-
Image-current mediated sympathetic laser cooling of a single proton in a Penning trap down to 170 mK axial temperature
Authors:
C. Will,
M. Wiesinger,
P. Micke,
H. Yildiz,
T. Driscoll,
S. Kommu,
F. Abbass,
B. P. Arndt,
B. B. Bauer,
S. Erlewein,
M. Fleck,
J. I. Jäger,
B. M. Latacz,
A. Mooser,
D. Schweitzer,
G. Umbrazunas,
E. Wursten,
K. Blaum,
J. A. Devlin,
C. Ospelkaus,
W. Quint,
A. Soter,
J. Walz,
C. Smorra,
S. Ulmer
Abstract:
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a mileston…
▽ More
We demonstrate a new temperature record for image-current mediated sympathetic cooling of a single proton in a cryogenic Penning trap by laser-cooled $^9$Be$^+$. An axial mode temperature of 170 mK is reached, which is a 15-fold improvement compared to the previous best value. Our cooling technique is applicable to any charged particle, so that the measurements presented here constitute a milestone towards the next generation of high-precision Penning-trap measurements with exotic particles.
△ Less
Submitted 16 October, 2023;
originally announced October 2023.
-
Direct measurement of the $^3$He$^+$ magnetic moments
Authors:
A. Schneider,
B. Sikora,
S. Dickopf,
M. Müller,
N. S. Oreshkina,
A. Rischka,
I. A. Valuev,
S. Ulmer,
J. Walz,
Z. Harman,
C. H. Keitel,
A. Mooser,
K. Blaum
Abstract:
Helium-3 has nowadays become one of the most important candidates for studies in fundamental physics [1, 2, 3], nuclear and atomic structure [4, 5], magnetometry and metrology [6] as well as chemistry and medicine [7, 8]. In particular, $^3$He nuclear magnetic resonance (NMR) probes have been proposed as a new standard for absolute magnetometry [6, 9]. This requires a high-accuracy value for the…
▽ More
Helium-3 has nowadays become one of the most important candidates for studies in fundamental physics [1, 2, 3], nuclear and atomic structure [4, 5], magnetometry and metrology [6] as well as chemistry and medicine [7, 8]. In particular, $^3$He nuclear magnetic resonance (NMR) probes have been proposed as a new standard for absolute magnetometry [6, 9]. This requires a high-accuracy value for the $^3$He nuclear magnetic moment, which, however, has so far been determined only indirectly and with a relative precision of $12$ parts per billon (p.p.b.) [10,11]. Here we investigate the $^3$He$^+$ ground-state hyperfine structure in a Penning trap to directly measure the nuclear $g$-factor of $^3$He$^+$ $g'_I=-4.255\, 099\, 606\, 9(30)_{stat}(17)_{sys}$, the zero-field hyperfine splitting $E_{\rm HFS}^{\rm exp}=-8\, 665\, 649\, 865.77(26)_{stat}(1)_{sys}$ Hz and the bound electron $g$-factor $g_e^\text{exp}=-2.002\, 177\, 415\, 79(34)_{stat}(30)_{sys}$. The latter is consistent with our theoretical value $g_e^\text{theo}=-2.002\, 177\, 416\, 252\, 23(39)$ based on parameters and fundamental constants from [12]. Our measured value for the $^3$He$^+$ nuclear $g$-factor allows for the determination of the $g$-factor of the bare nucleus $g_I=-4.255\, 250\, 699\, 7(30)_{stat}(17)_{sys}(1)_{theo}$ via our accurate calculation of the diamagnetic shielding constant [13] $σ_{^3He^+}=0.000\,035\,507\,38(3)$. This constitutes the first direct calibration for $^3$He NMR probes and an improvement of the precision by one order of magnitude compared to previous indirect results. The measured zero-field hyperfine splitting improves the precision by two orders of magnitude compared to the previous most precise value [14] and enables us to determine the Zemach radius [15] to $r_Z=2.608(24)$ fm.
△ Less
Submitted 13 June, 2022;
originally announced June 2022.
