-
Organizations, teams, and job mobility: A social microdynamics approach
Authors:
Bryan Adams,
Valentín Vergara Hidd,
Daniel Stimpson,
Miesha Purcell,
Eduardo López
Abstract:
The internal structures of large organizations determine much of what occurs inside including the way in which tasks are performed, the workers that perform them, and the mobility of those workers within the organization. However, regarding this latter process, most of the theoretical and modeling approaches used to understand organizational worker mobility are highly stylized, using idealizations…
▽ More
The internal structures of large organizations determine much of what occurs inside including the way in which tasks are performed, the workers that perform them, and the mobility of those workers within the organization. However, regarding this latter process, most of the theoretical and modeling approaches used to understand organizational worker mobility are highly stylized, using idealizations such as structureless organizations, indistinguishable workers, and a lack of social bonding of the workers. In this article, aided by a decade of precise, temporally resolved data of a large US government organization, we introduce a new model to describe organizations as composites of teams within which individuals perform specific tasks and where social connections develop. By tracking the personnel composition of organizational teams, we find that workers that change jobs are highly influenced by preferring to reunite with past co-workers. In this organization, 34\% of all moves lead to worker reunions, a percentage well-above expectation. We find that the greater the time workers spend together or the smaller the team they share both increase their likelihood to reunite, supporting the notion of increased familiarity and trust behind such reunions and the dominant role of social capital in the evolution of large organizations.
△ Less
Submitted 31 March, 2025;
originally announced March 2025.
-
Fool's gold: ligand-receptor interactions and the origins of life
Authors:
Betony Adams,
Angela Illing,
Francesco Petruccione
Abstract:
The origins of life is a question that continues to intrigue scientists across disciplines. One theory - the iron-sulphur theory - suggests that reactions essential to the synthesis of biological materials got their catalytic 'spark' from mineral surfaces such as iron pyrite, commonly known as fool's gold. Additionally, the binding affinity of the ligands synthesised in this 'surface metabolism' a…
▽ More
The origins of life is a question that continues to intrigue scientists across disciplines. One theory - the iron-sulphur theory - suggests that reactions essential to the synthesis of biological materials got their catalytic 'spark' from mineral surfaces such as iron pyrite, commonly known as fool's gold. Additionally, the binding affinity of the ligands synthesised in this 'surface metabolism' acted as an early version of natural selection: more strongly-binding ligands were accumulated into further autocatalytic reactions and the aggregation of complex biological materials. Ligand-receptor binding is thus fundamental to the origins of life. In this paper, we use the iron-sulphur theory as a lens through which to review ligand-receptor interactions as they are more commonly understood today. In particular we focus on the electron tunnelling theory of receptor activation that has emerged from research into quantum biology. We revisit criticism against this theory, particularly the lack of evidence for electron transfer in receptors, to see what insights might be offered by ligand-receptor interactions mediated by iron pyrite at the origins of life. What emerges from this comparison is the central importance of redox activity in receptors, in particular with respect to the recurring presence of the disulphide bond. While the paper is a speculative exercise, we conclude that conductivity in biomolecules, particularly the selective conductivity conferred by appropriate ligand-receptor binding, is a powerful tool for understanding diverse phenomena such as pharmacological potency and viral infection. As such it deserves further investigation.
△ Less
Submitted 18 December, 2024;
originally announced December 2024.
-
Quantum evolution: terrestrial fine-tuning of magnetic parameters
Authors:
Betony Adams,
Abbas Hassasfar,
Ilya Sinayskiy,
Alistair Nunn,
Geoffrey Guy,
Francesco Petruccione
Abstract:
For the first time in history, humankind might conceivably begin to imagine itself as a multi-planetary species. This goal will entail technical innovation in a number of contexts, including that of healthcare. All life on Earth shares an evolution that is coupled to specific environmental conditions, including gravitational and magnetic fields. While the human body may be able to adjust to short…
▽ More
For the first time in history, humankind might conceivably begin to imagine itself as a multi-planetary species. This goal will entail technical innovation in a number of contexts, including that of healthcare. All life on Earth shares an evolution that is coupled to specific environmental conditions, including gravitational and magnetic fields. While the human body may be able to adjust to short term disruption of these fields during space flights, any long term settlement would have to take into consideration the effects that different fields will have on biological systems, within the space of one lifetime, but also across generations. Magnetic fields, for example, influence the growth of stem cells in regenerative processes. Circadian rhythms are profoundly influenced by magnetic fields, a fact that will likely have an effect on mental as well as physical health. Even the brain responds to small perturbations of this field. One possible mechanism for the effects of weak magnetic fields on biological systems has been suggested to be the radical pair mechanism. The radical pair mechanism originated in the context of spin chemistry to describe how magnetic fields influence the yields of chemical reactions. This mechanism was subsequently incorporated into the field of quantum biology. Quantum biology, most generally, is the study of whether non-trivial quantum effects play any meaningful role in biological systems. The radical pair mechanism has been used most consistently in this context to describe the avian compass. Recently, however, a number of studies have investigated other biological contexts in which the radical pair might play a role, from the action of anaesthetics and antidepressants, to microtubule development and the proper function of the circadian clock... (full abstract in the manuscript)
△ Less
Submitted 18 October, 2024;
originally announced November 2024.
