-
Features of the EAR2 neutron beam following the spallation target upgrade at the n_TOF facility at CERN
Authors:
J. A. Pavon-Rodriguez,
J. Lerendegui-Marco,
A. Manna,
S. Amaducci,
M. Sabate-Gilarte,
E. Musacchio-Gonzalez,
M. Bacak,
V. Alcayne,
M. A.,
Cortes-Giraldo,
V. Vlachoudis,
R. Zarrella,
F. Garcia-Infantes,
E. Stamati,
A. Casanovas,
N. Patronis,
L. Tassan-Got,
J. M. Quesada,
the n_TOF Collaboration
Abstract:
The n_TOF facility at CERN has undergone a major upgrade after the installation of a new spallation target, designed to improve the features of both neutron beamlines at the experimental areas 1 and 2 (EAR1 and EAR2) and the commissioning of a new experimental area (NEAR). Due to improved coupling of the spallation target with the EAR2 beamline, the upgrade resulted in a significantly increased ne…
▽ More
The n_TOF facility at CERN has undergone a major upgrade after the installation of a new spallation target, designed to improve the features of both neutron beamlines at the experimental areas 1 and 2 (EAR1 and EAR2) and the commissioning of a new experimental area (NEAR). Due to improved coupling of the spallation target with the EAR2 beamline, the upgrade resulted in a significantly increased neutron flux and improved neutron energy resolution. This paper presents the results of the commissioning phase that followed to characterise the EAR2 neutron beamline and validate the FLUKA Monte Carlo simulations of the facility. The main features of the neutron beam, namely the neutron flux, spatial profile and energy resolution, are evaluated and compared to the previous target. The neutron flux presents a general increase of 20% below 1 eV, 40% between 1 eV and 100 keV and 50% between 100 keV and 10 MeV. The measured width of the beam profile was 3 cm (FWHM) at the reference position for neutron capture measurements. The energy resolution with the new spallation target shows a significant improvement compared to the previous one. Moreover, FLUKA Monte Carlo simulations present a good agreement with the measured neutron flux and profile within uncertainties, and a remarkable reproduction of the energy resolution.
△ Less
Submitted 29 April, 2025;
originally announced May 2025.
-
Radiative neutron capture cross section of $^{242}$Pu measured at n_TOF-EAR1 in the unresolved resonance region up to 600 keV
Authors:
J. Lerendegui-Marco,
C. Guerrero,
E. Mendoza,
J. M. Quesada,
K. Eberhardt,
A. R. Junghans,
V. Alcayne,
V. Babiano,
O. Aberle,
J. Andrzejewski,
L. Audouin,
V. Becares,
M. Bacak,
J. Balibrea-Correa,
M. Barbagallo,
S. Barros,
F. Becvar,
C. Beinrucker,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
M. Brugger,
M. Caamaño,
F. Calviño,
M. Calviani
, et al. (111 additional authors not shown)
Abstract:
The design of fast reactors burning MOX fuels requires accurate capture and fission cross sections. For the particular case of neutron capture on 242Pu, the NEA recommends that an accuracy of 8-12% should be achieved in the fast energy region (2 keV-500 keV) compared to their estimation of 35% for the current uncertainty. Integral irradiation experiments suggest that the evaluated cross section of…
▽ More
The design of fast reactors burning MOX fuels requires accurate capture and fission cross sections. For the particular case of neutron capture on 242Pu, the NEA recommends that an accuracy of 8-12% should be achieved in the fast energy region (2 keV-500 keV) compared to their estimation of 35% for the current uncertainty. Integral irradiation experiments suggest that the evaluated cross section of the JEFF-3.1 library overestimates the 242Pu(n,γ) cross section by 14% in the range between 1 keV and 1 MeV. In addition, the last measurement at LANSCE reported a systematic reduction of 20-30% in the 1-40 keV range relative to the evaluated libraries and previous data sets. In the present work this cross section has been determined up to 600 keV in order to solve the mentioned discrepancies. A 242Pu target of 95(4) mg enriched to 99.959% was irradiated at the n TOF-EAR1 facility at CERN. The capture cross section of 242Pu has been obtained between 1 and 600 keV with a systematic uncertainty (dominated by background subtraction) between 8 and 12%, reducing the current uncertainties of 35% and achieving the accuracy requested by the NEA in a large energy range. The shape of the cross section has been analyzed in terms of average resonance parameters using the FITACS code as implemented in SAMMY, yielding results compatible with our recent analysis of the resolved resonance region.The results are in good agreement with the data of Wisshak and Käppeler and on average 10-14% below JEFF-3.2 from 1 to 250 keV, which helps to achieve consistency between integral experiments and cross section data. At higher energies our results show a reasonable agreement within uncertainties with both ENDF/B-VII.1 and JEFF-3.2. Our results indicate that the last experiment from DANCE underestimates the capture cross section of 242Pu by as much as 40% above a few keV.
