Long-distance chronometric leveling with a portable optical clock
Authors:
J. Grotti,
I. Nosske,
S. B. Koller,
S. Herbers,
H. Denker,
L. Timmen,
G. Vishnyakova,
G. Grosche,
T. Waterholter,
A. Kuhl,
S. Koke,
E. Benkler,
M. Giunta,
L. Maisenbacher,
A. Matveev,
S. Dörscher,
R. Schwarz,
A. Al-Masoudi,
T. W. Hänsch,
Th. Udem,
R. Holzwarth,
C. Lisdat
Abstract:
We have measured the geopotential difference between two locations separated by $457~\mathrm{km}$ by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The $^{87}$Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured…
▽ More
We have measured the geopotential difference between two locations separated by $457~\mathrm{km}$ by comparison of two optical lattice clocks via an interferometric fiber link, utilizing the gravitational redshift of the clock transition frequency. The $^{87}$Sr clocks have been compared side-by-side before and after one of the clocks was moved to the remote location. The chronometrically measured geopotential difference of $3918.1(2.6)\,\mathrm{m^2 \, s^{-2}}$ agrees with an independent geodetic determination of $3915.88(0.30)\,\mathrm{m^2 \, s^{-2}}$. The uncertainty of the chronometric geopotential difference is equivalent to an uncertainty of $27~\mathrm{cm}$ in height.
△ Less
Submitted 29 November, 2024; v1 submitted 26 September, 2023;
originally announced September 2023.
-
Long term measurement of the $^{87}$Sr clock frequency at the limit of primary Cs clocks
Authors:
R. Schwarz,
S. Dörscher,
A. Al-Masoudi,
E. Benkler,
T. Legero,
U. Sterr,
S. Weyers,
J. Rahm,
B. Lipphardt,
C. Lisdat
Abstract:
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement…
▽ More
We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement run has been extended by use of a hydrogen maser as flywheel to improve the statistical uncertainty given by the Cs clocks. We determine an averaged transition frequency of $429\:228\:004\:229\:873.00(0.07)$~Hz with $1.5\times10^{-16}$ fractional uncertainty, at the limit of the current realization of the unit hertz. Analysis of the data provides an improved limit on the coupling of the gravitational potential of the Sun to the proton--electron mass ratio $μ$, and confirms the limits on its temporal drift.
△ Less
Submitted 15 May, 2020;
originally announced May 2020.
-
Dynamic decoupling of laser phase noise in compound atomic clocks
Authors:
Sören Dörscher,
Ali Al-Masoudi,
Marcin Bober,
Roman Schwarz,
Richard Hobson,
Uwe Sterr,
Christian Lisdat
Abstract:
The frequency stability achieved by an optical atomic clock ultimately depends on the coherence of its local oscillator. Even the best ultrastable lasers only allow interrogation times of a few seconds, at present. Here we present a universal measurement protocol that overcomes this limitation. Engineered dynamic decoupling of laser phase noise allows any optical atomic clock with high signal-to-n…
▽ More
The frequency stability achieved by an optical atomic clock ultimately depends on the coherence of its local oscillator. Even the best ultrastable lasers only allow interrogation times of a few seconds, at present. Here we present a universal measurement protocol that overcomes this limitation. Engineered dynamic decoupling of laser phase noise allows any optical atomic clock with high signal-to-noise ratio in a single interrogation to reconstruct the laser's phase well beyond its coherence limit. A compound clock is then formed in combination with another optical clock of any type, allowing the latter to achieve significantly higher frequency stability than on its own. We demonstrate implementation of the protocol in a realistic proof-of-principle experiment with a phase reconstruction fidelity of 99 %. The protocol enables minute-long interrogation for the best ultrastable laser systems. Likewise, it can improve clock performance where less stable local oscillators are used, such as in transortable systems.
△ Less
Submitted 29 November, 2019;
originally announced November 2019.
