Skip to main content

Showing 1–23 of 23 results for author: Alfonso, K

Searching in archive physics. Search in all archives.
.
  1. arXiv:2505.23955  [pdf, other

    hep-ex physics.ins-det

    Exploring the keV-scale physics potential of CUORE

    Authors: CUORE Collaboration, D. Q. Adams, C. Alduino, K. Alfonso, A. Armatol, F. T. Avignone III, O. Azzolini, G. Bari, F. Bellini, G. Benato, M. Beretta, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, A. Caminata, A. Campani, J. Cao, C. Capelli, S. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali , et al. (98 additional authors not shown)

    Abstract: We present the analysis techniques developed to explore the keV-scale energy region of the CUORE experiment, based on more than 2 tonne yr of data collected over 5 years. By prioritizing a stricter selection over a larger exposure, we are able to optimize data selection for thresholds at 10 keV and 3 keV with 691 kg yr and 11 kg yr of data, respectively. We study how the performance varies among t… ▽ More

    Submitted 29 May, 2025; originally announced May 2025.

  2. arXiv:2505.09652  [pdf, other

    physics.ins-det nucl-ex

    First-ever detection of microseismic activity with a tonne-scale cryogenic experiment

    Authors: D. Q. Adams, C. Alduino, K. Alfonso, A. Armatol, F. T. Avignone, O. Azzolini, G. Bari, F. Bellini, G. Benato, M. Beretta, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, A. Caminata, A. Campani, J. Cao, C. Capelli, S. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali, E. Celi , et al. (105 additional authors not shown)

    Abstract: Vibrations from experimental setups and the environment are a persistent source of noise for low-temperature calorimeters searching for rare events, including neutrinoless double beta ($0νββ$) decay or dark matter interactions. Such noise can significantly limit experimental sensitivity to the physics case under investigation. Here we report the first detection of marine microseismic vibrations us… ▽ More

    Submitted 13 May, 2025; originally announced May 2025.

  3. arXiv:2503.04481  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Innovating Bolometers' Mounting: A Gravity-Based Approach

    Authors: The CUPID Collaboration, K. Alfonso, A. Armatol, C. Augier, F. T. Avignone III, O. Azzolini, A. S. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, L. Benussi, V. Berest, M. Beretta, M. Bettelli, M. Biassoni, J. Billard, F. Boffelli, V. Boldrini, E. D. Brandani, C. Brofferio, C. Bucci, M. Buchynska, J. Camilleri , et al. (168 additional authors not shown)

    Abstract: Cryogenic calorimeters, also known as bolometers, are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of $^{100}$Mo. The CUPID collaboration proposed an innovative approach to assembling bolometers in a stacked configuration, held in position solely by grav… ▽ More

    Submitted 6 March, 2025; originally announced March 2025.

  4. arXiv:2503.02894  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex

    CUPID, the CUORE Upgrade with Particle IDentification

    Authors: The CUPID Collaboration, K. Alfonso, A. Armatol, C. Augier, F. T. Avignone III, O. Azzolini, A. S. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, L. Benussi, V. Berest, M. Beretta, L. Bergé, M. Bettelli, M. Biassoni, J. Billard, F. Boffelli, V. Boldrini, E. D. Brandani, C. Brofferio, C. Bucci, M. Buchynska , et al. (168 additional authors not shown)

    Abstract: CUPID, the CUORE Upgrade with Particle IDentification, is a next-generation experiment to search for neutrinoless double beta decay ($0νββ$) and other rare events using enriched Li$_2$$^{100}$MoO$_4$ scintillating bolometers. It will be hosted by the CUORE cryostat located at the Laboratori Nazionali del Gran Sasso in Italy. The main physics goal of CUPID is to search for $0νββ$\ of $^{100}$Mo wit… ▽ More

    Submitted 11 July, 2025; v1 submitted 1 March, 2025; originally announced March 2025.