-
Particle-in-cell simulations of expanding high energy density plasmas with laser ray tracing
Authors:
K. V. Lezhnin,
S. R. Totorica,
A. S. Hyder,
J. Griff-McMahon,
M. B. P. Adams,
P. Tzeferacos,
A. Diallo,
W. Fox
Abstract:
The design and analysis of high energy density (HED) laser experiments typically rely on radiation hydrodynamics simulations. However, some laser-plasma interaction regimes are not collisional and cannot be adequately modeled with hydrodynamics. For example, strongly driven magnetic reconnection and magnetized collisionless shock experiments possess extended hydrodynamic or even kinetic properties…
▽ More
The design and analysis of high energy density (HED) laser experiments typically rely on radiation hydrodynamics simulations. However, some laser-plasma interaction regimes are not collisional and cannot be adequately modeled with hydrodynamics. For example, strongly driven magnetic reconnection and magnetized collisionless shock experiments possess extended hydrodynamic or even kinetic properties, necessitating first-principles kinetic simulations. In this paper, we present the benchmarking and first results obtained with a laser-ray-tracing and inverse Bremsstrahlung absorption module implemented in the particle-in-cell code PSC. The simulation results are compared to radiation hydrodynamic simulations using the FLASH code as well as analytical estimates. We successfully benchmark the energy deposition model and overall hydrodynamic evolution of the systems. We also consider possible kinetic effects that may be expected from laser-target ablation in the HED regime, including non-local transport and two-temperature effects.
△ Less
Submitted 25 September, 2024;
originally announced September 2024.
-
Feasibility and Performance of the Staged Z-Pinch: A One-dimensional Study with FLASH and MACH2
Authors:
Edward C. Hansen,
Fernando Garcia-Rubio,
Marissa B. P. Adams,
Milad Fatenejad,
Kasper Moczulski,
Paul Ney,
Hafiz U. Rahman,
Adam C. Reyes,
Emil Ruskov,
Victor Tranchant,
Petros Tzeferacos
Abstract:
Z-pinch platforms constitute a promising pathway to fusion energy research. Here, we present a one-dimensional numerical study of the staged Z-pinch (SZP) concept using the FLASH and MACH2 codes. We discuss the verification of the codes using two analytical benchmarks that include Z-pinch-relevant physics, building confidence on the codes' ability to model such experiments. Then, FLASH is used to…
▽ More
Z-pinch platforms constitute a promising pathway to fusion energy research. Here, we present a one-dimensional numerical study of the staged Z-pinch (SZP) concept using the FLASH and MACH2 codes. We discuss the verification of the codes using two analytical benchmarks that include Z-pinch-relevant physics, building confidence on the codes' ability to model such experiments. Then, FLASH is used to simulate two different SZP configurations: a xenon gas-puff liner (SZP1*) and a silver solid liner (SZP2). The SZP2 results are compared against previously published MACH2 results, and a new code-to-code comparison on SZP1* is presented. Using an ideal equation of state and analytical transport coefficients, FLASH yields a fuel convergence ratio (CR) of approximately 39 and a mass-averaged fuel ion temperature slightly below 1 keV for the SZP2 scheme, significantly lower than the full-physics MACH2 prediction. For the new SZP1* configuration, full-physics FLASH simulations furnish large and inherently unstable CRs (> 300), but achieve fuel ion temperatures of many keV. While MACH2 also predicts high temperatures, the fuel stagnates at a smaller CR. The integrated code-to-code comparison reveals how magnetic insulation, heat conduction, and radiation transport affect platform performance and the feasibility of the SZP concept.
△ Less
Submitted 3 April, 2024; v1 submitted 13 November, 2023;
originally announced November 2023.
-
Entanglement and coherence in pure and doped Posner molecules
Authors:
Betony Adams,
Ilya Sinayskiy,
Shivang Agarwal,
Francesco Petruccione
Abstract:
The potential role of spin in biological systems is a primary topic in quantum biology. However, much of this research focuses on electron spin. A recent hypothesis suggests that nuclear spin may be better suited to biological processes, being less sensitive to decoherence. The hypothesis details how phosphorus nuclei might be prepared in a spin-entangled state, how this entanglement is protected…
▽ More
The potential role of spin in biological systems is a primary topic in quantum biology. However, much of this research focuses on electron spin. A recent hypothesis suggests that nuclear spin may be better suited to biological processes, being less sensitive to decoherence. The hypothesis details how phosphorus nuclei might be prepared in a spin-entangled state, how this entanglement is protected by assembly into calcium phosphate (Posner) molecules, and how this entanglement might modulate calcium ion production and concomitant neural activation. In this paper, we investigate the robustness of quantum effects such as coherence and entanglement in Posner molecules. We investigate how these effects are directly dependent on specific parameters such as spin-spin coupling strengths and Posner molecule symmetry. We also investigate how lithium isotope-doped Posner molecules differentially modulate quantum resources such as coherence and entanglement and whether this is a viable explanation for lithium's mechanism of action in bipolar disease. Finally, we illustrate how entanglement might possibly be preserved through the exploitation of the biological environment.
△ Less
Submitted 20 October, 2023;
originally announced October 2023.
