 and Run 4 at the CERN LHC. In this article, we describe the design of new readout chambers and front-end electronics, which are driven by the goals of the experiment. Gas Electron Multiplier (GEM) detectors arranged in stacks containing four GEMs each, and continuous re… ▽ More

    Submitted 25 March, 2021; v1 submitted 17 December, 2020; originally announced December 2020.

    Comments: 88 pages, 60 figures

    Journal ref: JINST 16 (2021) P03022

  9. arXiv:2011.03815  [pdf, other

    physics.ins-det eess.SY hep-ex

    Remote Configuration of the ProASIC3 on the ALICE Inner Tracking System Readout Unit

    Authors: Shiming Yuan, Johan Alme, Dieter Röhrich, Matthias Richter, Magnus Rentsch Ersdal, Piero Giubilato, Gianluca Aglieri Rinella, Arild Velure, Matteo Lupi, Johann Joachim Schambach

    Abstract: A Large Ion Collider Experiment (ALICE) is one of the four major experiments conducted at the CERN Large Hadron Collider (LHC). The ALICE detector is currently undergoing an upgrade for the upcoming Run 3 at the LHC. The new Inner Tracking System (ITS) sub-detector is part of this upgrade. The front-end electronics of the ITS is composed by 192 Readout Units, installed in a radiation environment.… ▽ More

    Submitted 7 November, 2020; originally announced November 2020.

  10. Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade

    Authors: M. M. Aggarwal, Z. Ahammed, S. Aiola, J. Alme, T. Alt, W. Amend, A. Andronic, V. Anguelov, H. Appelshäuser, M. Arslandok, R. Averbeck, M. Ball, G. G. Barnaföldi, E. Bartsch, R. Bellwied, G. Bencedi, M. Berger, N. Bialas, P. Bialas, L. Bianchi, S. Biswas, L. Boldizsár, L. Bratrud, P. Braun-Munzinger, M. Bregant , et al. (155 additional authors not shown)

    Abstract: A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivit… ▽ More

    Submitted 17 June, 2018; v1 submitted 8 May, 2018; originally announced May 2018.

    Comments: Submitted to NIM A

    Journal ref: Nucl. Instrum. Meth. A903 (2018), 215-223

  11. arXiv:1611.02031  [pdf

    physics.med-ph physics.ins-det

    Proton tracking in a high-granularity Digital Tracking Calorimeter for proton CT purposes

    Authors: Helge Egil Seime Pettersen, Johan Alme, Aleksandra Biegun, Anthony van den Brink, Mamdouh Chaar, Dominik Fehlker, Ilker Meric, Odd Harald Odland, Thomas Peitzmann, Elena Rocco, Hongkai Wang, Shiming Yang, Chunhui Zhang, Dieter Röhrich

    Abstract: Radiation therapy with protons as of today utilizes information from x-ray CT in order to estimate the proton stopping power of the traversed tissue in a patient. The conversion from x-ray attenuation to proton stopping power in tissue introduces range uncertainties of the order of 2-3% of the range, uncertainties that are contributing to an increase of the necessary planning margins added to the… ▽ More

    Submitted 14 June, 2017; v1 submitted 7 November, 2016; originally announced November 2016.

    Comments: 21 pages, 8 figures

    Journal ref: Nucl. Instr. Meth. Phys. Res. A 860 (2017) 51-61

  12. The ALICE TPC, a large 3-dimensional tracking device with fast readout for ultra-high multiplicity events

    Authors: J. Alme, Y. Andres, H. Appelshauser, S. Bablok, N. Bialas, R. Bolgen, U. Bonnes, R. Bramm, P. Braun-Munzinger, R. Campagnolo, P. Christiansen, A. Dobrin, C. Engster, D. Fehlker, P. Foka, U. Frankenfeld, J. J. Gaardhoje, C. Garabatos, P. Glassel, C. Gonzalez Gutierrez, P. Gros, H. -A. Gustafsson, H. Helstrup, M. Hoch, M. Ivanov , et al. (51 additional authors not shown)

    Abstract: The design, construction, and commissioning of the ALICE Time-Projection Chamber (TPC) is described. It is the main device for pattern recognition, tracking, and identification of charged particles in the ALICE experiment at the CERN LHC. The TPC is cylindrical in shape with a volume close to 90 m^3 and is operated in a 0.5 T solenoidal magnetic field parallel to its axis. In this paper we des… ▽ More

    Submitted 12 January, 2010; originally announced January 2010.

    Comments: 55 pages, 82 figures

    Journal ref: Nucl.Instrum.Meth.A622:316-367,2010