    Comments: Accepted for publication by EPJC; 25 pages, 6 figures, and 2 tables

    Journal ref: Eur. Phys. J. C 85, 737 (2025)

  5. arXiv:2406.12380  [pdf, other

    hep-ex physics.ins-det

    Search for fractionally charged particles with CUORE

    Authors: CUORE Collaboration, D. Q. Adams, C. Alduino, K. Alfonso, F. T. Avignone III, O. Azzolini, G. Bari, F. Bellini, G. Benato, M. Beretta, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, A. Caminata, A. Campani, J. Cao, S. Capelli, C. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali, E. Celi , et al. (95 additional authors not shown)

    Abstract: The Cryogenic Underground Observatory for Rare Events (CUORE) is a detector array comprised by 988 5$\;$cm$\times$5$\;$cm$\times$5$\;$cm TeO$_2$ crystals held below 20 mK, primarily searching for neutrinoless double-beta decay in $^{130}$Te. Unprecedented in size amongst cryogenic calorimetric experiments, CUORE provides a promising setting for the study of exotic through-going particles. Using th… ▽ More

    Submitted 18 June, 2024; originally announced June 2024.

    Comments: 7 pages, 5 figures

  6. arXiv:2405.17937  [pdf, other

    nucl-ex astro-ph.IM physics.ins-det

    Data-driven background model for the CUORE experiment

    Authors: CUORE Collaboration, D. Q. Adams, C. Alduino, K. Alfonso, F. T. Avignone III, O. Azzolini, G. Bari, F. Bellini, G. Benato, M. Beretta, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, A. Caminata, A. Campani, J. Cao, S. Capelli, C. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali, E. Celi , et al. (93 additional authors not shown)

    Abstract: We present the model we developed to reconstruct the CUORE radioactive background based on the analysis of an experimental exposure of 1038.4 kg yr. The data reconstruction relies on a simultaneous Bayesian fit applied to energy spectra over a broad energy range. The high granularity of the CUORE detector, together with the large exposure and extended stable operations, allow for an in-depth explo… ▽ More

    Submitted 28 May, 2024; originally announced May 2024.

  7. arXiv:2304.04674  [pdf, other

    physics.ins-det nucl-ex

    A first test of CUPID prototypal light detectors with NTD-Ge sensors in a pulse-tube cryostat

    Authors: CUPID collaboration, K. Alfonso, A. Armatol, C. Augier, F. T. Avignone III, O. Azzolini, M. Balata, A. S. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, V. Berest, M. Beretta, M. Bettelli, M. Biassoni, J. Billard, V. Boldrini, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, A. Campani, C. Capelli , et al. (154 additional authors not shown)

    Abstract: CUPID is a next-generation bolometric experiment aiming at searching for neutrinoless double-beta decay with ~250 kg of isotopic mass of $^{100}$Mo. It will operate at $\sim$10 mK in a cryostat currently hosting a similar-scale bolometric array for the CUORE experiment at the Gran Sasso National Laboratory (Italy). CUPID will be based on large-volume scintillating bolometers consisting of… ▽ More

    Submitted 10 April, 2023; originally announced April 2023.

    Comments: Prepared for submission to JINST; 16 pages, 7 figures, and 1 table

  8. arXiv:2304.04611  [pdf, other

    physics.ins-det nucl-ex

    Twelve-crystal prototype of Li$_2$MoO$_4$ scintillating bolometers for CUPID and CROSS experiments

    Authors: CUPID, CROSS collaborations, :, K. Alfonso, A. Armatol, C. Augier, F. T. Avignone III, O. Azzolini, M. Balata, I. C. Bandac, A. S. Barabash, G. Bari, A. Barresi, D. Baudin, F. Bellini, G. Benato, V. Berest, M. Beretta, M. Bettelli, M. Biassoni, J. Billard, V. Boldrini, A. Branca, C. Brofferio, C. Bucci , et al. (160 additional authors not shown)

    Abstract: An array of twelve 0.28 kg lithium molybdate (LMO) low-temperature bolometers equipped with 16 bolometric Ge light detectors, aiming at optimization of detector structure for CROSS and CUPID double-beta decay experiments, was constructed and tested in a low-background pulse-tube-based cryostat at the Canfranc underground laboratory in Spain. Performance of the scintillating bolometers was studied… ▽ More

    Submitted 10 April, 2023; originally announced April 2023.