-
Magneto-optical trap performance for high-bandwidth applications
Authors:
Benjamin Adams,
Sachin Kinge,
Kai Bongs,
Yu-Hung Lien
Abstract:
We study the dynamics of a magneto-optical trap (MOT) operating at high-bandwidth. We find the absolute importance of high recapture efficiency between cycles to maintain a practical atom number. We develop a simple model accounting for MOT trapping forces and pressure induced collisions and validate with experimental data using $\mathrm{{}^{87}Rb}$. This is then applied to quantum sensing predict…
▽ More
We study the dynamics of a magneto-optical trap (MOT) operating at high-bandwidth. We find the absolute importance of high recapture efficiency between cycles to maintain a practical atom number. We develop a simple model accounting for MOT trapping forces and pressure induced collisions and validate with experimental data using $\mathrm{{}^{87}Rb}$. This is then applied to quantum sensing predicting a shot noise limited sensitivity of $\mathrm{10^{-7}g/\sqrt{Hz}}$ for a gravimeter at 100 Hz operation. The results are useful for understanding MOT operation at high-bandwidth, particularly in the context of developing mobile high-bandwidth quantum inertial sensors targeting dynamic environments and navigation applications.
△ Less
Submitted 25 September, 2023;
originally announced September 2023.
-
Low-Dose TOF-PET Based on Surface Electron Production in Dielectric Laminar MCPs
Authors:
Kepler Domurat-Sousa,
Cameron Poe,
Henry J. Frisch,
Bernhard W. Adams,
Camden Ertley,
Neal Sullivan
Abstract:
We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects, eliminating the scintillator and photodetector sub-systems in PET scanners. In Ref. [1] we described Microchannel Plates (MCP) constructed from thin dielectric laminae…
▽ More
We present simulations of whole-body low-dose time-of-flight positron emission tomography (TOF-PET) based on the direct surface production [1] by 511 keV gamma rays of energetic electrons via the Photo-electric and Compton Effects, eliminating the scintillator and photodetector sub-systems in PET scanners. In Ref. [1] we described Microchannel Plates (MCP) constructed from thin dielectric laminae containing heavy nuclei such as lead or tungsten (LMCP$^{\rm{TM}}$). The laminae surfaces are micro-patterned to form channels, which can then be functionalized to support secondary electron emission in the manner of conventional MCPs.
We have simulated direct conversion using modifications to the TOPAS Geant4-based tool kit. A 20 $\times$ 20 $\times$ 2.54 cm$^3$ LMCP, composed of 150-micron thick lead-glass laminae, is predicted to have a $\ge 30$% conversion efficiency to a primary electron that penetrates an interior wall of a pore. The subsequent secondary electron shower is largely confined to one pore and can provide high space and time resolutions.
In whole-body PET scanners the technique eliminates the scintillator and photodetector subsystems. The consequent absence of a photocathode allows assembly of large arrays at atmospheric pressure and less stringent vacuum requirements, including use of pumped and cycled systems.
TOPAS simulations of the Derenzo and XCAT-brain phantoms are presented with dose reductions of factors of 100 and 1000 from a literature benchmark. New applications of PET at a significantly lower radiation dose include routine screening for early detection of pathologies, the use in diagnostics in previously unserved patient populations such as children, and a larger installed facility base in rural and under-served populations, where simpler gamma detectors and lower radiation doses may enable small low-cost portable PET scanners.
△ Less
Submitted 18 October, 2023; v1 submitted 5 July, 2023;
originally announced July 2023.
-
Simulation of a Compton-based detector for low-dose high-resolution time-of-flight positron emission tomography
Authors:
Kepler Domurat-Sousa,
Cameron M. Poe,
Maya S. McDaniel,
Eric Spieglan,
Joao F. Shida,
Evan Angelico,
Bernhard W. Adams,
Patrick J. La Riviere,
Henry J. Frisch,
Allison H. Squires
Abstract:
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scatte…
▽ More
Two major challenges in time-of-flight positron emission tomography (TOF-PET) are low spatial resolution and high radioactive dose to the patient, both of which result from limitations in detection technology rather than fundamental physics. A new type of TOF-PET detector employing low-atomic number (low-Z) scintillation media and large-area, high-resolution photodetectors to record Compton scattering locations in the detector has been proposed as a promising alternative, but the minimum technical requirements for such a system have not yet been established. Here we present a simulation study evaluating the potential of a proposed low-Z detection medium, linear alkylbenzene (LAB) doped with a switchable molecular recorder, for next-generation TOF-PET detection. We developed a custom Monte Carlo simulation of full-body TOF-PET using the TOPAS Geant4 software package. By quantifying contributions and tradeoffs for energy, spatial, and timing resolution of the detector, we show that at reasonable combination of specifications, our likelihood-based identification of pairs of first interaction locations in the simulated detector identifies 87.1% of pairs with zero or negligible error, and correctly rejects 90% of all in-patient scatters. The same specifications give TOF-PET sensitivity of ~66.7% and PSF width 4.6 mm with clear contrast. A detector with these specifications provides a clear image of a brain phantom simulated at less than 1% of a standard radiotracer dose.
△ Less
Submitted 3 January, 2024; v1 submitted 11 May, 2023;
originally announced May 2023.
