-
CMS RPC Non-Physics Event Data Automation Ideology
Authors:
A. Dimitrov,
M. Tytgat,
K. Mota Amarilo,
A. Samalan,
K. Skovpen,
G. A. Alves,
E. Alves Coelho,
F. Marujo da Silva,
M. Barroso Ferreira Filho,
E. M. Da Costa,
D. De Jesus Damiao,
S. Fonseca De Souza,
R. Gomes De Souza,
L. Mundim,
H. Nogima,
J. P. Pinheiro,
A. Santoro,
M. Thiel,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Shopova,
G. Sultanov,
L. Litov,
B. Pavlov
, et al. (79 additional authors not shown)
Abstract:
This paper presents a streamlined framework for real-time processing and analysis of condition data from the CMS experiment Resistive Plate Chambers (RPC). Leveraging data streaming, it uncovers correlations between RPC performance metrics, like currents and rates, and LHC luminosity or environmental conditions. The Java-based framework automates data handling and predictive modeling, integrating…
▽ More
This paper presents a streamlined framework for real-time processing and analysis of condition data from the CMS experiment Resistive Plate Chambers (RPC). Leveraging data streaming, it uncovers correlations between RPC performance metrics, like currents and rates, and LHC luminosity or environmental conditions. The Java-based framework automates data handling and predictive modeling, integrating extensive datasets into synchronized, query-optimized tables. By segmenting LHC operations and analyzing larger virtual detector objects, the automation enhances monitoring precision, accelerates visualization, and provides predictive insights, revolutionizing RPC performance evaluation and future behavior modeling.
△ Less
Submitted 11 April, 2025;
originally announced April 2025.
-
The improvement in transmission resilience metrics from reduced outages or faster restoration can be calculated by rerunning historical outage data
Authors:
Arslan Ahmad,
Ian Dobson,
Svetlana Ekisheva,
Christopher Claypool,
Mark Lauby
Abstract:
Transmission utilities routinely collect detailed outage data, including resilience events in which outages bunch up due to weather. The resilience events and their resilience metrics can readily be extracted from this historical outage data. Improvements such as grid hardening or investments in restoration lead to reduced outages or faster restoration. We show how to rerun this history with the e…
▽ More
Transmission utilities routinely collect detailed outage data, including resilience events in which outages bunch up due to weather. The resilience events and their resilience metrics can readily be extracted from this historical outage data. Improvements such as grid hardening or investments in restoration lead to reduced outages or faster restoration. We show how to rerun this history with the effects of the reduced outages or faster restoration included to find the resulting improvement in resilience metrics, thus quantifying the benefits of these investments. This is demonstrated with case studies for specific events (a derecho and a hurricane), and all large events or large thunderstorms in the Midwest USA. Instead of predicting future extreme events with models, which is very challenging, the historical rerun readily quantifies the benefits that a resilience investment would have had if it had been made in the past. The historical rerun is particularly vivid in making the case for resilience investments to stakeholders because it quantifies the benefits for events actually experienced by those stakeholders, rather than for future events predicted with uncertainty.
△ Less
Submitted 13 January, 2025; v1 submitted 10 January, 2025;
originally announced January 2025.
-
Study of the Radiation Hardness of the ATLAS Tile Calorimeter Optical Instrumentation with Run 2 data
Authors:
J. Abdallah,
M. N. Agaras,
A. Ahmad,
P. Bartos,
A. Berrocal Guardia,
D. Bogavac,
F. Carrio Argos,
L. Cerda Alberich,
B. Chargeishvili,
P. Conde Muiño,
A. Cortes-Gonzalez,
A. Gomes,
T. Davidek,
T. Djobava,
A. Durglishvili,
S. Epari,
G. Facini,
J. Faltova,
M. Fontes Medeiros,
J. Glatzer,
A. J. Gomez Delegido,
S. Harkusha,
A. M. Henriques Correia,
M. Kholodenko,
P. Klimek
, et al. (27 additional authors not shown)
Abstract:
This paper presents a study of the radiation hardness of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2. Both the plastic scintillators constituting the detector active media and the wavelength-shifting optical fibres collecting the scintillation light into the photodetector readout are elements susceptible to radiation damage. The dedicated calibration and monitoring syste…
▽ More
This paper presents a study of the radiation hardness of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2. Both the plastic scintillators constituting the detector active media and the wavelength-shifting optical fibres collecting the scintillation light into the photodetector readout are elements susceptible to radiation damage. The dedicated calibration and monitoring systems of the detector (caesium radioactive sources, laser and minimum bias integrator) allow to assess the response of these optical components. Data collected with these systems between 2015 and 2018 are analysed to measure the degradation of the optical instrumentation across Run 2. Moreover, a simulation of the total ionising dose in the calorimeter is employed to study and model the degradation profile as a function of the exposure conditions, both integrated dose and dose rate. The measurement of the relative light output loss in Run 2 is presented and extrapolations to future scenarios are drawn based on current data. The impact of radiation damage on the cell response uniformity is also analysed.
△ Less
Submitted 20 December, 2024;
originally announced December 2024.
-
Gradient Optical Diffraction Tomography
Authors:
Julianna Winnik,
Piotr Zdankowski,
Marzena Stefaniuk,
Azeem Ahmad,
Chao Zuo,
Balpreet S. Ahluwalia,
Maciej Trusiak
Abstract:
Optical diffraction tomography (ODT) enables non-invasive information-rich 3D refractive index (RI) reconstruction of unimpaired transparent biological and technical samples, crucial in biomedical research, optical metrology, materials sciences, and other fields. ODT bypasses the inherent limitations of 2D integrated quantitative phase imaging methods. To increase the signal-to-noise ratio easy-to…
▽ More
Optical diffraction tomography (ODT) enables non-invasive information-rich 3D refractive index (RI) reconstruction of unimpaired transparent biological and technical samples, crucial in biomedical research, optical metrology, materials sciences, and other fields. ODT bypasses the inherent limitations of 2D integrated quantitative phase imaging methods. To increase the signal-to-noise ratio easy-to-implement common-path shearing interferometry setups are successfully combined with low spatiotemporal coherence of illumination. The need for self-interference generated holograms, with small shear values, critically impedes the analysis of dense and thick samples, e.g., cell cultures, tissue sections, and embryos/organoids. Phase gradient imaging techniques, deployed as a popular solution in the small shear regime, up to now were constrained to 2D integrated quasi-quantitative phase imaging and z-scanning for depth resolution. To fill this significant scientific gap, we propose a novel gradient optical diffraction tomography (GODT) method. The GODT uses coherence-tailored illumination-scanning sequence of phase gradient measurements to tomographically reconstruct, for the first time to the best of our knowledge, a derivative of the 3D RI distribution (in the shear direction) with clearly visible 3D sample structure and high sensitivity to its spatial variations. We present a mathematically rigorous theory based on the first-order Rytov approximation behind the new method, validate it using simulations deploying numerical Shepp-Logan target and corroborate experimentally via successful tomographic imaging of the calibrated nano-printed cell phantom and efficient examination of neural cells. This novel imaging modality opens new possibilities in biomedical quantitative phase imaging, advancing the field and putting forward a first of a kind contrast domain: 3D RI gradient.
△ Less
Submitted 13 November, 2024;
originally announced November 2024.
-
Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter
Authors:
M. Aamir,
G. Adamov,
T. Adams,
C. Adloff,
S. Afanasiev,
C. Agrawal,
C. Agrawal,
A. Ahmad,
H. A. Ahmed,
S. Akbar,
N. Akchurin,
B. Akgul,
B. Akgun,
R. O. Akpinar,
E. Aktas,
A. Al Kadhim,
V. Alexakhin,
J. Alimena,
J. Alison,
A. Alpana,
W. Alshehri,
P. Alvarez Dominguez,
M. Alyari,
C. Amendola,
R. B. Amir
, et al. (550 additional authors not shown)
Abstract:
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr…
▽ More
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadronic section. The shower reconstruction method is based on graph neural networks and it makes use of a dynamic reduction network architecture. It is shown that the algorithm is able to capture and mitigate the main effects that normally hinder the reconstruction of hadronic showers using classical reconstruction methods, by compensating for fluctuations in the multiplicity, energy, and spatial distributions of the shower's constituents. The performance of the algorithm is evaluated using test beam data collected in 2018 prototype of the CMS HGCAL accompanied by a section of the CALICE AHCAL prototype. The capability of the method to mitigate the impact of energy leakage from the calorimeter is also demonstrated.
△ Less
Submitted 18 December, 2024; v1 submitted 17 June, 2024;
originally announced June 2024.
-
Low-energy spectrum of the BULLKID detector array operated on surface
Authors:
D. Delicato,
A. Ahmad,
L. Bandiera,
M. Calvo,
M. Cappelli,
G. Del Castello,
M. del Gallo Roccagiovine,
M. Giammei,
V. Guidi,
D. Maiello,
V. Pettinacci,
M. Romagnoni,
M. Tamisari,
A. Cruciani,
A. Mazzolari,
A. Monfardini,
M. Vignati
Abstract:
We present the first continuous operation in a surface lab of BULLKID, a detector for searches of light Dark Matter and precision measurements of the coherent and elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The data presented focusses on one of the central elements of…
▽ More
We present the first continuous operation in a surface lab of BULLKID, a detector for searches of light Dark Matter and precision measurements of the coherent and elastic neutrino-nucleus scattering. The detector consists of an array of 60 cubic silicon particle absorbers of 0.34 g each, sensed by cryogenic kinetic inductance detectors. The data presented focusses on one of the central elements of the array and on its surrounding elements used as veto. The energy spectrum resulting from an exposure of 39 hours to ambient backgrounds, obtained without radiation shields, is flat at the level of $(2.0\pm0.1\,{\rm stat.}\pm0.2\,{\rm syst.})\times10^6$ counts / keV kg days down to the energy threshold of $160\pm13$ eV. The data analysis demonstrates the unique capability of rejecting backgrounds generated from interactions in other sites of the array, stemming from the segmented and monolithic structure of the detector.
△ Less
Submitted 17 April, 2024; v1 submitted 28 August, 2023;
originally announced August 2023.
