-
Guidelines for developing optical clocks with $10^{-18}$ fractional frequency uncertainty
Authors:
Moustafa Abdel-Hafiz,
Piotr Ablewski,
Ali Al-Masoudi,
Héctor Álvarez Martínez,
Petr Balling,
Geoffrey Barwood,
Erik Benkler,
Marcin Bober,
Mateusz Borkowski,
William Bowden,
Roman Ciuryło,
Hubert Cybulski,
Alexandre Didier,
Miroslav Doležal,
Sören Dörscher,
Stephan Falke,
Rachel M. Godun,
Ramiz Hamid,
Ian R. Hill,
Richard Hobson,
Nils Huntemann,
Yann Le Coq,
Rodolphe Le Targat,
Thomas Legero,
Thomas Lindvall
, et al. (20 additional authors not shown)
Abstract:
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency…
▽ More
There has been tremendous progress in the performance of optical frequency standards since the first proposals to carry out precision spectroscopy on trapped, single ions in the 1970s. The estimated fractional frequency uncertainty of today's leading optical standards is currently in the $10^{-18}$ range, approximately two orders of magnitude better than that of the best caesium primary frequency standards. This exceptional accuracy and stability is resulting in a growing number of research groups developing optical clocks. While good review papers covering the topic already exist, more practical guidelines are needed as a complement. The purpose of this document is therefore to provide technical guidance for researchers starting in the field of optical clocks. The target audience includes national metrology institutes (NMIs) wanting to set up optical clocks (or subsystems thereof) and PhD students and postdocs entering the field. Another potential audience is academic groups with experience in atomic physics and atom or ion trapping, but with less experience of time and frequency metrology and optical clock requirements. These guidelines have arisen from the scope of the EMPIR project "Optical clocks with $1 \times 10^{-18}$ uncertainty" (OC18). Therefore, the examples are from European laboratories even though similar work is carried out all over the world. The goal of OC18 was to push the development of optical clocks by improving each of the necessary subsystems: ultrastable lasers, neutral-atom and single-ion traps, and interrogation techniques. This document shares the knowledge acquired by the OC18 project consortium and gives practical guidance on each of these aspects.
△ Less
Submitted 13 August, 2019; v1 submitted 27 June, 2019;
originally announced June 2019.
-
First observation with global network of optical atomic clocks aimed for a dark matter detection
Authors:
P. Wcisło,
P. Ablewski,
K. Beloy,
S. Bilicki,
M. Bober,
R. Brown,
R. Fasano,
R. Ciuryło,
H. Hachisu,
T. Ido,
J. Lodewyck,
A. Ludlow,
W. McGrew,
P. Morzyński,
D. Nicolodi,
M. Schioppo,
M. Sekido,
R. Le Targat,
P. Wolf,
X. Zhang,
B. Zjawin,
M. Zawada
Abstract:
We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comp…
▽ More
We report on the first earth-scale quantum sensor network based on optical atomic clocks aimed at dark matter (DM) detection. Exploiting differences in the susceptibilities to the fine-structure constant of essential parts of an optical atomic clock, i.e. the cold atoms and the optical reference cavity, we can perform sensitive searches for dark matter signatures without the need of real-time comparisons of the clocks. We report a two orders of magnitude improvement in constraints on transient variations of the fine-structure constant, which considerably improves the detection limit for the standard model (SM) - DM coupling. We use Yb and Sr optical atomic clocks at four laboratories on three continents to search for both topological defect (TD) and massive scalar field candidates. No signal consistent with a dark-matter coupling is identified, leading to significantly improved constraints on the DM-SM couplings.
△ Less
Submitted 12 June, 2018;
originally announced June 2018.
-
Absolute frequency determination of molecular transition in the Doppler regime at kHz level of accuracy
Authors:
K. Bielska,
S. Wojtewicz,
P. Morzynski,
P. Ablewski,
A. Cygan,
M. Bober,
M. Zawada,
R. Ciurylo,
P. Maslowski,
D. Lisak
Abstract:
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an…
▽ More
We present absolute frequency measurement of the unperturbed P7 P7 O$_2$ B-band transition with relative standard uncertainty of $2\times10^{-11}$. We reached the level of accuracy typical for Doppler-free techniques, with Doppler-limited spectroscopy. The Doppler-limited shapes of the P7 P7 spectral line were measured with a frequency-stabilized cavity ring-down spectrometer referenced to an $^{88}$Sr optical atomic clock by an optical frequency comb.