△ Less
Submitted 2 December, 2024;
originally announced December 2024.
-
A Segmented Total Energy Detector (sTED) optimized for $(n,γ)$ cross-section measurements at n_TOF EAR2
Authors:
V. Alcayne,
D. Cano-Ott,
J. Garcia,
E. Gonzalez-Romero,
T. Martinez,
A. Perez de Rada,
J. Plaza,
A. Sanchez-Caballero,
J. Balibrea-Correa,
C. Domingo-Pardo,
J. Lerendegui-Marco,
A. Casanovas,
F. Calvino,
O. Aberle,
the n_TOF collaboration
Abstract:
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of $4\times 10^7$ neutrons per nominal proton pulse, which is 50 times higher than the one of Expe…
▽ More
The neutron time-of-flight facility n_TOF at CERN is a spallation source dedicated to measurements of neutron-induced reaction cross-sections of interest in nuclear technologies, astrophysics, and other applications. Since 2014, Experimental ARea 2 (EAR2) is operational and delivers a neutron fluence of $4\times 10^7$ neutrons per nominal proton pulse, which is 50 times higher than the one of Experimental ARea 1 (EAR1) of $8\times10^5$ neutrons per pulse. The high neutron flux at EAR2 results in high counting rates in the detectors that challenged the previously existing capture detection systems. For this reason, a Segmented Total Energy Detector (sTED) has been developed to overcome the limitations in the detectors response, by reducing the active volume per module and by using a photomultiplier (PMT) optimized for high counting rates. This paper presents the main characteristics of the sTED, including energy and time resolution, response to $γ$-rays, and provides as well details of the use of the Pulse Height Weighting Technique (PHWT) with this detector. The sTED has been validated to perform neutron-capture cross-section measurements in EAR2 in the neutron energy range from thermal up to at least 400 keV. The detector has already been successfully used in several measurements at n_TOF EAR2.
△ Less
Submitted 14 March, 2024;
originally announced March 2024.
-
Recent highlights and prospects on (n,$γ$) measurements at the CERN n_TOF facility
Authors:
J. Lerendegui-Marco,
V. Alcayne,
V. Babiano-Suarez,
M. Bacak,
J. Balibrea-Correa,
A. Casanovas,
C. Domingo-Pardo,
G. de la Fuente,
B. Gameiro,
F. García-Infantes,
I. Ladarescu,
E. Musacchio-Gonzalez,
J. A. Pavón-Rodríguez,
A. Tarifeño-Saldivia,
the n_TOF Collaboration
Abstract:
Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear technologies. One of the best suited methods to measure radiative neutron capture (n,$γ$) cross sections over the full stellar range of interest for all the applications is the time-of-flight (TOF) technique. Overcoming th…
▽ More
Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear technologies. One of the best suited methods to measure radiative neutron capture (n,$γ$) cross sections over the full stellar range of interest for all the applications is the time-of-flight (TOF) technique. Overcoming the current experimental limitations for TOF measurements, in particular on low mass unstable samples, requires the combination of facilities with high instantaneous flux, such as the CERN n_TOF facility, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution presents a summary about the recent highlights in the field of (n,$γ$) measurements at n_TOF. The recent upgrades in the facility and in new detector concepts for (n,\g) measurements are described. Last, an overview is given on the existing limitations and prospects for TOF measurements involving unstable targets and the outlook for activation measurements at the brand new high-flux n_TOF-NEAR station.
△ Less
Submitted 24 October, 2023;
originally announced October 2023.
