-
A multiscale Bayesian approach to quantification and denoising of energy-dispersive x-ray data
Authors:
Pau Torruella,
Abderrahim Halimi,
Ludovica Tovaglieri,
Céline Lichtensteiger,
Duncan T. L. Alexander,
Cécile Hébert
Abstract:
Energy dispersive X-ray (EDX) spectrum imaging yields compositional information with a spatial resolution down to the atomic level. However, experimental limitations often produce extremely sparse and noisy EDX spectra. Under such conditions, every detected X-ray must be leveraged to obtain the maximum possible amount of information about the sample. To this end, we introduce a robust multiscale B…
▽ More
Energy dispersive X-ray (EDX) spectrum imaging yields compositional information with a spatial resolution down to the atomic level. However, experimental limitations often produce extremely sparse and noisy EDX spectra. Under such conditions, every detected X-ray must be leveraged to obtain the maximum possible amount of information about the sample. To this end, we introduce a robust multiscale Bayesian approach that accounts for the Poisson statistics in the EDX data and leverages their underlying spatial correlations. This is combined with EDX spectral simulation (elemental contributions and Bremsstrahlung background) into a Bayesian estimation strategy. When tested using simulated datasets, the chemical maps obtained with this approach are more accurate and preserve a higher spatial resolution than those obtained by standard methods. These properties translate to experimental datasets, where the method enhances the atomic resolution chemical maps of a canonical tetragonal ferroelectric PbTiO3 sample, such that ferroelectric domains are mapped with unit-cell resolution.
△ Less
Submitted 11 February, 2025;
originally announced February 2025.
-
Decoding Gray Matter: large-scale analysis of brain cell morphometry to inform microstructural modeling of diffusion MR signals
Authors:
Charlie Aird-Rossiter,
Hui Zhang,
Daniel C. Alexander,
Derek K. Jones,
Marco Palombo
Abstract:
The structure of grey matter has long been a key focus in neuroscience, as cell morphology varies by type and can be affected by neurological conditions. Understanding these variations is essential for studying brain function and disease. Diffusion-weighted MRI (dMRI) is a powerful non-invasive tool for examining cellular microstructure in vivo. However, for dMRI to accurately reflect cellular fea…
▽ More
The structure of grey matter has long been a key focus in neuroscience, as cell morphology varies by type and can be affected by neurological conditions. Understanding these variations is essential for studying brain function and disease. Diffusion-weighted MRI (dMRI) is a powerful non-invasive tool for examining cellular microstructure in vivo. However, for dMRI to accurately reflect cellular features, it is crucial to determine which aspects of morphology influence its measurements. Proper interpretation of dMRI data depends on understanding its sensitivity to different cellular characteristics.
Despite growing interest in cellular morphology, there has been no systematic report on the key features defining different neural cell types. To address this, we analyzed over 3,500 three-dimensional cellular reconstructions across three species and nine cell types, establishing reference values for critical morphological traits. These traits fall into three categories: structural features that define the cell's skeletal framework, shape features that describe spatial organization, and topological features that break down cellular structure to distinguish cell types. Beyond reporting these reference values, we examine their relevance for dMRI, identifying which neural features dMRI can detect and which cell types may be distinguishable.
This work provides essential benchmarks for grey matter research, offering new guidelines on linking neuroimaging measurements to neurobiology. These reference values will be a valuable resource for neuroscientists and neuroimaging researchers, aiding in the interpretation of imaging data and the refinement of brain tissue models.
△ Less
Submitted 10 February, 2025; v1 submitted 3 January, 2025;
originally announced January 2025.
-
Tailoring the Spectral and Directional Emissivity of Functionalized Laser Processed Surfaces
Authors:
Andrew Butler,
Andrew Reicks,
Dennis Alexander,
George Gogos,
Craig A. Zuhlke,
Christos Argyropoulos
Abstract:
Development of methods to control the directional and spectral characteristics of thermal radiation from metallic surfaces is a critical factor enabling many important thermal management applications. In this paper, we study the thermal emission properties of functionalized aluminum surfaces produced through femtosecond laser surface processing (FLSP). These types of surfaces have recently been fo…
▽ More
Development of methods to control the directional and spectral characteristics of thermal radiation from metallic surfaces is a critical factor enabling many important thermal management applications. In this paper, we study the thermal emission properties of functionalized aluminum surfaces produced through femtosecond laser surface processing (FLSP). These types of surfaces have recently been found to exhibit near-unity broadband omnidirectional emissivity. However, their ultrabroadband absorption response includes visible and near-infrared (IR) radiation, in addition to the mid-IR range, which limits their use as daytime passive radiative cooling devices. Here, we present ways to solve this problem by demonstrating a new design that uses a dielectric Bragg visible light reflector to accurately control the thermal emission spectra of the FLSP surface with the goal of achieving high performance daytime radiative cooling operation. In addition, we propose other designs based on dielectric multilayer structures to further tailor and control the spectra and thermal emission angles of the FLSP surfaces leading to narrowband and broadband directional thermal radiation. The presented photonic engineering approach combined with FLSP structures will be beneficial to various emerging applications, such as radiative cooling, thermal sensing, and thermophotovoltaics.
△ Less
Submitted 19 August, 2024;
originally announced August 2024.
-
Leveraging Machine Learning for Advanced Nanoscale X-ray Analysis: Unmixing Multicomponent Signals and Enhancing Chemical Quantification
Authors:
Hui Chen,
Duncan T. L. Alexander,
Cécile Hébert
Abstract:
Energy dispersive X-ray (EDX) spectroscopy in the transmission electron microscope is a key tool for nanomaterials analysis, providing a direct link between spatial and chemical information. However, using it for precisely determining chemical compositions presents challenges of noisy data from low X-ray yields and mixed signals from phases that overlap along the electron beam trajectory. Here, we…
▽ More
Energy dispersive X-ray (EDX) spectroscopy in the transmission electron microscope is a key tool for nanomaterials analysis, providing a direct link between spatial and chemical information. However, using it for precisely determining chemical compositions presents challenges of noisy data from low X-ray yields and mixed signals from phases that overlap along the electron beam trajectory. Here, we introduce a novel method, non-negative matrix factorisation based pan-sharpening (PSNMF), to address these limitations. Leveraging the Poisson nature of EDX spectral noise and binning operations, PSNMF retrieves high quality phase spectral and spatial signatures via consecutive factorisations. After validating PSNMF with synthetic datasets of different noise levels, we illustrate its effectiveness on two distinct experimental cases: a nano-mineralogical lamella, and supported catalytic nanoparticles. Not only does PSNMF obtain accurate phase signatures, datasets reconstructed from the outputs have demonstrably lower noise and better fidelity than from the benchmark denoising method of principle component analysis.
△ Less
Submitted 23 May, 2024;
originally announced May 2024.
