The J-PET detector -- a tool for precision studies of ortho-positronium decays
Authors:
K. Dulski,
S. D. Bass,
J. Chhokar,
N. Chug,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
J. Gajewski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
P. Kopka,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz
, et al. (19 additional authors not shown)
Abstract:
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events…
▽ More
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events is based on the measurement of the photons energies. In this article we show that the J-PET tomograph system is capable of exclusive measurements of the decays of ortho-positronium atoms. We present the first positronium production results, its lifetime distribution measurements and discuss estimation of the influence of various background sources. The tomograph s performance demonstrated here makes it suitable for precision studies of positronium decays including entanglement of the final state photons, positron annihilation lifetime spectroscopy plus molecular imaging diagnostics.
△ Less
Submitted 25 May, 2021; v1 submitted 9 June, 2020;
originally announced June 2020.
-
Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
Authors:
K. Dulski,
C. Curceanu,
E. Czerwiński,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak Ł. Kapłon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemień,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
K. Rakoczy,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of ana…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of analysis of the positron lifetime measured in the porous polymer. The obtained results prove that J-PET is capable of performing simultaneous imaging of the density distribution of annihilation points as well as positron annihilation lifetime spectroscopy.
△ Less
Submitted 12 September, 2018;
originally announced September 2018.
-
Analysis procedure of the positronium lifetime spectra for the J-PET detector
Authors:
K. Dulski,
B. Zgardzinska,
P. Bialas,
C. Curceanu E. Czerwinski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasinska,
D. Kisielewska-Kaminska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemiez,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedzwiecka,
S. Niedzwiecki,
M. Palka,
L. Raczynski,
J. Raj,
Z. Rudy,
N. G. Sharma,
S. Sharma
, et al. (8 additional authors not shown)
Abstract:
Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics…
▽ More
Positron Annihilation Lifetime Spectroscopy (PALS) has shown to be a powerful tool to study the nanostructures of porous materials. Positron Emissions Tomography (PET) are devices allowing imaging of metabolic processes e.g. in human bodies. A newly developed device, the J-PET (Jagiellonian PET), will allow PALS in addition to imaging, thus combining both analyses providing new methods for physics and medicine. In this contribution we present a computer program that is compatible with the J-PET software. We compare its performance with the standard program LT 9.0 by using PALS data from hexane measurements at different temperatures. Our program is based on an iterative procedure, and our fits prove that it performs as good as LT 9.0.
△ Less
Submitted 16 October, 2017;
originally announced October 2017.
-
Time calibration of the J-PET detector
Authors:
M. Skurzok,
M. Silarski,
D. Alfs,
P. Bialas,
Shivani,
C. Curceanu,
E. Czerwinski,
K. Dulski,
A. Gajos,
B. Glowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasinska,
D. Kisielewska-Kaminska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedzwiecka,
S. Niedzwiecki,
M. Palka,
L. Raczynski
, et al. (10 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cy…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) project carried out in the Institute of Physics of the Jagiellonian University is focused on construction and tests of the first prototype of PET scanner for medical diagnostic which allows for the simultaneous 3D imaging of the whole human body using organic scintillators. The J-PET prototype consists of 192 scintillator strips forming three cylindrical layers which are optimized for the detection of photons from the electron-positron annihilation with high time- and high angular-resolutions. In this article we present time calibration and synchronization of the whole J-PET detection system by irradiating each single detection module with a 22Na source and a small detector providing common reference time for synchronization of all the modules.
△ Less
Submitted 16 October, 2017;
originally announced October 2017.