-
New perspectives for neutron capture measurements in the upgraded CERN-n_TOF Facility
Authors:
J. Lerendegui-Marco,
A. Casanovas,
V. Alcayne,
the n_TOF Collaboration
Abstract:
The n_TOF facility has just undergone in 2021 a major upgrade with the installation of its third generation spallation target that has been designed to optimize the performance of the two n_TOF time-of-flight lines. This contribution describes the key features and limitations for capture measurements in the two beam lines prior to the target upgrade and presents first results of (n,$γ$) measuremen…
▽ More
The n_TOF facility has just undergone in 2021 a major upgrade with the installation of its third generation spallation target that has been designed to optimize the performance of the two n_TOF time-of-flight lines. This contribution describes the key features and limitations for capture measurements in the two beam lines prior to the target upgrade and presents first results of (n,$γ$) measurements carried out as part of the commissioning of the upgraded facility. In particular, the energy resolution, a key factor for both increasing the signal-to-background ratio and obtaining accurate resonance parameters, has been clearly improved for the 20 m long vertical beam-line with the new target design while keeping the remarkably high resolution of the long beamline n_TOF-EAR1. The improvements in the n_TOF neutron beam-lines need to be accompanied by improvements in the instrumentation. A review is given on recent detector R&D projects aimed at tackling the existing challenges and further improving the capabilities of this facility.
△ Less
Submitted 15 March, 2023;
originally announced March 2023.
-
New detection systems for an enhanced sensitivity in key stellar (n,$γ$) measurements
Authors:
J. Lerendegui-Marco,
V. Babiano-Suárez,
J. Balibrea-Correa,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
C. Guerrero,
F. Calviño,
A. Casanovas,
U. Köster,
N. M. Chiera,
R. Dressler,
E. A. Maugeri,
D. Schumann,
the n_TOF Collaboration
Abstract:
Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key $s$-process nuclei are often challenging. Difficulties arise from the limited mass ($\sim$mg) available and t…
▽ More
Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key $s$-process nuclei are often challenging. Difficulties arise from the limited mass ($\sim$mg) available and the high sample-related background in the case of the unstable $s$-process branching points. Measurements on neutron magic nuclei, that act as $s$-process bottlenecks, are affected by low (n,$γ$) cross sections and a dominant neutron scattering background. Overcoming these experimental challenges requires the combination of facilities with high instantaneous flux, such as n\_TOF-EAR2, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution reviews some of the latest detector developments in detection systems for (n,$γ$) measurements at n\_TOF, such as i-TED, an innovative detection system which exploits the Compton imaging technique to reduce the dominant neutron scattering background and s-TED, a highly segmented total energy detector intended for high flux facilities. The discussion will be illustrated with results of the first measurement of key the $s$-process branching-point reaction $^{79}$Se(n,$γ$).
△ Less
Submitted 15 March, 2023;
originally announced March 2023.
-
First measurement of the $^{94}$Nb($n$,$γ$) cross section at the CERN n\_TOF facility
Authors:
J. Balibrea-Correa,
V. Babiano-Suarez,
J. Lerendegui-Marco,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
J. Plaza,
A. Sánchez-Caballero,
F. Calviño,
A. Casanovas,
C. Guerrero,
S. Heinitz,
U. Köster,
E. A. Maugeri,
R. Dressler,
D. Schumann,
I. Mönch,
S. Cristallo,
C. Lederer-Woods,
O. Aberle
, et al. (112 additional authors not shown)
Abstract:
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along di…
▽ More
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along different stages of stellar evolution.In the particular case of the radioactive $^{94}$Nb, the $^{94}$Nb($n$,$γ$) cross-section could play a role in the determination of the $s$-process production of $^{94}$Mo in AGB stars, which presently cannot be reproduced by state-of-the-art stellar models. There are no previous $^{94}$Nb($n$,$γ$) experimental data for the resolved and unresolved resonance regions mainly due to the difficulties in producing high-quality samples and also due to limitations in conventional detection systems commonly used in time-of-flight experiments.Motivated by this situation, a first measurement of the $^{94}$Nb($n$,$γ$) reaction was carried out at CERN n\_TOF, thereby exploiting the high luminosity of the EAR2 area in combination with a new detection system of small-volume C6D6-detectors and a high quality $^{94}$Nb-sample. The latter was based on hyper-pure $^{93}$Nb material activated at the high-flux reactor of ILL-Grenoble. An innovative ring-configuration detection system in close geometry around the capture sample allowed us to significantly enhance the signal-to-background ratio. This set-up was supplemented with two conventional C$_{6}$D$_{6}$ detectors and a high-resolution LaCl$_{3}$(Ce)-detector, which will be employed for addressing reliably systematic effects and uncertainties.At the current status of the data analysis, 18 resonance in $^{94}$Nb+$n$ have been observed for the first time in the neutron energy range from thermal up to 10 keV.
