Detector performance of the Gamma-ray Transient Monitor onboard DRO-A Satellite
Authors:
Pei-Yi Feng,
Zheng-Hua An,
Da-Li Zhang,
Chen-Wei Wang,
Chao Zheng,
Sheng Yang,
Shao-Lin Xiong,
Jia-Cong Liu,
Xin-Qiao Li,
Ke Gong,
Xiao-Jing Liu,
Min Gao,
Xiang-Yang Wen,
Ya-Qing liu,
Xiao-Yun Zhao,
Fan Zhang,
Xi-Lei Sun,
Hong Lu
Abstract:
Gamma-ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 keV to 1 MeV. GTM is equipped with 5 Gamma-ray Transient Probe (GTP) detector modules, utilizing the NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP makes use of a dedicated dua…
▽ More
Gamma-ray Transient Monitor (GTM) is an all-sky monitor onboard the Distant Retrograde Orbit-A (DRO-A) satellite with the scientific objective of detecting gamma-ray transients ranging from 20 keV to 1 MeV. GTM is equipped with 5 Gamma-ray Transient Probe (GTP) detector modules, utilizing the NaI(Tl) scintillator coupled with a SiPM array. To reduce the SiPM noise, GTP makes use of a dedicated dual-channel coincident readout design. In this work, we firstly studied the impact of different coincidence times on detection efficiency and ultimately selected the 500 ns time coincidence window for offline data processing. To test the performance of GTPs and validate the Monte Carlo simulated energy response, we conducted comprehensive ground calibration tests using Hard X-ray Calibration Facility (HXCF) and radioactive sources, including energy response, detection efficiency, spatial response, bias-voltage response, and temperature dependence. We extensively presented the ground calibration results, and validated the design and mass model of GTP detector. These work paved the road for the in-flight observation and science data analysis.
△ Less
Submitted 10 September, 2024; v1 submitted 15 January, 2024;
originally announced January 2024.
-
The Intrinsic Energy Resolution of LaBr$_3$(Ce) Crystal for GECAM
Authors:
Pei-Yi Feng,
Xi-Lei Sun,
Zheng-Hua An,
Cheng-Er Wang,
Da-Li Zhang,
Xin-Qiao Li,
Chao Zheng,
Shao-Lin Xiong,
Hong Lu
Abstract:
This study aims to provide an accurate estimation of the intrinsic resolution of LaBr$_3$(Ce) crystal through a combination of experimental and simulation methods. We re-analyzed the data from previous Wide-Angle Compton Coincidence (WACC) and Hard X-ray Calibration Facility (HXCF) experiments, conducted PMT Single-Photoelectron Calibration (SPEC) and radial non-uniformity (also called Spot Scanni…
▽ More
This study aims to provide an accurate estimation of the intrinsic resolution of LaBr$_3$(Ce) crystal through a combination of experimental and simulation methods. We re-analyzed the data from previous Wide-Angle Compton Coincidence (WACC) and Hard X-ray Calibration Facility (HXCF) experiments, conducted PMT Single-Photoelectron Calibration (SPEC) and radial non-uniformity (also called Spot Scanning, SS) experiments to acquire new data, and combined these results with Geant4 simulations to isolate the contribution of each physical process to the total energy resolution, thereby allowing for a precise estimation of the scintillator's intrinsic resolution. For 100 keV X-rays, the total energy resolution of LaBr$_3$(Ce) crystal is 3.99% $\pm$ 0.04% (expressed as 1-$σ$), with statistical fluctuations and intrinsic resolution as the main components, contributing 2.47% $\pm$ 0.00% and 3.06% $\pm$ 0.06%, respectively. We identify two main sources of intrinsic resolution: one primarily due to non-proportional scintillation, contributing 2.28% $\pm$ 0.00%, and the other due to fluctuations in the energy transfer process, contributing 2.04% $\pm$ 0.08%. We quantified six components of the total energy resolution and reconstructed the photon response using Geant4. The consistency between the reconstructed relative light yield and the experimental measurements validated the mass model of the LaBr$_3$(Ce) detector used in the simulations.
△ Less
Submitted 3 January, 2025; v1 submitted 30 December, 2023;
originally announced January 2024.