-
Towards using utility data to quantify how investments would have increased the wind resilience of distribution systems
Authors:
Arslan Ahmad,
Ian Dobson
Abstract:
We quantify resilience with metrics extracted from the historical outage data that is routinely recorded by many distribution utilities. The outage data is coordinated with wind data to relate average outage rates in an area to wind speed measured at a nearby weather station. A past investment in wind hardening would have reduced the outage rates, and the effect of this on metrics can be calculate…
▽ More
We quantify resilience with metrics extracted from the historical outage data that is routinely recorded by many distribution utilities. The outage data is coordinated with wind data to relate average outage rates in an area to wind speed measured at a nearby weather station. A past investment in wind hardening would have reduced the outage rates, and the effect of this on metrics can be calculated by sampling a reduced number of the historical outages and recomputing the metrics. This quantifies the impact that the hardening would have had on customers. This is a tangible way to relate an investment in wind resilience to the benefits it would have had on the lived experience of customers that could help make the case for the investment to the public and regulators. We also quantify the impact of earlier or faster restoration on customer metrics and compare this to the impact of investment in hardening. Overall this is a new and straightforward approach to quantify resilience and justify resilience investments to stakeholders that is directly driven by utility data. The approach driven by data avoids complicated models or modeling assumptions.
△ Less
Submitted 12 December, 2023; v1 submitted 10 June, 2023;
originally announced June 2023.
-
Laser calibration of the ATLAS Tile Calorimeter during LHC Run 2
Authors:
M. N. Agaras,
A. Ahmad,
A. Blanco,
D. Boumediene,
R. Bonnefoy,
D. Calvet,
M. Calvetti,
R. Chadelas,
P. Conde Muino,
A. Cortes Gonzalez,
M. Crouau,
C. Crozatier,
F. Daudon,
T. Davidek,
G. Di Gregorio,
L. Fiorini,
B. Galhardo,
Ph. Gris,
P. Klimek,
P. Lafarguette,
D. Lambert,
S. Leone,
A. Maio,
M. Marjanovic,
F. Martins
, et al. (15 additional authors not shown)
Abstract:
This article reports the laser calibration of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2 data campaign. The upgraded Laser II calibration system is described. The system was commissioned during the first LHC Long Shutdown, exhibiting a stability better than 0.8% for the laser light monitoring. The methods employed to derive the detector calibration factors with data fro…
▽ More
This article reports the laser calibration of the hadronic Tile Calorimeter of the ATLAS experiment in the LHC Run 2 data campaign. The upgraded Laser II calibration system is described. The system was commissioned during the first LHC Long Shutdown, exhibiting a stability better than 0.8% for the laser light monitoring. The methods employed to derive the detector calibration factors with data from the laser calibration runs are also detailed. These allowed to correct for the response fluctuations of the 9852 photomultiplier tubes of the Tile Calorimeter with a total uncertainty of 0.5% plus a luminosity-dependent sub-dominant term. Finally, we report the regular monitoring and performance studies using laser events in both standalone runs and during proton collisions. These studies include channel timing and quality inspection, and photomultiplier linearity and response dependence on anode current.
△ Less
Submitted 5 July, 2023; v1 submitted 28 February, 2023;
originally announced March 2023.
-
Machine Learning based tool for CMS RPC currents quality monitoring
Authors:
E. Shumka,
A. Samalan,
M. Tytgat,
M. El Sawy,
G. A. Alves,
F. Marujo,
E. A. Coelho,
E. M. Da Costa,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
D. De Jesus Damiao,
M. Thiel,
K. Mota Amarilo,
M. Barroso Ferreira Filho,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov
, et al. (83 additional authors not shown)
Abstract:
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly m…
▽ More
The muon system of the CERN Compact Muon Solenoid (CMS) experiment includes more than a thousand Resistive Plate Chambers (RPC). They are gaseous detectors operated in the hostile environment of the CMS underground cavern on the Large Hadron Collider where pp luminosities of up to $2\times 10^{34}$ $\text{cm}^{-2}\text{s}^{-1}$ are routinely achieved. The CMS RPC system performance is constantly monitored and the detector is regularly maintained to ensure stable operation. The main monitorable characteristics are dark current, efficiency for muon detection, noise rate etc. Herein we describe an automated tool for CMS RPC current monitoring which uses Machine Learning techniques. We further elaborate on the dedicated generalized linear model proposed already and add autoencoder models for self-consistent predictions as well as hybrid models to allow for RPC current predictions in a distant future.
△ Less
Submitted 6 February, 2023;
originally announced February 2023.
-
RPC based tracking system at CERN GIF++ facility
Authors:
K. Mota Amarilo,
A. Samalan,
M. Tytgat,
M. El Sawy,
G. A. Alves,
F. Marujo,
E. A. Coelho,
E. M. Da Costa,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
D. De Jesus Damiao,
M. Thiel,
M. Barroso Ferreira Filho,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov
, et al. (83 additional authors not shown)
Abstract:
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system…
▽ More
With the HL-LHC upgrade of the LHC machine, an increase of the instantaneous luminosity by a factor of five is expected and the current detection systems need to be validated for such working conditions to ensure stable data taking. At the CERN Gamma Irradiation Facility (GIF++) many muon detectors undergo such studies, but the high gamma background can pose a challenge to the muon trigger system which is exposed to many fake hits from the gamma background. A tracking system using RPCs is implemented to clean the fake hits, taking profit of the high muon efficiency of these chambers. This work will present the tracking system configuration, used detector analysis algorithm and results.
△ Less
Submitted 29 November, 2022;
originally announced November 2022.
-
Hilbert phase microscopy based on pseudo thermal illumination in Linnik configuration
Authors:
Mikołaj Rogalski,
Maria Cywińska,
Azeem Ahmad,
Krzysztof Patorski,
Vicente Micó,
Balpreet S. Ahluwalia,
Maciej Trusiak
Abstract:
Quantitative phase microscopy (QPM) is often based on recording an object-reference interference pattern and its further phase demodulation. We propose Pseudo Hilbert Phase Microscopy (PHPM) where we combine pseudo thermal light source illumination and Hilbert spiral transform phase demodulation to achieve hybrid hardware-software-driven noise robustness and increase in resolution of single-shot c…
▽ More
Quantitative phase microscopy (QPM) is often based on recording an object-reference interference pattern and its further phase demodulation. We propose Pseudo Hilbert Phase Microscopy (PHPM) where we combine pseudo thermal light source illumination and Hilbert spiral transform phase demodulation to achieve hybrid hardware-software-driven noise robustness and increase in resolution of single-shot coherent QPM. Those advantageous features stem from physically altering the laser spatial coherence and numerically restoring spectrally overlapped object spatial frequencies. Capabilities of the PHPM are demonstrated analyzing calibrated phase targets and live HeLa cells in comparison with laser illumination and phase demodulation via temporal phase shifting and Fourier transform techniques. Performed studies verified unique ability of the PHPM to couple single-shot imaging, noise minimization, and preservation of phase details.
△ Less
Submitted 20 September, 2022;
originally announced September 2022.
-
Multiple damage detection in piezoelectric ceramic sensor using point contact excitation and detection method
Authors:
Sayantani Bhattacharya,
Nitin Yadav,
Azeem Ahmad,
Frank Melandsø,
Anowarul Habib
Abstract:
Lead Zirconate Titanate [(ZrxTi1-x)O3 ]is used to make ultrasound transducers, sensors, and actuators due to its large piezoelectric coefficient. Several surfaces and subsurface micro defects develop within the Lead Zirconate Titanate (PZT) sensor due to delamination, corrosion, huge temperature fluctuation, etc., causing a decline in its performance. It is thus necessary to identify, locate, and…
▽ More
Lead Zirconate Titanate [(ZrxTi1-x)O3 ]is used to make ultrasound transducers, sensors, and actuators due to its large piezoelectric coefficient. Several surfaces and subsurface micro defects develop within the Lead Zirconate Titanate (PZT) sensor due to delamination, corrosion, huge temperature fluctuation, etc., causing a decline in its performance. It is thus necessary to identify, locate, and quantify the defects. Non-Destructive Structural Health Monitoring (SHM) is the most optimal and economical method of evaluation. Traditional ultrasound SHM techniques have a huge impedance mismatch between air and any solid material. And most of the popular signal processing methods define time-series signals in only one domain which gives sub-optimal results. Thus to improve the accuracy of detection point contact excitation and detection methods have been implemented to determine the interaction of ultrasonic waves with microscale defects in the PZT. And Haar Discrete Wavelet Transformation (DWT) is applied to the time series data obtained from the Coulomb coupling setup. Using the above process, defect up to 100 um in diameter could be successfully distinguished and localized.
△ Less
Submitted 7 July, 2022;
originally announced August 2022.
-
Transmission Structured Illumination Microscopy using Tilt-mirror Assembly
Authors:
Krishnendu Samanta,
Azeem Ahmad,
Jean-Claude Tinguely,
Balpreet Singh Ahluwalia,
Joby Joseph
Abstract:
We present experimental demonstration of tilt-mirror assisted transmission structured illumination microscopy (tSIM) that offers a large field of view super resolution imaging. An assembly of custom-designed tilt-mirrors are employed as the illumination module where the sample is excited with the interference of two beams reflected from the opposite pair of mirror facets. Tunable frequency structu…
▽ More
We present experimental demonstration of tilt-mirror assisted transmission structured illumination microscopy (tSIM) that offers a large field of view super resolution imaging. An assembly of custom-designed tilt-mirrors are employed as the illumination module where the sample is excited with the interference of two beams reflected from the opposite pair of mirror facets. Tunable frequency structured patterns are generated by changing the mirror-tilt angle and the hexagonal-symmetric arrangement is considered for the isotropic resolution in three orientations. Utilizing high numerical aperture (NA) objective in standard SIM provides super-resolution compromising with the field-of-view (FOV). Employing low NA (20X/0.4) objective lens detection, we experimentally demonstrate ~ (0.56mm x 0.35mm) size single FOV image with ~1.7- and ~2.4-fold resolution improvement (exploiting various illumination by tuning tilt-mirrors) over the diffraction limit. The results are verified both for the fluorescent beads as well as biological samples. The tSIM geometry decouples the illumination and the collection light paths consequently enabling free change of the imaging objective lens without influencing the spatial frequency of the illumination pattern that are defined by the tilt-mirrors. The large and scalable FoV supported by tSIM will find usage for applications where scanning large areas are necessary as in pathology and applications where images must be correlated both in space and time.