△ Less
Submitted 20 February, 2023; v1 submitted 26 January, 2023;
originally announced January 2023.
-
High accuracy, high resolution 235U(n,f) cross section from n_TOF (CERN) in the thermal to 10 keV energy range
Authors:
n_TOF collaboration,
:,
M. Mastromarco,
S. Amaducci,
N. Colonna,
P. Finocchiaro,
L. Cosentino,
O. Aberle,
J. Andrzejewski,
L. Audouin,
M. Bacak,
J. Balibrea,
M. Barbagallo,
F. Bečvář,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown,
M. Caamaño,
F. Calviño,
M. Calviani,
D. Cano-Ott,
R. Cardella,
A. Casanovas,
F. Cerutti
, et al. (98 additional authors not shown)
Abstract:
The 235U(n,f) cross section was measured in a wide energy range (25 meV - 170 keV) at the n_TOF facility at CERN, relative to 6Li(n,t) and 10B(n,alpha) standard reactions, with high resolution and accuracy, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. In this paper we report on the results in the region between thermal and 10 keV neutron energy…
▽ More
The 235U(n,f) cross section was measured in a wide energy range (25 meV - 170 keV) at the n_TOF facility at CERN, relative to 6Li(n,t) and 10B(n,alpha) standard reactions, with high resolution and accuracy, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. In this paper we report on the results in the region between thermal and 10 keV neutron energy. A resonance analysis has been performed up to 200 eV, with the code SAMMY. The resulting fission kernels are compared with the ones extracted on the basis of the resonance parameters of the most recent major evaluated data libraries. A comparison of the n_TOF data with the evaluated cross sections is also performed from thermal to 10 keV neutron energy for the energy-averaged cross section in energy groups of suitably chosen width. A good agreement is found in average between the new results and the latest evaluated data files ENDF-B/VIII and JEFF-3.3, as well as with respect to the IAEA reference files. However, some discrepancies are still present in some specific energy regions. The new dataset here presented, characterized by unprecedented resolution and accuracy, can help improving the evaluations in the Resolved Resonance Region and up to 10 keV, and reduce the uncertainties that affect this region.
△ Less
Submitted 2 February, 2022;
originally announced February 2022.
-
Measurement of the $^{154}$Gd(n,$γ$) cross section and its astrophysical implications
Authors:
A. Mazzone,
S. Cristallo,
C. Massimi,
the n_TOF Collaboration
Abstract:
The neutron capture cross section of $^{154}$Gd was measured from 1 eV to 300 keV in the experimental area located 185 m from the CERN n\_TOF neutron spallation source, using a metallic sample of gadolinium, enriched to 67$\%$ in $^{154}$Gd. The capture measurement, performed with four C$_{6}$D$_{6}$ scintillation detectors, has been complemented by a transmission measurement performed at the GELI…
▽ More
The neutron capture cross section of $^{154}$Gd was measured from 1 eV to 300 keV in the experimental area located 185 m from the CERN n\_TOF neutron spallation source, using a metallic sample of gadolinium, enriched to 67$\%$ in $^{154}$Gd. The capture measurement, performed with four C$_{6}$D$_{6}$ scintillation detectors, has been complemented by a transmission measurement performed at the GELINA time-of-flight facility (JRC-Geel), thus minimising the uncertainty related to sample composition. An accurate Maxwellian averaged capture cross section (MACS) was deduced over the temperature range of interest for s process nucleosynthesis modeling. We report a value of 880(50) mb for the MACS at $kT=30$ keV, significantly lower compared to values available in literature. The new adopted $^{154}$Gd(n,$γ$) cross section reduces the discrepancy between observed and calculated solar s-only isotopic abundances predicted by s-process nucleosynthesis models.
△ Less
Submitted 6 February, 2020;
originally announced February 2020.
