The MAJORANA DEMONSTRATOR experiment's construction, commissioning, and performance
Authors:
N. Abgrall,
E. Aguayo,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
E. Blalock,
B. Bos,
M. Boswell,
A. W. Bradley,
V. Brudanin,
T. H. Burritt,
M. Busch,
M. Buuck,
D. Byram,
A. S. Caldwell,
T. S. Caldwell,
Y. -D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
D. C. Combs,
C. Cuesta
, et al. (86 additional authors not shown)
Abstract:
Background: The MAJORANA DEMONSTRATOR , a modular array of isotopically enriched high-purity germanium (HPGe) detectors, was constructed to demonstrate backgrounds low enough to justify building a tonne-scale experiment to search for the neutrinoless double-beta decay ($ββ(0ν)$) of $^{76}\mathrm{Ge}$. Purpose: This paper presents a description of the instrument, its commissioning, and operations.…
▽ More
Background: The MAJORANA DEMONSTRATOR , a modular array of isotopically enriched high-purity germanium (HPGe) detectors, was constructed to demonstrate backgrounds low enough to justify building a tonne-scale experiment to search for the neutrinoless double-beta decay ($ββ(0ν)$) of $^{76}\mathrm{Ge}$. Purpose: This paper presents a description of the instrument, its commissioning, and operations. It covers the electroforming, underground infrastructure, enrichment, detector fabrication, low-background and construction techniques, electronics, data acquisition, databases, and data processing of the MAJORANA DEMONSTRATOR. Method: The MAJORANA DEMONSTRATOR operated inside an ultra-low radioactivity passive shield at the 4850-foot~level of the Sanford Underground Research Facility (SURF) from 2015-2021. Results and Conclusions: The MAJORANA DEMONSTRATOR achieved the best energy resolution and second-best background level of any $ββ(0ν)$ search. This enabled it to achieve an ultimate half-life limit on $ββ(0ν)$ in $^{76}\mathrm{Ge}$ of $8.3\times 10^{25}$~yr (90\% C.L.) and perform a rich set of searches for other physics beyond the Standard Model.
△ Less
Submitted 3 January, 2025;
originally announced January 2025.
-
The fixed probe storage ring magnetometer for the Muon g-2 experiment at Fermi National Accelerator Laboratory
Authors:
Erik Swanson,
Martin Fertl,
Alejandro Garcia,
Cole Helling,
Ronaldo Ortez,
Rachel Osofsky,
David A. Peterson,
Rene Reimann,
Matthias W. Smith,
Tim D. Van Wechel
Abstract:
The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the Universit…
▽ More
The goal of the FNAL E989 experiment is to measure the muon magnetic anomaly to unprecedented accuracy and precision at the Fermi National Accelerator Laboratory. To meet this goal, the time and space averaged magnetic environment in the muon storage volume must be known to better than 70 ppb. A new pulsed proton nuclear magnetic resonance (NMR) magnetometer was designed and built at the University of Washington, Seattle to track the temporal stability of the 1.45T magnetic field in the muon storage ring at this precision. It consists of an array of 378 petroleum jelly based NMR probes that are embedded in the walls of muon storage ring vacuum chambers and custom electronics built with readily available modular radio frequency (RF) components. We give NMR probe construction details and describe the functions of the custom electronic subsystems. The excellent performance metrics of the magnetometer are discussed, where after 8 years of operation the median single shot resolution of the array of probes remains at 650 ppb.
△ Less
Submitted 7 January, 2025; v1 submitted 10 October, 2024;
originally announced October 2024.
-
The MAJORANA DEMONSTRATOR Readout Electronics System
Authors:
N. Abgrall,
M. Amman,
I. J. Arnquist,
F. T. Avignone III,
A. S. Barabash,
C. J. Barton,
P. J. Barton,
F. E. Bertrand,
K. H. Bhimani,
B. Bos,
A. W. Bradley,
T. H. Burritt,
M. Busch,
M. Buuck,
T. S. Caldwell,
Y-D. Chan,
C. D. Christofferson,
P. -H. Chu,
M. L. Clark,
R. J. Cooper,
C. Cuesta,
J. A. Detwiler,
A. Drobizhev,
D. W. Edwins,
Yu. Efremenko
, et al. (54 additional authors not shown)
Abstract:
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper prov…
▽ More
The MAJORANA DEMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76-Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the MAJORANA DEMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.
△ Less
Submitted 23 February, 2022; v1 submitted 17 November, 2021;
originally announced November 2021.