△ Less
Submitted 16 August, 2022;
originally announced August 2022.
-
Image denoising in acoustic field microscopy
Authors:
Shubham Kumar Gupta,
Azeem Ahmad,
Prakhar Kumar,
Frank Melandso,
Anowarul Habib
Abstract:
Scanning acoustic microscopy (SAM) has been employed since microscopic images are widely used for biomedical or materials research. Acoustic imaging is an important and well-established method used in nondestructive testing (NDT), bio-medical imaging, and structural health monitoring.The imaging is frequently carried out with signals of low amplitude, which might result in leading that are noisy a…
▽ More
Scanning acoustic microscopy (SAM) has been employed since microscopic images are widely used for biomedical or materials research. Acoustic imaging is an important and well-established method used in nondestructive testing (NDT), bio-medical imaging, and structural health monitoring.The imaging is frequently carried out with signals of low amplitude, which might result in leading that are noisy and lacking in details of image information. In this work, we attempted to analyze SAM images acquired from low amplitude signals and employed a block matching filter over time domain signals to obtain a denoised image. We have compared the images with conventional filters applied over time domain signals, such as the gaussian filter, median filter, wiener filter, and total variation filter. The noted outcomes are shown in this article.
△ Less
Submitted 7 August, 2022;
originally announced August 2022.
-
From Hours to Seconds: Towards 100x Faster Quantitative Phase Imaging via Differentiable Microscopy
Authors:
Udith Haputhanthri,
Kithmini Herath,
Ramith Hettiarachchi,
Hasindu Kariyawasam,
Azeem Ahmad,
Balpreet S. Ahluwalia,
Chamira U. S. Edussooriya,
Dushan N. Wadduwage
Abstract:
With applications ranging from metabolomics to histopathology, quantitative phase microscopy (QPM) is a powerful label-free imaging modality. Despite significant advances in fast multiplexed imaging sensors and deep-learning-based inverse solvers, the throughput of QPM is currently limited by the speed of electronic hardware. Complementarily, to improve throughput further, here we propose to acqui…
▽ More
With applications ranging from metabolomics to histopathology, quantitative phase microscopy (QPM) is a powerful label-free imaging modality. Despite significant advances in fast multiplexed imaging sensors and deep-learning-based inverse solvers, the throughput of QPM is currently limited by the speed of electronic hardware. Complementarily, to improve throughput further, here we propose to acquire images in a compressed form such that more information can be transferred beyond the existing electronic hardware bottleneck. To this end, we present a learnable optical compression-decompression framework that learns content-specific features. The proposed differentiable quantitative phase microscopy ($\partial μ$) first uses learnable optical feature extractors as image compressors. The intensity representation produced by these networks is then captured by the imaging sensor. Finally, a reconstruction network running on electronic hardware decompresses the QPM images. In numerical experiments, the proposed system achieves compression of $\times$ 64 while maintaining the SSIM of $\sim 0.90$ and PSNR of $\sim 30$ dB on cells. The results demonstrated by our experiments open up a new pathway for achieving end-to-end optimized (i.e., optics and electronic) compact QPM systems that may provide unprecedented throughput improvements.
△ Less
Submitted 9 October, 2023; v1 submitted 23 May, 2022;
originally announced May 2022.
-
Differentiable Microscopy Designs an All Optical Phase Retrieval Microscope
Authors:
Kithmini Herath,
Udith Haputhanthri,
Ramith Hettiarachchi,
Hasindu Kariyawasam,
Raja N. Ahmad,
Azeem Ahmad,
Balpreet S. Ahluwalia,
Chamira U. S. Edussooriya,
Dushan N. Wadduwage
Abstract:
Since the late 16th century, scientists have continuously innovated and developed new microscope types for various applications. Creating a new architecture from the ground up requires substantial scientific expertise and creativity, often spanning years or even decades. In this study, we propose an alternative approach called "Differentiable Microscopy," which introduces a top-down design paradig…
▽ More
Since the late 16th century, scientists have continuously innovated and developed new microscope types for various applications. Creating a new architecture from the ground up requires substantial scientific expertise and creativity, often spanning years or even decades. In this study, we propose an alternative approach called "Differentiable Microscopy," which introduces a top-down design paradigm for optical microscopes. Using all-optical phase retrieval as an illustrative example, we demonstrate the effectiveness of data-driven microscopy design through $\partialμ$. Furthermore, we conduct comprehensive comparisons with competing methods, showcasing the consistent superiority of our learned designs across multiple datasets, including biological samples. To substantiate our ideas, we experimentally validate the functionality of one of the learned designs, providing a proof of concept. The proposed differentiable microscopy framework supplements the creative process of designing new optical systems and would perhaps lead to unconventional but better optical designs.
△ Less
Submitted 24 August, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
Quality Control of Mass-Produced GEM Detectors for the CMS GE1/1 Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
T. Beyrouthy,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (157 additional authors not shown)
Abstract:
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton co…
▽ More
The series of upgrades to the Large Hadron Collider, culminating in the High Luminosity Large Hadron Collider, will enable a significant expansion of the physics program of the CMS experiment. However, the accelerator upgrades will also make the experimental conditions more challenging, with implications for detector operations, triggering, and data analysis. The luminosity of the proton-proton collisions is expected to exceed $2-3\times10^{34}$~cm$^{-2}$s$^{-1}$ for Run 3 (starting in 2022), and it will be at least $5\times10^{34}$~cm$^{-2}$s$^{-1}$ when the High Luminosity Large Hadron Collider is completed for Run 4. These conditions will affect muon triggering, identification, and measurement, which are critical capabilities of the experiment. To address these challenges, additional muon detectors are being installed in the CMS endcaps, based on Gas Electron Multiplier technology. For this purpose, 161 large triple-Gas Electron Multiplier detectors have been constructed and tested. Installation of these devices began in 2019 with the GE1/1 station and will be followed by two additional stations, GE2/1 and ME0, to be installed in 2023 and 2026, respectively. The assembly and quality control of the GE1/1 detectors were distributed across several production sites around the world. We motivate and discuss the quality control procedures that were developed to standardize the performance of the detectors, and we present the final results of the production. Out of 161 detectors produced, 156 detectors passed all tests, and 144 detectors are now installed in the CMS experiment. The various visual inspections, gas tightness tests, intrinsic noise rate characterizations, and effective gas gain and response uniformity tests allowed the project to achieve this high success rate.
△ Less
Submitted 22 March, 2022;
originally announced March 2022.
-
Surface acoustic waves inside polystyrene microparticles through photoacoustic microscopy
Authors:
Abhishek Ranjan,
Anowarul Habib,
Azeem Ahmad,
Balpreet Singh Ahluwalia,
Frank Melandsø
Abstract:
We demonstrate surface acoustic waves inside polystyrene microspheres of different sizes experimentally through photoacoustic microscopy and validate the experimental result with simulation. A novel method for sample preparation of a lifted sample is also presented where the microparticles are suspended in agarose above the surface of the petridish. Another objective of this study was to investiga…
▽ More
We demonstrate surface acoustic waves inside polystyrene microspheres of different sizes experimentally through photoacoustic microscopy and validate the experimental result with simulation. A novel method for sample preparation of a lifted sample is also presented where the microparticles are suspended in agarose above the surface of the petridish. Another objective of this study was to investigate the results with different laser focus hitting on the microparticles and their impact on photoacoustic images and photoacoustic signals. An absorbing microsphere is excited with a pulsed laser of wavelength 532 nm and the photoacoustic signal is detected using a 40 MHz transducer. On analyzing the photoacoustic signals from microspheres, we find the signature of surface acoustic waves.
△ Less
Submitted 20 March, 2022; v1 submitted 31 January, 2022;
originally announced February 2022.
-
Upgrade of the CMS Resistive Plate Chambers for the High Luminosity LHC
Authors:
A. Samalan,
M. Tytgat,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. DaCosta,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Soultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal,
A. Cabrera
, et al. (86 additional authors not shown)
Abstract:
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solen…
▽ More
During the upcoming High Luminosity phase of the Large Hadron Collider (HL-LHC), the integrated luminosity of the accelerator will increase to 3000 fb$^{-1}$. The expected experimental conditions in that period in terms of background rates, event pileup, and the probable aging of the current detectors present a challenge for all the existing experiments at the LHC, including the Compact Muon Solenoid (CMS) experiment. To ensure a highly performing muon system for this period, several upgrades of the Resistive Plate Chamber (RPC) system of the CMS are currently being implemented. These include the replacement of the readout system for the present system, and the installation of two new RPC stations with improved chamber and front-end electronics designs. The current overall status of this CMS RPC upgrade project is presented.
△ Less
Submitted 2 November, 2021; v1 submitted 29 September, 2021;
originally announced September 2021.
-
Label-free chip-based evanescent light scattering super-resolution and superior-contrast optical microscopy (cELS)
Authors:
Nikhil Jayakumar,
Firehun T Dullo,
Vishesh Dubey,
Azeem Ahmad Ahmad,
Jennifer Cauzzo,
Eduarda Mazagao Guerreiro,
Omri Snir,
Natasa Skalko-Basnet,
Krishna Agarwal,
Balpreet Singh Ahluwalia
Abstract:
Chip-based Evanescent Light Scattering (cELS) utilizes the multiple modes of a high-index contrast optical waveguide for near-field illumination of unlabeled samples, thereby repositioning the highest spatial frequencies of the sample into the far-field. The multiple modes scattering off the sample with different phase differences is engineered to have random spatial distributions within the integ…
▽ More
Chip-based Evanescent Light Scattering (cELS) utilizes the multiple modes of a high-index contrast optical waveguide for near-field illumination of unlabeled samples, thereby repositioning the highest spatial frequencies of the sample into the far-field. The multiple modes scattering off the sample with different phase differences is engineered to have random spatial distributions within the integration time of the camera, mitigating the coherent speckle noise. This enables label-free superior-contrast imaging of weakly scattering nanosized specimens such as extra-cellular vesicles (EVs) and liposomes, dynamics of living HeLa cells etc. The article explains and validates experimentally the physics behind cELS by demonstrating a multi-moded straight waveguide as a partially coherent light source. For isotropic super-resolution, spatially incoherent light engineered via multiple-arms waveguide chip and intensity-fluctuation based algorithms are used. The proof-of-concept results are demonstrated on 100 nm polystyrene beads and resolution improvement of close to 2X is shown. cELS also realizes (2-10)X more contrast as opposed to conventional imaging techniques. In addition, cELS platform is miniaturized and enables large field-of-view imaging compared to state of the art label-free techniques. cELS holds a potential for label-free super-resolution imaging of nanosized biological specimens at high-throughput.