-
Measurement of the $^{70}$Ge($n,γ$) cross section up to 300~keV at the CERN n_TOF facility
Authors:
A. Gawlik,
C. Lederer-Woods,
the n_TOF collaboration
Abstract:
Neutron capture data on intermediate mass nuclei are of key importance to nucleosynthesis in the weak component of the slow neutron capture processes, which occurs in massive stars. The ($n,γ$) cross section on $^{70}$Ge, which is mainly produced in the $s$~process, was measured at the neutron time-of-flight facility n_TOF at CERN. Resonance capture kernels were determined up to 40~keV neutron ene…
▽ More
Neutron capture data on intermediate mass nuclei are of key importance to nucleosynthesis in the weak component of the slow neutron capture processes, which occurs in massive stars. The ($n,γ$) cross section on $^{70}$Ge, which is mainly produced in the $s$~process, was measured at the neutron time-of-flight facility n_TOF at CERN. Resonance capture kernels were determined up to 40~keV neutron energy, and average cross sections up to 300~keV. Stellar cross sections were calculated from $kT=5$~keV to $kT=100$ keV and are in very good agreement with a previous measurement by Walter and Beer (1985), and recent evaluations. Average cross sections are in agreement with Walter and Beer (1985) over most of the neutron energy range covered, while being systematically smaller for neutron energies above 150~keV. We have calculated isotopic abundances produced in $s$-process environments in a 25 solar mass star for two initial metallicities (below solar, and close to solar). While the low metallicity model reproduces best the solar system germanium isotopic abundances the close to solar model shows a good global match to solar system abundances between mass numbers A=60-80.
△ Less
Submitted 21 October, 2019;
originally announced October 2019.
-
Neutron spectroscopy of $^{26}$Mg states: constraining the stellar neutron source $^{22}$Ne($α, n$)$^{25}$Mg
Authors:
C. Massimi,
The n_TOF Collaboration
Abstract:
This work reports on accurate, high-resolution measurements of the $^{25}$Mg($n, γ$)$^{26}$Mg and $^{25}$Mg($n, tot$) cross sections in the neutron energy range from thermal to about 300 keV, leading to a significantly improved $^{25}$Mg($n, γ$)$^{26}$Mg parametrization. The relevant resonances for $n+^{25}$Mg were characterized from a combined R-matrix analysis of the experimental data. This resu…
▽ More
This work reports on accurate, high-resolution measurements of the $^{25}$Mg($n, γ$)$^{26}$Mg and $^{25}$Mg($n, tot$) cross sections in the neutron energy range from thermal to about 300 keV, leading to a significantly improved $^{25}$Mg($n, γ$)$^{26}$Mg parametrization. The relevant resonances for $n+^{25}$Mg were characterized from a combined R-matrix analysis of the experimental data. This resulted in an unambiguous spin/parity assignment of the corresponding excited states in $^{26}$Mg. With this information experimental upper limits of the reaction rates for $^{22}$Ne($α, n$)$^{25}$Mg and $^{22}$Ne($α, γ$)$^{26}$Mg were established, potentially leading to a significantly higher ($α, n$)/($α, γ$) ratio than previously evaluated. The impact of these results have been studied for stellar models in the mass range 2 to 25 $M_{\odot}$.
△ Less
Submitted 15 February, 2017;
originally announced February 2017.
-
Neutron capture cross section measurement of 238U at the n TOF CERN facility with C6D6 scintillation detectors in the energy region from 1 eV to 700 keV
Authors:
n_TOF Collaboration,
:,
F. Mingrone,
C. Massimi,
G. Vannini,
N. Colonna,
F. Gunsing,
P. Žugec,
S. Altstadt,
J. Andrzejewski,
L. Audouin,
M. Barbagallo,
V. Bécares,
F. Bečvář,
F. Belloni,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
M. Brugger,
M. Calviani,
F. Calviño,
D. Cano-Ott,
C. Carrapiço,
F. Cerutti,
E. Chiaveri
, et al. (81 additional authors not shown)
Abstract:
The aim of this work is to provide a precise and accurate measurement of the 238U(n,g) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behaviour of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive…
▽ More
The aim of this work is to provide a precise and accurate measurement of the 238U(n,g) reaction cross section in the energy region from 1 eV to 700 keV. This reaction is of fundamental importance for the design calculations of nuclear reactors, governing the behaviour of the reactor core. In particular, fast reactors, which are experiencing a growing interest for their ability to burn radioactive waste, operate in the high energy region of the neutron spectrum. In this energy region most recent evaluations disagree due to inconsistencies in the existing measurements of up to 15%. In addition, the assessment of nuclear data uncertainty performed for innovative reactor systems shows that the uncertainty in the radiative capture cross-section of 238U should be further reduced to 1-3% in the energy region from 20 eV to 25 keV. To this purpose, addressed by the Nuclear Energy Agency as a priority nuclear data need, complementary experiments, one at the GELINA and two at the n_TOF facility, were proposed and carried out within the 7th Framework Project ANDES of the European Commission.