-
Beta decay of molecular tritium
Authors:
Y. -T. Lin,
T. H. Burritt,
C. Claessens,
G. Holman,
M. Kallander,
E. Machado,
L. I. Minter,
R. Ostertag,
D. S. Parno,
J. Pedersen,
D. A. Peterson,
R. G. H. Robertson,
E. B. Smith,
T. D. Van Wechel,
A. P. Vizcaya Hernández
Abstract:
The beta decay of tritium in the form of molecular TT is the basis of sensitive experiments to measure neutrino mass. The final-state electronic, vibrational, and rotational excitations modify the beta spectrum significantly, and are obtained from theory. We report measurements of the branching ratios to specific ionization states for the isotopolog HT. Two earlier, concordant measurements gave br…
▽ More
The beta decay of tritium in the form of molecular TT is the basis of sensitive experiments to measure neutrino mass. The final-state electronic, vibrational, and rotational excitations modify the beta spectrum significantly, and are obtained from theory. We report measurements of the branching ratios to specific ionization states for the isotopolog HT. Two earlier, concordant measurements gave branching ratios of HT to the bound HHe$^+$ ion of 89.5% and 93.2%, in sharp disagreement with the theoretical prediction of 55-57%, raising concerns about the theory's reliability in neutrino mass experiments. Our result, 56.5(6)%, is compatible with the theoretical expectation and disagrees strongly with the previous measurements.
△ Less
Submitted 24 May, 2020; v1 submitted 31 January, 2020;
originally announced January 2020.
-
Focal-plane detector system for the KATRIN experiment
Authors:
J. F. Amsbaugh,
J. Barrett,
A. Beglarian,
T. Bergmann,
H. Bichsel,
L. I. Bodine,
J. Bonn,
N. M. Boyd,
T. H. Burritt,
Z. Chaoui,
S. Chilingaryan,
T. J. Corona,
P. J. Doe,
J. A. Dunmore,
S. Enomoto,
J. Fischer,
J. A. Formaggio,
F. M. Fränkle,
D. Furse,
H. Gemmeke,
F. Glück,
F. Harms,
G. C. Harper,
J. Hartmann,
M. A. Howe
, et al. (26 additional authors not shown)
Abstract:
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electro…
▽ More
The focal-plane detector system for the KArlsruhe TRItium Neutrino (KATRIN) experiment consists of a multi-pixel silicon p-i-n-diode array, custom readout electronics, two superconducting solenoid magnets, an ultra high-vacuum system, a high-vacuum system, calibration and monitoring devices, a scintillating veto, and a custom data-acquisition system. It is designed to detect the low-energy electrons selected by the KATRIN main spectrometer. We describe the system and summarize its performance after its final installation.
△ Less
Submitted 28 January, 2015; v1 submitted 10 April, 2014;
originally announced April 2014.
-
Dead layer on silicon p-i-n diode charged-particle detectors
Authors:
B. L. Wall,
J. F. Amsbaugh,
A. Beglarian,
T. Bergmann,
H. C. Bichsel,
L. I. Bodine,
N. M. Boyd,
T. H. Burritt,
Z. Chaoui,
T. J. Corona,
P. J. Doe,
S. Enomoto,
F. Harms,
G. C. Harper,
M. A. Howe,
E. L. Martin,
D. S. Parno,
D. A. Peterson,
L. Petzold,
P. Renschler,
R. G. H. Robertson,
J. Schwarz,
M. Steidl,
T. D. Van Wechel,
B. A. VanDevender
, et al. (3 additional authors not shown)
Abstract:
Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-…
▽ More
Semiconductor detectors in general have a dead layer at their surfaces that is either a result of natural or induced passivation, or is formed during the process of making a contact. Charged particles passing through this region produce ionization that is incompletely collected and recorded, which leads to departures from the ideal in both energy deposition and resolution. The silicon \textit{p-i-n} diode used in the KATRIN neutrino-mass experiment has such a dead layer. We have constructed a detailed Monte Carlo model for the passage of electrons from vacuum into a silicon detector, and compared the measured energy spectra to the predicted ones for a range of energies from 12 to 20 keV. The comparison provides experimental evidence that a substantial fraction of the ionization produced in the "dead" layer evidently escapes by diffusion, with 46% being collected in the depletion zone and the balance being neutralized at the contact or by bulk recombination. The most elementary model of a thinner dead layer from which no charge is collected is strongly disfavored.
△ Less
Submitted 7 October, 2013; v1 submitted 4 October, 2013;
originally announced October 2013.
-
Performance of a TiN-coated monolithic silicon pin-diode array under mechanical stress
Authors:
B. A. VanDevender,
L. I. Bodine,
A. W. Myers,
J. F. Amsbaugh,
M. A. Howe,
M. L. Leber,
R. G. H. Robertson,
K. Tolich,
T. D. Van Wechel,
B. L. Wall
Abstract:
The Karlsruhe Tritium Neutrino Experiment (KATRIN) will detect tritium beta- decay electrons that pass through its electromagnetic spectrometer with a highly- segmented monolithic silicon pin-diode focal-plane detector (FPD). This pin-diode array will be on a single piece of 500-μm-thick silicon, with contact between titanium nitride (TiN) coated detector pixels and front-end electronics made by s…
▽ More
The Karlsruhe Tritium Neutrino Experiment (KATRIN) will detect tritium beta- decay electrons that pass through its electromagnetic spectrometer with a highly- segmented monolithic silicon pin-diode focal-plane detector (FPD). This pin-diode array will be on a single piece of 500-μm-thick silicon, with contact between titanium nitride (TiN) coated detector pixels and front-end electronics made by spring-loaded pogo pins. The pogo pins will exert a total force of up to 50N on the detector, deforming it and resulting in mechanical stress up to 50 MPa in the silicon bulk. We have evaluated a prototype pin-diode array with a pogo-pin connection scheme similar to the KATRIN FPD. We find that pogo pins make good electrical contact to TiN and observe no effects on detector resolution or reverse-bias leakage current which can be attributed to mechanical stress.