△ Less
Submitted 24 February, 2022; v1 submitted 24 August, 2021;
originally announced August 2021.
-
Demystifying speckle field quantitative phase microscopy
Authors:
Azeem Ahmad,
Nikhil Jayakumar,
Balpreet Singh Ahluwalia
Abstract:
Quantitative phase microscopy (QPM) has found significant applications in the field of biomedical imaging which works on the principle of interferometry. The theory behind achieving interference in QPM with conventional light sources such as white light and lasers is very well developed. Recently, the use of dynamic speckle illumination (DSI) in QPM has attracted attention due to its advantages ov…
▽ More
Quantitative phase microscopy (QPM) has found significant applications in the field of biomedical imaging which works on the principle of interferometry. The theory behind achieving interference in QPM with conventional light sources such as white light and lasers is very well developed. Recently, the use of dynamic speckle illumination (DSI) in QPM has attracted attention due to its advantages over conventional light sources such as high spatial phase sensitivity, single shot, scalable field of view (FOV) and resolution. However, the understanding behind obtaining interference fringes in QPM with DSI has not been convincingly covered previously. This imposes a constraint on obtaining interference fringes in QPM using DSI and limits its widespread penetration in the field of biomedical imaging. The present article provides the basic understanding of DSI through both simulation and experiments that is essential to build interference optical microscopy systems such as QPM, digital holographic microscopy and optical coherence tomography. Using the developed theory of DSI we demonstrate its capabilities of using non-identical objective lenses in both arms of the interference microscopy without degrading the interference fringe contrast and providing the flexibility to use user-defined microscope objective lens. It is also demonstrated that the interference fringes are not washed out over a large range of optical path difference (OPD) between the object and the reference arm providing competitive edge over low temporal coherence light sources. The theory and explanation developed here would enable wider penetration of DSI based QPM for applications in biology and material sciences.
△ Less
Submitted 22 July, 2021;
originally announced July 2021.
-
Performance of a Triple-GEM Demonstrator in $pp$ Collisions at the CMS Detector
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstr…
▽ More
After the Phase-2 high-luminosity upgrade to the Large Hadron Collider (LHC), the collision rate and therefore the background rate will significantly increase, particularly in the high $η$ region. To improve both the tracking and triggering of muons, the Compact Muon Solenoid (CMS) Collaboration plans to install triple-layer Gas Electron Multiplier (GEM) detectors in the CMS muon endcaps. Demonstrator GEM detectors were installed in CMS during 2017 to gain operational experience and perform a preliminary investigation of detector performance. We present the results of triple-GEM detector performance studies performed in situ during normal CMS and LHC operations in 2018. The distribution of cluster size and the efficiency to reconstruct high $p_T$ muons in proton--proton collisions are presented as well as the measurement of the environmental background rate to produce hits in the GEM detector.
△ Less
Submitted 22 September, 2021; v1 submitted 20 July, 2021;
originally announced July 2021.
-
Modeling the triple-GEM detector response to background particles for the CMS Experiment
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
I. Azhgirey,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi
, et al. (164 additional authors not shown)
Abstract:
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The…
▽ More
An estimate of environmental background hit rate on triple-GEM chambers is performed using Monte Carlo (MC) simulation and compared to data taken by test chambers installed in the CMS experiment (GE1/1) during Run-2 at the Large Hadron Collider (LHC). The hit rate is measured using data collected with proton-proton collisions at 13 TeV and a luminosity of 1.5$\times10^{34}$ cm$^{-2}$ s$^{-1}$. The simulation framework uses a combination of the FLUKA and Geant4 packages to obtain the hit rate. FLUKA provides the radiation environment around the GE1/1 chambers, which is comprised of the particle flux with momentum direction and energy spectra ranging from $10^{-11}$ to $10^{4}$ MeV for neutrons, $10^{-3}$ to $10^{4}$ MeV for $γ$'s, $10^{-2}$ to $10^{4}$ MeV for $e^{\pm}$, and $10^{-1}$ to $10^{4}$ MeV for charged hadrons. Geant4 provides an estimate of detector response (sensitivity) based on an accurate description of detector geometry, material composition and interaction of particles with the various detector layers. The MC simulated hit rate is estimated as a function of the perpendicular distance from the beam line and agrees with data within the assigned uncertainties of 10-14.5%. This simulation framework can be used to obtain a reliable estimate of background rates expected at the High Luminosity LHC.
△ Less
Submitted 8 July, 2021;
originally announced July 2021.
-
Polarization doping ab initio verification of the concept charge conservation and nonlocality
Authors:
Ashfaq Ahmad,
Pawel Strak,
Pawel Kempisty,
Konrad Sakowski,
Jacek Piechota,
Yoshihiro Kangawa,
Izabella Grzegory,
Michal Leszczynski,
Zbigniew R. Zytkiewicz,
Grzegorz Muziol,
Eva Monroy,
Stanislaw Krukowski,
Agata Kaminska
Abstract:
In this work, we study the emergence of polarization doping in AlxGa1-xN layers with graded composition from a theoretical viewpoint. We demonstrate that the charge conservation law applies for fixed and mobile charges separately, leading to nonlocal compensation phenomena involving bulk fixed and mobile charge and polarization sheet charge at the heterointerfaces. The magnitude of the effect allo…
▽ More
In this work, we study the emergence of polarization doping in AlxGa1-xN layers with graded composition from a theoretical viewpoint. We demonstrate that the charge conservation law applies for fixed and mobile charges separately, leading to nonlocal compensation phenomena involving bulk fixed and mobile charge and polarization sheet charge at the heterointerfaces. The magnitude of the effect allows obtaining technically viable mobile charge density for optoelectronic devices without impurity doping (donors or acceptors). Therefore, it provides an additional tool for the device designer, with the potential to attain high conductivities: high carrier concentrations can be obtained even in materials with high dopant ionization energies, and the mobility is not limited by scattering at ionized impurities.
△ Less
Submitted 22 March, 2022; v1 submitted 2 June, 2021;
originally announced June 2021.
-
Plasmon induced transparency in an air-dielectric grooved parallel plate terahertz waveguide
Authors:
KM Dhriti,
Maidul Islam,
Angana Bhattacharya,
Amir Ahmad,
Gagan Kumar
Abstract:
In this article, we examine plasmon induced transparency (PIT) effect in a parallel plate waveguide (PPWG) comprising of two similar pyramidal shaped grooves. One of the grooves is filled with air, while the other is filled with a dielectric material whose refractive index can be varied. The resonant frequencies corresponding to the air and dielectric grooves in the proposed configuration results…
▽ More
In this article, we examine plasmon induced transparency (PIT) effect in a parallel plate waveguide (PPWG) comprising of two similar pyramidal shaped grooves. One of the grooves is filled with air, while the other is filled with a dielectric material whose refractive index can be varied. The resonant frequencies corresponding to the air and dielectric grooves in the proposed configuration results in the transparency window which can be modulated with the refractive index of the dielectric material. The approach provides flexibility to actively control transparency effect in a waveguide configuration without changing physical dimensions. We examined field profiles in the transparency region to clearly depict the PIT effect. We have employed an analytical model based upon the three-level plasmonic model to validate our numerical findings. Further, we examined the switching and tunability of transparency effect by including silicon layers between the grooves whose conductivity can be varied. Actively tunable response in plasmon induced transparency effect in terahertz waveguides can be significant in the construction of terahertz active components.
△ Less
Submitted 24 December, 2020;
originally announced December 2020.
-
High throughput spatially sensitive single-shot quantitative phase microscopy
Authors:
Azeem Ahmad,
Vishesh Dubey,
Nikhil Jayakumar,
Anowarul Habib,
Ankit Butola,
Mona Nystad,
Ganesh Acharya,
Purusotam Basnet,
Dalip Singh Mehta,
Balpreet Singh Ahluwalia
Abstract:
High space-bandwidth product with high spatial phase sensitivity is indispensable for a single-shot quantitative phase microscopy (QPM) system. It opens avenue for widespread applications of QPM in the field of biomedical imaging. Temporally low coherence length light sources are generally implemented to achieve high spatial phase sensitivity in QPM at the cost of either reduced temporal resolutio…
▽ More
High space-bandwidth product with high spatial phase sensitivity is indispensable for a single-shot quantitative phase microscopy (QPM) system. It opens avenue for widespread applications of QPM in the field of biomedical imaging. Temporally low coherence length light sources are generally implemented to achieve high spatial phase sensitivity in QPM at the cost of either reduced temporal resolution or smaller field of view (FOV). On the contrary, high temporal coherence light sources like lasers are capable of exploiting the full FOV of the QPM systems at the expense of less spatial phase sensitivity. In the present work, we employed pseudo-thermal light source (PTLS) in QPM which overcomes the limitations of conventional light sources. The capabilities of PTLS over conventional light sources are systematically studied and demonstrated on various test objects like USAF resolution chart and thin optical waveguide (height ~ 8 nm). The spatial phase sensitivity of QPM in case of PTLS is measured to be equivalent to that for white light source. The high-speed and large FOV capabilities of PTLS based QPM is demonstrated by high-speed imaging of live sperm cells that is limited by the camera speed and by imaging extra-ordinary large FOV phase imaging on histopathology placenta tissue samples.
△ Less
Submitted 11 December, 2020;
originally announced December 2020.