-
Unraveling the formation dynamics of metallic femtosecond laser induced periodic surface structures
Authors:
L. Khosravi Khorashad,
A. Reicks,
A. Erickson,
J. E. Shield,
D. Alexander,
A. Laraoui,
G. Gogos,
C. Zuhlke,
C. Argyropoulos
Abstract:
Femtosecond laser surface processing (FLSP) is an emerging fabrication technique to efficiently control the surface morphology of many types of materials including metals. However, the theoretical understanding of the FLSP formation dynamics is not a trivial task, since it involves the interaction of various physical processes (electromagnetic, thermal, fluid dynamics) and remains relatively unexp…
▽ More
Femtosecond laser surface processing (FLSP) is an emerging fabrication technique to efficiently control the surface morphology of many types of materials including metals. However, the theoretical understanding of the FLSP formation dynamics is not a trivial task, since it involves the interaction of various physical processes (electromagnetic, thermal, fluid dynamics) and remains relatively unexplored. In this work, we tackle this problem and present rigorous theoretical results relevant to low-fluence FLSP that accurately match the outcomes of an experimental campaign focused on the formation dynamics of laser induced periodic surface structures (LIPSS) on stainless steel. More specifically, the topology and maximum depth of LIPSS trenches are theoretically and experimentally investigated as a function of the number of laser pulses. Moreover, precise LIPSS morphology measurements are performed using atomic force microscopy (AFM). The proposed comprehensive simulation study is based on two-temperature model (TTM) non-equilibrium thermal simulations coupled with fluid dynamic computations to capture the melting metal phase occurring during FLSP. Our rigorous simulation results are found to be in excellent agreement with the AFM measurements. The presented theoretical framework to model FLSP under low-fluence femtosecond laser pulses will be beneficial to various emerging applications of LIPSS on metallic surfaces, such as cooling high-powered laser diodes and controlling the thermal emission or absorption of metals.
△ Less
Submitted 22 November, 2023; v1 submitted 29 August, 2023;
originally announced August 2023.
-
Machine-learning-informed parameter estimation improves the reliability of spinal cord diffusion MRI
Authors:
Ting Gong,
Francesco Grussu,
Claudia A. M. Gandini Wheeler-Kingshott,
Daniel C Alexander,
Hui Zhang
Abstract:
Purpose: We address the challenge of inaccurate parameter estimation in diffusion MRI when the signal-to-noise ratio (SNR) is very low, as in the spinal cord. The accuracy of conventional maximum-likelihood estimation (MLE) depends highly on initialisation. Unfavourable choices could result in suboptimal parameter estimates. Current methods to address this issue, such as grid search (GS) can incre…
▽ More
Purpose: We address the challenge of inaccurate parameter estimation in diffusion MRI when the signal-to-noise ratio (SNR) is very low, as in the spinal cord. The accuracy of conventional maximum-likelihood estimation (MLE) depends highly on initialisation. Unfavourable choices could result in suboptimal parameter estimates. Current methods to address this issue, such as grid search (GS) can increase computation time substantially. Methods: We propose a machine learning (ML) informed MLE approach that combines conventional MLE with ML approaches synergistically. ML-based methods have been developed recently to improve the speed and precision of parameter estimation. However, they can generate high systematic bias in estimated parameters when SNR is low. In the proposed ML-MLE approach, an artificial neural network model is trained to provide sensible initialisation for MLE efficiently, with the final solution determined by MLE, avoiding biases typically affecting pure ML estimations. Results: Using parameter estimation of neurite orientation dispersion and density imaging as an example, simulation and in vivo experiments suggest that the ML-MLE method can reduce outlier estimates from conventional MLE in white matter voxels affected by CSF contamination. It also accelerates computation compared to GS-MLE. Conclusion: The ML-MLE method can improve the reliability of parameter estimation with reduced computation time compared to GS-MLE, making it a practical tool for diffusion dataset with low SNR.
△ Less
Submitted 28 January, 2023;
originally announced January 2023.
-
Inverse design of photonic devices with strict foundry fabrication constraints
Authors:
Martin F. Schubert,
Alfred K. C. Cheung,
Ian A. D. Williamson,
Aleksandra Spyra,
David H. Alexander
Abstract:
We introduce a new method for inverse design of nanophotonic devices which guarantees that resulting designs satisfy strict length scale constraints - including minimum width and spacing constraints required by commercial semiconductor foundries. The method adopts several concepts from machine learning to transform the problem of topology optimization with strict length scale constraints to an unc…
▽ More
We introduce a new method for inverse design of nanophotonic devices which guarantees that resulting designs satisfy strict length scale constraints - including minimum width and spacing constraints required by commercial semiconductor foundries. The method adopts several concepts from machine learning to transform the problem of topology optimization with strict length scale constraints to an unconstrained stochastic gradient optimization problem. Specifically, we introduce a conditional generator for feasible designs and adopt a straight-through estimator for backpropagation of gradients to a latent design. We demonstrate the performance and reliability of our method by designing several common integrated photonic components.
△ Less
Submitted 13 June, 2022; v1 submitted 30 January, 2022;
originally announced January 2022.
-
Evaluation of automated airway morphological quantification for assessing fibrosing lung disease
Authors:
Ashkan Pakzad,
Wing Keung Cheung,
Kin Quan,
Nesrin Mogulkoc,
Coline H. M. Van Moorsel,
Brian J. Bartholmai,
Hendrik W. Van Es,
Alper Ezircan,
Frouke Van Beek,
Marcel Veltkamp,
Ronald Karwoski,
Tobias Peikert,
Ryan D. Clay,
Finbar Foley,
Cassandra Braun,
Recep Savas,
Carole Sudre,
Tom Doel,
Daniel C. Alexander,
Peter Wijeratne,
David Hawkes,
Yipeng Hu,
John R Hurst,
Joseph Jacob
Abstract:
Abnormal airway dilatation, termed traction bronchiectasis, is a typical feature of idiopathic pulmonary fibrosis (IPF). Volumetric computed tomography (CT) imaging captures the loss of normal airway tapering in IPF. We postulated that automated quantification of airway abnormalities could provide estimates of IPF disease extent and severity. We propose AirQuant, an automated computational pipelin…
▽ More
Abnormal airway dilatation, termed traction bronchiectasis, is a typical feature of idiopathic pulmonary fibrosis (IPF). Volumetric computed tomography (CT) imaging captures the loss of normal airway tapering in IPF. We postulated that automated quantification of airway abnormalities could provide estimates of IPF disease extent and severity. We propose AirQuant, an automated computational pipeline that systematically parcellates the airway tree into its lobes and generational branches from a deep learning based airway segmentation, deriving airway structural measures from chest CT. Importantly, AirQuant prevents the occurrence of spurious airway branches by thick wave propagation and removes loops in the airway-tree by graph search, overcoming limitations of existing airway skeletonisation algorithms. Tapering between airway segments (intertapering) and airway tortuosity computed by AirQuant were compared between 14 healthy participants and 14 IPF patients. Airway intertapering was significantly reduced in IPF patients, and airway tortuosity was significantly increased when compared to healthy controls. Differences were most marked in the lower lobes, conforming to the typical distribution of IPF-related damage. AirQuant is an open-source pipeline that avoids limitations of existing airway quantification algorithms and has clinical interpretability. Automated airway measurements may have potential as novel imaging biomarkers of IPF severity and disease extent.
△ Less
Submitted 19 November, 2021;
originally announced November 2021.
