Characterization and performance of the DTAS detector
Authors:
V. Guadilla,
J. L. Tain,
A. Algora,
J. Agramunt,
J. Äystö,
J. A. Briz,
A. Cucoanes,
T. Eronen,
M. Estienne,
M. Fallot,
L. M. Fraile,
E. Ganioğlu,
W. Gelletly,
D. Gorelov,
J. Hakala,
A. Jokinen,
D. Jordan,
A. Kankainen,
V. Kolhinen,
J. Koponen,
M. Lebois,
L. Le Meur,
T. Martinez,
M. Monserrate,
A. Montaner-Pizá
, et al. (20 additional authors not shown)
Abstract:
DTAS is a segmented total absorption γ-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which…
▽ More
DTAS is a segmented total absorption γ-ray spectrometer developed for the DESPEC experiment at FAIR. It is composed of up to eighteen NaI(Tl) crystals. In this work we study the performance of this detector with laboratory sources and also under real experimental conditions. We present a procedure to reconstruct offline the sum of the energy deposited in all the crystals of the spectrometer, which is complicated by the effect of NaI(Tl) light-yield non-proportionality. The use of a system to correct for time variations of the gain in individual detector modules, based on a light pulse generator, is demonstrated. We describe also an event-based method to evaluate the summing-pileup electronic distortion in segmented spectrometers. All of this allows a careful characterization of the detector with Monte Carlo simulations that is needed to calculate the response function for the analysis of total absorption γ-ray spectroscopy data. Special attention was paid to the interaction of neutrons with the spectrometer, since they are a source of contamination in studies of \b{eta}-delayed neutron emitting nuclei.
△ Less
Submitted 1 June, 2018;
originally announced June 2018.
-
Twin GEM-TPC Prototype (HGB4) Beam Test at GSI and Jyväskylä - a Development for the Super-FRS at FAIR
Authors:
F. García,
R. Turpeinen,
J. Äystö,
T. Grahn,
S. Rinta-Antila,
A. Jokinen,
J. Kunkel,
V. Kleipa,
A. Gromliuk,
H. Risch,
C. Caesar,
C. Simons,
C. J. Schmidt,
A. Prochazka,
J. Hoffmann,
I. Rusanov,
N. Kurz,
H. Heggen,
P. Strmen,
M. Pikna,
B. Sitar
Abstract:
The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS[2] separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will d…
▽ More
The FAIR[1] facility is an international accelerator centre for research with ion and antiproton beams. It is being built at Darmstadt, Germany as an extension to the current GSI research institute. One major part of the facility will be the Super-FRS[2] separator, which will be include in phase one of the project construction. The NUSTAR experiments will benefit from the Super-FRS, which will deliver an unprecedented range of radioactive ion beams (RIB). These experiments will use beams of different energies and characteristics in three different branches; the high-energy which utilizes the RIB at relativistic energies 300-1500 MeV/u as created in the production process, the low-energy branch aims to use beams in the range of 0-150 MeV/u whereas the ring branch will cool and store beams in the NESR ring. The main tasks for the Super-FRS beam diagnostics chambers will be for the set up and adjustment of the separator as well as to provide tracking and event-by-event particle identification. The Helsinki Institute of Physics, and the Detector Laboratory and Experimental Electronics at GSI are in a joint R&D of a GEM-TPC detector which could satisfy the requirements of such tracking detectors, in terms of tracking efficiency, space resolution, count rate capability and momenta resolution. The current prototype, which is the generation four of this type, is two GEM-TPCs in twin configuration inside the same vessel. This means that one of the GEM-TPC is flipped on the middle plane w.r.t. the other one. This chamber was tested at Jyväskylä accelerator with protons projectiles and at GSI with Uranium, fragments and Carbon beams during this year 2016.
△ Less
Submitted 22 November, 2017;
originally announced November 2017.
-
Twin GEM-TPC Prototype (HGB4) Beam Test at GSI - a Development for the Super-FRS at FAIR
Authors:
F. Garcia,
R. Turpeinen,
R. Lauhakangas,
E. Tuominen,
J. Heino,
J. Äystö,
T. Grahn,
S. Rinta-Antilla,
A. Jokinen,
R. Janik,
P. Strmen,
M. Pikna,
B. Sitar,
B. Voss,
J. Kunkel,
V. Kleipa,
A. Gromliuk,
H. Risch,
I. Kaufeld,
C. Caesar,
C. Simon,
M. kìs,
A. Prochazka,
C. Nociforo,
S. Pietri
, et al. (8 additional authors not shown)
Abstract:
The GEM-TPC detector will be part of the standard Super-FRS detection system, as tracker detectors at several focal stations along the separator and its three branches.
The GEM-TPC detector will be part of the standard Super-FRS detection system, as tracker detectors at several focal stations along the separator and its three branches.
△ Less
Submitted 16 December, 2016;
originally announced December 2016.
-
Characterization of a cylindrical plastic β-detector with Monte Carlo simulations of optical photons
Authors:
V. Guadilla,
A. Algora,
J. L. Tain,
J. Agramunt,
J. Äystö,
J. A. Briz,
A. Cucoanes,
T. Eronen,
M. Estienne,
M. Fallot,
L. M. Fraile,
E. Ganioglu,
W. Gelletly,
D. Gorelov,
J. Hakala,
A. Jokinen,
D. Jordan,
A. Kankainen,
V. Kolhinen,
J. Koponen,
M. Lebois,
T. Martinez,
M. Monserrate,
A. Montaner-Pizá,
I. Moore
, et al. (17 additional authors not shown)
Abstract:
In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic \b{eta}-detector with cylindrical geometry. Since energy deposition simulations differ from the experimental measurements for such a geometry, we show how the simulation of production and transport of optical photons does allow one to obtain the shapes of the experimenta…
▽ More
In this work we report on the Monte Carlo study performed to understand and reproduce experimental measurements of a new plastic \b{eta}-detector with cylindrical geometry. Since energy deposition simulations differ from the experimental measurements for such a geometry, we show how the simulation of production and transport of optical photons does allow one to obtain the shapes of the experimental spectra. Moreover, taking into account the computational effort associated with this kind of simulation, we develop a method to convert the simulations of energy deposited into light collected, depending only on the interaction point in the detector. This method represents a useful solution when extensive simulations have to be done, as in the case of the calculation of the response function of the spectrometer in a total absorption γ-ray spectroscopy analysis.
△ Less
Submitted 22 November, 2016;
originally announced November 2016.