-
Interstrip Capacitances of the Readout Board used in Large Triple-GEM Detectors for the CMS Muon Upgrade
Authors:
M. Abbas,
M. Abbrescia,
H. Abdalla,
A. Abdelalim,
S. AbuZeid,
A. Agapitos,
A. Ahmad,
A. Ahmed,
W. Ahmed,
C. Aimè,
C. Aruta,
I. Asghar,
P. Aspell,
C. Avila,
J. Babbar,
Y. Ban,
R. Band,
S. Bansal,
L. Benussi,
V. Bhatnagar,
M. Bianco,
S. Bianco,
K. Black,
L. Borgonovi,
O. Bouhali
, et al. (156 additional authors not shown)
Abstract:
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequent…
▽ More
We present analytical calculations, Finite Element Analysis modeling, and physical measurements of the interstrip capacitances for different potential strip geometries and dimensions of the readout boards for the GE2/1 triple-Gas Electron Multiplier detector in the CMS muon system upgrade. The main goal of the study is to find configurations that minimize the interstrip capacitances and consequently maximize the signal-to-noise ratio for the detector. We find agreement at the 1.5--4.8% level between the two methods of calculations and on the average at the 17% level between calculations and measurements. A configuration with halved strip lengths and doubled strip widths results in a measured 27--29% reduction over the original configuration while leaving the total number of strips unchanged. We have now adopted this design modification for all eight module types of the GE2/1 detector and will produce the final detector with this new strip design.
△ Less
Submitted 20 September, 2020;
originally announced September 2020.
-
Multi-modal on-chip nanoscopy and quantitative phase image reveals the morphology of liver sinusoidal enodthelial cells
Authors:
David A. Coucheron,
Ankit Butola,
Karolina Szafranska,
Azeem Ahmad,
Jean-Claude Tinguely,
Peter McCourt,
Paramasivam Senthilkumaran,
Dalip Singh Mehta,
Balpreet Singh Ahluwalia
Abstract:
Visualization of three-dimensional morphological changes in the subcellular structures of a biological specimen is one of the greatest challenges in life science. Despite conspicuous refinements in optical nanoscopy, determination of quantitative changes in subcellular structure, i.e., size and thickness, remains elusive. We present an integrated chip-based optical nanoscopy set-up that provides a…
▽ More
Visualization of three-dimensional morphological changes in the subcellular structures of a biological specimen is one of the greatest challenges in life science. Despite conspicuous refinements in optical nanoscopy, determination of quantitative changes in subcellular structure, i.e., size and thickness, remains elusive. We present an integrated chip-based optical nanoscopy set-up that provides a lateral optical resolution of 61 nm combined with a highly sensitive quantitative phase microscopy (QPM) system with a spatial phase sensitivity of $\pm$20 mrad. We use the system to obtain the 3D morphology of liver sinusoidal endothelial cells (LSECs) combined with super-resolved spatial information. LSECs have a unique morphology with nanopores that are present in the plasma membrane, called fenestration. The fenestrations are grouped in clusters called sieve plates, which are around 100 nm thick. Thus, imaging and quantification of fenestration and sieve plate thickness requires resolution and sensitivity of sub-100 nm along both lateral and axial directions. In the chip-based nanoscope, the optical waveguides are used both for hosting and illuminating the sample. A strong evanescent field is generated on top of the waveguide surface for single molecule fluorescence excitation. The fluorescence signal is captured by an upright microscope, which is converted into a Linnik-type interferometer to sequentially acquire both super-resolved images and quantitative phase information of the sample. The multi-modal microscope provided an estimate of the fenestration diameter of 124$\pm$41 nm and revealed the average estimated thickness of the sieve plates in the range of 91.2$\pm$43.5 nm for two different cells. The combination of these techniques offers visualization of both the lateral size (using nanoscopy) and the thickness map of sieve plates, i.e. discrete clusters fenestrations in QPM mode.
△ Less
Submitted 22 July, 2020;
originally announced July 2020.
-
Beam Divergence Reduction of Vortex Waves with a Tailored Lens and a Tailored Reflector
Authors:
M. Haj Hassan,
B. Sievert,
J. T. Svejda,
A. Mostafa Ahmad,
J. Barowski,
A. Rennings,
I. Rolfes,
A. Sezgin,
D. Erni
Abstract:
In this paper, we present a tailored lens and a tailored reflector in order to reduce the large beam divergence inherent to Orbital Angular Momentum waves (OAM waves-Vortex waves) that are generated by an Uniform Circular Patch Antenna Array (UCA) at 10 GHz. The tailored lens and the tailored reflector are designed by the shape function (5) and (9) around the antenna s center axis, respectively. T…
▽ More
In this paper, we present a tailored lens and a tailored reflector in order to reduce the large beam divergence inherent to Orbital Angular Momentum waves (OAM waves-Vortex waves) that are generated by an Uniform Circular Patch Antenna Array (UCA) at 10 GHz. The tailored lens and the tailored reflector are designed by the shape function (5) and (9) around the antenna s center axis, respectively. The tailored lens is compared to UCA without and with conventional lens. The simulated and measured results show a significant improvement when using the tailored lens. Following, a tailored reflector is implemented and compared to UCA without and with conventional reflector. Firstly, the two reflectors are simulated with an impressed field source to neglect the influence of the UCA. The simulated results of the two reflectors show that the tailored reflector has a better performance than the conventional reflector when the height of the reflector $r_0$ is less than around 1.5 $λ$ and when the opening angle of the reflector theta is less than 38° (for UCA with $d$ of $λ/2$). In addition, the reflectors are simulated with real UCA with different shapes of PCB, which can disturb the reflected waves from the reflector. Two lenses and two reflectors are manufactured and measured in an anechoic chamber and compared to the simulation results. This paper shows that the vortex waves needs a special lens or a special reflector to reduce effictively the beam divergence especially when the radius of the UCA is very large.
△ Less
Submitted 1 July, 2020;
originally announced July 2020.
-
High space-bandwidth in quantitative phase imaging using partially spatially coherent optical coherence microscopy and deep neural network
Authors:
Ankit Butola,
Sheetal Raosaheb Kanade,
Sunil Bhatt,
Vishesh Kumar Dubey,
Anand Kumar,
Azeem Ahmad,
Dilip K Prasad,
Paramasivam Senthilkumaran,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
Quantitative phase microscopy (QPM) is a label-free technique that enables to monitor morphological changes at subcellular level. The performance of the QPM system in terms of spatial sensitivity and resolution depends on the coherence properties of the light source and the numerical aperture (NA) of objective lenses. Here, we propose high space-bandwidth QPM using partially spatially coherent opt…
▽ More
Quantitative phase microscopy (QPM) is a label-free technique that enables to monitor morphological changes at subcellular level. The performance of the QPM system in terms of spatial sensitivity and resolution depends on the coherence properties of the light source and the numerical aperture (NA) of objective lenses. Here, we propose high space-bandwidth QPM using partially spatially coherent optical coherence microscopy (PSC-OCM) assisted with deep neural network. The PSC source synthesized to improve the spatial sensitivity of the reconstructed phase map from the interferometric images. Further, compatible generative adversarial network (GAN) is used and trained with paired low-resolution (LR) and high-resolution (HR) datasets acquired from PSC-OCM system. The training of the network is performed on two different types of samples i.e. mostly homogenous human red blood cells (RBC) and on highly heterogenous macrophages. The performance is evaluated by predicting the HR images from the datasets captured with low NA lens and compared with the actual HR phase images. An improvement of 9 times in space-bandwidth product is demonstrated for both RBC and macrophages datasets. We believe that the PSC-OCM+GAN approach would be applicable in single-shot label free tissue imaging, disease classification and other high-resolution tomography applications by utilizing the longitudinal spatial coherence properties of the light source.
△ Less
Submitted 5 July, 2020;
originally announced July 2020.
-
A transparent waveguide chip for versatile TIRF-based microscopy and nanoscopy
Authors:
Anish Priyadarshi,
Firehun Tsige Dullo,
Deanna L. Wolfson,
Azeem Ahmad,
Nikhil Jayakumar,
Vishesh Dubey,
Jean-Claude Tinguely,
Balpreet Singh Ahluwalia,
Ganapathy Senthil Murugan
Abstract:
Total internal reflection fluorescence microscopy (TIRF) has enabled low-background, live-cell friendly imaging of cell surfaces and other thin samples thanks to the shallow penetration of the evanescent light field into the sample. The implementation of TIRF on optical waveguide chips (c-TIRF) has overcome historical limitations on the magnification and field of view (FOV) compared to lens-based…
▽ More
Total internal reflection fluorescence microscopy (TIRF) has enabled low-background, live-cell friendly imaging of cell surfaces and other thin samples thanks to the shallow penetration of the evanescent light field into the sample. The implementation of TIRF on optical waveguide chips (c-TIRF) has overcome historical limitations on the magnification and field of view (FOV) compared to lens-based TIRF, and further allows the light to be guided in complicated patterns that can be used for advanced imaging techniques or selective stimulation of the sample. However, the opacity of the chips themselves has thus far precluded their use on inverted microscopes and complicated sample preparation and handling. In this work, we introduce a new platform for c-TIRF imaging based on a transparent substrate, which is fully compatible with sample handling and imaging procedures commonly used with a standard #1.5 glass coverslip, and is fabricated using standard complementary metal-oxide-semiconductor (CMOS) techniques, which can easily be scaled up for mass production. We demonstrate its performance on synthetic and biological samples using both upright and inverted microscopes, and show how it can be extended to super-resolution applications, achieving a resolution of 116 nm using super resolution radial fluctuations (SRRF). These new chips retain the scalable FOV of opaque chip-based TIRF and the high axial resolution of TIRF, and have the versatility to be used with many different objective lenses, microscopy methods, and handling techniques. We thus see c-TIRF as a technology primed for widespread adoption, increasing both TIRF's accessibility to users and the range of applications that can benefit from it.
△ Less
Submitted 1 July, 2020; v1 submitted 11 June, 2020;
originally announced June 2020.
