-
Additive manufacturing in ceramics: targeting lightweight mirror applications in the visible, ultraviolet and X-ray
Authors:
Carolyn Atkins,
Younes Chahid,
Gregory Lister,
Rhys Tuck,
David Isherwood,
Nan Yu,
Rongyan Sun,
Itsuki Noto,
Kazuya Yamamura,
Marta Civitani,
Gabriele Vecchi,
Giovanni Pareschi,
Simon G. Alcock,
Ioana-Theodora Nistea,
Murilo Bazan Da Silva
Abstract:
Additive manufacturing (AM; 3D printing) has clear benefits in the production of lightweight mirrors for astronomy: it can create optimised lightweight structures and combine multiple components into one. New capabilities in AM ceramics, silicon carbide infiltrated with silicon and fused silica, offer the possibility to combine the design benefits of AM with a material suitable for visible, ultrav…
▽ More
Additive manufacturing (AM; 3D printing) has clear benefits in the production of lightweight mirrors for astronomy: it can create optimised lightweight structures and combine multiple components into one. New capabilities in AM ceramics, silicon carbide infiltrated with silicon and fused silica, offer the possibility to combine the design benefits of AM with a material suitable for visible, ultraviolet and X-ray applications. This paper will introduce the printing methods and post-processing steps to convert AM ceramic samples into reflective mirrors. Surface roughness measurements after abrasive polishing of the AM ceramics will be presented.
△ Less
Submitted 7 July, 2024;
originally announced July 2024.
-
Evaluation of a method for time-of-flight, wavelength and distance calibration for neutron scattering instruments by means of a mini-chopper and standard neutron monitors
Authors:
L. Vergara,
M. Arai,
R. Woracek,
M. Olsson,
A. Quintanilla,
S. Alcock,
J. Nilsson,
K. Kanaki,
P. M. Kadletz,
O. Kirstein,
R. Hall-Wilton,
N. Tsapatsaris
Abstract:
Accurate conversion of neutron time-of-flight (TOF) to wavelength, and its uncertainty, is of fundamental importance to neutron scattering measurements. Especially in cases where instruments are highly configurable, the determination of the absolute wavelength after any change must always be performed. Inspired by the manner with which neutron spectrometers determine the absolute wavelength, we ev…
▽ More
Accurate conversion of neutron time-of-flight (TOF) to wavelength, and its uncertainty, is of fundamental importance to neutron scattering measurements. Especially in cases where instruments are highly configurable, the determination of the absolute wavelength after any change must always be performed. Inspired by the manner with which neutron spectrometers determine the absolute wavelength, we evaluate for the first time, in the author's knowledge, a commonly used method for converting TOF to neutron wavelength, the distance of a monitor from the source of neutrons and we analytically calculate the uncertainty contributions that limit the precision of the conversion. The method was evaluated at the V20 test beamline at the Helmholtz Zentrum Berlin (HZB), emulating the ESS source with a pulse of 2.86 ms length and 14 Hz repetition rate, by using a mini-chopper operated at 140 Hz, beam monitors (BMs) and data acquisition infrastructure. The mini-chopper created well-defined neutron pulses and the BM was placed at two positions, enabling the average wavelength of each of the pulses created to be determined. The used experimental setup resulted in absolute wavelength determination at the monitor positions with a $δλ_{mean} / λ_{mean}$ of $\sim$1.8% for $λ>4$ Å. With a modest increase of the distance between the reference monitor positions a $δλ_{mean} / λ_{mean}$ of below 0.5% can be achieved. Further improvements are possible by using a thinner monitor, smaller chopper disc openings and a higher rotational speed chopper. The method requires only two neutron measurements and doesn't necessitate the use of crystals or complex fitting, and could constitute a suitable addition to imaging, diffraction, reflectometers and small angle neutron scattering instruments, at spallation sources, that do not normally utilise fast choppers.
△ Less
Submitted 3 November, 2022;
originally announced November 2022.
-
Rate-capability of the VMM3a Front End in the RD51 Scalable Readout System
Authors:
D. Pfeiffer,
L. Scharenberg,
P. Schwäbig,
S. Alcock,
F. Brunbauer,
M. J. Christensen,
K. Desch,
K. Flöthner,
F. Garcia,
R. Hall-Wilton,
M. Hracek,
G. Iakovidis,
D. Janssens,
J. Kaminski,
M. Lupberger,
H. Muller,
E. Oliveri,
L. Ropelewski,
A. Rusu,
J. Samarati,
M. van Stenis,
A. Utrobicic,
R. Veenhof
Abstract:
The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use…
▽ More
The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use of Micro-Pattern Gaseous Detectors (MPGDs). As part of the integration of the VMM3a into the SRS, the readout and data transfer scheme was optimised to reach a high rate-capability of the entire readout system and profit from the VMM3a's high single-channel rate-capability of 3.6 Mhits/s. The optimisation focused mainly on the handling of the data output stream of the VMM3a, but also on the development of a trigger-logic between the front-end cards and the DAQ computer. In this article, two firmware implementations of the non-ATLAS continuous readout mode are presented, as well as the implementation of the trigger-logic. Afterwards, a short overview on X-ray imaging results is presented, to illustrate the high rate-capability rom an application point-of-view.
△ Less
Submitted 2 February, 2022; v1 submitted 21 September, 2021;
originally announced September 2021.