-
Sympathetic cooling schemes for separately trapped ions coupled via image currents
Authors:
C. Will,
M. Bohman,
T. Driscoll,
M. Wiesinger,
F. Abbass,
M. J. Borchert,
J. A. Devlin,
S. Erlewein,
M. Fleck,
B. Latacz,
R. Moller,
A. Mooser,
D. Popper,
E. Wursten,
K. Blaum,
Y. Matsuda,
C. Ospelkaus,
W. Quint,
J. Walz,
C. Smorra,
S. Ulmer
Abstract:
Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the remote sympathetic cooling of a single proton with laser-cooled $^9$Be$^+$ in a double-Penning-trap system. We investigate three different cooling schemes and fin…
▽ More
Cooling of particles to mK-temperatures is essential for a variety of experiments with trapped charged particles. However, many species of interest lack suitable electronic transitions for direct laser cooling. We study theoretically the remote sympathetic cooling of a single proton with laser-cooled $^9$Be$^+$ in a double-Penning-trap system. We investigate three different cooling schemes and find, based on analytical calculations and numerical simulations, that two of them are capable of achieving proton temperatures of about 10 mK with cooling times on the order of 10 s. In contrast, established methods such as feedback-enhanced resistive cooling with image-current detectors are limited to about 1 K in 100 s. Since the studied techniques are applicable to any trapped charged particle and allow spatial separation between the target ion and the cooling species, they enable a variety of precision measurements based on trapped charged particles to be performed at improved sampling rates and with reduced systematic uncertainties.
△ Less
Submitted 9 December, 2021;
originally announced December 2021.
-
Physics at CERN's Antiproton Decelerator
Authors:
M. Hori,
J. Walz
Abstract:
The Antiproton Decelerator of CERN began operation in 1999 to serve experiments for studies of CPT invariance by precision laser and microwave spectroscopy of antihydrogen ($\bar{\rm H}$) and antiprotonic helium ($\bar{p}{\rm He}^+$). The first 12 years of operation saw cold $\bar{\rm H}$ synthesized by overlapping clouds of positrons ($e^+$) and antiprotons ($\bar{p}$) confined in magnetic Pennin…
▽ More
The Antiproton Decelerator of CERN began operation in 1999 to serve experiments for studies of CPT invariance by precision laser and microwave spectroscopy of antihydrogen ($\bar{\rm H}$) and antiprotonic helium ($\bar{p}{\rm He}^+$). The first 12 years of operation saw cold $\bar{\rm H}$ synthesized by overlapping clouds of positrons ($e^+$) and antiprotons ($\bar{p}$) confined in magnetic Penning traps. Cold $\bar{\rm H}$ was also produced in collisions between Rydberg positronium atoms and $\bar{p}$. Ground-state $\bar{\rm H}$ was later trapped for up to $\sim 1000$ s in a magnetic bottle trap, and microwave transitions excited between its hyperfine levels. In the $\bar{p}{\rm He}^+$ atom, UV transitions were measured to a precision of (2.3-5) $\times$ $10^{-9}$ by sub-Doppler two-photon laser spectroscopy. From this the antiproton-to-electron mass ratio was determined as $M_{\bar{p}}/m_e=$1836.1526736(23), which agrees with the p value. Microwave spectroscopy of $\bar{p}{\rm He}^+$ yielded a measurement of the $\bar{p}$ magnetic moment with a precision of 0.3%. More recently the magnetic moment of a single $\bar{p}$ confined in a Penning trap was measured with a higher precision, as $μ_{\bar{p}}=-2.792845(12)$$μ_{\rm nucl}$ in nuclear magnetons. Other measurements include the energy loss of 1-100 keV $\bar{p}$ traversing conductor and insulator targets; the cross sections of <10 keV $\bar{p}$ ionizing gas targets; and the cross sections of 5-MeV $\bar{p}$ annihilating on target foils via nuclear collisions. The biological effectiveness of $\bar{p}$ beams destroying cancer cells was measured as a possible method for radiological therapy. New experiments under preparation attempt to measure the gravitational acceleration of $\bar{\rm H}$ or synthesize $\obar{\rm H}^+$.
△ Less
Submitted 12 April, 2013;
originally announced April 2013.