-
CMS RPC Background -- Studies and Measurements
Authors:
R. Hadjiiska,
A. Samalan,
M. Tytgat,
N. Zaganidis,
G. A. Alves,
F. Marujo,
F. Torres Da Silva De Araujo,
E. M. Da Costa,
D. De Jesus Damiao,
H. Nogima,
A. Santoro,
S. Fonseca De Souza,
A. Aleksandrov,
P. Iaydjiev,
M. Rodozov,
M. Shopova,
G. Sultanov,
M. Bonchev,
A. Dimitrov,
L. Litov,
B. Pavlov,
P. Petkov,
A. Petrov,
S. J. Qian,
C. Bernal
, et al. (84 additional authors not shown)
Abstract:
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be upd…
▽ More
The expected radiation background in the CMS RPC system has been studied using the MC prediction with the CMS FLUKA simulation of the detector and the cavern. The MC geometry used in the analysis describes very accurately the present RPC system but still does not include the complete description of the RPC upgrade region with pseudorapidity $1.9 < \lvert η\rvert < 2.4$. Present results will be updated with the final geometry description, once it is available. The radiation background has been studied in terms of expected particle rates, absorbed dose and fluence. Two High Luminosity LHC (HL-LHC) scenarios have been investigated - after collecting $3000$ and $4000$ fb$^{-1}$. Estimations with safety factor of 3 have been considered, as well.
△ Less
Submitted 13 December, 2020; v1 submitted 26 May, 2020;
originally announced May 2020.
-
High spatially sensitive quantitative phase imaging assisted with deep neural network for classification of human spermatozoa under stressed condition
Authors:
Ankit Butola,
Daria Popova,
Dilip K Prasad,
Azeem Ahmad,
Anowarul Habib,
Jean Claude Tinguely,
Purusotam Basnet,
Ganesh Acharya,
Paramasivam Senthilkumaran,
Dalip Singh Mehta,
Balpreet Singh Ahluwalia
Abstract:
Sperm cell motility and morphology observed under the bright field microscopy are the only criteria for selecting particular sperm cell during Intracytoplasmic Sperm Injection (ICSI) procedure of Assisted Reproductive Technology (ART). Several factors such as, oxidative stress, cryopreservation, heat, smoking and alcohol consumption, are negatively associated with the quality of sperm cell and fer…
▽ More
Sperm cell motility and morphology observed under the bright field microscopy are the only criteria for selecting particular sperm cell during Intracytoplasmic Sperm Injection (ICSI) procedure of Assisted Reproductive Technology (ART). Several factors such as, oxidative stress, cryopreservation, heat, smoking and alcohol consumption, are negatively associated with the quality of sperm cell and fertilization potential due to the changing of sub-cellular structures and functions which are overlooked. A bright field imaging contrast is insufficient to distinguish tiniest morphological cell features that might influence the fertilizing ability of sperm cell. We developed a partially spatially coherent digital holographic microscope (PSC-DHM) for quantitative phase imaging (QPI) in order to distinguish normal sperm cells from sperm cells under different stress conditions such as cryopreservation, exposure to hydrogen peroxide and ethanol without any labeling. Phase maps of 10,163 sperm cells (2,400 control cells, 2,750 spermatozoa after cryopreservation, 2,515 and 2,498 cells under hydrogen peroxide and ethanol respectively) are reconstructed using the data acquired from PSC-DHM system. Total of seven feedforward deep neural networks (DNN) were employed for the classification of the phase maps for normal and stress affected sperm cells. When validated against the test dataset, the DNN provided an average sensitivity, specificity and accuracy of 84.88%, 95.03% and 85%, respectively. The current approach DNN and QPI techniques of quantitative information can be applied for further improving ICSI procedure and the diagnostic efficiency for the classification of semen quality in regards to their fertilization potential and other biomedical applications in general.
△ Less
Submitted 18 February, 2020;
originally announced February 2020.
-
Negative-ion surface production in hydrogen plasmas: Determination of the negative-ion energy and angle distribution function using mass spectrometry
Authors:
J. Dubois,
K. Achkasov,
D. Kogut,
A. Ahmad,
J. Layet,
A. Simonin,
Gilles Cartry
Abstract:
This work focuses on the understanding of the production mechanism of negative-ions on surface in low pressure plasmas of H2/D2. The negative ions are produced on a HOPG sample (Highly Oriented Pyrolitic Graphite) negatively biased with respect to plasma potential. The negative ions created under the positive ion bombardment are accelerated towards the plasma, self-extracted and detected according…
▽ More
This work focuses on the understanding of the production mechanism of negative-ions on surface in low pressure plasmas of H2/D2. The negative ions are produced on a HOPG sample (Highly Oriented Pyrolitic Graphite) negatively biased with respect to plasma potential. The negative ions created under the positive ion bombardment are accelerated towards the plasma, self-extracted and detected according to their energy and mass by a mass spectrometer placed in front of the sample. The shape of the measured Negative-Ion Energy Distribution Function (NIEDF) strongly differs from the NIEDF of the ions emitted by the sample because of the limited acceptance angle of the mass spectrometer. To get information on the production mechanisms, we propose a method to obtain the distribution functions in energy and angle (NIEADFs) of the negative-ions emitted by the sample. It is based on an a priori determination of the NIEADF and on an a posteriori validation of the choice by comparison of the modelled and experimental NIEDFs.
△ Less
Submitted 25 November, 2019;
originally announced November 2019.
-
Influence of laser spot size at diffuser plane on the longitudinal spatial coherence function of optical coherence microscopy system
Authors:
Kashif Usmani,
Azeem Ahmad,
Rakesh Joshi,
Vishesh Dubey,
Ankit Butola,
Dalip Singh Mehta
Abstract:
Coherence properties and wavelength of light sources are indispensable for optical coherence microscopy/tomography as they greatly influence the signal to noise ratio, axial resolution, and penetration depth of the system. In the present letter, we investigated the longitudinal spatial coherence properties of the pseudo-thermal light source (PTS) as a function of spot size at the diffuser plane, w…
▽ More
Coherence properties and wavelength of light sources are indispensable for optical coherence microscopy/tomography as they greatly influence the signal to noise ratio, axial resolution, and penetration depth of the system. In the present letter, we investigated the longitudinal spatial coherence properties of the pseudo-thermal light source (PTS) as a function of spot size at the diffuser plane, which is controlled by translating microscope objective lens towards or away from the diffuser plane. The axial resolution of PTS is found to be maximum ~ 13 microns for the beam spot size of 3.5 mm at the diffuser plane. The change in the axial resolution of the system as the spot size is increased at the diffuser plane is further confirmed by performing experiments on standard gauge blocks of height difference of 15 microns. Thus, by appropriately choosing the beam spot size at the diffuser plane, any monochromatic laser light source depending on the biological window can be utilized to obtain high axial-resolution with large penetration depth and speckle-free tomographic images of multilayered biological specimens irrespective of the source temporal coherence length. In addition, PTS could be an attractive alternative light source for achieving high axial-resolution without needing chromatic aberration corrected optics and dispersion-compensation mechanism, unlike conventional setups.
△ Less
Submitted 7 April, 2019;
originally announced April 2019.
-
The Compact Linear Collider (CLIC) - 2018 Summary Report
Authors:
The CLIC,
CLICdp collaborations,
:,
T. K. Charles,
P. J. Giansiracusa,
T. G. Lucas,
R. P. Rassool,
M. Volpi,
C. Balazs,
K. Afanaciev,
V. Makarenko,
A. Patapenka,
I. Zhuk,
C. Collette,
M. J. Boland,
A. C. Abusleme Hoffman,
M. A. Diaz,
F. Garay,
Y. Chi,
X. He,
G. Pei,
S. Pei,
G. Shu,
X. Wang,
J. Zhang
, et al. (671 additional authors not shown)
Abstract:
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the…
▽ More
The Compact Linear Collider (CLIC) is a TeV-scale high-luminosity linear $e^+e^-$ collider under development at CERN. Following the CLIC conceptual design published in 2012, this report provides an overview of the CLIC project, its current status, and future developments. It presents the CLIC physics potential and reports on design, technology, and implementation aspects of the accelerator and the detector. CLIC is foreseen to be built and operated in stages, at centre-of-mass energies of 380 GeV, 1.5 TeV and 3 TeV, respectively. CLIC uses a two-beam acceleration scheme, in which 12 GHz accelerating structures are powered via a high-current drive beam. For the first stage, an alternative with X-band klystron powering is also considered. CLIC accelerator optimisation, technical developments and system tests have resulted in an increased energy efficiency (power around 170 MW) for the 380 GeV stage, together with a reduced cost estimate at the level of 6 billion CHF. The detector concept has been refined using improved software tools. Significant progress has been made on detector technology developments for the tracking and calorimetry systems. A wide range of CLIC physics studies has been conducted, both through full detector simulations and parametric studies, together providing a broad overview of the CLIC physics potential. Each of the three energy stages adds cornerstones of the full CLIC physics programme, such as Higgs width and couplings, top-quark properties, Higgs self-coupling, direct searches, and many precision electroweak measurements. The interpretation of the combined results gives crucial and accurate insight into new physics, largely complementary to LHC and HL-LHC. The construction of the first CLIC energy stage could start by 2026. First beams would be available by 2035, marking the beginning of a broad CLIC physics programme spanning 25-30 years.
△ Less
Submitted 6 May, 2019; v1 submitted 14 December, 2018;
originally announced December 2018.
-
Deep learning architecture LightOCT for diagnostic decision support using optical coherence tomography images of biological samples
Authors:
Ankit Butola,
Dilip K. Prasad,
Azeem Ahmad,
Vishesh Dubey,
Darakhshan Qaiser,
Anurag Srivastava,
Paramsivam Senthilkumaran,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
Optical coherence tomography (OCT) is being increasingly adopted as a label-free and non-invasive technique for biomedical applications such as cancer and ocular disease diagnosis. Diagnostic information for these tissues is manifest in textural and geometric features of the OCT images, which are used by human expertise to interpret and triage. However, it suffers delays due to the long process of…
▽ More
Optical coherence tomography (OCT) is being increasingly adopted as a label-free and non-invasive technique for biomedical applications such as cancer and ocular disease diagnosis. Diagnostic information for these tissues is manifest in textural and geometric features of the OCT images, which are used by human expertise to interpret and triage. However, it suffers delays due to the long process of the conventional diagnostic procedure and shortage of human expertise. Here, a custom deep learning architecture, LightOCT, is proposed for the classification of OCT images into diagnostically relevant classes. LightOCT is a convolutional neural network with only two convolutional layers and a fully connected layer, but it is shown to provide excellent training and test results for diverse OCT image datasets. We show that LightOCT provides 98.9% accuracy in classifying 44 normal and 44 malignant (invasive ductal carcinoma) breast tissue volumetric OCT images. Also, >96% accuracy in classifying public datasets of ocular OCT images as normal, age-related macular degeneration and diabetic macular edema. Additionally, we show ~96% test accuracy for classifying retinal images as belonging to choroidal neovascularization, diabetic macular edema, drusen, and normal samples on a large public dataset of more than 100,000 images. The performance of the architecture is compared with transfer learning based deep neural networks. Through this, we show that LightOCT can provide significant diagnostic support for a variety of OCT images with sufficient training and minimal hyper-parameter tuning. The trained LightOCT networks for the three-classification problem will be released online to support transfer learning on other datasets.