-
The Energy Response of LaBr3(Ce), LaBr3(Ce,Sr) and NaI(Tl) Crystals for GECAM
Authors:
Pei-Yi Feng,
Xi-Lei Sun,
Zheng-Hua An,
Yong Deng,
Cheng-Er Wang,
Huang Jiang,
Jun-Jie Li,
Da-Li Zhang,
Xin-Qiao Li,
Shao-Lin Xiong,
Chao Zheng,
Ke Gong,
Sheng Yang,
Xiao-Jing Liu,
Min Gao,
Xiang-Yang Wen,
Ya-Qing Liu,
Yan-Bing Xu,
Xiao-Yun Zhao,
Jia-Cong Liu,
Fan Zhang,
Hong Lu
Abstract:
The GECAM series of satellites utilize LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals as sensitive materials for gamma-ray detectors (GRDs). To investigate the non-linearity in the detection of low-energy gamma rays and address errors in the E-C relationship calibration, comprehensive tests and comparative studies of the non-linearity of these three crystals were conducted using Compton electrons,…
▽ More
The GECAM series of satellites utilize LaBr3(Ce), LaBr3(Ce,Sr), and NaI(Tl) crystals as sensitive materials for gamma-ray detectors (GRDs). To investigate the non-linearity in the detection of low-energy gamma rays and address errors in the E-C relationship calibration, comprehensive tests and comparative studies of the non-linearity of these three crystals were conducted using Compton electrons, radioactive sources, and mono-energetic X-rays. The non-linearity test results for Compton electrons and X-rays displayed substantial differences, with all three crystals showing higher non-linearity for X-rays and gamma-rays than for Compton electrons. Despite LaBr3(Ce) and LaBr3(Ce,Sr) crystals having higher absolute light yields, they exhibited a noticeable non-linear decrease in light yield, especially at energies below 400 keV. The NaI(Tl) crystal demonstrated excess light output in the 6~200 keV range, reaching a maximum excess of 9.2% at 30 keV in X-ray testing and up to 15.5% at 14 keV during Compton electron testing, indicating a significant advantage in the detection of low-energy gamma rays. Furthermore, this paper explores the underlying causes of the observed non-linearity in these crystals. This study not only elucidates the detector responses of GECAM, but also marks the inaugural comprehensive investigation into the non-linearity of domestically produced lanthanum bromide and sodium iodide crystals.
△ Less
Submitted 27 December, 2023;
originally announced December 2023.
-
Energy Response of GECAM Gamma-Ray Detector Based on LaBr3:Ce and SiPM Array
Authors:
Da-Li Zhang,
Xin-Qiao Li,
Shao-Lin Xiong,
Wen-xi Peng,
Fan-Zhang,
Yanguo-Li,
Zheng-Hua An,
Yan-Bing Xu,
Xi-Lei Sun,
Yue Zhu
Abstract:
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) , composed of two small satellites, is a new mission to monitor the Gamma-Ray Bursts (GRBs) coincident with Gravitational Wave (GW) events with a FOV of 100% all-sky.Each GECAM satellite detects and localizes GRBs using 25 compact and novel Gamma-Ray Detectors (GRDs) in 6 keV-5 MeV. Each GRD module is comprised…
▽ More
The Gravitational wave high-energy Electromagnetic Counterpart All-sky Monitor (GECAM) , composed of two small satellites, is a new mission to monitor the Gamma-Ray Bursts (GRBs) coincident with Gravitational Wave (GW) events with a FOV of 100% all-sky.Each GECAM satellite detects and localizes GRBs using 25 compact and novel Gamma-Ray Detectors (GRDs) in 6 keV-5 MeV. Each GRD module is comprised of LaBr3:Ce scintillator, SiPM array and preamplifier. A large dynamic range of GRD is achieved by the high gain and low gain channels of the preamplifier. The energy response of GRD prototype was evaluated using radioactive sources in the range of 5.9-1332.5 keV. A energy resolution of 5.3% at 662 keV was determined from the 137Cs pulse height spectra, which meets the GECAM requirement (< 8% at 662 keV). Energy to channel conversion was evaluated and a nonlinearity correction was performed to reduce the residuals (< 1.5%). Also, a Geant4-based simulated in-flight background and a measured GRD LaBr3:Ce intrinsic activity were used to evaluate the capability of in-flight calibration. These results demonstrate the design of GRD.
