-
Instrumented mouthguards in elite sports: Validity and head acceleration event (HAE) incidence in NCAA American Football
Authors:
Mario Rotundo,
Nicholas Murray,
David Allan,
Gregory Tierney
Abstract:
Objectives: To determine the on-field validity of instrumented mouthguards (iMGs) in American football and to quantify head acceleration event (HAE) incidence in NCAA football players. Methods: Instrumented mouthguards were fitted to 35 male NCAA football players. Head kinematic data were collected during 64 player matches. On-field validity was determined through video review with positive predic…
▽ More
Objectives: To determine the on-field validity of instrumented mouthguards (iMGs) in American football and to quantify head acceleration event (HAE) incidence in NCAA football players. Methods: Instrumented mouthguards were fitted to 35 male NCAA football players. Head kinematic data were collected during 64 player matches. On-field validity was determined through video review with positive predictive value (PPV) and sensitivity values calculated. HAE incidence was calculated as the number of HAEs per player match and stratified by Offense and Defense positions. Results: On-field validity of the Prevent Biometrics iMG in NCAA American Football indicates a sensitivity was 0.89 and PPV ranging from 0.76-0.98 based on false positive definitions. The incidence of PLA and PAA HAEs above a range of thresholds in Defense and Offense appear similar. The incidence of HAEs above 10 g was 11.2 and 11.3 HAEs per player match for Defense and Offense, respectively, while PAA incidence above 1.0 krad/s2 was 5.5 and 6.9 HAEs per player match for Defense and Offense, respectively. Incidence of HAEs above 30 g was 1.6 and 2.6 per player match and 0.9 and 1.4 for HAEs above 2.0 krad/s2 for Defense and Offense, respectively. Conclusion: The Prevent Biometrics iMG appears suitable for measuring HAEs in elite American football. The study provides a benchmark assessment of HAE incidence in elite American Football and lays a foundation for the development of position-specific interventions aimed at reducing HAE exposure.
△ Less
Submitted 20 February, 2025;
originally announced February 2025.
-
Quantum Imaging with X-rays
Authors:
Justin C. Goodrich,
Ryan Mahon,
Joseph Hanrahan,
Dennis Bollweg,
Monika Dziubelski,
Raphael A. Abrahao,
Sanjit Karmakar,
Kazimierz J. Gofron,
Thomas A. Caswell,
Daniel Allan,
Lonny Berman,
Andrei Nomerotski,
Andrei Fluerasu,
Cinzia DaVia,
Sean McSweeney
Abstract:
Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quant…
▽ More
Quantum imaging encompasses a broad range of methods that exploit the quantum properties of light to capture information about an object. One such approach involves using a two-photon quantum state, where only one photon interacts with the object being imaged while its entangled partner carries spatial or temporal information. To implement this technique, it is necessary to generate specific quantum states of light and detect photons at the single-photon level. While this method has been successfully demonstrated in the visible electromagnetic spectrum, extending it to X-rays has faced significant challenges due to the difficulties in producing a sufficient rate of X-ray photon pairs and detecting them with adequate resolution. Here, we demonstrate record high rates of correlated X-ray photon pairs produced via a spontaneous parametric down-conversion process and we employ these photons to perform quantum correlation imaging of several objects, including a biological sample (E. cardamomum seedpod). Notably, we report an unprecedented detection rate of about 6,300 pairs per hour and the observation of energy anti-correlation for the X-ray photon pairs. We also present a detailed analysis of the properties of the down-converted X-ray photons, as well as a comprehensive study of the correlation imaging formation, including a study of distortions and corrections. These results mark a substantial advancement in X-ray quantum imaging, expanding the possibilities of X-ray quantum optical technologies, and illustrating the pathway towards enhancing biological imaging with reduced radiation doses.
△ Less
Submitted 12 December, 2024;
originally announced December 2024.
-
Identifying a severity measure for head acceleration events associated with suspected concussions
Authors:
Gregory Tierney,
Ross Tucker,
James Tooby,
Lindsay Starling,
Eanna Falvey,
Danielle Salmon,
James Brown,
Sam Hudson,
Keith Stokes,
Ben Jones,
Simon Kemp,
Patrick OHalloran,
Matt Cross,
Melanie Bussey,
David Allan
Abstract:
Objectives: To identify a head acceleration event (HAE) severity measure associated with HIA1 removals in elite level rugby union.
