-
Modern approach to muonic x-ray spectroscopy demonstrated through the measurement of stable Cl radii
Authors:
K. A. Beyer,
T. E. Cocolios,
C. Costache,
M. Deseyn,
P. Demol,
A. Doinaki,
O. Eizenberg,
M. Gorshteyn,
M. Heines,
A. Herzáň,
P. Indelicato,
K. Kirch,
A. Knecht,
R. Lica,
V. Matousek,
E. A. Maugeri,
B. Ohayon,
N. S. Oreshkina,
W. W. M. M. Phyo,
R. Pohl,
S. Rathi,
W. Ryssens,
A. Turturica,
K. von Schoeler,
I. A. Valuev
, et al. (3 additional authors not shown)
Abstract:
Recent advances in muonic x-ray experiments have reinvigorated efforts in measurements of absolute nuclear charge radii. Here, a modern approach is presented, and demonstrated through determination of the charge radii of the two stable chlorine nuclides $^{35}$Cl and $^{37}$Cl. Knowledge of these radii has implications for fundamental studies in nuclear and atomic physics. For this purpose, a stat…
▽ More
Recent advances in muonic x-ray experiments have reinvigorated efforts in measurements of absolute nuclear charge radii. Here, a modern approach is presented, and demonstrated through determination of the charge radii of the two stable chlorine nuclides $^{35}$Cl and $^{37}$Cl. Knowledge of these radii has implications for fundamental studies in nuclear and atomic physics. For this purpose, a state-of-the-art experiment was performed at the $π$E1 beamline in the Paul Scherrer Institute (Switzerland), using a large-scale HPGe detector array in order to extract precise energies of the muonic $^{35}$Cl and $^{37}$Cl $np1s$ transitions. The nuclear charge radius extraction relies on modern calculations for QED effects and nuclear polarization with rigorous uncertainty quantification, including effects that were not accounted for in older studies. Additionally, we established a new method for applying the nuclear shape correction directly from energy density functionals, which are amenable to isotopes for which no high-quality electron scattering experiments are available. The resulting charge radii are $3.3335(23) fm$ for $^{35}$Cl and $3.3445(23) fm$ for $^{37}$Cl, thus improving the uncertainty of the available electron scattering values by a factor of seven. The correlation of several observables was evaluated between the different isotopes in order to produce a more precise value of the differential mean square charge radius $δ\langle r^2 \rangle^{37, 35}=+0.0771(66) fm^{2}$. In this case, improvement of the uncertainty by more than one order of magnitude was achieved compared to the literature value. This precision is sufficient to use this differential as input for isotope shift factor determination.
△ Less
Submitted 11 June, 2025; v1 submitted 10 June, 2025;
originally announced June 2025.
-
Towards Precision Muonic X-Ray Measurements of Charge Radii of Light Nuclei
Authors:
Ben Ohayon,
Andreas Abeln,
Silvia Bara,
Thomas Elias Cocolios,
Ofir Eizenberg,
Andreas Fleischmann,
Loredana Gastaldo,
César Godinho,
Michael Heines,
Daniel Hengstler,
Guillaume Hupin,
Paul Indelicato,
Klaus Kirch,
Andreas Knecht,
Daniel Kreuzberger,
Jorge Machado,
Petr Navratil,
Nancy Paul,
Randolf Pohl,
Daniel Unger,
Stella Vogiatzi,
Katharina von Schoeler,
Frederik Wauters
Abstract:
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyon…
▽ More
We propose an experiment to measure the nuclear charge radii of light elements with up to 20~times higher accuracy. These are essential both for understanding nuclear physics at low energies, and for experimental and theoretical applications in simple atomic systems. Such comparisons advance the understanding of bound-state quantum electrodynamics and are useful for searching for new physics beyond the Standard Model. The energy levels of muonic atoms are highly susceptible to nuclear structure, especially to the mean square charge radius. The radii of the lightest nuclei (with the atomic number, $Z=1,2$) have been determined with high accuracy using laser spectroscopy in muonic atoms, while those of medium mass and above were determined using X-ray spectroscopy with semiconductor detectors. In this communication, we present a new experiment, aiming to obtain precision measurements of the radii of light nuclei $3 \leq Z \leq 10$ using single-photon energy measurements with cryogenic microcalorimeters; a quantum-sensing technology capable of high efficiency with outstanding resolution for low-energy X-rays.
△ Less
Submitted 17 February, 2024; v1 submitted 5 October, 2023;
originally announced October 2023.
-
Development of wide range photon detection system for muonic X-ray spectroscopy
Authors:
R. Mizuno,
M. Niikura,
T. Y. Saito,
T. Matsuzaki,
H. Sakurai,
A. Amato,
S. Asari,
S. Biswas,
I. Chiu,
L. Gerchow,
Z. Guguchia,
G. Janka,
K. Ninomiya,
N. Ritjoho,
A. Sato,
K. von Schoeler,
D. Tomono,
K. Terada,
C. Wang
Abstract:
We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition system. The absolute energy accuracy, energy and timing resolutions, photo-peak efficiency, the performance of the Compton suppressor, and high count rate durabi…
▽ More
We have developed a photon detection system for muonic X-ray spectroscopy. The detector system consists of high-purity germanium detectors with BGO Compton suppressors. The signals from the detectors are readout with a digital acquisition system. The absolute energy accuracy, energy and timing resolutions, photo-peak efficiency, the performance of the Compton suppressor, and high count rate durability are studied with standard $γ$-ray sources and in-beam experiment using $^{27}\mathrm{Al}(p, γ){}^{28}\mathrm{Si}$ resonance reaction. The detection system was demonstrated at Paul Scherrer Institute. A calibration method for a photon detector at a muon facility using muonic X-rays of $^{197}$Au and $^{209}$Bi is proposed.
△ Less
Submitted 18 December, 2023; v1 submitted 31 August, 2023;
originally announced September 2023.
-
Muonic atom spectroscopy with microgram target material
Authors:
A. Adamczak,
A. Antognini,
N. Berger,
T. E. Cocolios,
N. Deokar,
Ch. E. Düllmann,
A. Eggenberger,
R. Eichler,
M. Heines,
H. Hess,
P. Indelicato,
K. Kirch,
A. Knecht,
J. J. Krauth,
J. Nuber,
A. Ouf,
A. Papa,
R. Pohl,
E. Rapisarda,
P. Reiter,
N. Ritjoho,
S. Roccia,
M. Seidlitz,
N. Severijns,
K. von Schoeler
, et al. (4 additional authors not shown)
Abstract:
Muonic atom spectroscopy -- the measurement of the x rays emitted during the formation process of a muonic atom -- has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However,…
▽ More
Muonic atom spectroscopy -- the measurement of the x rays emitted during the formation process of a muonic atom -- has a long standing history in probing the shape and size of nuclei. In fact, almost all stable elements have been subject to muonic atom spectroscopy measurements and the absolute charge radii extracted from these measurements typically offer the highest accuracy available. However, so far only targets of at least a few hundred milligram could be used as it required to stop a muon beam directly in the target to form the muonic atom. We have developed a new method relying on repeated transfer reactions taking place inside a 100-bar hydrogen gas cell with an admixture of 0.25% deuterium that allows us to drastically reduce the amount of target material needed while still offering an adequate efficiency. Detailed simulations of the transfer reactions match the measured data, suggesting good understanding of the processes taking place inside the gas mixture. As a proof of principle we demonstrate the method with a measurement of the 2p-1s muonic x rays from a 5-μg gold target.
△ Less
Submitted 2 June, 2023; v1 submitted 28 September, 2022;
originally announced September 2022.