-
A Measurement of Proton, Deuteron, Triton and Alpha Particle Emission after Nuclear Muon Capture on Al, Si and Ti with the AlCap Experiment
Authors:
AlCap Collaboration,
Andrew Edmonds,
John Quirk,
Ming-Liang Wong,
Damien Alexander,
Robert H. Bernstein,
Aji Daniel,
Eleonora Diociaiuti,
Raffaella Donghia,
Ewen L. Gillies,
Ed V. Hungerford,
Peter Kammel,
Benjamin E. Krikler,
Yoshitaka Kuno,
Mark Lancaster,
R. Phillip Litchfield,
James P. Miller,
Anthony Palladino,
Jose Repond,
Akira Sato,
Ivano Sarra,
Stefano Roberto Soleti,
Vladimir Tishchenko,
Nam H. Tran,
Yoshi Uchida
, et al. (2 additional authors not shown)
Abstract:
Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for charged lepton flavor violation at an unprecedented level of sensitivity. The AlCap experiment measured the yield and energy spectra of protons, deuterons, tritons, and alpha particles emitted after the nuclear capture o…
▽ More
Heavy charged particles after nuclear muon capture are an important nuclear physics background to the muon-to-electron conversion experiments Mu2e and COMET, which will search for charged lepton flavor violation at an unprecedented level of sensitivity. The AlCap experiment measured the yield and energy spectra of protons, deuterons, tritons, and alpha particles emitted after the nuclear capture of muons stopped in Al, Si, and Ti in the low energy range relevant for the muon-to-electron conversion experiments. Individual charged particle types were identified in layered silicon detector packages and their initial energy distributions were unfolded from the observed energy spectra. Detailed information on yields and energy spectra for all observed nuclei are presented in the paper.
△ Less
Submitted 1 April, 2022; v1 submitted 19 October, 2021;
originally announced October 2021.
-
Retrospective Evaluation of an Always-on Cherenkov Imaging System for Radiotherapy Quality Improvement
Authors:
Daniel A. Alexander,
Michael Jermyn,
Petr Bruza,
Rongxiao Zhang,
Erli Chen,
Savannah M. Decker,
Tatum L. McGlynn,
Rory A. Rosselot,
Jae Lee,
Melanie L. Rose,
Benjamin B. Williams,
Brian W. Pogue,
David J. Gladstone,
Lesley A. Jarvis
Abstract:
Purpose: Cherenkov imaging is now clinically available to track the course of radiation therapy as a treatment verification tool. The aim of this work was to discover the benefits of always-on Cherenkov images as a novel incident detection and quality improvement system through retrospective review of imaging in our center.
Methods: Continuous imaging of all patients was attempted during a 12-mo…
▽ More
Purpose: Cherenkov imaging is now clinically available to track the course of radiation therapy as a treatment verification tool. The aim of this work was to discover the benefits of always-on Cherenkov images as a novel incident detection and quality improvement system through retrospective review of imaging in our center.
Methods: Continuous imaging of all patients was attempted during a 12-month period by automating the acquisition of Cherenkov imaging using an always-on commercial system. Multi-camera systems were installed in two treatment bunkers in the radiation oncology clinic at our center and one bunker in an affiliated satellite clinic. Images were acquired as part of normal treatment procedure and reviewed retrospectively with potential incidents flagged for evaluation by the physician and medical physics teams.
Results: In total, 622 patients were imaged as part of this study. In this summary, 9 patients were identified with incidents occurring during their course of treatment that were detected only with Cherenkov imaging. Incidents were found relating to issues during simulation, planning, pre-treatment review, and treatment delivery, however none of the incidents were detected prior to treatment delivery. Primary areas of improvement identified in this study are dose to unintended areas in planning, dose to unintended areas due to positioning, and non-ideal bolus placement during setup. Case studies are presented highlighting the detection of these issues using Cherenkov imaging.
Conclusions: All detected events were deemed below the threshold for reporting, but their observation could lead to quality improvement in practice. Perhaps most importantly, the imaging was seamless with no effort required by the radiotherapy team and provided both real-time and permanent records of what was delivered in each fraction.
△ Less
Submitted 14 October, 2021;
originally announced October 2021.
-
Impact of within-voxel heterogeneity in fibre geometry on spherical deconvolution
Authors:
Ross Callaghan,
Daniel C. Alexander,
Marco Palombo,
Hui Zhang
Abstract:
Axons in white matter have been shown to have varying geometries within a bundle using ex vivo imaging techniques, but what does this mean for diffusion MRI (dMRI) based spherical deconvolution (SD)? SD attempts to estimate the fibre orientation distribution function (fODF) by assuming a single dMRI fibre response function (FRF) for all white matter populations and deconvolving this FRF from the d…
▽ More
Axons in white matter have been shown to have varying geometries within a bundle using ex vivo imaging techniques, but what does this mean for diffusion MRI (dMRI) based spherical deconvolution (SD)? SD attempts to estimate the fibre orientation distribution function (fODF) by assuming a single dMRI fibre response function (FRF) for all white matter populations and deconvolving this FRF from the dMRI signal at each voxel to estimate the fODF. Variable fibre geometry within a bundle however suggests the FRF might not be constant even within a single voxel. We test what impact realistic fibre geometry has on SD by simulating the dMRI signal in a range of realistic white matter numerical phantoms, including synthetic phantoms and real axons segmented from electron microscopy. We demonstrate that variable fibre geometry leads to a variable FRF across axons and that in general no single FRF is effective to recover the underlying fibre orientation distribution function (fODF). This finding suggests that assuming a single FRF can lead to misestimation of the fODF, causing further downstream errors in techniques such as tractography.
△ Less
Submitted 3 March, 2022; v1 submitted 15 March, 2021;
originally announced March 2021.
-
Near-unity broadband omnidirectional emissivity via femtosecond laser surface processing
Authors:
Andrew Reicks,
Alfred Tsubaki,
Mark Anderson,
Jace Wieseler,
Larousse Khosravi Khorashad,
Jeffrey E. Shield,
George Gogos,
Dennis Alexander,
Christos Argyropoulos,
Craig Zuhlke
Abstract:
It is very challenging to achieve near perfect absorption/emission that is both broadband and omnidirectional while utilizing a scalable fabrication process. Femtosecond laser surface processing is an emerging low-cost and large-scale manufacturing technique used to directly and permanently modify the surface properties of a material. The versatility of this technique to produce tailored surface p…
▽ More
It is very challenging to achieve near perfect absorption/emission that is both broadband and omnidirectional while utilizing a scalable fabrication process. Femtosecond laser surface processing is an emerging low-cost and large-scale manufacturing technique used to directly and permanently modify the surface properties of a material. The versatility of this technique to produce tailored surface properties has resulted in a rapidly growing number of applications. Here, we demonstrate near perfect, broadband, omnidirectional emissivity from aluminum surfaces by tuning the laser surface processing parameters including fluence, pulse count, and the ambient gas. Full-wave simulations and experimental results prove that the obtained increase in emissivity is mainly a result of two distinct features produced by femtosecond laser surface processing: the introduction of microscale surface features and the thick oxide layer. This technique leads to functionalized metallic surfaces that are ideal for emerging applications, such as passive radiative cooling and thermal management of spacecraft.
△ Less
Submitted 19 February, 2021; v1 submitted 8 December, 2020;
originally announced December 2020.