    Comments: Prepared for submission to JINST; 23 pages, 9 figures, and 4 tables

  9. arXiv:2205.04549  [pdf, other

    physics.ins-det nucl-ex

    An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter

    Authors: CUORE Collaboration, D. Q. Adams, C. Alduino, K. Alfonso, F. T. Avignone III, O. Azzolini, G. Bari, F. Bellini, G. Benato, M. Beretta, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, A. Caminata, A. Campani, L. Canonica, X. G. Cao, S. Capelli, C. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali , et al. (96 additional authors not shown)

    Abstract: The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear therm… ▽ More

    Submitted 28 July, 2022; v1 submitted 9 May, 2022; originally announced May 2022.

    Comments: 34 pages, 14 figures, 6 tables

  10. arXiv:2108.07883  [pdf, other

    physics.ins-det nucl-ex

    CUORE Opens the Door to Tonne-scale Cryogenics Experiments

    Authors: CUORE Collaboration, D. Q. Adams, C. Alduino, F. Alessandria, K. Alfonso, E. Andreotti, F. T. Avignone III, O. Azzolini, M. Balata, I. Bandac, T. I. Banks, G. Bari, M. Barucci, J. W. Beeman, F. Bellini, G. Benato, M. Beretta, A. Bersani, D. Biare, M. Biassoni, F. Bragazzi, A. Branca, C. Brofferio, A. Bryant, A. Buccheri , et al. (184 additional authors not shown)

    Abstract: The past few decades have seen major developments in the design and operation of cryogenic particle detectors. This technology offers an extremely good energy resolution - comparable to semiconductor detectors - and a wide choice of target materials, making low temperature calorimetric detectors ideal for a variety of particle physics applications. Rare event searches have continued to require eve… ▽ More

    Submitted 2 December, 2021; v1 submitted 17 August, 2021; originally announced August 2021.

    Comments: 45 pages, 14 figures

    Journal ref: Prog. Part. Nucl. Phys., 122 (2021), Article 103902

  11. arXiv:2011.09295  [pdf, other

    physics.ins-det nucl-ex

    New results from the CUORE experiment

    Authors: A. Giachero, D. Q. Adams, C. Alduino, K. Alfonso, F. T. Avignone III, O. Azzolini, G. Bari, F. Bellini, G. Benato, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, J. Camilleri, A. Caminata, A. Campani, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali, E. Celi, D. Chiesa , et al. (88 additional authors not shown)

    Abstract: The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion… ▽ More

    Submitted 7 January, 2021; v1 submitted 18 November, 2020; originally announced November 2020.

    Comments: Proceeding of 40th International Conference on High Energy physics (ICHEP2020), July 28 - August 6, 2020, Prague, Czech Republic (virtual meeting). arXiv admin note: text overlap with arXiv:1905.07667

  12. An automated system to define the optimal operating settings of cryogenic calorimeters

    Authors: Krystal Alfonso, Carlo Bucci, Lucia Canonica, Paolo Carniti, Sergio Di Domizio, Andrea Giachero, Claudio Gotti, Laura Marini, Irene Nutini, Gianluigi Pessina

    Abstract: Cryogenic macro-calorimeters instrumented with NTD thermistors have been developed for several decades. The choice of the optimal bias current is crucial for a proper operation of these detectors, both in terms of energy resolution and stability. In this paper we present a set of automatic measurements and analysis procedures for the characterization and optimization of the working configuration o… ▽ More

    Submitted 8 June, 2021; v1 submitted 14 July, 2020; originally announced July 2020.