-
Axion Dark Matter
Authors:
C. B. Adams,
N. Aggarwal,
A. Agrawal,
R. Balafendiev,
C. Bartram,
M. Baryakhtar,
H. Bekker,
P. Belov,
K. K. Berggren,
A. Berlin,
C. Boutan,
D. Bowring,
D. Budker,
A. Caldwell,
P. Carenza,
G. Carosi,
R. Cervantes,
S. S. Chakrabarty,
S. Chaudhuri,
T. Y. Chen,
S. Cheong,
A. Chou,
R. T. Co,
J. Conrad,
D. Croon
, et al. (130 additional authors not shown)
Abstract:
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synerg…
▽ More
Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.
△ Less
Submitted 29 March, 2023; v1 submitted 28 March, 2022;
originally announced March 2022.
-
Design and Performance of the Prototype Schwarzschild-Couder Telescope Camera
Authors:
Colin B. Adams,
Giovanni Ambrosi,
Michelangelo Ambrosio,
Carla Aramo,
Timothy Arlen,
Wystan Benbow,
Bruna Bertucci,
Elisabetta Bissaldi,
Jonathan Biteau,
Massimiliano Bitossi,
Alfonso Boiano,
Carmela Bonavolontà,
Richard Bose,
Aurelien Bouvier,
Mario Buscemi,
Aryeh Brill,
Anthony M. Brown,
James H. Buckley,
Rodolfo Canestrari,
Massimo Capasso,
Mirco Caprai,
Paolo Coppi,
Corbin E. Covault,
Davide Depaoli,
Leonardo Di Venere
, et al. (64 additional authors not shown)
Abstract:
The prototype Schwarzschild-Couder Telescope (pSCT) is a candidate for a medium-sized telescope in the Cherenkov Telescope Array. The pSCT is based on a novel dual mirror optics design which reduces the plate scale and allows for the use of silicon photomultipliers as photodetectors.
The prototype pSCT camera currently has only the central sector instrumented with 25 camera modules (1600 pixels)…
▽ More
The prototype Schwarzschild-Couder Telescope (pSCT) is a candidate for a medium-sized telescope in the Cherenkov Telescope Array. The pSCT is based on a novel dual mirror optics design which reduces the plate scale and allows for the use of silicon photomultipliers as photodetectors.
The prototype pSCT camera currently has only the central sector instrumented with 25 camera modules (1600 pixels), providing a 2.68$^{\circ}$ field of view (FoV). The camera electronics are based on custom TARGET (TeV array readout with GSa/s sampling and event trigger) application specific integrated circuits. Field programmable gate arrays sample incoming signals at a gigasample per second. A single backplane provides camera-wide triggers. An upgrade of the pSCT camera is in progress, which will fully populate the focal plane. This will increase the number of pixels to 11,328, the number of backplanes to 9, and the FoV to 8.04$^{\circ}$. Here we give a detailed description of the pSCT camera, including the basic concept, mechanical design, detectors, electronics, current status and first light.
△ Less
Submitted 15 March, 2022;
originally announced March 2022.
-
Bad vibrations: Quantum tunnelling in the context of SARS-CoV-2 infection
Authors:
Betony Adams,
Ilya Sinayskiy,
Rienk van Grondelle,
Francesco Petruccione
Abstract:
The SARS-CoV-2 pandemic has added new urgency to the study of viral mechanisms of infection. But while vaccines offer a measure of protection against this specific outbreak, a new era of pandemics has been predicted. In addition to this, COVID-19 has drawn attention to post-viral syndromes and the healthcare burden they entail. It seems integral that knowledge of viral mechanisms is increased thro…
▽ More
The SARS-CoV-2 pandemic has added new urgency to the study of viral mechanisms of infection. But while vaccines offer a measure of protection against this specific outbreak, a new era of pandemics has been predicted. In addition to this, COVID-19 has drawn attention to post-viral syndromes and the healthcare burden they entail. It seems integral that knowledge of viral mechanisms is increased through as wide a research field as possible. To this end we propose that quantum biology might offer essential new insights into the problem, especially with regards to the important first step of virus-host invasion. Research in quantum biology often centres around energy or charge transfer. While this is predominantly in the context of photosynthesis there has also been some suggestion that cellular receptors such as olfactory or neural receptors might employ vibration assisted electron tunnelling to augment the lock-and-key mechanism. Quantum tunnelling has also been observed in enzyme function. Enzymes are implicated in the invasion of host cells by the SARS-CoV-2 virus. Receptors such as olfactory receptors also appear to be disrupted by COVID-19. Building on these observations we investigate the evidence that quantum tunnelling might be important in the context of infection with SARS-CoV-2. We illustrate this with a simple model relating the vibronic mode of, for example, a viral spike protein to the likelihood of charge transfer in an idealised receptor. Our results show a distinct parameter regime in which the vibronic mode of the spike protein enhances electron transfer. With this in mind, novel therapeutics to prevent SARS-CoV-2 transmission could potentially be identified by their vibrational spectra.
△ Less
Submitted 17 November, 2021;
originally announced November 2021.