Methods: HAEs were recorded from 215 men and 325 women with 30 and 28 HIA1 removals from men and women, respectively. Logistical regression were calculated to identify if peak power, maximum principal strain (MPS) and or Head Acceleration Response Metric (HARM) were…
▽ More
Objectives: To identify a head acceleration event (HAE) severity measure associated with HIA1 removals in elite level rugby union.
Methods: HAEs were recorded from 215 men and 325 women with 30 and 28 HIA1 removals from men and women, respectively. Logistical regression were calculated to identify if peak power, maximum principal strain (MPS) and or Head Acceleration Response Metric (HARM) were associated with HIA1 events compared to non-cases. Optimal threshold values were determined using the Youden Index. Area under the curve (AUC) were compared using a paired sample approach. Significant differences were set at p<0.05.
Results: All three severity measures were associated with HIA1 removals in both the mens and womens game. Power performed greatest for HIA1 removals in both the mens and womens games, based on overall AUC, sensitivity, and specificity values. HARM and MPS were found to perform lower than PLA in the womens game based on AUC comparisons (p=0.006 and 0.001, respectively), with MPS performing lower than PAA (p=0.001).
Conclusion: The findings progress our understanding of HAE measures associated with HIA1 removals. Peak power, a measure based on fundamental mechanics and commonly used in sports performance, may be a suitable HAE severity measure.
△ Less
Submitted 2 October, 2024;
originally announced October 2024.
-
Imaging of X-ray Pairs in a Spontaneous Parametric Down-Conversion Process
Authors:
Justin C. Goodrich,
Ryan Mahon,
Joseph Hanrahan,
Monika Dziubelski,
Raphael A. Abrahao,
Sanjit Karmakar,
Kazimierz J. Gofron,
Thomas Caswell,
Daniel Allan,
Lonny Berman,
Andrei Fluerasu,
Andrei Nomerotski,
Cinzia DaVià,
Sean McSweeney
Abstract:
Spontaneous parametric down-conversion is a vital method for generating correlated photon pairs in the visible and near-infrared spectral regions; however, its extension to X-ray frequencies has faced substantial barriers. Here, we present an advancement in correlated X-ray pair generation and detection by employing a two-dimensional pixelated detector to obtain the first direct image of the pair…
▽ More
Spontaneous parametric down-conversion is a vital method for generating correlated photon pairs in the visible and near-infrared spectral regions; however, its extension to X-ray frequencies has faced substantial barriers. Here, we present an advancement in correlated X-ray pair generation and detection by employing a two-dimensional pixelated detector to obtain the first direct image of the pair distribution. Our study explores and directly visualizes the down-conversion process, revealing the characteristic ring structure of coincident photon pairs and demonstrating robust spatial correlations. A significant finding is the observation of energy anti-correlation, achieved at an unprecedented rate of approximately 4,100 pairs/hour, far exceeding previous reports in the literature. We believe these results represent a significant leap in X-ray quantum imaging, unlocking the potential for enhanced imaging of biological materials with reduced doses and broadening the applicability of X-ray quantum optical technologies.
△ Less
Submitted 19 October, 2023;
originally announced October 2023.
-
The Electromagnetic Calorimeter for the T2K Near Detector ND280
Authors:
D. Allan,
C. Andreopoulos,
C. Angelsen,
G. J. Barker,
G. Barr,
S. Bentham,
I. Bertram,
S. Boyd,
K. Briggs,
R. G. Calland,
J. Carroll,
S. L. Cartwright,
A. Carver,
C. Chavez,
G. Christodoulou,
J. Coleman,
P. Cooke,
G. Davies,
C. Densham,
F. Di Lodovico,
J. Dobson,
T. Duboyski,
T. Durkin,
D. L. Evans,
A. Finch
, et al. (84 additional authors not shown)
Abstract:
The T2K experiment studies oscillations of an off-axis muon neutrino beam between the J-PARC accelerator complex and the Super-Kamiokande detector. Special emphasis is placed on measuring the mixing angle theta_13 by observing electron neutrino appearance via the sub-dominant muon neutrino to electron neutrino oscillation, and searching for CP violation in the lepton sector. The experiment include…
▽ More
The T2K experiment studies oscillations of an off-axis muon neutrino beam between the J-PARC accelerator complex and the Super-Kamiokande detector. Special emphasis is placed on measuring the mixing angle theta_13 by observing electron neutrino appearance via the sub-dominant muon neutrino to electron neutrino oscillation, and searching for CP violation in the lepton sector. The experiment includes a sophisticated, off-axis, near detector, the ND280, situated 280 m downstream of the neutrino production target in order to measure the properties of the neutrino beam and to understand better neutrino interactions at the energy scale below a few GeV. The data collected with the ND280 are used to study charged- and neutral-current neutrino interaction rates and kinematics prior to oscillation, in order to reduce uncertainties in the oscillation measurements by the far detector. A key element of the near detector is the ND280 electromagnetic calorimeter (ECal), consisting of active scintillator bars sandwiched between lead sheets and read outwith multi-pixel photon counters (MPPCs). The ECal is vital to the reconstruction of neutral particles, and the identification of charged particle species. The ECal surrounds the Pi-0 detector (P0D) and the tracking region of the ND280, and is enclosed in the former UA1/NOMAD dipole magnet. This paper describes the design, construction and assembly of the ECal, as well as the materials from which it is composed. The electronic and data acquisition (DAQ) systems are discussed, and performance of the ECal modules, as deduced from measurements with particle beams, cosmic rays, the calibration system, and T2K data, is described.