The results of one of these 238U(n,g) measurements performed at the n_TOF CERN facility are presented in this work. The gamma-ray cascade following the radiative neutron capture has been detected exploiting a setup of two C6D6 liquid scintillators. Resonance parameters obtained from this work are on average in excellent agreement with the ones reported in evaluated libraries. In the unresolved resonance region, this work yields a cross section in agreement with evaluated libraries up to 80 keV, while for higher energies our results are significantly higher.
△ Less
Submitted 1 December, 2016;
originally announced December 2016.
-
The 7Be(n,alpha)4He reaction and the Cosmological Lithium Problem: measurement of the cross section in a wide energy range at n_TOF (CERN)
Authors:
M. Barbagallo,
A. Musumarra,
L. Cosentino,
E. Maugeri,
S. Heinitz,
A. Mengoni,
R. Dressler,
D. Schumann,
F. Kaeppeler,
N. Colonna,
P. Finocchiaro,
M. Ayranov,
L. Damone,
N. Kivel,
n_TOF Collaboration
Abstract:
The energy-dependent cross section of the 7Be(n,alpha)4He reaction, of interest for the so-called Cosmological Lithium Problem in Big Bang Nucleosynthesis, has been measured for the first time from 10 meV to 10 keV neutron energy. The challenges posed by the short half-life of 7Be and by the low reaction cross section have been overcome at n_TOF thanks to an unprecedented combination of the extrem…
▽ More
The energy-dependent cross section of the 7Be(n,alpha)4He reaction, of interest for the so-called Cosmological Lithium Problem in Big Bang Nucleosynthesis, has been measured for the first time from 10 meV to 10 keV neutron energy. The challenges posed by the short half-life of 7Be and by the low reaction cross section have been overcome at n_TOF thanks to an unprecedented combination of the extremely high luminosity and good resolution of the neutron beam in the new experimental area (EAR2) of the n_TOF facility at CERN, the availability of a sufficient amount of chemically pure 7Be, and a specifically designed experimental setup. Coincidences between the two alpha-particles have been recorded in two Si-7Be-Si arrays placed directly in the neutron beam. The present results are consistent, at thermal neutron energy, with the only previous measurement performed in the 60's at a nuclear reactor. The energy dependence here reported clearly indicates the inadequacy of the cross section estimates currently used in BBN calculations. Although new measurements at higher neutron energy may still be needed, the n_TOF results hint to a minor role of this reaction in BBN, leaving the long-standing Cosmological Lithium problem unsolved.
△ Less
Submitted 30 June, 2016;
originally announced June 2016.
-
Experimental setup and procedure for the measurement of the 7Be(n,α)α reaction at n_TOF
Authors:
L. Cosentino,
A. Musumarra,
M. Barbagallo,
A. Pappalardo,
N. Colonna,
L. Damone,
M. Piscopo,
P. Finocchiaro,
E. Maugeri,
S. Heinitz,
D. Schumann,
R. Dressler,
N. Kivel,
O. Aberle,
J. Andrzejewski,
L. Audouin,
M. Ayranov,
M. Bacak,
S. Barros,
J. Balibrea-Correa,
V. Beecares,
F. Becvar,
C. Beinrucker,
E. Berthoumieux,
J. Billowes
, et al. (107 additional authors not shown)
Abstract:
The newly built second experimental area EAR2 of the n_TOF spallation neutron source at CERN allows to perform (n, charged particles) experiments on short-lived highly radioactive targets. This paper describes a detection apparatus and the experimental procedure for the determination of the cross-section of the 7Be(n,α) reaction, which represents one of the focal points toward the solution of the…
▽ More
The newly built second experimental area EAR2 of the n_TOF spallation neutron source at CERN allows to perform (n, charged particles) experiments on short-lived highly radioactive targets. This paper describes a detection apparatus and the experimental procedure for the determination of the cross-section of the 7Be(n,α) reaction, which represents one of the focal points toward the solution of the cosmological Lithium abundance problem, and whose only measurement, at thermal energy, dates back to 1963. The apparently unsurmountable experimental difficulties stemming from the huge 7Be γ-activity, along with the lack of a suitable neutron beam facility, had so far prevented further measurements. The detection system is subject to considerable radiation damage, but is capable of disentangling the rare reaction signals from the very high background. This newly developed setup could likely be useful also to study other challenging reactions requiring the detectors to be installed directly in the neutron beam.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.