-
High Repetition Rate Exploration of the Biermann Battery Effect in Laser Produced Plasmas Over Large Spatial Regions
Authors:
J. J. Pilgram,
M. B. P. Adams,
C. G. Constantin,
P. V. Heuer,
S. Ghazaryan,
M. Kaloyan,
R. S. Dorst,
D. B. Schaeffer,
P. Tzeferacos,
C. Niemann
Abstract:
In this paper we present a high-repetition-rate experimental platform for examining the spatial structure and evolution of Biermann generated magnetic fields in laser-produced plasmas. We have extended the work of prior experiments, which spanned over millimeter scales, by spatially measuring magnetic fields in multiple planes on centimeter scales over thousands of laser shots. Measurements with m…
▽ More
In this paper we present a high-repetition-rate experimental platform for examining the spatial structure and evolution of Biermann generated magnetic fields in laser-produced plasmas. We have extended the work of prior experiments, which spanned over millimeter scales, by spatially measuring magnetic fields in multiple planes on centimeter scales over thousands of laser shots. Measurements with magnetic flux probes show azimuthally symmetric magnetic fields that range from 60 G at 0.7 cm from the target to 7 G at 4.2 cm from the target. The expansion rate of the magnetic fields and evolution of current density structures are also mapped and examined. Electron temperature and density of the laser-produced plasma are measured with optical Thomson scattering and used to directly calculate a magnetic Reynolds number of $1.4\times 10^4$, confirming that magnetic advection is dominant $\ge 1.5$ cm from the target surface. The results are compared to FLASH simulations, which show qualitative agreement with the data.
△ Less
Submitted 24 February, 2022; v1 submitted 4 November, 2021;
originally announced November 2021.
-
Prototype Schwarzschild-Couder Telescope for the Cherenkov Telescope Array: Commissioning the Optical System
Authors:
C. B. Adams,
G. Ambrosi,
M. Ambrosio,
C. Aramo,
P. I. Batista,
W. Benbow,
B. Bertucci,
E. Bissaldi,
M. Bitossi,
A. Boiano,
C. Bonavolontà,
R. Bose,
A. Brill,
J. H. Buckley,
R. A. Cameron,
R. Canestrari,
M. Capasso,
M. Caprai,
C. E. Covault,
D. Depaoli,
L. Di Venere,
M. Errando,
S. Fegan,
Q. Feng,
E. Fiandrini
, et al. (47 additional authors not shown)
Abstract:
A prototype Schwarzschild-Couder Telescope (pSCT) has been constructed at the Fred Lawrence Whipple Observatory as a candidate for the medium-sized telescopes of the Cherenkov Telescope Array Observatory (CTAO). CTAO is currently entering early construction phase of the project and once completed it will vastly improve very high energy gamma-ray detection component in multi-wavelength and multi-me…
▽ More
A prototype Schwarzschild-Couder Telescope (pSCT) has been constructed at the Fred Lawrence Whipple Observatory as a candidate for the medium-sized telescopes of the Cherenkov Telescope Array Observatory (CTAO). CTAO is currently entering early construction phase of the project and once completed it will vastly improve very high energy gamma-ray detection component in multi-wavelength and multi-messenger observations due to significantly improved sensitivity, angular resolution and field of view comparing to the current generation of the ground-based gamma-ray observatories H.E.S.S., MAGIC and VERITAS. The pSCT uses a dual aspheric mirror design with a $9.7$ m primary mirror and $5.4$ m secondary mirror, both of which are segmented. The Schwarzschild-Couder (SC) optical system (OS) selected for the prototype telescope achieves wide field of view of $8$ degrees and simultaneously reduces the focal plane plate scale allowing an unprecedented compact ($0.78$m diameter) implementation of the high-resolution camera ($6$mm/ $0.067$deg per imaging pixel with $11,328$ pixels) based on the silicon photo-multipliers (SiPMs). The OS of the telescope is designed to eliminate spherical and comatic aberrations and minimize astigmatism to radically improve off-axis imaging and consequently angular resolution across all the field of view with respect to the conventional single-mirror telescopes. Fast and high imaging resolution OS of the pSCT comes with the challenging submillimeter-precision custom alignment system, which was successfully demonstrated with an on-axis point spread function (PSF) of $2.9$ arcmin prior to the first-light detection of the Crab Nebula in 2020. Ongoing and future commissioning activities are reported.
△ Less
Submitted 14 October, 2021;
originally announced October 2021.
-
Low-Dose High-Resolution TOF-PET Using Ionization-activated Multi-State Low-Z Detector Media
Authors:
Joao Francisco Shida,
Eric Spieglan,
Bernhard W. Adams,
Evan Angelico,
Kepler Domurat-Sousa,
Andrey Elagin,
Henry J. Frisch,
Patrick La Riviere,
Allison H. Squires
Abstract:
We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatter…
▽ More
We propose PET scanners using low atomic number media that undergo a persistent local change of state along the paths of the Compton recoil electrons. Measurement of the individual scattering locations and angles, deposited energies, and recoil electron directions allows using the kinematical constraints of the 2-body Compton scattering process to perform a statistical time-ordering of the scatterings, with a high probability of precisely identifying where the gamma first interacted in the detector. In these cases the Line-of-Response is measured with high resolution, determined by the underlying physics processes and not the detector segmentation. There are multiple such media that act through different mechanisms. As an example in which the change of state is quantum-mechanical through a change in molecular configuration, rather than thermodynamic, as in a bubble chamber, we present simulations of a two-state photoswitchable organic dye, a `Switchillator', that is activated to a fluorescent-capable state by the ionization of the recoil electrons. The activated state is persistent, and can be optically excited multiple times to image individual activated molecules. Energy resolution is provided by counting the activated molecules. Location along the LOR is implemented by large-area time-of-flight MCP-PMT photodetectors with single photon time resolution in the tens of ps and sub-mm spatial resolution. Simulations indicate a large reduction of dose.