    Journal ref: Nuclear Instruments and Methods in Physics Research - Section A, Volume 1008, 21 August 2021, 165451

  13. arXiv:1811.10363  [pdf, other

    nucl-ex physics.ins-det

    Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0

    Authors: CUORE Collaboration, C. Alduino, K. Alfonso, D. R. Artusa, F. T. Avignone III, O. Azzolini, T. I. Banks, G. Bari, J. W. Beeman, F. Bellini, A. Bersani, M. Biassoni, C. Brofferio, C. Bucci, A. Caminata, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Carbone, L. Cardani, P. Carniti, N. Casali, L. Cassina, D. Chiesa , et al. (96 additional authors not shown)

    Abstract: We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the ha… ▽ More

    Submitted 29 November, 2018; v1 submitted 26 November, 2018; originally announced November 2018.

    Comments: 9 pages, 5 figures, 5 tables

    Journal ref: Eur. Phys. J. C 79, 795 (2019)

  14. arXiv:1808.10342  [pdf, other

    nucl-ex hep-ex physics.ins-det

    Update on the recent progress of the CUORE experiment

    Authors: CUORE Collaboration, D. Q. Adams, C. Alduino, K. Alfonso, F. T. Avignone III, O. Azzolini, G. Bari, F. Bellini, G. Benato, A. Bersani, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, A. Caminata, A. Campani, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali, L. Cassina, D. Chiesa , et al. (96 additional authors not shown)

    Abstract: CUORE is a 741 kg array of 988 TeO$_2$ bolometeric crystals designed to search for the neutrinoless double beta decay of $^{130}$Te and other rare processes. CUORE has been taking data since summer 2017, and as of summer 2018 collected a total of 86.3 kg$\cdot$yr of TeO$_2$ exposure. Based on this exposure, we were able to set a limit on the $0νββ$ half-life of $^{130}$Te of… ▽ More

    Submitted 30 August, 2018; originally announced August 2018.

    Comments: Proceedings of the Neutrino 2018 Conference. 8 pages, 7 figures

  15. arXiv:1801.05403  [pdf, other

    nucl-ex physics.ins-det

    Study of Rare Nuclear Processes with CUORE

    Authors: CUORE Collaboration, C. Alduino, K. Alfonso, F. T. Avignone III, O. Azzolini, G. Bari, F. Bellini, G. Benato, A. Bersani, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, A. Caminata, A. Campani, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali, L. Cassina, D. Chiesa, N. Chott , et al. (94 additional authors not shown)

    Abstract: TeO2 bolometers have been used for many years to search for neutrinoless double beta decay in 130-Te. CUORE, a tonne-scale TeO2 detector array, recently published the most sensitive limit on the half-life, $T_{1/2}^{0ν} > 1.5 \times 10^{25}\,$yr, which corresponds to an upper bound of $140-400$~meV on the effective Majorana mass of the neutrino. While it makes CUORE a world-leading experiment look… ▽ More

    Submitted 17 January, 2018; v1 submitted 16 January, 2018; originally announced January 2018.

    Comments: 36 pages, 13 figures, sumbitted to IJMPA Special Issue "Results and Developments in the investigation of rare nuclear decays and processes"

  16. arXiv:1710.07988  [pdf, other

    nucl-ex hep-ex physics.ins-det

    First Results from CUORE: A Search for Lepton Number Violation via $0νββ$ Decay of $^{130}$Te

    Authors: CUORE Collaboration, C. Alduino, K. Alfonso, E. Andreotti, C. Arnaboldi, F. T. Avignone III, O. Azzolini, I. Bandac, T. I. Banks, G. Bari, M. Barucci, J. W. Beeman, F. Bellini, G. Benato, A. Bersani, D. Biare, M. Biassoni, A. Branca, C. Brofferio, A. Bryant, A. Buccheri, C. Bucci, C. Bulfon, A. Camacho, A. Caminata , et al. (140 additional authors not shown)

    Abstract: The CUORE experiment, a ton-scale cryogenic bolometer array, recently began operation at the Laboratori Nazionali del Gran Sasso in Italy. The array represents a significant advancement in this technology, and in this work we apply it for the first time to a high-sensitivity search for a lepton-number--violating process: $^{130}$Te neutrinoless double-beta decay. Examining a total TeO$_2$ exposure… ▽ More

    Submitted 1 April, 2018; v1 submitted 22 October, 2017; originally announced October 2017.