-
First tests of the applicability of $γ$-ray imaging for background discrimination in time-of-flight neutron capture measurements
Authors:
D. L. Pérez Magán,
L. Caballero-Ontanaya,
C. Domingo-Pardo,
J. Agramunt-Ros,
F. Albiol,
A. Casanovas,
A. González,
C. Guerrero,
J. Lerendegui-Marco,
A. Tarifeño-Saldivia,
the n_TOF Collaboration
Abstract:
In this work we explore for the first time the applicability of using $γ$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr$_3$ scintillating crystal coupled to a position-sensitive photomultiplie…
▽ More
In this work we explore for the first time the applicability of using $γ$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr$_3$ scintillating crystal coupled to a position-sensitive photomultiplier and readout through an integrated circuit AMIC2GR. The pinhole collimator is a massive carven block of lead. A series of dedicated measurements with calibrated sources and with a neutron beam incident on a $^{197}$Au sample have been carried out at n_TOF, achieving an enhancement of a factor of two in the signal-to-background ratio when selecting only those events coming from the direction of the sample.
△ Less
Submitted 14 October, 2015; v1 submitted 8 October, 2015;
originally announced October 2015.
-
Measurement and analysis of the Am-243 neutron capture cross section at the n_TOF facility at CERN
Authors:
n_TOF Collaboration,
:,
E. Mendoza,
D. Cano-Ott,
C. Guerrero,
E. Berthoumieux,
U. Abbondanno,
G. Aerts,
F. Alvarez-Velarde,
S. Andriamonje,
J. Andrzejewski,
P. Assimakopoulos,
L. Audouin,
G. Badurek,
J. Balibrea,
P. Baumann,
F. Becvar,
F. Belloni,
F. Calvino,
M. Calviani,
R. Capote,
C. Carrapico,
A. Carrillo de Albornoz,
P. Cennini,
V. Chepel
, et al. (108 additional authors not shown)
Abstract:
Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$γ$) cross section uncertainty. Method: The $^{243}$Am(n,$γ$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV an…
▽ More
Background:The design of new nuclear reactors and transmutation devices requires to reduce the present neutron cross section uncertainties of minor actinides. Purpose: Reduce the $^{243}$Am(n,$γ$) cross section uncertainty. Method: The $^{243}$Am(n,$γ$) cross section has been measured at the n_TOF facility at CERN with a BaF$_{2}$ Total Absorption Calorimeter, in the energy range between 0.7 eV and 2.5 keV. Results: The $^{243}$Am(n,$γ$) cross section has been successfully measured in the mentioned energy range. The resolved resonance region has been extended from 250 eV up to 400 eV. In the unresolved resonance region our results are compatible with one of the two incompatible capture data sets available below 2.5 keV. The data available in EXFOR and in the literature has been used to perform a simple analysis above 2.5 keV. Conclusions: The results of this measurement contribute to reduce the $^{243}$Am(n,$γ$) cross section uncertainty and suggest that this cross section is underestimated up to 25% in the neutron energy range between 50 eV and a few keV in the present evaluated data libraries.
△ Less
Submitted 4 December, 2014;
originally announced December 2014.
-
GEANT4 simulation of the neutron background of the C$_6$D$_6$ set-up for capture studies at n_TOF
Authors:
n_TOF collaboration,
:,
P. Žugec,
N. Colonna,
D. Bosnar,
S. Altstadt,
J. Andrzejewski,
L. Audouin,
M. Barbagallo,
V. Bécares,
F. Bečvář,
F. Belloni,
E. Berthoumieux,
J. Billowes,
V. Boccone,
M. Brugger,
M. Calviani,
F. Calviño,
D. Cano-Ott,
C. Carrapiço,
F. Cerutti,
E. Chiaveri,
M. Chin,
G. Cortés,
M. A. Cortés-Giraldo
, et al. (83 additional authors not shown)
Abstract:
The neutron sensitivity of the C$_6$D$_6$ detector setup used at n_TOF for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in t…
▽ More
The neutron sensitivity of the C$_6$D$_6$ detector setup used at n_TOF for capture measurements has been studied by means of detailed GEANT4 simulations. A realistic software replica of the entire n_TOF experimental hall, including the neutron beam line, sample, detector supports and the walls of the experimental area has been implemented in the simulations. The simulations have been analyzed in the same manner as experimental data, in particular by applying the Pulse Height Weighting Technique. The simulations have been validated against a measurement of the neutron background performed with a $^\mathrm{nat}$C sample, showing an excellent agreement above 1 keV. At lower energies, an additional component in the measured $^\mathrm{nat}$C yield has been discovered, which prevents the use of $^\mathrm{nat}$C data for neutron background estimates at neutron energies below a few hundred eV. The origin and time structure of the neutron background have been derived from the simulations. Examples of the neutron background for two different samples are demonstrating the important role of accurate simulations of the neutron background in capture cross section measurements.