-
Direct comparisons of European primary and secondary frequency standards via satellite techniques
Authors:
F. Riedel,
A. Al-Masoudi,
E. Benkler,
S. Dörscher,
V. Gerginov,
C. Grebing,
S. Häfner,
N. Huntemann,
B. Lipphardt,
C. Lisdat,
E. Peik,
D. Piester,
C. Sanner,
C. Tamm,
S. Weyers,
H. Denker,
L. Timmen,
C. Voigt,
D. Calonico,
G. Cerretto,
G. A. Costanzo,
F. Levi,
I. Sesia,
J. Achkar,
J. Guèna
, et al. (24 additional authors not shown)
Abstract:
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taki…
▽ More
We carried out a 26-day comparison of five simultaneously operated optical clocks and six atomic fountain clocks located at INRIM, LNE-SYRTE, NPL and PTB by using two satellite-based frequency comparison techniques: broadband Two-Way Satellite Time and Frequency Transfer (TWSTFT) and Global Positioning System Precise Point Positioning (GPS PPP). With an enhanced statistical analysis procedure taking into account correlations and gaps in the measurement data, combined overall uncertainties in the range of $1.8 \times 10^{-16}$ to $3.5 \times 10^{-16}$ for the optical clock comparisons were found. The comparison of the fountain clocks yields results with a maximum relative frequency difference of $6.9 \times 10^{-16}$, and combined overall uncertainties in the range of $4.8 \times 10^{-16}$ to $7.7 \times 10^{-16}$.
△ Less
Submitted 9 October, 2019;
originally announced October 2019.
-
Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks
Authors:
B. M. Roberts,
P. Delva,
A. Al-Masoudi,
A. Amy-Klein,
C. Bærentsen,
C. F. A. Baynham,
E. Benkler,
S. Bilicki,
S. Bize,
W. Bowden,
J. Calvert,
V. Cambier,
E. Cantin,
E. A. Curtis,
S. Dörscher,
M. Favier,
F. Frank,
P. Gill,
R. M. Godun,
G. Grosche,
C. Guo,
A. Hees,
I. R. Hill,
R. Hobson,
N. Huntemann
, et al. (29 additional authors not shown)
Abstract:
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17…
▽ More
We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.
△ Less
Submitted 8 July, 2019; v1 submitted 4 July, 2019;
originally announced July 2019.
-
Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty
Authors:
Moustafa Abdel-Hafiz,
Piotr Ablewski,
Ali Al-Masoudi,
Héctor Álvarez Martínez,
Petr Balling,
Geoffrey Barwood,
Erik Benkler,
Marcin Bober,
Mateusz Borkowski,
William Bowden,
Roman Ciuryło,
Hubert Cybulski,
Alexandre Didier,
Miroslav Doležal,
Sören Dörscher,
Stephan Falke,
Rachel M. Godun,
Ramiz Hamid,
Ian R. Hill,
Richard Hobson,
Nils Huntemann,
Yann Le Coq,
Rodolphe Le Targat,
Thomas Legero,
Thomas Lindvall
, et al. (20 additional authors not shown)
Abstract:
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency…
▽ More
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
△ Less
Submitted 13 August, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
A high-performance optical lattice clock based on bosonic atoms
Authors:
Stefano Origlia,
Mysore Srinivas Pramod,
Stephan Schiller,
Yeshpal Singh,
Kai Bongs,
Roman Schwarz,
Ali Al-Masoudi,
Sören Dörscher,
Sofia Herbers,
Sebastian Häfner,
Uwe Sterr,
Christian Lisdat
Abstract:
Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and $2.0\times 10^{-17}$ accuracy, both values improving on previous work by a factor 30. This was enabled by probing the clock transition with an ultra-long inter…
▽ More
Optical lattice clocks with uncertainty and instability in the $10^{-17}$-range and below have so far been demonstrated exclusively using fermions. Here, we demonstrate a bosonic optical lattice clock with $3\times 10^{-18}$ instability and $2.0\times 10^{-17}$ accuracy, both values improving on previous work by a factor 30. This was enabled by probing the clock transition with an ultra-long interrogation time of 4 s, using the long coherence time provided by a cryogenic silicon resonator, by careful stabilization of relevant operating parameters, and by operating at low atom density. This work demonstrates that bosonic clocks, in combination with highly coherent interrogation lasers, are suitable for high-accuracy applications with particular requirements, such as high reliability, transportability, operation in space, or suitability for particular fundamental physics topics. As an example, we determine the $^{88}\textrm{Sr} - ^{87}$Sr isotope shift with 12 mHz uncertainty.