△ Less
Submitted 3 August, 2021;
originally announced August 2021.
-
Air-Transfer Production Method for Large-Area Picosecond Photodetectors
Authors:
E. Angelico,
A. Elagin,
H. J. Frisch,
E. Spieglan,
B. W. Adams,
M. R. Foley,
M. J. Minot
Abstract:
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside th…
▽ More
We have designed and prototyped the process steps for the batch production of large-area micro-channel-plate photomultipliers (MCP-PMT) using the "air-transfer" assembly process developed with single $LAPPD^{\text{TM}}$ modules. Results are presented addressing the challenges of designing a robust package that can transmit large numbers of electrical signals for pad or strip readout from inside the vacuum tube and hermetically sealing the large-perimeter window-body interface. We have also synthesized a photocathode in a large-area low-aspect-ratio volume, and shown that the micro-channel plates recover their functionality after cathode synthesis. The steps inform a design for a multi-module batch facility employing dual nested low-vacuum (LV) and ultra-high-vacuum (UHV) systems in a small-footprint. The facility design provides full access to multiple MCP-PMT modules prior to hermetic pinch-off for leak-checking and real-time photocathode optimization.
△ Less
Submitted 13 March, 2020;
originally announced March 2020.
-
Differences in the response of two light guide technologies and two readout technologies after an exchange of liquid argon in the dewar
Authors:
S. Mufson,
B. Adams,
B. Baugh,
B. Howard,
C. Macias,
G. Cancelo,
E. Niner,
D. Totani
Abstract:
In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar wa…
▽ More
In this investigation the response to the scintillation light generated by through-going cosmic muons in liquid argon (LAr) was measured by two light guide technologies and two readout technologies after five weeks of running in the TallBo dewar at Fermilab. The response was remeasured after the dewar was drained of LAr, refilled, and then run again for an additional four weeks. After the dewar was refilled, there was clear evidence that the scintillation signal had dropped significantly. The two light guide technologies were developed at Indiana University and MIT/Fermilab. The two readout technologies were boards that passively or actively ganged 12 Hamamatsu MPPCs. Two possible explanations were identified for the degraded signal: the response of the two light guide technologies degraded due to damage caused by thermal cycling, and/or unknown differences in the trace residual Xe contamination in the fills of LAr led to the observed drop in scintillation light. Neither absorption nor quenching by N2, O2, and H2O contamination can account for the degradation. Neither the individual Hamamatsu MPPCs nor the passive/active ganging boards appear to have been affected by the thermal cycling. The path length distributions of the cosmics traversing the dewar appear quite similar in both event samples.
△ Less
Submitted 17 June, 2020; v1 submitted 12 December, 2019;
originally announced December 2019.
-
Performance of Large Area Picosecond Photo-Detectors (LAPPD)
Authors:
A. V. Lyashenko,
B. W. Adams,
M. Aviles,
T. Cremer,
C. D. Ertley,
M. R. Foley,
M. J. Minot,
M. A. Popecki,
M. E. Stochaj,
W. A. Worstell,
J. W. Elam,
A. U. Mane,
O. H. W. Siegmund,
H. J. Frisch,
A. L. Elagin,
E. Angelico,
E. Spieglan
Abstract:
We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single ph…
▽ More
We report on performance results achieved for recently produced LAPPDs - largest comercially available planar geometry photodetectors based on microchannel plates. These results include electron gains of up to $10^{7}$, low dark noise rates ($\sim$100 Hz/cm$^{2}$ at a gain of $6\cdot10^6$), single photoelectron (PE) timing resolution of $\sim$50 picoseconds RMS (electronics limited), and single photoelectron spatial resolution along and across strips of 3.2mm (electronics limited) and 0.8 mm RMS respectively and high (about 25\% or higher in some units) QE uniform bi-alkali photocathodes. LAPPDs is a good candidate to be employed in neutrino experiments (e.g. ANNIE, WATCHMAN, DUNE), particle collider experiments (e.g. EIC), neutrinoless double-beta decay experiments (e.g. THEIA), medical and nuclear non-proliferation applications.
△ Less
Submitted 23 September, 2019;
originally announced September 2019.
