Universal and dynamic ridge filter for pencil beam scanning particle therapy: novel concept for ultra-fast treatment delivery
Authors:
Vivek Maradia,
Isabella Colizzi,
David Meer,
Damien Charles Weber,
Antony John Lomax,
Oxana Actis,
Serena Psoroulas
Abstract:
Purpose In PBS particle therapy, short treatment delivery time is paramount for the efficient treatment of moving targets with motion mitigation techniques (such as breath-hold, rescanning, and gating). Energy and spot position change time are limiting factors in reducing treatment time. In this study, we designed a universal and dynamic energy modulator (ridge filter, RF) to broaden the Bragg pea…
▽ More
Purpose In PBS particle therapy, short treatment delivery time is paramount for the efficient treatment of moving targets with motion mitigation techniques (such as breath-hold, rescanning, and gating). Energy and spot position change time are limiting factors in reducing treatment time. In this study, we designed a universal and dynamic energy modulator (ridge filter, RF) to broaden the Bragg peak, to reduce the number of energies and spots required to cover the target volume, thus lowering the treatment time. Methods Our RF unit comprises two identical RFs placed just before the isocenter. Both RFs move relative to each other, changing the Bragg peaks characteristics dynamically. We simulated different Bragg peak shapes with the RF in TOPAS and validated them experimentally. We then delivered single-field plans with 1Gy/fraction to different geometrical targets in water, to measure the dose delivery time using the RF and compare it with the clinical settings. Results Aligning the RFs in different positions produces different broadening in the Bragg peak; we achieved a maximum broadening of 2 cm. With RF we reduced the number of energies in a field by more than 60%, and the dose delivery time by 50%, for all geometrical targets investigated, without compromising the dose distribution transverse and distal fall-off. Conclusions Our novel universal and dynamic RF allows for the adaptation of the Bragg peak broadening for a spot and/or energy layer based on the requirement of dose shaping in the target volume. It significantly reduces the number of energy layers and spots to cover the target volume, and thus the treatment time. This RF design is ideal for ultra-fast treatment delivery within a single breath-hold (5-10 sec), efficient delivery of motion mitigation techniques, and small animal irradiation with ultra-high dose rates (FLASH).
△ Less
Submitted 13 August, 2022;
originally announced August 2022.
-
Precise On-line Position Measurement for Particle Therapy
Authors:
O. Actis,
D. Meer,
S. König
Abstract:
An on-line beam position monitoring and regular beam stability tests are of utmost importance for the Quality Assurance (QA) of the patient treatment at any particle therapy facility. The Gantry$\hspace{0.5 mm}2$ at the Paul Scherrer Institute uses a strip ionization chamber for the on-line beam position verification. The design of the strip chamber placed in the beam in front of the patient allow…
▽ More
An on-line beam position monitoring and regular beam stability tests are of utmost importance for the Quality Assurance (QA) of the patient treatment at any particle therapy facility. The Gantry$\hspace{0.5 mm}2$ at the Paul Scherrer Institute uses a strip ionization chamber for the on-line beam position verification. The design of the strip chamber placed in the beam in front of the patient allows for a small beam penumbra in order to achieve a high-quality lateral beam delivery. The position error of 1 mm in a lateral plane (plane perpendicular to the beam direction) can result in a dose inhomogeneity of more than $5 \%$. Therefore the goal of Gantry 2 commissioning was to reach a sub-millimeter level of the reconstruction accuracy in order to bring a dose uncertainty to a level of $1 \%$. In fact, we observed that for beams offered by Gantry 2 signal profiles in a lateral plane can be reconstructed with a precision of 0.1 mm. This is a necessary criterion to perform a reliable patient treatment. The front end electronics and the whole data processing sequence have been optimized for minimizing the dead time in between two consecutive spots to about 2 ms: the charge collection is performed in about 1 ms, read-out takes place in about 100 $μ$s while data verification and logging are completed in less than 1 ms.
△ Less
Submitted 6 January, 2015; v1 submitted 1 October, 2014;
originally announced October 2014.
-
Visual Physics Analysis (VISPA) - Concepts and First Applications
Authors:
O. Actis,
M. Erdmann,
R. Fischer,
A. Hinzmann,
M. Kirsch,
T. Klimkovich,
G. Müller,
M. Plum,
J. Steggemann
Abstract:
VISPA is a novel development environment for high energy physics analyses, based on a combination of graphical and textual steering. The primary aim of VISPA is to support physicists in prototyping, performing, and verifying a data analysis of any complexity. We present example screenshots, and describe the underlying software concepts.
VISPA is a novel development environment for high energy physics analyses, based on a combination of graphical and textual steering. The primary aim of VISPA is to support physicists in prototyping, performing, and verifying a data analysis of any complexity. We present example screenshots, and describe the underlying software concepts.
△ Less
Submitted 20 October, 2008;
originally announced October 2008.
-
Automated Reconstruction of Particle Cascades in High Energy Physics Experiments
Authors:
O. Actis,
M. Erdmann,
A. Henrichs,
A. Hinzmann,
M. Kirsch,
G. Müller,
J. Steggemann
Abstract:
We present a procedure for reconstructing particle cascades from event data measured in a high energy physics experiment. For evaluating the hypothesis of a specific physics process causing the observed data, all possible reconstruction versions of the scattering process are constructed from the final state objects. We describe the procedure as well as examples of physics processes of different…
▽ More
We present a procedure for reconstructing particle cascades from event data measured in a high energy physics experiment. For evaluating the hypothesis of a specific physics process causing the observed data, all possible reconstruction versions of the scattering process are constructed from the final state objects. We describe the procedure as well as examples of physics processes of different complexity studied at hadron-hadron colliders. We estimate the performance by 20 microseconds per reconstructed decay vertex, and 0.6 kByte per reconstructed particle in the decay trees.
△ Less
Submitted 8 September, 2008; v1 submitted 8 January, 2008;
originally announced January 2008.