-
Mapping complex cell morphology in the grey matter with double diffusion encoding MR: a simulation study
Authors:
Andrada Ianus,
Daniel C. Alexander,
Hui Zhang,
Marco Palombo
Abstract:
This paper investigates the impact of cell body (soma) size and branching of cellular projections on diffusion MR imaging (dMRI) and spectroscopy (dMRS) signals for both standard single diffusion encoding (SDE) and more advanced double diffusion encoding (DDE) measurements using numerical simulations. The aim is to study the ability of dMRI/dMRS to characterize the complex morphology of brain grey…
▽ More
This paper investigates the impact of cell body (soma) size and branching of cellular projections on diffusion MR imaging (dMRI) and spectroscopy (dMRS) signals for both standard single diffusion encoding (SDE) and more advanced double diffusion encoding (DDE) measurements using numerical simulations. The aim is to study the ability of dMRI/dMRS to characterize the complex morphology of brain grey matter, focusing on these two distinctive features. To this end, we employ a recently developed framework to create realistic meshes for Monte Carlo simulations, covering a wide range of soma sizes and branching orders of cellular projections, for diffusivities reflecting both water and metabolites. For SDE sequences, we assess the impact of soma size and branching order on the signal b-value dependence as well as the time dependence of the apparent diffusion coefficient (ADC). For DDE sequences, we assess their impact on the mixing time dependence of the signal angular modulation and of the estimated microscopic anisotropy, a promising contrast derived from DDE measurements. The SDE results show that soma size has a measurable impact on both the b-value and diffusion time dependence, for both water and metabolites. On the other hand, branching order has little impact on either, especially for water. In contrast, the DDE results show that soma size has a measurable impact on the signal angular modulation at short mixing times and the branching order significantly impacts the mixing time dependence of the signal angular modulation as well as of the derived microscopic anisotropy, for both water and metabolites. Our results confirm that soma size can be estimated from SDE based techniques, and most importantly, show for the first time that DDE measurements show sensitivity to the branching of cellular projections, paving the way for non-invasive characterization of grey matter morphology.
△ Less
Submitted 23 July, 2021; v1 submitted 24 September, 2020;
originally announced September 2020.
-
ConFiG: Contextual Fibre Growth to generate realistic axonal packing for diffusion MRI simulation
Authors:
Ross Callaghan,
Daniel C. Alexander,
Marco Palombo,
Hui Zhang
Abstract:
This paper presents Contextual Fibre Growth (ConFiG), an approach to generate white matter numerical phantoms by mimicking natural fibre genesis. ConFiG grows fibres one-by-one, following simple rules motivated by real axonal guidance mechanisms. These simple rules enable ConFiG to generate phantoms with tuneable microstructural features by growing fibres while attempting to meet morphological tar…
▽ More
This paper presents Contextual Fibre Growth (ConFiG), an approach to generate white matter numerical phantoms by mimicking natural fibre genesis. ConFiG grows fibres one-by-one, following simple rules motivated by real axonal guidance mechanisms. These simple rules enable ConFiG to generate phantoms with tuneable microstructural features by growing fibres while attempting to meet morphological targets such as user-specified density and orientation distribution. We compare ConFiG to the state-of-the-art approach based on packing fibres together by generating phantoms in a range of fibre configurations including crossing fibre bundles and orientation dispersion. Results demonstrate that ConFiG produces phantoms with up to 20% higher densities than the state-of-the-art, particularly in complex configurations with crossing fibres. We additionally show that the microstructural morphology of ConFiG phantoms is comparable to real tissue, producing diameter and orientation distributions close to electron microscopy estimates from real tissue as well as capturing complex fibre cross sections. Signals simulated from ConFiG phantoms match real diffusion MRI data well, showing that ConFiG phantoms can be used to generate realistic diffusion MRI data. This demonstrates the feasibility of ConFiG to generate realistic synthetic diffusion MRI data for developing and validating microstructure modelling approaches.
△ Less
Submitted 23 March, 2020;
originally announced March 2020.
-
Image Quality Transfer Enhances Contrast and Resolution of Low-Field Brain MRI in African Paediatric Epilepsy Patients
Authors:
Matteo Figini,
Hongxiang Lin,
Godwin Ogbole,
Felice D Arco,
Stefano B. Blumberg,
David W. Carmichael,
Ryutaro Tanno,
Enrico Kaden,
Biobele J. Brown,
Ikeoluwa Lagunju,
Helen J. Cross,
Delmiro Fernandez-Reyes,
Daniel C. Alexander
Abstract:
1.5T or 3T scanners are the current standard for clinical MRI, but low-field (<1T) scanners are still common in many lower- and middle-income countries for reasons of cost and robustness to power failures. Compared to modern high-field scanners, low-field scanners provide images with lower signal-to-noise ratio at equivalent resolution, leaving practitioners to compensate by using large slice thic…
▽ More
1.5T or 3T scanners are the current standard for clinical MRI, but low-field (<1T) scanners are still common in many lower- and middle-income countries for reasons of cost and robustness to power failures. Compared to modern high-field scanners, low-field scanners provide images with lower signal-to-noise ratio at equivalent resolution, leaving practitioners to compensate by using large slice thickness and incomplete spatial coverage. Furthermore, the contrast between different types of brain tissue may be substantially reduced even at equal signal-to-noise ratio, which limits diagnostic value. Recently the paradigm of Image Quality Transfer has been applied to enhance 0.36T structural images aiming to approximate the resolution, spatial coverage, and contrast of typical 1.5T or 3T images. A variant of the neural network U-Net was trained using low-field images simulated from the publicly available 3T Human Connectome Project dataset. Here we present qualitative results from real and simulated clinical low-field brain images showing the potential value of IQT to enhance the clinical utility of readily accessible low-field MRIs in the management of epilepsy.
△ Less
Submitted 18 March, 2020; v1 submitted 16 March, 2020;
originally announced March 2020.
-
SANDI: a compartment-based model for non-invasive apparent soma and neurite imaging by diffusion MRI
Authors:
Marco Palombo,
Andrada Ianus,
Daniel Nunes,
Michele Guerreri,
Daniel C. Alexander,
Noam Shemesh,
Hui Zhang
Abstract:
This work introduces a compartment-based model for apparent soma and neurite density imaging (SANDI) using non-invasive diffusion-weighted MRI (DW-MRI). The existing conjecture in brain microstructure imaging trough DW-MRI presents water diffusion in white (WM) and grey (GM) matter as restricted diffusion in neurites, modelled by infinite cylinders of null radius embedded in the hindered extra-neu…
▽ More
This work introduces a compartment-based model for apparent soma and neurite density imaging (SANDI) using non-invasive diffusion-weighted MRI (DW-MRI). The existing conjecture in brain microstructure imaging trough DW-MRI presents water diffusion in white (WM) and grey (GM) matter as restricted diffusion in neurites, modelled by infinite cylinders of null radius embedded in the hindered extra-neurite water. The extra-neurite pool in WM corresponds to water in the extra-axonal space, but in GM it combines water in the extra-cellular space with water in soma. While several studies showed that this microstructure model successfully describe DW-MRI data in WM and GM at b<3 ms/{\mum^2}, it has been also shown to fail in GM at high b values (b>>3 ms/{\mum^2}). Here we hypothesize that the unmodelled soma compartment may be responsible for this failure and propose SANDI as a new model of brain microstructure where soma (i.e. cell body of any brain cell type: from neuroglia to neurons) is explicitly included. We assess the effects of size and density of soma on the direction-averaged DW-MRI signal at high b values and the regime of validity of the model using numerical simulations and comparison with experimental data from mouse (bmax = 40 ms/{/mum^2}) and human (bmax = 10 ms/{\mum^2}) brain. We show that SANDI defines new contrasts representing new complementary information on the brain cyto- and myelo-architecture. Indeed, we show for the first-time maps from 25 healthy human subjects of MR soma and neurite signal fractions, that remarkably mirror contrasts of histological images of brain cyto- and myelo-architecture. Although still under validation, SANDI might provide new insight into tissue architecture by introducing a new set of biomarkers of potential great value for biomedical applications and pure neuroscience.