-
Scientific Opportunities with an X-ray Free-Electron Laser Oscillator
Authors:
Bernhard Adams,
Gabriel Aeppli,
Thomas Allison,
Alfred Q. R. Baron,
Phillip Bucksbaum,
Aleksandr I. Chumakov,
Christopher Corder,
Stephen P. Cramer,
Serena DeBeer,
Yuntao Ding,
Jörg Evers,
Josef Frisch,
Matthias Fuchs,
Gerhard Grübel,
Jerome B. Hastings,
Christoph M. Heyl,
Leo Holberg,
Zhirong Huang,
Tetsuya Ishikawa,
Andreas Kaldun,
Kwang-Je Kim,
Tomasz Kolodziej,
Jacek Krzywinski,
Zheng Li,
Wen-Te Liao
, et al. (25 additional authors not shown)
Abstract:
An X-ray free-electron laser oscillator (XFELO) is a new type of hard X-ray source that would produce fully coherent pulses with meV bandwidth and stable intensity. The XFELO complements existing sources based on self-amplified spontaneous emission (SASE) from high-gain X-ray free-electron lasers (XFEL) that produce ultra-short pulses with broad-band chaotic spectra. This report is based on discus…
▽ More
An X-ray free-electron laser oscillator (XFELO) is a new type of hard X-ray source that would produce fully coherent pulses with meV bandwidth and stable intensity. The XFELO complements existing sources based on self-amplified spontaneous emission (SASE) from high-gain X-ray free-electron lasers (XFEL) that produce ultra-short pulses with broad-band chaotic spectra. This report is based on discussions of scientific opportunities enabled by an XFELO during a workshop held at SLAC on June 29 - July 1, 2016
△ Less
Submitted 25 March, 2019; v1 submitted 18 March, 2019;
originally announced March 2019.
-
Letter of Intent: A New QCD facility at the M2 beam line of the CERN SPS (COMPASS++/AMBER)
Authors:
B. Adams,
C. A. Aidala,
R. Akhunzyanov,
G. D. Alexeev,
M. G. Alexeev,
A. Amoroso,
V. Andrieux,
N. V. Anfimov,
V. Anosov,
A. Antoshkin,
K. Augsten,
W. Augustyniak,
C. D. R. Azevedo,
A. Azhibekov,
B. Badelek,
F. Balestra,
M. Ball,
J. Barth,
R. Beck,
Y. Bedfer,
J. Berenguer Antequera,
J. C. Bernauer,
J. Bernhard,
M. Bodlak,
P. Bordalo
, et al. (242 additional authors not shown)
Abstract:
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
A New QCD facility at the M2 beam line of the CERN SPS
COMPASS++/AMBER
△ Less
Submitted 25 January, 2019; v1 submitted 2 August, 2018;
originally announced August 2018.
-
Multiple-photon disambiguation on stripline-anode Micro-Channel Plates
Authors:
Glenn R. Jocher,
Matthew J. Wetstein,
Bernhard Adams,
Kurtis Nishimura,
Shawn M. Usman
Abstract:
Large-Area Picosecond Photo-Detectors (LAPPDs) show great potential for expanding the performance envelope of Micro-Channel Plates (MCPs) to areas of up to 20 x 20 cm and larger. Such scaling introduces new challenges, including how to meet the electronics readout burden of ever larger area MCPs. One solution is to replace the traditional grid anode used for readout with a microwave stripline anod…
▽ More
Large-Area Picosecond Photo-Detectors (LAPPDs) show great potential for expanding the performance envelope of Micro-Channel Plates (MCPs) to areas of up to 20 x 20 cm and larger. Such scaling introduces new challenges, including how to meet the electronics readout burden of ever larger area MCPs. One solution is to replace the traditional grid anode used for readout with a microwave stripline anode, thus allowing the channel count to scale with MCP width rather than area. However, stripline anodes introduce new issues not commonly dealt with in grid-anodes, especially as their length increases. One of these issues is the near simultaneous arrival of multiple photons on the detector, creating possible confusion about how to reconstruct their arrival times and positions. We propose a maximum a posteriori solution to the problem and verify its performance in simulated scintillator and water-Cherenkov detectors.
△ Less
Submitted 2 May, 2018;
originally announced May 2018.
-
A Novel Use of Light Guides and Wavelength Shifting Plates for the Detection of Scintillation Photons in Large Liquid Argon Detectors
Authors:
B. Howard,
S. Mufson,
D. Whittington,
B. Adams,
B. Baugh,
J. R. Jordan,
J. Karty,
C. T. Macias,
A. Pla-Dalmau
Abstract:
Scintillation light generated as charged particles traverse large liquid argon detectors adds valuable information to studies of weakly-interacting particles. This paper uses both laboratory measurements and cosmic ray data from the Blanche dewar facility at Fermilab to characterize the efficiency of the photon detector technology developed at Indiana University for the single phase far detector o…
▽ More
Scintillation light generated as charged particles traverse large liquid argon detectors adds valuable information to studies of weakly-interacting particles. This paper uses both laboratory measurements and cosmic ray data from the Blanche dewar facility at Fermilab to characterize the efficiency of the photon detector technology developed at Indiana University for the single phase far detector of DUNE. The efficiency of this technology was found to be 0.48% at the readout end when the detector components were characterized with laboratory measurements. A second determination of the efficiency using cosmic ray tracks is in reasonable agreement with the laboratory determination. The agreement of these two efficiency determinations supports the result that minimum ionizing muons generate ${\mathcal N}_{phot} = 40,000$ photons/MeV as they cross the LAr volume.
△ Less
Submitted 3 July, 2018; v1 submitted 30 October, 2017;
originally announced October 2017.
