-
Impact of perfusion ROI detection to the quality of CBV perfusion map
Authors:
Svitlana Alkhimova
Abstract:
The object of research in this study is quality of CBV perfusion map, considering detection of perfusion ROI as a key component in processing of dynamic susceptibility contrast magnetic resonance images of a human head. CBV map is generally accepted to be the best among others to evaluate location and size of stroke lesions and angiogenesis of brain tumors. Its poor accuracy can cause failed resul…
▽ More
The object of research in this study is quality of CBV perfusion map, considering detection of perfusion ROI as a key component in processing of dynamic susceptibility contrast magnetic resonance images of a human head. CBV map is generally accepted to be the best among others to evaluate location and size of stroke lesions and angiogenesis of brain tumors. Its poor accuracy can cause failed results for both quantitative measurements and visual assessment of cerebral blood volume. The impact of perfusion ROI detection on the quality of maps was analyzed through comparison of maps produced from threshold and reference images of the same datasets from 12 patients with cerebrovascular disease. Brain perfusion ROI was placed to exclude low intensity (air and non-brain tissues regions) and high intensity (cerebrospinal fluid regions) pixels. Maps were produced using area under the curve and deconvolution methods. For both methods compared maps were primarily correlational according to Pearson correlation analysis: r=0.8752 and r=0.8706 for area under the curve and deconvolution, respectively, p<2.2*10^-16. In spite of this, for both methods scatter plots had data points associated with missed blood regions and regression lines indicated presence of scale and offset errors for maps produced from threshold images. Obtained results indicate that thresholding is an ineffective way to detect brain perfusion ROI, which usage can cause degradation of CBV map quality. Perfusion ROI detection should be standardized and accepted into validation protocols of new systems for perfusion data analysis.
△ Less
Submitted 20 November, 2019;
originally announced December 2019.
-
Analysis of effectiveness of thresholding in perfusion ROI detection on T2-weighted MR images with abnormal brain anatomy
Authors:
Svitlana Alkhimova,
Svitlana Sliusar
Abstract:
The brain perfusion ROI detection being a preliminary step, designed to exclude non-brain tissues from analyzed DSC perfusion MR images. Its accuracy is considered as the key factor for delivering correct results of perfusion data analysis. Despite the large variety of algorithms developed on brain tissues segmentation, there is no one that works reliably and robustly on 2T-waited MR images of a h…
▽ More
The brain perfusion ROI detection being a preliminary step, designed to exclude non-brain tissues from analyzed DSC perfusion MR images. Its accuracy is considered as the key factor for delivering correct results of perfusion data analysis. Despite the large variety of algorithms developed on brain tissues segmentation, there is no one that works reliably and robustly on 2T-waited MR images of a human head with abnormal brain anatomy. Therefore, thresholding method is still the state-of-the-art technique that is widely used as a way of managing pixels involved in brain perfusion ROI. This paper presents the analysis of effectiveness of thresholding techniques in brain perfusion ROI detection on 2T-waited MR images of a human head with abnormal brain anatomy. Four threshold-based algorithms implementation are considered: according to Otsu method as global thresholding, according to Niblack method as local thresholding, thresholding in approximate anatomical brain location, and brute force thresholding. The analysis is done using comparison of qualitative maps produced from thresholded images and from the reference ones. Pearson correlation analysis showed strong positive (r was ranged from 0.7123 to 0.8518, p<0.01) and weak positive (r<0.35, p<0.01) relationship in case of conducted experiments with CBF, CBV, MTT and Tmax maps, respectively. Linear regression analysis showed at level of 95% confidence interval that maps produced from thresholded images were subject to scale and offset errors in all conducted experiments. The experimental results showed that widely used thresholding methods are an ineffective way of managing pixels involved in brain perfusion ROI. Thresholding as brain segmentation tool can lead to poor placement of perfusion ROI and, as a result, produced maps will be subject to artifacts and can cause falsely high or falsely low perfusion parameters assessment.
△ Less
Submitted 5 December, 2019;
originally announced December 2019.
-
Detection of perfusion ROI as a quality control in perfusion analysis
Authors:
Svitlana Alkhimova
Abstract:
In perfusion analysis automated approaches for image processing is preferable due to reduce time-consuming tasks for radiologists. Assessment of perfusion results quality is important step in development of algorithms for automated processing. One of them is an assessment of perfusion maps quality based on detection of perfusion ROI.
In perfusion analysis automated approaches for image processing is preferable due to reduce time-consuming tasks for radiologists. Assessment of perfusion results quality is important step in development of algorithms for automated processing. One of them is an assessment of perfusion maps quality based on detection of perfusion ROI.
△ Less
Submitted 4 February, 2019;
originally announced February 2019.