△ Less
Submitted 7 April, 2020; v1 submitted 5 July, 2019;
originally announced July 2019.
-
Machine learning based white matter models with permeability: An experimental study in cuprizone treated in-vivo mouse model of axonal demyelination
Authors:
Ioana Hill,
Marco Palombo,
Mathieu Santin,
Francesca Branzoli,
Anne-Charlotte Philippe,
Demian Wassermann,
Marie-Stephane Aigrot,
Bruno Stankoff,
Anne Baron-Van Evercooren,
Mehdi Felfi,
Dominique Langui,
Hui Zhang,
Stephane Lehericy,
Alexandra Petiet,
Daniel C. Alexander,
Olga Ciccarelli,
Ivana Drobnjak
Abstract:
The intra-axonal water exchange time τi, a parameter associated with axonal permeability, could be an important biomarker for understanding demyelinating pathologies such as Multiple Sclerosis. Diffusion-Weighted MRI is sensitive to changes in permeability, however, the parameter has remained elusive due to the intractability of the mathematical models that incorporate it. Machine learning based c…
▽ More
The intra-axonal water exchange time τi, a parameter associated with axonal permeability, could be an important biomarker for understanding demyelinating pathologies such as Multiple Sclerosis. Diffusion-Weighted MRI is sensitive to changes in permeability, however, the parameter has remained elusive due to the intractability of the mathematical models that incorporate it. Machine learning based computational models can potentially be used to estimate such parameters, and recently, a theoretical framework using a random forest (RF) suggests this is a promising approach. In this study, we adopt such an RF approach and experimentally investigate its suitability as a biomarker for demyelinating pathologies through direct comparison with histology. For this, we use an in-vivo cuprizone (CPZ) mouse model of demyelination with available ex-vivo electron microscopy (EM) data. We test our model on noise-free simulations and find very strong correlations between the predicted and ground truth parameters. For realistic noise levels as in our in-vivo data, the performance is affected, however, the parameters are still well estimated. We apply our RF model on in-vivo data from 8 CPZ and 8 wild-type (WT) mice and validate the RF estimates using histology. We find a strong correlation between the in-vivo RF estimates of τi and the EM measurements of myelin thickness ({ρ_τ}i = 0.82), and between RF estimates and EM measurements of intra-axonal volume fraction ({ρ_f} = 0.98). When comparing τi in CPZ and WT mice we find a statistically significant decrease in the corpus callosum of the CPZ compared to the WT mice, in line with our expectations that τi is lower in regions where the myelin sheath is damaged. Overall, these results demonstrate the suitability of machine learning compartment models with permeability as a potential biomarker for demyelinating pathologies.
△ Less
Submitted 4 July, 2019;
originally announced July 2019.
-
In utero diffusion MRI: challenges, advances, and applications
Authors:
Daan Christiaens,
Paddy J. Slator,
Lucilio Cordero-Grande,
Anthony N. Price,
Maria Deprez,
Daniel C. Alexander,
Mary Rutherford,
Joseph V. Hajnal,
Jana Hutter
Abstract:
In utero diffusion MRI provides unique opportunities to non-invasively study the microstructure of tissue during fetal development. A wide range of developmental processes, such as the growth of white matter tracts in the brain, the maturation of placental villous trees, or the fibres in the fetal heart remain to be studied and understood in detail. Advances in fetal interventions and surgery furt…
▽ More
In utero diffusion MRI provides unique opportunities to non-invasively study the microstructure of tissue during fetal development. A wide range of developmental processes, such as the growth of white matter tracts in the brain, the maturation of placental villous trees, or the fibres in the fetal heart remain to be studied and understood in detail. Advances in fetal interventions and surgery furthermore increase the need for ever more precise antenatal diagnosis from fetal MRI. However, the specific properties of the in utero environment, such as fetal and maternal motion, increased field-of-view, tissue interfaces and safety considerations, are significant challenges for most MRI techniques, and particularly for diffusion. Recent years have seen major improvements, driven by the development of bespoke techniques adapted to these specific challenges in both acquisition and processing. Fetal diffusion MRI, an emerging research tool, is now adding valuable novel information for both research and clinical questions. This paper will highlight specific challenges, outline strategies to target them, and discuss two main applications: fetal brain connectomics and placental maturation.
△ Less
Submitted 28 May, 2019;
originally announced May 2019.
-
Combined Diffusion-Relaxometry MRI to Identify Dysfunction in the Human Placenta
Authors:
Paddy J. Slator,
Jana Hutter,
Marco Palombo,
Laurence H. Jackson,
Alison Ho,
Eleftheria Panagiotaki,
Lucy C. Chappell,
Mary Rutherford,
Joseph V. Hajnal,
Daniel C. Alexander
Abstract:
Purpose: A combined diffusion-relaxometry MR acquisition and analysis pipeline for in-vivo human placenta, which allows for exploration of coupling between T2* and apparent diffusion coefficient (ADC) measurements in a sub 10 minute scan time.
Methods: We present a novel acquisition combining a diffusion prepared spin-echo with subsequent gradient echoes. The placentas of 17 pregnant women were…
▽ More
Purpose: A combined diffusion-relaxometry MR acquisition and analysis pipeline for in-vivo human placenta, which allows for exploration of coupling between T2* and apparent diffusion coefficient (ADC) measurements in a sub 10 minute scan time.
Methods: We present a novel acquisition combining a diffusion prepared spin-echo with subsequent gradient echoes. The placentas of 17 pregnant women were scanned in-vivo, including both healthy controls and participants with various pregnancy complications. We estimate the joint T2*-ADC spectra using an inverse Laplace transform.
Results: T2*-ADC spectra demonstrate clear quantitative separation between normal and dysfunctional placentas.
Conclusions: Combined T2*-diffusivity MRI is promising for assessing fetal and maternal health during pregnancy. The T2*-ADC spectrum potentially provides additional information on tissue microstructure, compared to measuring these two contrasts separately. The presented method is immediately applicable to the study of other organs.
△ Less
Submitted 21 March, 2019; v1 submitted 9 October, 2018;
originally announced October 2018.