△ Less
Submitted 8 March, 2018;
originally announced March 2018.
-
Lattice-induced photon scattering in an optical lattice clock
Authors:
Sören Dörscher,
Roman Schwarz,
Ali Al-Masoudi,
Stephan Falke,
Uwe Sterr,
Christian Lisdat
Abstract:
We investigate scattering of lattice laser radiation in a strontium optical lattice clock and its implications for operating clocks at interrogation times up to several tens of seconds. Rayleigh scattering does not cause significant decoherence of the atomic superposition state near a magic wavelength. Among the Raman scattering processes, lattice-induced decay of the excited state…
▽ More
We investigate scattering of lattice laser radiation in a strontium optical lattice clock and its implications for operating clocks at interrogation times up to several tens of seconds. Rayleigh scattering does not cause significant decoherence of the atomic superposition state near a magic wavelength. Among the Raman scattering processes, lattice-induced decay of the excited state $(5s5p)\,{}^{3}\mathrm{P}_{0}$ to the ground state $(5s^2)\,{}^{1}\mathrm{S}_{0}$ via the state $(5s5p)\,{}^{3}\mathrm{P}_{1}$ is particularly relevant, as it reduces the effective lifetime of the excited state and gives rise to quantum projection noise in spectroscopy. We observe this process in our experiment and find a decay rate of $556(15)\times 10^{-6}\,\mathrm{s}^{-1}$ per photon recoil energy $E_\mathrm{r}$ of effective lattice depth, which agrees well with the rate we predict from atomic data. We also derive a natural lifetime $τ= 330(140)\,\mathrm{s}$ of the excited state ${}^{3}\mathrm{P}_{0}$ from our observations. Lattice-induced decay thus exceeds spontaneous decay at typical lattice depths used by present clocks. It eventually limits interrogation times in clocks restricted to high-intensity lattices, but can be largely avoided, e.g., by operating them with shallow lattice potentials.
△ Less
Submitted 19 July, 2018; v1 submitted 8 February, 2018;
originally announced February 2018.
-
Test of special relativity using a fiber network of optical clocks
Authors:
P. Delva,
J. Lodewyck,
S. Bilicki,
E. Bookjans,
G. Vallet,
R. Le Targat,
P. -E. Pottie,
C. Guerlin,
F. Meynadier,
C. Le Poncin-Lafitte,
O. Lopez,
A. Amy-Klein,
W. -K. Lee,
N. Quintin,
C. Lisdat,
A. Al-Masoudi,
S. Dörscher,
C. Grebing,
G. Grosche,
A. Kuhl,
S. Raupach,
U. Sterr,
I. R. Hill,
R. Hobson,
W. Bowden
, et al. (6 additional authors not shown)
Abstract:
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted…
▽ More
Phase compensated optical fiber links enable high accuracy atomic clocks separated by thousands of kilometers to be compared with unprecedented statistical resolution. By searching for a daily variation of the frequency difference between four strontium optical lattice clocks in different locations throughout Europe connected by such links, we improve upon previous tests of time dilation predicted by special relativity. We obtain a constraint on the Robertson--Mansouri--Sexl parameter $|α|\lesssim 1.1 \times10^{-8}$ quantifying a violation of time dilation, thus improving by a factor of around two the best known constraint obtained with Ives--Stilwell type experiments, and by two orders of magnitude the best constraint obtained by comparing atomic clocks. This work is the first of a new generation of tests of fundamental physics using optical clocks and fiber links. As clocks improve, and as fiber links are routinely operated, we expect that the tests initiated in this paper will improve by orders of magnitude in the near future.
△ Less
Submitted 12 June, 2017; v1 submitted 13 March, 2017;
originally announced March 2017.