△ Less
Submitted 6 July, 2020; v1 submitted 6 December, 2018;
originally announced December 2018.
-
Highly stable common-path quantitative phase microscope for biomedical imaging
Authors:
Azeem Ahmad,
Vishesh Dubey,
Ankit Butola,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
High temporal stability is the primary requirement of any quantitative phase microscope (QPM) systems for the early stage detection of various human related diseases. The high temporal stability of the system provides accurate measurement of membrane fluctuations of the biological cells, which can be good indicator of various diseases. We developed a single element highly stable common-path QPM sy…
▽ More
High temporal stability is the primary requirement of any quantitative phase microscope (QPM) systems for the early stage detection of various human related diseases. The high temporal stability of the system provides accurate measurement of membrane fluctuations of the biological cells, which can be good indicator of various diseases. We developed a single element highly stable common-path QPM system to obtain temporally stable holograms of the biological specimens. With the proposed system, the temporal stability is obtained ~ 15 mrad without using any vibration isolation table. The capability of the proposed system is demonstrated on USAF resolution chart, polystyrene spheres (dia. 4.5 micron) and human red blood cells (RBCs). The membrane fluctuation of healthy human RBCs is further successfully measured and found to be equal to 63 nm. Contrary to its counterparts, present system offers energy efficient, cost effective and simple way of generating object and reference beam for the development of common-path QPM.
△ Less
Submitted 3 December, 2018;
originally announced December 2018.
-
Sub-nanometer height sensitivity by phase shifting interference microscopy under ambient environmental fluctuations
Authors:
Azeem Ahmad,
Vishesh Dubey,
Ankit Butola,
Jean-Claude Tinguely,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
Phase shifting interferometric (PSI) techniques are among the most sensitive phase measurement methods. Owing to its high sensitivity, any minute phase change caused due to environmental instability results into, inaccurate phase measurement. Consequently, a well calibrated piezo electric transducer (PZT) and highly-stable environment is mandatory for measuring accurate phase map using PSI impleme…
▽ More
Phase shifting interferometric (PSI) techniques are among the most sensitive phase measurement methods. Owing to its high sensitivity, any minute phase change caused due to environmental instability results into, inaccurate phase measurement. Consequently, a well calibrated piezo electric transducer (PZT) and highly-stable environment is mandatory for measuring accurate phase map using PSI implementation. Here, we present a new method of recording temporal phase shifted interferograms and a numerical algorithm, which can retrieve phase maps of the samples with negligible errors under the ambient environmental fluctuations. The method is implemented by recording a video of continuous temporally phase shifted interferograms and phase shifts were calculated between all the data frames using newly developed algorithm with a high accuracy less than or equal to 5.5*10-4*pi rad. To demonstrate the robustness of the proposed method, a manual translation of the stage was employed to introduce continuous temporal phase shift between data frames. The developed algorithm is first verified by performing quantitative phase imaging of optical waveguide and red blood cells using uncalibrated PZT under the influence of vibrations/air turbulence and compared with the well calibrated PZT results. Furthermore, we demonstrated the potential of the proposed approach by acquiring the quantitative phase imaging of an optical waveguide with a rib height of only 2 nm. By using 12-bit CMOS camera the height of shallow rib waveguide is measured with a height sensitivity of 4 Angstrom without using PZT and in presence of environmental fluctuations.
△ Less
Submitted 2 December, 2018;
originally announced December 2018.
-
Characterization of color cross-talk of CCD detectors and its influence in multispectral quantitative phase imaging
Authors:
Azeem Ahmad,
Anand Kumar,
Vishesh Dubey,
Ankit Butola,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
Multi-spectral quantitative phase imaging (QPI) is an emerging imaging modality for wavelength dependent studies of several biological and industrial specimens. Simultaneous multi-spectral QPI is generally performed with color CCD cameras. However, color CCD cameras are suffered from the color crosstalk issue, which needed to be explored. Here, we present a new approach for accurately measuring th…
▽ More
Multi-spectral quantitative phase imaging (QPI) is an emerging imaging modality for wavelength dependent studies of several biological and industrial specimens. Simultaneous multi-spectral QPI is generally performed with color CCD cameras. However, color CCD cameras are suffered from the color crosstalk issue, which needed to be explored. Here, we present a new approach for accurately measuring the color crosstalk of 2D area detectors, without needing prior information about camera specifications. Color crosstalk of two different cameras commonly used in QPI, single chip CCD (1-CCD) and three chip CCD (3-CCD), is systematically studied and compared using compact interference microscopy. The influence of color crosstalk on the fringe width and the visibility of the monochromatic constituents corresponding to three color channels of white light interferogram are studied both through simulations and experiments. It is observed that presence of color crosstalk changes the fringe width and visibility over the imaging field of view. This leads to an unwanted non-uniform background error in the multi-spectral phase imaging of the specimens. It is demonstrated that the color crosstalk of the detector is the key limiting factor for phase measurement accuracy of simultaneous multi-spectral QPI systems.
△ Less
Submitted 5 October, 2018;
originally announced October 2018.
-
Study of longitudinal coherence properties of pseudo thermal light source as a function of source size and temporal coherence
Authors:
Azeem Ahmad,
Tanmoy Mahanty,
Vishesh Dubey,
Ankit Butola,
Balpreet Singh Ahluwalia,
Dalip Singh Mehta
Abstract:
In conventional OCT, broadband light sources are generally utilized to obtain high axial resolution due to their low temporal coherence (TC) length. Purely monochromatic (i.e., high TC length) light sources like laser cannot be implemented to acquire high resolution optically sectioned images of the specimen. Contrary to this, pseudo thermal light source having high TC and low spatial coherence (S…
▽ More
In conventional OCT, broadband light sources are generally utilized to obtain high axial resolution due to their low temporal coherence (TC) length. Purely monochromatic (i.e., high TC length) light sources like laser cannot be implemented to acquire high resolution optically sectioned images of the specimen. Contrary to this, pseudo thermal light source having high TC and low spatial coherence (SC) property can be employed to achieve high axial resolution comparable to broadband light source. In the present letter, a pseudo thermal light source is synthesized by passing a purely monochromatic laser beam through a rotating diffuser. The longitudinal coherence (LC) property of the pseudo thermal light source is studied as a function of source size and TC length. The LC length of the synthesized light source decreased as the source size increased. It is found that LC length of such light source becomes independent of the parent laser TC length for source size of greater than or equal to 3.3 mm and become almost constant at around 30 micron for both the lasers. Thus any monochromatic laser light source can be utilized to obtain high axial resolution in OCT system irrespective of its TC length. The maximum achievable axial resolution is found to be equal to 650 nm corresponding to 1.2 numerical aperture (NA) objective lens at 632 nm wavelength. The findings elucidate that pseudo thermal source being monochromatic in nature can improve the performance of existing OCT systems significantly.
△ Less
Submitted 3 October, 2018;
originally announced October 2018.
-
On Metropolis Growth
Authors:
Syed Amaar Ahmad
Abstract:
We consider the scaling laws, second-order statistics and entropy of the consumed energy of metropolis cities which are hybrid complex systems comprising social networks, engineering systems, agricultural output, economic activity and energy components. We abstract a city in terms of two fundamental variables; $s$ resource cells (of unit area) that represent energy-consuming geographic or spatial…
▽ More
We consider the scaling laws, second-order statistics and entropy of the consumed energy of metropolis cities which are hybrid complex systems comprising social networks, engineering systems, agricultural output, economic activity and energy components. We abstract a city in terms of two fundamental variables; $s$ resource cells (of unit area) that represent energy-consuming geographic or spatial zones (e.g. land, housing or infrastructure etc.) and a population comprising $n$ mobile units that can migrate between these cells. We show that with a constant metropolis area (fixed $s$), the variance and entropy of consumed energy initially increase with $n$, reach a maximum and then eventually diminish to zero as saturation is reached. These metrics are indicators of the spatial mobility of the population. Under certain situations, the variance is bounded as a quadratic function of the mean consumed energy of the metropolis. However, when population and metropolis area are endogenous, growth in the latter is arrested when $n\leq\frac{s}{2}\log(s)$ due to diminished population density. Conversely, the population growth reaches equilibrium when $n\geq {s}\log{n}$ or equivalently when the aggregate of both over-populated and under-populated areas is large. Moreover, we also draw the relationship between our approach and multi-scalar information, when economic dependency between a metropolis's sub-regions is based on the entropy of consumed energy. Finally, if the city's economic size (domestic product etc.) is proportional to the consumed energy, then for a constant population density, we show that the economy scales linearly with the surface area (or $s$).
△ Less
Submitted 15 December, 2017; v1 submitted 7 December, 2017;
originally announced December 2017.
-
R&D towards the CMS RPC Phase-2 upgrade
Authors:
A. Fagot,
A. Cimmino,
S. Crucy,
M. Gul,
A. A. O. Rios,
M. Tytgat,
N. Zaganidis,
S. Aly,
Y. Assran,
A. Radi,
A. Sayed,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese,
P. Verwilligen,
W. Van Doninck,
S. Colafranceschi,
A. Sharma,
L. Benussi,
S. Bianco,
D. Piccolo,
F. Primavera,
V. Bhatnagar
, et al. (71 additional authors not shown)
Abstract:
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle…
▽ More
The high pseudo-rapidity region of the CMS muon system is covered by Cathode Strip Chambers (CSC) only and lacks redundant coverage despite the fact that it is a challenging region for muons in terms of backgrounds and momentum resolution. In order to maintain good efficiency for the muon trigger in this region additional RPCs are planned to be installed in the two outermost stations at low angle named RE3/1 and RE4/1. These stations will use RPCs with finer granularity and good timing resolution to mitigate background effects and to increase the redundancy of the system.