-
A generative model of realistic brain cells with application to numerical simulation of diffusion-weighted MR signal
Authors:
Marco Palombo,
Daniel C. Alexander,
Hui Zhang
Abstract:
In this work, we introduce a novel computational framework that we developed to use numerical simulations to investigate the complexity of brain tissue at a microscopic level with a detail never realised before. Directly inspired by the advances in computational neuroscience for modelling brain cells, we propose a generative model that enables us to simulate molecular diffusion within realistic di…
▽ More
In this work, we introduce a novel computational framework that we developed to use numerical simulations to investigate the complexity of brain tissue at a microscopic level with a detail never realised before. Directly inspired by the advances in computational neuroscience for modelling brain cells, we propose a generative model that enables us to simulate molecular diffusion within realistic digitalised brain cells, such as neurons and glia, in a completely controlled and flexible fashion. We validate our new approach by showing an excellent match between the morphology and simulated DW-MR signal of the generated digital model of brain cells and those of digital reconstruction of real brain cells from available open-access databases. We demonstrate the versatility and potentiality of the framework by showing a select set of examples of relevance for the DW-MR community. Further development is ongoing, which will support even more realistic conditions like dense packing of numerous 3D complex cell structures and varying cell surface permeability.
△ Less
Submitted 19 June, 2018;
originally announced June 2018.
-
DESIREE electrospray ion source test bench and setup for Collision Induced Dissociation experiments
Authors:
N. de Ruette,
M. Wolf,
L. Giacomozzi,
J. D. Alexander,
M. Gatchell,
M. H. Stockett,
N. Haag,
H. Zettergren,
H. T. Schmidt,
H. Cederquist
Abstract:
We give a detailed description of an electrospray ion source test bench and a single-pass setup for ion fragmentation studies at the DESIREE infrastructure at Stockholm University. This arrangement allows for collision induced dissociation experiments at center-of-mass energies between 10 eV and 1 keV. Charged fragment are analyzed with respect to their kinetic energies (masses) by means of an ele…
▽ More
We give a detailed description of an electrospray ion source test bench and a single-pass setup for ion fragmentation studies at the DESIREE infrastructure at Stockholm University. This arrangement allows for collision induced dissociation experiments at center-of-mass energies between 10 eV and 1 keV. Charged fragment are analyzed with respect to their kinetic energies (masses) by means of an electrostatic energy analyzer with a wide angular acceptance and adjustable energy resolution.
△ Less
Submitted 9 August, 2018; v1 submitted 14 May, 2018;
originally announced May 2018.
-
First storage of ion beams in the Double Electrostatic Ion-Ring Experiment - DESIREE
Authors:
H. T. Schmidt,
R. D. Thomas,
M. Gatchell,
S. Rosén,
P. Reinhed,
P. Löfgren,
L. Brännholm,
M. Blom,
M. Björkhage,
E. Bäckström,
J. D. Alexander,
S. Leontein,
D. Hanstorp,
H. Zettergren,
L. Liljeby,
A. Källberg,
A. Simonsson,
F. Hellberg,
S. Mannervik,
M. Larsson,
W. D. Geppert,
K. G. Rensfelt,
H. Danared,
A. Paál,
M. Masuda
, et al. (9 additional authors not shown)
Abstract:
We report on the first storage of ion beams in the Double ElectroStatic Ion Ring ExpEriment; DESIREE, at Stockholm University. We have produced beams of atomic carbon anions and small carbon anion molecules (C$_n^-$, $n=1,2,3,4$) in a sputter ion source. The ion beams were accelerated to 10 keV kinetic energy and stored in an electrostatic ion storage ring enclosed in a vacuum chamber at 13 K. For…
▽ More
We report on the first storage of ion beams in the Double ElectroStatic Ion Ring ExpEriment; DESIREE, at Stockholm University. We have produced beams of atomic carbon anions and small carbon anion molecules (C$_n^-$, $n=1,2,3,4$) in a sputter ion source. The ion beams were accelerated to 10 keV kinetic energy and stored in an electrostatic ion storage ring enclosed in a vacuum chamber at 13 K. For 10 keV C$_2^-$ molecular anions we measure the residual-gas limited beam storage lifetime to be 448 s $\pm$ 18 s with two independent detector systems. Using the measured storage lifetimes we estimate that the residual gas pressure is in the 10$^{-14}$ mbar range. When high current ion beams are injected, the number of stored particles does not follow a single exponential decay law as would be expected for stored particles lost solely due to electron detachment in collision with the residual-gas. Instead, we observe a faster initial decay rate, which we ascribe to the effect of the space charge of the ion beam on the storage capacity. %The latter effect becomes insignificant after longer storage times of typically 100-150 seconds and we then observe a constant decay rate due to residual-gas collisions.
△ Less
Submitted 31 March, 2018;
originally announced April 2018.
-
Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain
Authors:
Andrada Ianuş,
Sune N. Jespersen,
Teresa Serradas Duarte,
Daniel C. Alexander,
Ivana Drobnjak,
Noam Shemesh
Abstract:
Microscopic diffusion anisotropy (μA) has been recently gaining increasing attention for its ability to decouple the average compartment anisotropy from orientation dispersion. Advanced diffusion MRI sequences, such as double diffusion encoding (DDE) and double oscillating diffusion encoding (DODE) have been used for mapping μA. However, the time-dependence of μA has not been investigated insofar,…
▽ More
Microscopic diffusion anisotropy (μA) has been recently gaining increasing attention for its ability to decouple the average compartment anisotropy from orientation dispersion. Advanced diffusion MRI sequences, such as double diffusion encoding (DDE) and double oscillating diffusion encoding (DODE) have been used for mapping μA. However, the time-dependence of μA has not been investigated insofar, and furthermore, the accuracy of μA estimation vis-à-vis different b-values was not assessed. Here, we investigate both these concepts using theory, simulation, and experiments in the mouse brain. In the first part, simulations and experimental results show that the conventional estimation of microscopic anisotropy from the difference of D(O)DE sequences with parallel and orthogonal gradient directions yields values that highly depend on the choice of b-value. To mitigate this undesirable bias, we propose a multi-shell approach that harnesses a polynomial fit of the signal difference up to third order terms in b-value. In simulations, this approach yields more accurate μA metrics, which are similar to the ground truth values. The second part of this work uses the proposed multi-shell method to estimate the time/frequency dependence of μA. The data shows either an increase or no change in μA with frequency depending on the region of interest, both in white and gray matter. When comparing the experimental results with simulations, it emerges that simple geometric models such as infinite cylinders with either negligible or finite radii cannot replicate the measured trend, and more complex models, which, for example, incorporate structure along the fibre direction are required. Thus, measuring the time dependence of microscopic anisotropy can provide valuable information for characterizing tissue microstructure.
△ Less
Submitted 21 March, 2019; v1 submitted 5 December, 2017;
originally announced December 2017.
-
Rechargeable redox flow batteries: Maximum current density with electrolyte flow reactant penetration in a serpentine flow structure
Authors:
Xinyou Ke,
Joseph M. Prahl,
J. Iwan D. Alexander,
Robert F. Savinell
Abstract:
Rechargeable redox flow batteries with serpentine flow field designs have been demonstrated to deliver higher current density and power density in medium and large-scale stationary energy storage applications. Nevertheless, the fundamental mechanisms involved with improved current density in flow batteries with flow field designs have not been understood. Here we report a maximum current density c…
▽ More
Rechargeable redox flow batteries with serpentine flow field designs have been demonstrated to deliver higher current density and power density in medium and large-scale stationary energy storage applications. Nevertheless, the fundamental mechanisms involved with improved current density in flow batteries with flow field designs have not been understood. Here we report a maximum current density concept associated with stoichiometric availability of electrolyte reactant flow penetration through the porous electrode that can be achieved in a flow battery system with a "zero-gap"serpentine flow field architecture. This concept can explain a higher current density achieved within allowing reactions of all species soluble in the electrolyte. Further validations with experimental data are confirmed by an example of a vanadium flow battery with a serpentine flow structure over carbon paper electrode.