-
Trilateration-based reconstruction of ortho-positronium decays into three photons with the J-PET detector
Authors:
A. Gajos,
D. Kamińska,
E. Czerwiński,
D. Alfs,
T. Bednarski,
P. Białas,
B. Głowacz,
M. Gorgol,
B. Jasińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski
, et al. (6 additional authors not shown)
Abstract:
This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based…
▽ More
This work reports on a new reconstruction algorithm allowing to reconstruct the decays of ortho-positronium atoms into three photons using the places and times of photons recorded in the detector. The method is based on trilateration and allows for a simultaneous reconstruction of both location and time of the decay. Results of resolution tests of the new reconstruction in the J-PET detector based on Monte Carlo simulations are presented, which yield a spatial resolution at the level of 2 cm (FWHM) for X and Y and at the level of 1 cm (FWHM) for Z available with the present resolution of J-PET after application of a kinematic fit. Prospects of employment of this method for studying angular correlations of photons in decays of polarized ortho-positronia for the needs of tests of CP and CPT discrete symmetries are also discussed. The new reconstruction method allows for discrimination of background from random three-photon coincidences as well as for application of a novel method for determination of the linear polarization of ortho-positronium atoms, which is also introduced in this work.
△ Less
Submitted 24 February, 2016;
originally announced February 2016.
-
Determination of the 3γfraction from positron annihilation in mesoporous materials for symmetry violation experiment with J-PET scanner
Authors:
B. Jasińska,
M. Gorgol,
M. Wiertel,
R. Zaleski,
D. Alfs,
T. Bednarski,
P. Białas,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
D. Kamińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma
, et al. (8 additional authors not shown)
Abstract:
Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3γannihilation determined using γ-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elem…
▽ More
Various mesoporous materials were investigated to choose the best material for experiments requiring high yield of long-lived positronium. We found that the fraction of 3γannihilation determined using γ-ray energy spectra and positron annihilation lifetime spectra (PAL) changed from 20% to 25%. The 3gamma fraction and o-Ps formation probability in the polymer XAD-4 is found to be the largest. Elemental analysis performed using scanning electron microscop (SEM) equipped with energy-dispersive X-ray spectroscop EDS show high purity of the investigated materials.
△ Less
Submitted 17 February, 2016;
originally announced February 2016.
-
Reconstruction of hit-time and hit-position of annihilation quanta in the J-PET detector using the Mahalanobis distance
Authors:
N. G. Sharma,
M. Silarski,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
M. Gorgol,
B. Jasińska,
D. Kamińska,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
Sz. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
A. Słomski,
A. Strzelecki,
A. Wieczorek,
W. Wiślicki,
M. Zieliński
, et al. (2 additional authors not shown)
Abstract:
The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a…
▽ More
The J-PET detector being developed at Jagiellonian University, is a Positron Emission Tomograph composed of the long strips of polymer scintillators. At the same time it is a detector system which will be used for studies of the decays of positronium atoms. The shape of photomultiplier signals depends on the hit-time and hit-position of the gamma quantum. In order to take advantage of this fact a dedicated sampling front-end electronics which enables to sample signals in voltage domain with the time precision of about 20 ps and novel reconstruction method based on the comparison of examined signal with the model signals stored in the library has been developed. As a measure of the similarity we use the Mahalanobis distance. The achievable position and time-resolution depends on number and values of the threshold levels at which the signal is sampled. A reconstruction method, as well as preliminary results are presented and discussed.
△ Less
Submitted 29 August, 2015;
originally announced August 2015.
-
PALS investigations of free volumes thermal expansion of J-PET plastic scintillator synthesized in polystyrene matrix
Authors:
A. Wieczorek,
B. Zgardzińska,
B. Jasińska,
M. Gorgol,
T. Bednarski,
P. Białas,
E. Czerwiński,
A. Gajos,
D. Kamińska,
Ł. Kapłon,
A. Kochanowski,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
S. Niedźwiecki,
M. Pałka,
L. Raczyński,
Z. Rudy,
O. Rundel,
N. G. Sharma,
M. Silarski,
A. Słomski,
A. Strzelecki
, et al. (3 additional authors not shown)
Abstract:
The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant h…
▽ More
The polystyrene dopped with 2,5-diphenyloxazole as a primary fluor and 2-(4-styrylphenyl)benzoxazole as a wavelength shifter, prepared as a plastic scintillator was investigated using positronium probe in wide range of temperatures from 123 to 423 K. Three structural transitions at 260 K, 283 K and 370 K were found in the material. In the o-Ps intensity dependence on temperature, the significant hysteresis is observed. Heated to 370 K, the material exhibits the o-Ps intensity variations in time.
△ Less
Submitted 27 August, 2015;
originally announced August 2015.