△ Less
Submitted 14 June, 2016;
originally announced June 2016.
-
High rate, fast timing Glass RPC for the high η CMS muon detectors
Authors:
F. Lagarde,
M. Gouzevitch,
I. Laktineh,
V. Buridon,
X. Chen,
C. Combaret,
A. Eynard,
L. Germani,
G. Grenier,
H. Mathez,
L. Mirabito,
A. Petrukhin,
A. Steen,
W. Tromeuraa,
Y. Wang,
A. Gongab,
N. Moreau,
C. de la Taille,
F. Dulucqac,
A. Cimmino,
S. Crucy,
A. Fagot,
M. Gul,
A. A. O. Rios,
M. Tytgat
, et al. (86 additional authors not shown)
Abstract:
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expec…
▽ More
The HL-LHC phase is designed to increase by an order of magnitude the amount of data to be collected by the LHC experiments. To achieve this goal in a reasonable time scale the instantaneous luminosity would also increase by an order of magnitude up to $6.10^{34} cm^{-2} s^{-1}$ . The region of the forward muon spectrometer ($|η| > 1.6$) is not equipped with RPC stations. The increase of the expected particles rate up to $2 kHz/cm^{2}$ (including a safety factor 3) motivates the installation of RPC chambers to guarantee redundancy with the CSC chambers already present. The actual RPC technology of CMS cannot sustain the expected background level. The new technology that will be chosen should have a high rate capability and provides a good spatial and timing resolution. A new generation of Glass-RPC (GRPC) using low-resistivity (LR) glass is proposed to equip at least the two most far away of the four high $η$ muon stations of CMS. First the design of small size prototypes and studies of their performance in high-rate particles flux is presented. Then the proposed designs for large size chambers and their fast-timing electronic readout are examined and preliminary results are provided.
△ Less
Submitted 22 July, 2016; v1 submitted 4 June, 2016;
originally announced June 2016.
-
Performance of Resistive Plate Chambers installed during the first long shutdown of the CMS experiment
Authors:
M. Shopova,
A. Aleksandrov,
R. Hadjiiska,
P. Iaydjiev,
G. Sultanov,
M. Rodozov,
S. Stoykova,
Y. Assran,
A. Sayed,
A. Radi,
S. Aly,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese,
P. Verwilligen,
W. Van Doninck,
S. Colafranceschi,
A. Sharma,
L. Benussi,
S. Bianco,
D. Piccolo,
F. Primavera,
A. Cimmino
, et al. (71 additional authors not shown)
Abstract:
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the L…
▽ More
The CMS experiment, located at the CERN Large Hadron Collider, has a redundant muon system composed by three different detector technologies: Cathode Strip Chambers (in the forward regions), Drift Tubes (in the central region) and Resistive Plate Chambers (both its central and forward regions). All three are used for muon reconstruction and triggering. During the first long shutdown (LS1) of the LHC (2013-2014) the CMS muon system has been upgraded with 144 newly installed RPCs on the forth forward stations. The new chambers ensure and enhance the muon trigger efficiency in the high luminosity conditions of the LHC Run2. The chambers have been successfully installed and commissioned. The system has been run successfully and experimental data has been collected and analyzed. The performance results of the newly installed RPCs will be presented.
△ Less
Submitted 22 May, 2016;
originally announced May 2016.
-
Radiation Tests of Real-Sized Prototype RPCs for the Future CMS RPC Upscope
Authors:
K. S. Lee,
S. Choi,
B. S. Hong,
M. Jo,
J. W. Kang,
M. Kang,
H. Kim,
K. Lee,
S. K. Parka,
A. Cimmino,
S. Crucy,
A. Fagot,
M. Gul,
A. A. O. Rios,
M. Tytgat,
N. Zaganidis,
S. Ali,
Y. Assran,
A. Radi,
A. Sayed,
G. Singh,
M. Abbrescia,
G. Iaselli,
M. Maggi,
G. Pugliese
, et al. (71 additional authors not shown)
Abstract:
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muon…
▽ More
We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muons provided by the SPS H4 beam line at CERN. We applied maximum gamma rates of 1.5 kHz cm-2 provided by 137Cs sources at Korea University and the GIF++ irradiation facility installed at the SPS H4 beam line to examine the rate capabilities of the prototype RPCs. In contrast to the case of the four-gap RPCs, we found the relatively high threshold was conducive to effectively suppressing the rapid increase of strip cluster sizes of muon hits with high voltage, especially when measuring the narrow-pitch strips. The gamma-induced currents drawn in the four-gap RPC were about one-fourth of those drawn in the double-gap RPC. The rate capabilities of both RPC types, proven through the present testing using gamma-ray sources, far exceeded the maximum rate expected in the new high-η endcap RPCs planned for future phase-II LHC runs.
△ Less
Submitted 4 May, 2016; v1 submitted 2 May, 2016;
originally announced May 2016.
-
A novel application of Fiber Bragg Grating (FBG) sensors in MPGD
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
O. Aboamer,
D. Acosta,
A. Ahmad,
W. Ahmed,
W. Ahmed,
A. Aleksandrov,
R. Aly,
P. Altieri,
C. Asawatangtrakuldee,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
V. Barashko,
P. Barria,
G. Bencze,
N. Beni,
L. Benussi
, et al. (133 additional authors not shown)
Abstract:
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active are…
▽ More
We present a novel application of Fiber Bragg Grating (FBG) sensors in the construction and characterisation of Micro Pattern Gaseous Detector (MPGD), with particular attention to the realisation of the largest triple (Gas electron Multiplier) GEM chambers so far operated, the GE1/1 chambers of the CMS experiment at LHC. The GE1/1 CMS project consists of 144 GEM chambers of about 0.5 m2 active area each, employing three GEM foils per chamber, to be installed in the forward region of the CMS endcap during the long shutdown of LHC in 2108-2019. The large active area of each GE1/1 chamber consists of GEM foils that are mechanically stretched in order to secure their flatness and the consequent uniform performance of the GE1/1 chamber across its whole active surface. So far FBGs have been used in high energy physics mainly as high precision positioning and re-positioning sensors and as low cost, easy to mount, low space consuming temperature sensors. FBGs are also commonly used for very precise strain measurements in material studies. In this work we present a novel use of FBGs as flatness and mechanical tensioning sensors applied to the wide GEM foils of the GE1/1 chambers. A network of FBG sensors have been used to determine the optimal mechanical tension applied and to characterise the mechanical tension that should be applied to the foils. We discuss the results of the test done on a full-sized GE1/1 final prototype, the studies done to fully characterise the GEM material, how this information was used to define a standard assembly procedure and possible future developments.
△ Less
Submitted 28 December, 2015;
originally announced December 2015.
-
Fiber Bragg Grating (FBG) sensors as flatness and mechanical stretching sensors
Authors:
D. Abbaneo,
M. Abbas,
M. Abbrescia,
A. A. Abdelalim,
M. Abi Akl,
O. Aboamer,
D. Acosta,
A. Ahmad,
W. Ahmed,
W. Ahmed,
A. Aleksandrov,
R. Aly,
P. Altieri,
C. Asawatangtrakuldee,
P. Aspell,
Y. Assran,
I. Awan,
S. Bally,
Y. Ban,
S. Banerjee,
V. Barashko,
P. Barria,
G. Bencze,
N. Beni,
L. Benussi
, et al. (133 additional authors not shown)
Abstract:
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.
A novel approach which uses Fibre Bragg Grating (FBG) sensors has been utilised to assess and monitor the flatness of Gaseous Electron Multipliers (GEM) foils. The setup layout and preliminary results are presented.
△ Less
Submitted 28 December, 2015;
originally announced December 2015.
-
Torrefaction of Pelletized Oil Palm Empty Fruit Bunches
Authors:
Bemgba Bevan Nyakuma,
Arshad Ahmad,
Anwar Johari,
Tuan Amran Tuan Abdullah,
Olagoke Oladokun
Abstract:
The torrefaction of oil palm Empty Fruit Bunch (EFB) briquettes was examined in this study. The results indicate that temperature significantly influenced the mass yield, energy yield and heating value of oil palm empty fruit bunch (OPEFB) briquettes during torrefaction. The solid uniform compact nature of EFB briquettes ensured a slow rate of pyrolysis or devolatization which enhanced torrefactio…
▽ More
The torrefaction of oil palm Empty Fruit Bunch (EFB) briquettes was examined in this study. The results indicate that temperature significantly influenced the mass yield, energy yield and heating value of oil palm empty fruit bunch (OPEFB) briquettes during torrefaction. The solid uniform compact nature of EFB briquettes ensured a slow rate of pyrolysis or devolatization which enhanced torrefaction. The mass yield decreased from 79.70 % to 43.03 %, energy yield from 89.44 % to 64.27 % during torrefaction from 250 °C to 300 °C. The heating value (HHV) of OPEFB briquettes improved significantly from 17.57 MJ/kg to 26.24 MJ/kg after torrefaction at 300 °C for 1 hour. Fundamentally, the study has highlighted the effects of pelletization and torrefaction on solid fuel properties of oil palm EFB briquettes and its potential as a solid fuel for future thermal applications.
△ Less
Submitted 10 May, 2015;
originally announced May 2015.
-
Performance of the gas gain monitoring system of the CMS RPC muon detector
Authors:
L. Benussi,
S. Bianco,
L. Passamonti,
D. Piccolo,
D. Pierluigi,
G. Raffone,
A. Russo,
G. Saviano,
Y. Ban,
J. Cai,
Q. Li,
S. Liu,
S. Qian,
D. Wang,
Z. Xu,
F. Zhang,
Y. Choi,
D. Kim,
S. Choi,
B. Hong,
J. W. Kang,
M. Kang,
J. H. Kwon,
K. S. Lee,
S. K. Park
, et al. (60 additional authors not shown)
Abstract:
The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.
The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.
△ Less
Submitted 27 December, 2014;
originally announced December 2014.