△ Less
Submitted 20 June, 2017; v1 submitted 3 April, 2017;
originally announced April 2017.
-
Realistic voxel sizes and reduced signal variation in Monte-Carlo simulation for diffusion MR data synthesis
Authors:
Matt G Hall,
Gemma Nedjati-Gilani,
Daniel C Alexander
Abstract:
To synthesize diffusion MR measurements from Monte-Carlo simulation using tissue models with sizes comparable to those of scan voxels. Larger regions enable restricting structures to be modeled in greater detail and improve accuracy and precision in synthesized diffusion-weighted measurements.
We employ a localized intersection checking algorithm during substrate construction and dynamical simul…
▽ More
To synthesize diffusion MR measurements from Monte-Carlo simulation using tissue models with sizes comparable to those of scan voxels. Larger regions enable restricting structures to be modeled in greater detail and improve accuracy and precision in synthesized diffusion-weighted measurements.
We employ a localized intersection checking algorithm during substrate construction and dynamical simulation. Although common during dynamics simulation, a dynamically constructed intersection map is also applied here during substrate construction, facilitating construction of much larger substrates than would be possible with a naive "brute-force" approach. We investigate the approach's performance using a packed cylinder model of white matter, investigating optimal execution time for simulations, convergence of synthesized signals and variance in diffusion-weighted measurements over a wide range of acquisition parameters. The scheme is demonstrated with cylinder-based substrates but is also readily applicable to other geometric primitives, such as spheres or triangles.
The algorithm enables models with far larger substrates to be run with no additional computational cost. The improved sampling reduces bias and variance in synthetic measurements.
The new method improves accuracy, precision, and reproducibility of synthetic measurements in Monte-Carlo simulation-based data synthesis. The larger substrates it makes possible are better able to capture the complexity of the tissue we are modeling, leading to reduced bias and variance in synthesised data, compared to existing implementation of MC simulations.
△ Less
Submitted 13 January, 2017;
originally announced January 2017.
-
Dimethylsilanone generation from pyrolysis of polysiloxanes filled with nanosized silica and ceria/silica
Authors:
Kostiantyn Kulyk,
Henning Zettergren,
Michael Gatchell,
John D. Alexander,
Mykola Borysenko,
Borys Palianytsia,
Mats Larsson,
Tetiana Kulik
Abstract:
Polydimethylsiloxane (PDMS) is a widely used organosilicon polymer often employed in formulations with fine oxide particles for various high temperature applications. Although PDMS is considered to be thermally stable and chemically inert, it is not always clear how the oxide filler influences its thermoresistance, decomposition chemistry and what reactive products are formed in the underlying the…
▽ More
Polydimethylsiloxane (PDMS) is a widely used organosilicon polymer often employed in formulations with fine oxide particles for various high temperature applications. Although PDMS is considered to be thermally stable and chemically inert, it is not always clear how the oxide filler influences its thermoresistance, decomposition chemistry and what reactive products are formed in the underlying thermal reactions. In this work we use temperature programmed desorption mass spectrometry (TPD MS) to study the pyrolysis of PDMS and its composites with nanosized silica and ceria/silica. Our results suggest that the elusive organosilicon compound - dimethylsilanone is generated from PDMS over a broad temperature range (in some cases starting at 70$°$C). The presence of nano-oxides catalyzed this process. Ions characteristic of the fragmentation of dimethylsilanone under electron ionization were assigned with the aid of DFT structure calculations. Possible reaction mechanisms for generating dimethylsilanone were discussed in the context of the calculated kinetic parameters. Observed accompanying products of PDMS pyrolysis, such as tetramethylcyclodisiloxane and hexamethylcyclotrisiloxane, indicate that multiple channels are involved in the dimethylsilanone release.
△ Less
Submitted 1 December, 2016;
originally announced December 2016.
-
Mathematical Modeling of Electrolyte Flow Dynamic Patterns and Volumetric Flow Penetrations in the Flow Channel over Porous Electrode Layered System in Vanadium Flow Battery with Serpentine Flow Field Design
Authors:
Xinyou Ke,
Joseph M. Prahl,
J. Iwan D. Alexander,
Robert F. Savinell
Abstract:
In this work, a two-dimensional mathematical model is developed to study the flow patterns and volumetric flow penetrations in the flow channel over the porous electrode layered system in vanadium flow battery with serpentine flow field design. The flow distributions at the interface between the flow channel and porous electrode are examined. It is found that the non-linear pressure distributions…
▽ More
In this work, a two-dimensional mathematical model is developed to study the flow patterns and volumetric flow penetrations in the flow channel over the porous electrode layered system in vanadium flow battery with serpentine flow field design. The flow distributions at the interface between the flow channel and porous electrode are examined. It is found that the non-linear pressure distributions can distinguish the interface flow distributions under the ideal plug flow and ideal parabolic flow inlet boundary conditions. However, the volumetric flow penetration within the porous electrode beneath the flow channel through the integration of interface flow velocity reveals that this value is identical under both ideal plug flow and ideal parabolic flow inlet boundary conditions. The volumetric flow penetrations under the advection effects of flow channel and landing/rib are estimated. The maximum current density achieved in the flow battery can be predicted based on the 100% amount of electrolyte flow reactant consumption through the porous electrode beneath both flow channel and landing channel. The corresponding theoretical maximum current densities achieved in vanadium flow battery with one and three layers of SGL 10AA carbon paper electrode have reasonable agreement with experimental results under a proper permeability.
△ Less
Submitted 29 October, 2016; v1 submitted 19 October, 2016;
originally announced October 2016.
-
A Simple Analytical Model of Coupled Single Flow Channel over Porous Electrode in Vanadium Redox Flow Battery with Serpentine Flow Channel
Authors:
Xinyou Ke,
J. Iwan D. Alexander,
Joseph M. Prahl,
Robert F. Savinell
Abstract:
A simple analytical model of a layered system comprised of a single passage of a serpentine flow channel and a parallel underlying porous electrode (or porous layer) is proposed. This analytical model is derived from Navier-Stokes motion in the flow channel and Darcy-Brinkman model in the porous layer. The continuities of flow velocity and normal stress are applied at the interface between the flo…
▽ More
A simple analytical model of a layered system comprised of a single passage of a serpentine flow channel and a parallel underlying porous electrode (or porous layer) is proposed. This analytical model is derived from Navier-Stokes motion in the flow channel and Darcy-Brinkman model in the porous layer. The continuities of flow velocity and normal stress are applied at the interface between the flow channel and the porous layer. The effects of the inlet volumetric flow rate, thickness of the flow channel and thickness of a typical carbon fiber paper porous layer on the volumetric flow rate within this porous layer are studied. The maximum current density based on the electrolyte volumetric flow rate is predicted, and found to be consistent with reported numerical simulation. It is found that, for a mean inlet flow velocity of 33.3 cm s-1, the analytical maximum current density is estimated to be 377 mA cm-2, which compares favorably with experimental result reported by others of ~400 mA cm-2.