    Comments: Published in PRL, reference and DOI added

    Journal ref: Phys. Rev. Lett. 120, 132501 (2018)

  17. arXiv:1708.07809  [pdf, other

    physics.ins-det nucl-ex

    Low Energy Analysis Techniques for CUORE

    Authors: CUORE Collaboration, C. Alduino, K. Alfonso, D. R. Artusa, F. T. Avignone III, O. Azzolini, G. Bari, J. W. Beeman, F. Bellini, G. Benato, A. Bersani, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, A. Camacho, A. Caminata, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Cardani, P. Carniti, N. Casali, L. Cassina , et al. (99 additional authors not shown)

    Abstract: CUORE is a tonne-scale cryogenic detector operating at the Laboratori Nazionali del Gran Sasso (LNGS) that uses tellurium dioxide bolometers to search for neutrinoless double-beta decay of $^{130}$Te. CUORE is also suitable to search for low energy rare events such as solar axions or WIMP scattering, thanks to its ultra-low background and large target mass. However, to conduct such sensitive searc… ▽ More

    Submitted 14 December, 2017; v1 submitted 25 August, 2017; originally announced August 2017.

    Comments: 11 pages, 6 figures

    Journal ref: Eur. Phys. J. C (2017) 77: 857

  18. arXiv:1705.10816  [pdf, other

    physics.ins-det nucl-ex

    CUORE Sensitivity to $0νββ$ Decay

    Authors: CUORE Collaboration, C. Alduino, K. Alfonso, D. R. Artusa, F. T. Avignone III, O. Azzolini, T. I. Banks, G. Bari, J. W. Beeman, F. Bellini, G. Benato, A. Bersani, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, A. Camacho, A. Caminata, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Carbone, L. Cardani, P. Carniti , et al. (106 additional authors not shown)

    Abstract: We report a study of the CUORE sensitivity to neutrinoless double beta ($0νββ$) decay. We used a Bayesian analysis based on a toy Monte Carlo (MC) approach to extract the exclusion sensitivity to the $0νββ$ decay half-life ($T_{1/2}^{0ν}$) at $90\%$ credibility interval (CI) -- i.e. the interval containing the true value of $T_{1/2}^{0ν}$ with $90\%$ probability -- and the $3 σ$ discovery sensitiv… ▽ More

    Submitted 14 August, 2017; v1 submitted 30 May, 2017; originally announced May 2017.

    Comments: 10 pages, 3 figures, 4 tables

    Journal ref: Eur. Phys. J. C (2017) 77:532

  19. The projected background for the CUORE experiment

    Authors: CUORE Collaboration, C. Alduino, K. Alfonso, D. R. Artusa, F. T. Avignone III, O. Azzolini, T. I. Banks, G. Bari, J. W. Beeman, F. Bellini, G. Benato, A. Bersani, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, A. Camacho, A. Caminata, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Carbone, L. Cardani, P. Carniti , et al. (107 additional authors not shown)

    Abstract: The Cryogenic Underground Observatory for Rare Events (CUORE) is designed to search for neutrinoless double beta decay of 130Te with an array of 988 TeO2 bolometers operating at temperatures around 10 mK. The experiment is currently being commissioned in Hall A of Laboratori Nazionali del Gran Sasso, Italy. The goal of CUORE is to reach a 90\% C.L. exclusion sensitivity on the \tect decay half-lif… ▽ More

    Submitted 31 August, 2017; v1 submitted 28 April, 2017; originally announced April 2017.