-
First neutron data recorded at the V20 Test Instrument utilizing prototype chopper systems and beam monitors planned for ESS
Authors:
V. Maulerova,
J. Nilsson,
M. Olsson,
S. Alcock,
A. Quintanilla,
D. Zielinski,
A. Mukai,
F. Issa,
S. Kolya,
W. Smith,
D. Broderick,
K. Löki,
J. Sparger,
R. Woracek,
J. Taylor,
T. Richter,
R. Hall-Wilton,
O. Kirstein,
N. Tsapatsaris
Abstract:
The main objective of the European Spallation Source (ESS) is to perform consistently high impact neutron scattering science using the highest neutron flux of any facility in its class. This ambition is naturally accompanied by operational challenges related to the vertical integration of the instruments' hardware and software shared between collaborators from 13 European countries. The present wo…
▽ More
The main objective of the European Spallation Source (ESS) is to perform consistently high impact neutron scattering science using the highest neutron flux of any facility in its class. This ambition is naturally accompanied by operational challenges related to the vertical integration of the instruments' hardware and software shared between collaborators from 13 European countries. The present work will detail integration tests performed at the V20 Test Instrument at Helmholtz-Zentrum Berlin in Germany. An ESS chopper prototype was successfully controlled through the ESS Chopper Integration Controller (CHIC) and Experimental Physics and Industrial Control System (EPICS). Neutron data were successfully collected and time stamped using neutron beam monitors, the ESS prototype detector readout electronics and the Data Management Software Center (DMSC) data acquisition (DAQ) software. Chopper rotation events were timestamped and the chopper disk showed excellent stability and neutron absorption characteristics. The test resulted in (i) the expected time-of-flight (TOF) response, (ii) collected data that compared well with instrument reference data and (iii) revealing the diagnostic power of the performed integration tests. The results of this integration test validate the ESS chopper and detector DAQ architecture choices.
△ Less
Submitted 21 August, 2019;
originally announced August 2019.
-
I22: SAXS/WAXS beamline at Diamond Light Source -- an overview of 10 years operation
Authors:
A. J. Smith,
S. G. Alcock,
L. S. Davidson,
J. H. Emmins,
J. C. Hiller Bardsley,
P. Holloway,
M. Malfois,
A. R. Marshall,
C. L. Pizzey,
S. E. Rogers,
O. Shebanova,
T. Snow,
J. P. Sutter,
E. P. Williams,
N. J. Terrill
Abstract:
Beamline I22 at Diamond Light Source is dedicated to the study of soft matter systems from both biological and materials science. The beamline can operate in the range 3.7 keV to 22 keV for transmission SAXS and 14 keV to 20 keV for microfocus SAXS with beamsizes 240 x 60 μm$^{2}$ spot [Full width half maximum (FWHM) Horizontal (H) x Vertical (V)] at sample for the main beamline, and approximately…
▽ More
Beamline I22 at Diamond Light Source is dedicated to the study of soft matter systems from both biological and materials science. The beamline can operate in the range 3.7 keV to 22 keV for transmission SAXS and 14 keV to 20 keV for microfocus SAXS with beamsizes 240 x 60 μm$^{2}$ spot [Full width half maximum (FWHM) Horizontal (H) x Vertical (V)] at sample for the main beamline, and approximately 10 x 10 μm$^{2}$ for the dedicated microfocussing platform. There is a versatile sample platform for accommodating a range of facility, and user developed, sample environments. The high brilliance of the insertion device source on I22 allows structural investigation of materials under extreme environments (for example fluid flow at high pressures and temperatures). I22 provides reliable access to millisecond timescales, essential to understanding kinetic processes such as early folding events in proteins or structural evolution in polymers and colloids.
△ Less
Submitted 2 September, 2020; v1 submitted 13 March, 2019;
originally announced March 2019.
-
A facility for the analysis of the electronic structures of solids and their surfaces by synchrotron radiation photoelectron spectroscopy
Authors:
M. Hoesch,
T. K. Kim,
P. Dudin,
H. Wang,
S. Scott,
P. Harris,
S. Patel,
M. Matthews,
D. Hawkins,
S. G. Alcock,
T. Richter,
J. J. Mudd,
M. Basham,
L. Pratt,
P. Leicester,
E. C. Longhi,
A. Tamai,
F. Baumberger
Abstract:
A synchrotron radiation beamline in the photon energy range of 18 - 240 eV and an electron spectroscopy end station have been constructed at the 3 GeV Diamond Light Source storage ring. The instrument features a variable polarisation undulator, a high resolution monochromator, a re-focussing system to form a beam spot of 50x50 micrometer^2 and an end station for angle-resolved photoelectron spectr…
▽ More
A synchrotron radiation beamline in the photon energy range of 18 - 240 eV and an electron spectroscopy end station have been constructed at the 3 GeV Diamond Light Source storage ring. The instrument features a variable polarisation undulator, a high resolution monochromator, a re-focussing system to form a beam spot of 50x50 micrometer^2 and an end station for angle-resolved photoelectron spectroscopy (ARPES) including a 6-degrees-of-freedom cryogenic sample manipulator. The beamline design and its performance allow for a highly productive and precise use of the ARPES technique at an energy resolution of 10 - 15 meV for fast k-space mapping studies with a photon flux up to 2 10^13 ph/sec and well below 3 meV for high resolution spectra.
△ Less
Submitted 21 December, 2016;
originally announced December 2016.