△ Less
Submitted 26 June, 2014;
originally announced June 2014.
-
Experimental neutron capture data of $^{58}$Ni from the CERN n_TOF facility
Authors:
n_TOF collaboration,
:,
P. Žugec,
M. Barbagallo,
N. Colonna,
D. Bosnar,
S. Altstadt,
J. Andrzejewski,
L. Audouin,
V. Bécares,
F. Bečvář,
F. Belloni,
E. Berthoumieux,
J. Billowes,
V. Boccone,
M. Brugger,
M. Calviani,
F. Calviño,
D. Cano-Ott,
C. Carrapiço,
F. Cerutti,
E. Chiaveri,
M. Chin,
G. Cortés,
M. A. Cortés-Giraldo
, et al. (78 additional authors not shown)
Abstract:
The $^{58}$Ni $(n,γ)$ cross section has been measured at the neutron time of flight facility n_TOF at CERN, in the energy range from 27 meV up to 400 keV. In total, 51 resonances have been analyzed up to 122 keV. Maxwellian averaged cross sections (MACS) have been calculated for stellar temperatures of kT$=$5-100 keV with uncertainties of less than 6%, showing fair agreement with recent experiment…
▽ More
The $^{58}$Ni $(n,γ)$ cross section has been measured at the neutron time of flight facility n_TOF at CERN, in the energy range from 27 meV up to 400 keV. In total, 51 resonances have been analyzed up to 122 keV. Maxwellian averaged cross sections (MACS) have been calculated for stellar temperatures of kT$=$5-100 keV with uncertainties of less than 6%, showing fair agreement with recent experimental and evaluated data up to kT = 50 keV. The MACS extracted in the present work at 30 keV is 34.2$\pm$0.6$_\mathrm{stat}\pm$1.8$_\mathrm{sys}$ mb, in agreement with latest results and evaluations, but 12% lower relative to the recent KADoNIS compilation of astrophysical cross sections. When included in models of the s-process nucleosynthesis in massive stars, this change results in a 60% increase of the abundance of $^{58}$Ni, with a negligible propagation on heavier isotopes. The reason is that, using both the old or the new MACS, 58Ni is efficiently depleted by neutron captures.
△ Less
Submitted 5 February, 2014;
originally announced February 2014.
-
Measurement of the radiative neutron capture cross section of 206Pb and its astrophysical implications
Authors:
n_TOF Collaboration,
:,
C. Domingo-Pardo
Abstract:
The (n, gamma) cross section of 206Pb has been measured at the CERN n_TOF facility with high resolution in the energy range from 1 eV to 600 keV by using two optimized C6D6 detectors. In the investigated energy interval about 130 resonances could be observed, from which 61 had enough statistics to be reliably analyzed via the R-matrix analysis code SAMMY. Experimental uncertainties were minimize…
▽ More
The (n, gamma) cross section of 206Pb has been measured at the CERN n_TOF facility with high resolution in the energy range from 1 eV to 600 keV by using two optimized C6D6 detectors. In the investigated energy interval about 130 resonances could be observed, from which 61 had enough statistics to be reliably analyzed via the R-matrix analysis code SAMMY. Experimental uncertainties were minimized, in particular with respect to (i) angular distribution effects of the prompt capture gamma-rays, and to (ii) the TOF-dependent background due to sample-scattered neutrons. Other background components were addressed by background measurements with an enriched 208Pb sample. The effect of the lower energy cutoff in the pulse height spectra of the C6D6 detectors was carefully corrected via Monte Carlo simulations. Compared to previous 206Pb values, the Maxwellian averaged capture cross sections derived from these data are about 20% and 9% lower at thermal energies of 5 keV and 30 keV, respectively. These new results have a direct impact on the s-process abundance of 206Pb, which represents an important test for the interpretation of the cosmic clock based on the decay of 238U.
△ Less
Submitted 4 October, 2007; v1 submitted 25 July, 2007;
originally announced July 2007.