    Comments: 17 pages, 7 figures, matches published version

    Journal ref: Eur. Phys. J. C (2017) 77:543

  20. The CUORE and CUORE-0 experiments at LNGS

    Authors: A. D'Addabbo, C. Alduino, K. Alfonso, D. R. Artusa, F. T. Avignone III, O. Azzolini, T. I. Banks, G. Bari, J. W. Beeman, F. Bellini, A. Bersani, M. Biassoni, A. Branca, C. Brofferio, C. Bucci, A. Camacho, A. Caminata, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Carbone, L. Cardani, P. Carniti, N. Casali , et al. (100 additional authors not shown)

    Abstract: The Cryogenic Underground Observatory for Rare Events (CUORE) is a 1-ton scale bolometric experiment devoted to the search of the neutrinoless double-beta decay (0ν\b{eta}\b{eta}) in 130Te. The CUORE detector consists of an array of 988 TeO2 crystals operated at 10 mK. CUORE-0 is the CUORE demonstrator: it has been built to test the performance of the upcoming CUORE experiment and represents the l… ▽ More

    Submitted 13 December, 2016; originally announced December 2016.

    Comments: 10 pages, 7 figures, ICNFP2016 Proceeding

  21. arXiv:1604.05465  [pdf

    physics.ins-det nucl-ex

    CUORE-0 detector: design, construction and operation

    Authors: CUORE Collaboration, C. Alduino, K. Alfonso, D. R. Artusa, F. T. Avignone III, O. Azzolini, M. Balata, T. I. Banks, G. Bari, J. W. Beeman, F. Bellini, A. Bersani, D. Biare, M. Biassoni, F. Bragazzi, C. Brofferio, A. Buccheri, C. Bucci, C. Bulfon, A. Caminata, L. Canonica, X. G. Cao, S. Capelli, M. Capodiferro, L. Cappelli , et al. (129 additional authors not shown)

    Abstract: The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the C… ▽ More

    Submitted 18 July, 2016; v1 submitted 19 April, 2016; originally announced April 2016.

    Comments: 39 pages, 26 figures

    ACM Class: J.2

    Journal ref: JINST 11 P07009 (2016)

  22. arXiv:1601.01334  [pdf, other

    nucl-ex hep-ex physics.ins-det

    Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in $^{130}$Te with CUORE-0

    Authors: CUORE Collaboration, C. Alduino, K. Alfonso, D. R. Artusa, F. T. Avignone III, O. Azzolini, T. I. Banks, G. Bari, J. W. Beeman, F. Bellini, A. Bersani, M. Biassoni, C. Brofferio, C. Bucci, A. Caminata, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Carbone, L. Cardani, P. Carniti, N. Casali, L. Cassina, D. Chiesa , et al. (96 additional authors not shown)

    Abstract: We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques develo… ▽ More

    Submitted 27 April, 2016; v1 submitted 6 January, 2016; originally announced January 2016.

    Comments: 18 pages, 18 figures. (Version 3 reflects only minor changes to the text. Few additional details, no major content changes.)

    Journal ref: Phys. Rev. C 93, 045503 (2016)

  23. arXiv:1504.02454  [pdf, other

    nucl-ex hep-ex physics.ins-det

    Search for Neutrinoless Double-Beta Decay of $^{130}$Te with CUORE-0

    Authors: K. Alfonso, D. R. Artusa, F. T. Avignone III, O. Azzolini, M. Balata, T. I. Banks, G. Bari, J. W. Beeman, F. Bellini, A. Bersani, M. Biassoni, C. Brofferio, C. Bucci, A. Caminata, L. Canonica, X. G. Cao, S. Capelli, L. Cappelli, L. Carbone, L. Cardani, N. Casali, L. Cassina, D. Chiesa, N. Chott, M. Clemenza , et al. (93 additional authors not shown)

    Abstract: We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The me… ▽ More

    Submitted 1 October, 2015; v1 submitted 9 April, 2015; originally announced April 2015.

    Comments: 6 pages, 5 figures, updated version as published in PRL

    Journal ref: Phys. Rev. Lett. 115, 102502 (2015)