△ Less
Submitted 1 February, 2012;
originally announced February 2012.
-
Four methods for determining the composition of trace radioactive surface contamination of low-radioactivity metal
Authors:
H. M. O'Keeffe,
T. H. Burritt,
B. T. Cleveland,
G. Doucas,
N. Gagnon,
N. A. Jelley,
C. Kraus,
I. T. Lawson,
S. Majerus,
S. R. McGee,
A. W. Myers,
A. W. P. Poon,
K. Rielage,
R. G. H. Robertson,
R. C. Rosten,
L. C. Stonehill,
B. A. VanDevender,
T. D. Van Wechel
Abstract:
Four methods for determining the composition of low-level uranium- and thorium-chain surface contamination are presented. One method is the observation of Cherenkov light production in water. In two additional methods a position-sensitive proportional counter surrounding the surface is used to make both a measurement of the energy spectrum of alpha particle emissions and also coincidence measureme…
▽ More
Four methods for determining the composition of low-level uranium- and thorium-chain surface contamination are presented. One method is the observation of Cherenkov light production in water. In two additional methods a position-sensitive proportional counter surrounding the surface is used to make both a measurement of the energy spectrum of alpha particle emissions and also coincidence measurements to derive the thorium-chain content based on the presence of short-lived isotopes in that decay chain. The fourth method is a radiochemical technique in which the surface is eluted with a weak acid, the eluate is concentrated, added to liquid scintillator and assayed by recording beta-alpha coincidences. These methods were used to characterize two `hotspots' on the outer surface of one of the He-3 proportional counters in the Neutral Current Detection array of the Sudbury Neutrino Observatory experiment. The methods have similar sensitivities, of order tens of ng, to both thorium- and uranium-chain contamination.
△ Less
Submitted 29 March, 2011;
originally announced March 2011.
-
Astroparticle Physics with a Customized Low-Background Broad Energy Germanium Detector
Authors:
MAJORANA Collaboration,
C. E. Aalseth,
M. Amman,
F. T. Avignone III,
H. O. Back,
A. S. Barabash,
P. S. Barbeau,
M. Bergevin,
F. E. Bertrand,
M. Boswell,
V. Brudanin,
W. Bugg,
T. H. Burritt,
M. Busch,
G. Capps,
Y-D. Chan,
J. I. Collar,
R. J. Cooper,
R. Creswick,
J. A. Detwiler,
J. Diaz,
P. J. Doe,
Yu. Efremenko,
V. Egorov,
H. Ejiri
, et al. (78 additional authors not shown)
Abstract:
The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in t…
▽ More
The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c^2 mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the MAJORANA Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.
△ Less
Submitted 20 July, 2010; v1 submitted 19 July, 2010;
originally announced July 2010.
-
An array of low-background $^3$He proportional counters for the Sudbury Neutrino Observatory
Authors:
J. F. Amsbaugh,
J. M. Anaya,
J. Banar,
T. J. Bowles,
M. C. Browne,
T. V. Bullard,
T. H. Burritt,
G. A. Cox-Mobrand,
X. Dai,
H. Deng,
M. Di Marco,
P. J. Doe,
M. R. Dragowsky,
C. A. Duba,
F. A. Duncan,
E. D. Earle,
S. R. Elliott,
E. -I. Esch,
H. Fergani,
J. A. Formaggio,
M. M. Fowler,
J. E. Franklin,
P. Geissbühler,
J. V. Germani,
A. Goldschmidt
, et al. (49 additional authors not shown)
Abstract:
An array of Neutral-Current Detectors (NCDs) has been built in order to make a unique measurement of the total active flux of solar neutrinos in the Sudbury Neutrino Observatory (SNO). Data in the third phase of the SNO experiment were collected between November 2004 and November 2006, after the NCD array was added to improve the neutral-current sensitivity of the SNO detector. This array consis…
▽ More
An array of Neutral-Current Detectors (NCDs) has been built in order to make a unique measurement of the total active flux of solar neutrinos in the Sudbury Neutrino Observatory (SNO). Data in the third phase of the SNO experiment were collected between November 2004 and November 2006, after the NCD array was added to improve the neutral-current sensitivity of the SNO detector. This array consisted of 36 strings of proportional counters filled with a mixture of $^3$He and CF$_4$ gas capable of detecting the neutrons liberated by the neutrino-deuteron neutral current reaction in the D$_2$O, and four strings filled with a mixture of $^4$He and CF$_4$ gas for background measurements. The proportional counter diameter is 5 cm. The total deployed array length was 398 m. The SNO NCD array is the lowest-radioactivity large array of proportional counters ever produced. This article describes the design, construction, deployment, and characterization of the NCD array, discusses the electronics and data acquisition system, and considers event signatures and backgrounds.
△ Less
Submitted 23 May, 2007;
originally announced May 2007.