△ Less
Submitted 13 December, 2021; v1 submitted 10 April, 2018;
originally announced April 2018.
-
In-flight energy calibration of the space-borne Compton polarimeter POLAR
Authors:
Hualin Xiao,
Wojtek Hajdas,
Bobing Wu,
Nicolas Produit,
Jianchao Sun,
Merlin Kole,
Tianwei Bao,
Tancredi Bernasconi,
Tadeusz Batsch,
Franck Cadoux,
Junying Chai,
Yongwei Dong,
Ken Egli,
Neal Gauvin,
Minnan Kong,
Reinhold Kramert,
Siwei Kong,
Hancheng Li,
Lu Li,
Zhengheng Li,
Jiangtao Liu,
Xin Liu,
Radoslaw Marcinkowski,
Silvio Orsi,
Dominik K. Rybka
, et al. (17 additional authors not shown)
Abstract:
POLAR is a compact wide-field space-borne detector for precise measurements of the linear polarisation of hard X-rays emitted by transient sources in the energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of plastic scintillator bars used as a detection material. The bars are grouped in 25 detector modules. The energy range sensitivity of POLAR is optimized to match with the…
▽ More
POLAR is a compact wide-field space-borne detector for precise measurements of the linear polarisation of hard X-rays emitted by transient sources in the energy range from 50 keV to 500 keV. It consists of a 40$\times$40 array of plastic scintillator bars used as a detection material. The bars are grouped in 25 detector modules. The energy range sensitivity of POLAR is optimized to match with the prompt emission photons from the gamma-ray bursts (GRBs). Polarization measurements of the prompt emission would probe source geometries, emission mechanisms and magnetic structures in GRB jets. The instrument can also detect hard X-rays from solar flares and be used for precise measurement of their polarisation. POLAR was launched into a low Earth orbit on-board the Chinese space-lab TG-2 on September 15th, 2016. To achieve high accuracies in polarisation measurements it is essential to assure both before and during the flight a precise energy calibration. Such calibrations are performed with four low activity $^{22}$Na radioactive sources placed inside the instrument. Energy conversion factors are related to Compton edge positions from the collinear annihilation photons from the sources. This paper presents main principles of the in-flight calibration, describes studies of the method based on Monte Carlo simulations and its laboratory verification and finally provides some observation results based on the in-flight data analysis.
△ Less
Submitted 5 June, 2018; v1 submitted 24 October, 2017;
originally announced October 2017.
-
Calibration of the Space-borne Compton Polarimeter POLAR flight model with 100% polarized X-ray beams
Authors:
H. L. Xiao,
W. Hajdas,
P. Socha,
R. Marcinkowski,
B. B. Wu,
T. W. Bao,
J. Y. Chai,
Y. W. Dong,
M. N. Kong,
L. Li,
Z. H. Li,
J. T. Liu,
H. L. Shi,
L. M. Song,
J. C. Sun,
R. J. Wang,
Y. H. Wang,
X. Wen,
S. L. Xiong,
J. Zhang,
L. Y. Zhang,
S. N. Zhang,
X. F. Zhang,
Y. J. Zhang,
F. Cadoux
, et al. (10 additional authors not shown)
Abstract:
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays bea…
▽ More
POLAR is space-borne detector designed for a precise measurement of gamma-ray polarization of the prompt emissions of Gamma-Ray Bursts in the energy range 50 keV - 500 keV. POLAR is a compact Compton polarimeter consisting of 40$\times$ 40 plastic scintillator bars read out by 25 multi-anode PMTs. In May 2015, we performed a series of tests of the POLAR flight model with 100\% polarized x-rays beams at the European Synchrotron Radiation Facility beam-line ID11 aming to study thresholds, crosstalk between channels and responses of POLAR flight model to polarized X-ray beams. In this paper we present the data analysis method and some analysis results. According the results, POLAR FM has good polarimetric capabilities.
△ Less
Submitted 24 April, 2017; v1 submitted 20 April, 2017;
originally announced April 2017.