△ Less
Submitted 16 August, 2017; v1 submitted 18 May, 2017;
originally announced May 2017.
-
Fibre-optic delivery of time and frequency to VLBI station
Authors:
P. Krehlik,
Ł. Buczek,
J. Kołodziej,
M. Lipiński,
Ł. Śliwczyński,
J. Nawrocki,
P. Nogaś,
A. Marecki,
E. Pazderski,
P. Ablewski,
M. Bober,
R. Ciuryło,
A. Cygan,
D. Lisak,
P. Masłowski,
P. Morzyński,
M. Zawada,
R. M. Campbell,
J. Pieczerak,
A. Binczewski,
K. Turza
Abstract:
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabi…
▽ More
The quality of Very Long Baseline Interferometry (VLBI) radio observations predominantly relies on precise and ultra-stable time and frequency (T&F) standards, usually hydrogen masers (HM), maintained locally at each VLBI station. Here, we present an operational solution in which the VLBI observations are routinely carried out without use of a local HM, but using remote synchronization via a stabilized, long-distance fibre-optic link. The T&F reference signals, traceable to international atomic timescale (TAI), are delivered to the VLBI station from a dedicated timekeeping laboratory. Moreover, we describe a proof-of-concept experiment where the VLBI station is synchronized to a remote strontium optical lattice clock during the observation.
△ Less
Submitted 7 July, 2017; v1 submitted 28 March, 2017;
originally announced March 2017.
-
Strontium optical lattice clocks for practical realization of the metre and secondary representation of the second
Authors:
M. Bober,
P. Morzyński,
A. Cygan,
D. Lisak,
P. Masłowski,
M. Prymaczek,
P. Wcisło,
P. Ablewski,
M. Piwiński,
S. Wójtewicz,
K. Bielska,
D. Bartoszek-Bober,
R. Trawiński,
M. Zawada,
R. Ciuryło,
J. Zachorowski,
M. Piotrowski,
W. Gawlik,
F. Ozimek,
C. Radzewicz
Abstract:
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice…
▽ More
We present a system of two independent strontium optical lattice standards probed with a single shared ultra-narrow laser. The absolute frequency of the clocks can be verified by the use of Er:fiber optical frequency comb with the GPS-disciplined Rb frequency standard. We report hertz-level spectroscopy of the clock line and measurements of frequency stability of the two strontium optical lattice clocks.
△ Less
Submitted 15 June, 2015;
originally announced June 2015.
-
Absolute Frequency Measurement of Rubidium 5S-7S Two-Photon Transitions
Authors:
Piotr Morzynski,
Piotr Wcislo,
Piotr Ablewski,
Rafal Gartman,
Wojciech Gawlik,
Piotr Maslowski,
Bartlomiej Nagorny,
Filip Ozimek,
Czeslaw Radzewicz,
Marcin Witkowski,
Roman Ciurylo,
Michal Zawada
Abstract:
We report the absolute frequency measurements of rubidium 5S-7S two-photon transitions with a cw laser digitally locked to an atomic transition and referenced to an optical frequency comb. The narrow, two-photon transition, 5S-7S (760 nm) insensitive to first order in a magnetic field, is a promising candidate for frequency reference. The performed tests yield the transition frequency with accurac…
▽ More
We report the absolute frequency measurements of rubidium 5S-7S two-photon transitions with a cw laser digitally locked to an atomic transition and referenced to an optical frequency comb. The narrow, two-photon transition, 5S-7S (760 nm) insensitive to first order in a magnetic field, is a promising candidate for frequency reference. The performed tests yield the transition frequency with accuracy better than reported previously.
△ Less
Submitted 14 November, 2013;
originally announced November 2013.