△ Less
Submitted 18 September, 2013; v1 submitted 15 August, 2013;
originally announced August 2013.
-
"Winter is coming"
Authors:
Veselin Kostov,
Daniel Allan,
Nikolaus Hartman,
Scott Guzewich,
Justin Rogers
Abstract:
Those that do not sow care little about such mundane things as equinoxes or planting seasons, or even crop rotation for that matter. Wherever and whenever the reavers reave, the mood is always foul and the nights are never warm or pleasant. For the rest of the good folks of Westeros, however, a decent grasp of the long-term weather forecast is a necessity. Many a maester have tried to play the Gam…
▽ More
Those that do not sow care little about such mundane things as equinoxes or planting seasons, or even crop rotation for that matter. Wherever and whenever the reavers reave, the mood is always foul and the nights are never warm or pleasant. For the rest of the good folks of Westeros, however, a decent grasp of the long-term weather forecast is a necessity. Many a maester have tried to play the Game of Weather Patterns and foretell when to plant those last turnip seeds, hoping for a few more years of balmy respite. Tried and failed. For other than the somewhat vague (if not outright meaningless) omens of "Winter is Coming", their meteorological efforts have been worse than useless. To right that appalling wrong, here we attempt to explain the apparently erratic seasonal changes in the world of G.R.R.M. A natural explanation for such phenomena is the unique behavior of a circumbinary planet. Thus, by speculating that the planet under scrutiny is orbiting a pair of stars, we utilize the power of numerical three-body dynamics to predict that, unfortunately, it is not possible to predict either the length, or the severity of any coming winter. We conclude that, alas, the Maesters were right -- one can only throw their hands in the air in frustration and, defeated by non-analytic solutions, mumble "Coming winter? May be long and nasty (~850 days, T<268K) or may be short and sweet (~600 days, T~273K). Who knows..."
△ Less
Submitted 1 April, 2013;
originally announced April 2013.
-
The T2K Experiment
Authors:
T2K Collaboration,
K. Abe,
N. Abgrall,
H. Aihara,
Y. Ajima,
J. B. Albert,
D. Allan,
P. -A. Amaudruz,
C. Andreopoulos,
B. Andrieu,
M. D. Anerella,
C. Angelsen,
S. Aoki,
O. Araoka,
J. Argyriades,
A. Ariga,
T. Ariga,
S. Assylbekov,
J. P. A. M. de André,
D. Autiero,
A. Badertscher,
O. Ballester,
M. Barbi,
G. J. Barker,
P. Baron
, et al. (499 additional authors not shown)
Abstract:
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross…
▽ More
The T2K experiment is a long-baseline neutrino oscillation experiment. Its main goal is to measure the last unknown lepton sector mixing angle θ_{13} by observing ν_e appearance in a ν_μ beam. It also aims to make a precision measurement of the known oscillation parameters, Δm^{2}_{23} and sin^{2} 2θ_{23}, via ν_μ disappearance studies. Other goals of the experiment include various neutrino cross section measurements and sterile neutrino searches. The experiment uses an intense proton beam generated by the J-PARC accelerator in Tokai, Japan, and is composed of a neutrino beamline, a near detector complex (ND280), and a far detector (Super-Kamiokande) located 295 km away from J-PARC. This paper provides a comprehensive review of the instrumentation aspect of the T2K experiment and a summary of the vital information for each subsystem.
△ Less
Submitted 8 June, 2011; v1 submitted 6 June, 2011;
originally announced June 2011.