△ Less
Submitted 16 October, 2016;
originally announced October 2016.
-
Diffusion MRI microstructure models with in vivo human brain Connectom data: results from a multi-group comparison
Authors:
Uran Ferizi,
Benoit Scherrer,
Torben Schneider,
Mohammad Alipoor,
Odin Eufracio,
Rutger H. J. Fick,
Rachid Deriche,
Markus Nilsson,
Ana K. Loya-Olivas,
Mariano Rivera,
Dirk H. J. Poot,
Alonso Ramirez-Manzanares,
Jose L. Marroquin,
Ariel Rokem,
Christian Pötter,
Robert F. Dougherty,
Ken Sakaie,
Claudia Wheeler-Kingshott,
Simon K. Warfield,
Thomas Witzel,
Lawrence L. Wald,
José G. Raya,
Daniel C. Alexander
Abstract:
A large number of mathematical models have been proposed to describe the measured signal in diffusion-weighted (DW) magnetic resonance imaging (MRI) and infer properties about the white matter microstructure. However, a head-to-head comparison of DW-MRI models is critically missing in the field. To address this deficiency, we organized the "White Matter Modeling Challenge" during the International…
▽ More
A large number of mathematical models have been proposed to describe the measured signal in diffusion-weighted (DW) magnetic resonance imaging (MRI) and infer properties about the white matter microstructure. However, a head-to-head comparison of DW-MRI models is critically missing in the field. To address this deficiency, we organized the "White Matter Modeling Challenge" during the International Symposium on Biomedical Imaging (ISBI) 2015 conference. This competition aimed at identifying the DW-MRI models that best predict unseen DW data. in vivo DW-MRI data was acquired on the Connectom scanner at the A.A.Martinos Center (Massachusetts General Hospital) using gradients strength of up to 300 mT/m and a broad set of diffusion times. We focused on assessing the DW signal prediction in two regions: the genu in the corpus callosum, where the fibres are relatively straight and parallel, and the fornix, where the configuration of fibres is more complex. The challenge participants had access to three-quarters of the whole dataset, and their models were ranked on their ability to predict the remaining unseen quarter of data. In this paper we provide both an overview and a more in-depth description of each evaluated model, report the challenge results, and infer trends about the model characteristics that were associated with high model ranking. This work provides a much needed benchmark for DW-MRI models. The acquired data and model details for signal prediction evaluation are provided online to encourage a larger scale assessment of diffusion models in the future.
△ Less
Submitted 9 November, 2016; v1 submitted 25 April, 2016;
originally announced April 2016.
-
Mu2e Technical Design Report
Authors:
L. Bartoszek,
E. Barnes,
J. P. Miller,
J. Mott,
A. Palladino,
J. Quirk,
B. L. Roberts,
J. Crnkovic,
V. Polychronakos,
V. Tishchenko,
P. Yamin,
C. -h. Cheng,
B. Echenard,
K. Flood,
D. G. Hitlin,
J. H. Kim,
T. S. Miyashita,
F. C. Porter,
M. Röhrken,
J. Trevor,
R. -Y. Zhu,
E. Heckmaier,
T. I. Kang,
G. Lim,
W. Molzon
, et al. (238 additional authors not shown)
Abstract:
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the L…
▽ More
The Mu2e experiment at Fermilab will search for charged lepton flavor violation via the coherent conversion process mu- N --> e- N with a sensitivity approximately four orders of magnitude better than the current world's best limits for this process. The experiment's sensitivity offers discovery potential over a wide array of new physics models and probes mass scales well beyond the reach of the LHC. We describe herein the preliminary design of the proposed Mu2e experiment. This document was created in partial fulfillment of the requirements necessary to obtain DOE CD-2 approval.
△ Less
Submitted 16 March, 2015; v1 submitted 21 January, 2015;
originally announced January 2015.
-
Diffusion imaging with stimulated echoes: signal models and experiment design
Authors:
Daniel C. Alexander,
Tim B. Dyrby
Abstract:
Purpose: Stimulated echo acquisition mode (STEAM) diffusion MRI can be advantageous over pulsed-gradient spin-echo (PGSE) for diffusion times that are long compared to $\ttwo$. It is important therefore for biomedical diffusion imaging applications at 7T and above where $\ttwo$ is short. However, imaging gradients in the STEAM sequence contribute much greater diffusion weighting than in PGSE, but…
▽ More
Purpose: Stimulated echo acquisition mode (STEAM) diffusion MRI can be advantageous over pulsed-gradient spin-echo (PGSE) for diffusion times that are long compared to $\ttwo$. It is important therefore for biomedical diffusion imaging applications at 7T and above where $\ttwo$ is short. However, imaging gradients in the STEAM sequence contribute much greater diffusion weighting than in PGSE, but are often ignored during post-processing. We demonstrate here that this can severely bias parameter estimates.
Method: We present models for the STEAM signal for free and restricted diffusion that account for crusher and slice-select (butterfly) gradients to avoid such bias. The butterfly gradients also disrupt experiment design, typically by skewing gradient-vectors towards the slice direction. We propose a simple compensation to the diffusion gradient vector specified to the scanner that counterbalances the butterfly gradients to preserve the intended experiment design.
Results: High-field data fixed from a monkey brain experiments demonstrate the need for both the compensation during acquisition and correct modelling during post-processing for both diffusion tensor imaging and ActiveAx axon-diameter index mapping. Simulations support the results and indicate a similar need in in-vivo human applications.
Conclusion: Correct modelling and compensation are important for practical applications of STEAM diffusion MRI.
△ Less
Submitted 12 June, 2013; v1 submitted 31 May, 2013;
originally announced May 2013.
-
Solar sail propulsion: enabling new capabilities for heliophysics
Authors:
L. Johnson,
R. Young,
D. Alhorn,
A. Heaton,
T. Vansant,
B. Campbell,
R. Pappa,
W. Keats,
P. C. Liewer,
D. Alexander,
J. Ayon,
G. Wawrzyniak,
R. Burton,
D. Carroll,
G. Matloff,
R. Ya. Kezerashvili
Abstract:
Solar sails can play a critical role in enabling solar and heliophysics missions. Solar sail technology within NASA is currently at 80% of TRL-6, suitable for an in-flight technology demonstration. It is conceivable that an initial demonstration could carry scientific payloads that, depending on the type of mission, are commensurate with the goals of the three study panels of the 2010 Heliophysics…
▽ More
Solar sails can play a critical role in enabling solar and heliophysics missions. Solar sail technology within NASA is currently at 80% of TRL-6, suitable for an in-flight technology demonstration. It is conceivable that an initial demonstration could carry scientific payloads that, depending on the type of mission, are commensurate with the goals of the three study panels of the 2010 Heliophysics Survey. Follow-on solar sail missions, leveraging advances in solar sail technology to support Heliophysics Survey goals, would then be feasible. This white paper reports on a sampling of missions enabled by solar sails, the current state of the technology, and what funding is required to advance the current state of technology such that solar sails can enable these missions.
△ Less
Submitted 23 December, 2010;
originally announced December 2010.