-
A transportable optical lattice clock with $7\times10^{-17}$ uncertainty
Authors:
S. B. Koller,
J. Grotti,
St. Vogt,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
U. Sterr,
Ch. Lisdat
Abstract:
We present a transportable optical clock (TOC) with $^{87}$Sr. Its complete characterization against a stationary lattice clock resulted in a systematic uncertainty of ${7.4 \times 10^{-17}}$ which is currently limited by the statistics of the determination of the residual lattice light shift. The measurements confirm that the systematic uncertainty is reduceable to below the design goal of…
▽ More
We present a transportable optical clock (TOC) with $^{87}$Sr. Its complete characterization against a stationary lattice clock resulted in a systematic uncertainty of ${7.4 \times 10^{-17}}$ which is currently limited by the statistics of the determination of the residual lattice light shift. The measurements confirm that the systematic uncertainty is reduceable to below the design goal of $1 \times 10^{-17}$. The instability of our TOC is $1.3 \times 10^{-15}/\sqrt{(τ/s)}$. Both, the systematic uncertainty and the instability are to our best knowledge currently the best achieved with any type of transportable clock. For autonomous operation the TOC is installed in an air-conditioned car-trailer. It is suitable for chronometric leveling with sub-meter resolution as well as intercontinental cross-linking of optical clocks, which is essential for a redefiniton of the SI second. In addition, the TOC will be used for high precision experiments for fundamental science that are commonly tied to precise frequency measurements and it is a first step to space borne optical clocks
△ Less
Submitted 20 September, 2016;
originally announced September 2016.
-
A clock network for geodesy and fundamental science
Authors:
C. Lisdat,
G. Grosche,
N. Quintin,
C. Shi,
S. M. F. Raupach,
C. Grebing,
D. Nicolodi,
F. Stefani,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
J. -L. Robyr,
N. Chiodo,
S. Bilicki,
E. Bookjans,
A. Koczwara,
S. Koke,
A. Kuhl,
F. Wiotte,
F. Meynadier,
E. Camisard,
M. Abgrall,
M. Lours,
T. Legero,
H. Schnatz
, et al. (10 additional authors not shown)
Abstract:
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of t…
▽ More
Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of the clocks themselves. This is achieved by a phase-coherent optical frequency transfer via a 1415 km long telecom fiber link that enables substantially better precision than classical means of frequency transfer. The fractional precision in comparing the optical clocks of three parts in $10^{17}$ was reached after only 1000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than with any other existing frequency transfer method. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Realization of a time-scale with an accurate optical lattice clock
Authors:
C. Grebing,
A. Al-Masoudi,
S. Dörscher,
S. Häfner,
V. Gerginov,
S. Weyers,
B. Lipphardt,
F. Riehle,
U. Sterr,
C. Lisdat
Abstract:
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a cont…
▽ More
Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a continuous realization of a timescale impractical. In this paper, we demonstrate how this situation can be resolved and that a timescale based on an optical clock can be established that is superior to one based on even the best caesium fountain clocks. The paper also gives further proof of the international consistency of strontium lattice clocks on the $10^{-16}$ accuracy level, which is another prerequisite for a change in the definition of the second.
△ Less
Submitted 22 February, 2016; v1 submitted 12 November, 2015;
originally announced November 2015.
-
Noise and instability of an optical lattice clock
Authors:
Ali Al-Masoudi,
Sören Dörscher,
Sebastian Häfner,
Uwe Sterr,
Christian Lisdat
Abstract:
We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise--limited detection is possible if more than 130~atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-$10^{-16}$ fractional frequency instability allows…
▽ More
We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise--limited detection is possible if more than 130~atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-$10^{-16}$ fractional frequency instability allows to infer the clock stability for different modes of operation. Excellent agreement with experimental observations for the instability of the difference between two interleaved stabilizations is found. We infer a clock instability of $1.6 \times 10^{-16}/\sqrt{τ/ \mathrm{s}}$ as a function of averaging time $τ$ for normal clock operation.
△ Less
Submitted 3 November, 2015; v1 submitted 17 July, 2015;
originally announced July 2015.
-
A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency
Authors:
Stephan Falke,
Nathan Lemke,
Christian Grebing,
Burghard Lipphardt,
Stefan Weyers,
Vladislav Gerginov,
Nils Huntemann,
Christian Hagemann,
Ali Al-Masoudi,
Sebastian Häfner,
Stefan Vogt,
Uwe Sterr,
Christian Lisdat
Abstract:
We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent ag…
▽ More
We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.
△ Less
Submitted 15 August, 2014; v1 submitted 12 December, 2013;
originally announced December 2013.