-
Capacitively coupled pickup in MCP-based photodetectors using a conductive metallic anode
Authors:
Evan Angelico,
Todd Seiss,
Bernhard Adams,
Andrey Elagin,
Henry Frisch,
Eric Spieglan
Abstract:
We have designed and tested a robust 20 $\times$ 20 cm$^2$ thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10nm-thick NiCr film deposited on a 96% pure Al$_2$O$_3$ 3mm-thick ceramic plate and connected to HV ground, provides the return path for the electron…
▽ More
We have designed and tested a robust 20 $\times$ 20 cm$^2$ thin metal film internal anode capacitively coupled to an external array of signal pads or micro-strips for use in fast microchannel plate photodetectors. The internal anode, in this case a 10nm-thick NiCr film deposited on a 96% pure Al$_2$O$_3$ 3mm-thick ceramic plate and connected to HV ground, provides the return path for the electron cascade charge. The multi-channel pickup array consists of a printed-circuit card or glass plate with metal signal pickups on one side and the signal ground plane on the other. The pickup can be put in close proximity to the bottom outer surface of the sealed photodetector, with no electrical connections through the photodetector hermetic vacuum package other than a single ground connection to the internal anode. Two pickup patterns were tested using a small commercial MCP-PMT as the signal source: 1) parallel 50$Ω$ 25-cm-long micro-strips with an analog bandwidth of 1.5 GHz, and 2) a 20 $\times$ 20 cm$^2$ array of 2-dimensional square `pads' with sides of 1.27 cm or 2.54 cm. The rise-time of the fast input pulse is maintained for both pickup patterns. For the pad pattern, we observe 80% of the directly coupled amplitude. For the strip pattern we measure 34% of the directly coupled amplitude on the central strip of a broadened signal. The physical decoupling of the photodetector from the pickup pattern allows easy customization for different applications while maintaining high analog bandwidth.
△ Less
Submitted 5 October, 2016;
originally announced October 2016.
-
A Brief Technical History of the Large-Area Picosecond Photodetector (LAPPD) Collaboration
Authors:
Bernhard W. Adams,
Klaus Attenkofer,
Mircea Bogdan,
Karen Byrum,
Andrey Elagin,
Jeffrey W. Elam,
Henry J. Frisch,
Jean-Francois Genat,
Herve Grabas,
Joseph Gregar,
Elaine Hahn,
Mary Heintz,
Zinetula Insepov,
Valentin Ivanov,
Sharon Jelinsky,
Slade Jokely,
Sun Wu Lee,
Anil. U. Mane,
Jason McPhate,
Michael J. Minot,
Pavel Murat,
Kurtis Nishimura,
Richard Northrop,
Razib Obaid,
Eric Oberla
, et al. (16 additional authors not shown)
Abstract:
The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$,…
▽ More
The Large Area Picosecond PhotoDetector (LAPPD) Collaboration was formed in 2009 to develop large-area photodetectors capable of time resolutions measured in pico-seconds, with accompanying sub-millimeter spatial resolution. During the next three and one-half years the Collaboration developed the LAPPD design of 20 x 20 cm modules with gains greater than $10^7$ and non-uniformity less than $15\%$, time resolution less than 50 psec for single photons and spatial resolution of 700~microns in both lateral dimensions. We describe the R\&D performed to develop large-area micro-channel plate glass substrates, resistive and secondary-emitting coatings, large-area bialkali photocathodes, and RF-capable hermetic packaging. In addition, the Collaboration developed the necessary electronics for large systems capable of precise timing, built up from a custom low-power 15-GigaSample/sec waveform sampling 6-channel integrated circuit and supported by a two-level modular data acquisition system based on Field-Programmable Gate Arrays for local control, data-sparcification, and triggering. We discuss the formation, organization, and technical successes and short-comings of the Collaboration. The Collaboration ended in December 2012 with a transition from R\&D to commercialization.
△ Less
Submitted 6 March, 2016;
originally announced March 2016.
-
Precise Orbital Tracking of an Asteroid with a Phased Array of Radio Transponders
Authors:
Bernhard W. Adams
Abstract:
Deflecting an asteroid from an Earth impact trajectory requires only small velocity changes, typically of the order of microns per second, if done many years ahead of time. For this, a highly precise method of determining the need, magnitude, and direction of a deflection is required. Although the required precision can be achieved by much less accurate extended observations, an intrinsic resolu…
▽ More
Deflecting an asteroid from an Earth impact trajectory requires only small velocity changes, typically of the order of microns per second, if done many years ahead of time. For this, a highly precise method of determining the need, magnitude, and direction of a deflection is required. Although the required precision can be achieved by much less accurate extended observations, an intrinsic resolution of $μ$m/s permits the live monitoring of nongravitational orbital perturbations (Yarkovsky effect), and of a deflection effort itself. Here, it is proposed to deploy on the asteroid's surface multiple radio units to form a phased array capable of measuring radial velocities relative to Earth to about 1 $μ$m/s and ranges to 5 m. The same technology can also be used for scientific applications such as very-long baseline radio astronomy, milli-Hertz gravitational wave detection, or mapping of the solar wind.
△ Less
Submitted 15 September, 2008;
originally announced September 2008.