neuSIM4: A comprehensive GEANT4 based neutron simulation code
Authors:
J. Park,
F. C. E. Teh,
M. B. Tsang,
K. W. Brown,
Z. Chajecki,
B. Hong,
T. Lokotko,
W. G. Lynch,
J. Wieske,
K. Zhu
Abstract:
A new neutron SIMulation program based on the versatile GEANT4 toolkit, neuSIM4, has been developed to describe interactions of neutrons in the NE213 liquid scintillator from 0.1 to 3000 MeV. neuSIM4 is designed to accommodate complicated modern detector geometry setups with multiple scintillator detectors, each of which can be outfitted with more than one photo-multiplier. To address a broad spec…
▽ More
A new neutron SIMulation program based on the versatile GEANT4 toolkit, neuSIM4, has been developed to describe interactions of neutrons in the NE213 liquid scintillator from 0.1 to 3000 MeV. neuSIM4 is designed to accommodate complicated modern detector geometry setups with multiple scintillator detectors, each of which can be outfitted with more than one photo-multiplier. To address a broad spectrum of neutron energies, two new neutron interaction physics models, KSCIN and NxQMD, have been implemented in GEANT4. For neutrons with energy below 110 MeV, we incorporate a total of eleven neutron induced reaction channels on hydrogen and carbon nuclei, including nine carbon inelastic reaction channels, into KSCIN. Beyond 110 MeV, we implement a neutron induced reaction model, NxQMD, in GEANT4. We use its results as reference to evaluate other neutron-interaction physics models in GEANT4. We find that results from an existing cascade physics model (INCL) in GEANT4 agree very well with the results from NxQMD, and results from both codes agree with new and existing light response data. To connect KSCIN to NxQMD or INCL, we introduce a transition region where the contribution of neuSIM4 linearly decreases with corresponding increased contributions from NxQMD or INCL. To demonstrate the application of the new code, we simulate the light response and performance of a 2 x 2 m2 neutron detector wall array consisting of 25 2m-long scintillation bars. We are able to compare the predicted light response functions to the shape of the experimental response functions and calculate the efficiency of the neutron detector array for neutron energies up to 200 MeV. These simulation results will be pivotal for understanding the performance of modern neutron arrays with intricate geometries, especially in the measurements of neutron energy spectra in heavy-ion reactions.
△ Less
Submitted 3 June, 2024;
originally announced June 2024.
-
Reaction Losses of Charged Particles in CsI(Tl) crystals
Authors:
S. Sweany,
W. G. Lynch,
K. Brown,
A. Anthony,
Z. Chajecki,
D. Dell'Aquila,
P. Morfouace,
F. C. E. Teh,
C. Y. Tsang,
M. B. Tsang,
R. S. Wang,
K. Zhu
Abstract:
To efficiently detect energetic light charged particles, it is common to use arrays of energy-loss telescopes involving two or more layers of detection media. As the energy of the particles increases, thicker layers are usually needed. However, carrying out measurements with thick-telescopes may require corrections for the losses due to nuclear reactions induced by the incident particles on nuclei…
▽ More
To efficiently detect energetic light charged particles, it is common to use arrays of energy-loss telescopes involving two or more layers of detection media. As the energy of the particles increases, thicker layers are usually needed. However, carrying out measurements with thick-telescopes may require corrections for the losses due to nuclear reactions induced by the incident particles on nuclei within the detector and for the scattering of incident particles out of the detector, without depositing their full energy in the active material. In this paper, we develop a method for measuring such corrections and determine the reaction and out-scattering losses for data measured with the silicon-CsI(Tl) telescopes of the newly developed HiRA10 array. The extracted efficiencies are in good agreement with model predictions using the GEANT4 reaction loss algorithm for Z=1 and Z=2 isotopes. After correcting for the HiRA10 geometry, a general function that describes the efficiencies from the reaction loss in CsI(Tl) crystals as a function of range is obtained.
△ Less
Submitted 27 July, 2021;
originally announced July 2021.
-
Beam Particle Identification and Tagging of Incompletely Stripped Heavy Beams with HEIST
Authors:
A. K. Anthony,
C. Y. Niu,
R. S. Wang,
J. Wieske,
K. W. Brown,
Z. Chajecki,
W. G. Lynch,
Y. Ayyad,
J. Barney,
T. Baumann,
D. Bazin,
S. Beceiro-Novo,
J. Boza,
J. Chen,
K. J. Cook,
M. Cortesi,
T. Ginter,
W. Mittig,
A. Pype,
M. K. Smith,
C. Soto,
C. Sumithrarachchi,
J. Swaim,
S. Sweany,
F. C. E. Teh
, et al. (4 additional authors not shown)
Abstract:
A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST utilizes two micro-channel plate timing detectors to measure time of flight, a multi-sampling ion chamber to measure energy loss, and a high purity Ge detector to i…
▽ More
A challenge preventing successful inverse kinematics measurements with heavy nuclei that are not fully stripped is identifying and tagging the beam particles. For this purpose, the HEavy ISotope Tagger (HEIST) has been developed. HEIST utilizes two micro-channel plate timing detectors to measure time of flight, a multi-sampling ion chamber to measure energy loss, and a high purity Ge detector to identify isomer decays and calibrate the isotope identification system. HEIST has successfully identified $^{198}$Pb and other nearby nuclei at energies of about 75 MeV/A. In the experiment discussed, a typical cut containing 89\% of all $^{198}$Pb$^{+80}$ in the beam had a purity of 86\%. We examine the issues of charge state contamination. The observed charge state populations of these ions are presented and are moderately well described by the charge state model GLOBAL.
△ Less
Submitted 23 August, 2021; v1 submitted 28 July, 2021;
originally announced July 2021.
-
Non-linearity effects on the light-output calibration of light charged particles in CsI(Tl) scintillator crystals
Authors:
D. Dell'Aquila,
S. Sweany,
K. W. Brown,
Z. Chajecki,
W. G. Lynch,
F. C. E. Teh,
C. -Y. Tsang,
M. B. Tsang,
K. Zhu,
C. Anderson,
A. Anthony,
S. Barlini,
J. Barney,
A. Camaiani,
G. Jhang,
J. Crosby,
J. Estee,
M. Ghazali,
F. Guan,
O. Khanal,
S. Kodali,
I. Lombardo,
J. Manfredi,
L. Morelli,
P. Morfouace
, et al. (2 additional authors not shown)
Abstract:
The light output produced by light ions (Z<=4) in CsI(Tl) crystals is studied over a wide range of detected energies (E<=300 MeV). Energy-light calibration data sets are obtained with the 10 cm crystals in the recently upgraded High-Resolution Array (HiRA10). We use proton recoil data from 40,48Ca + CH2 at 28 MeV/u, 56.6 MeV/u, 39 MeV/u and 139.8 MeV/u and data from a dedicated experiment with dir…
▽ More
The light output produced by light ions (Z<=4) in CsI(Tl) crystals is studied over a wide range of detected energies (E<=300 MeV). Energy-light calibration data sets are obtained with the 10 cm crystals in the recently upgraded High-Resolution Array (HiRA10). We use proton recoil data from 40,48Ca + CH2 at 28 MeV/u, 56.6 MeV/u, 39 MeV/u and 139.8 MeV/u and data from a dedicated experiment with direct low-energy beams. We also use the punch through points of p, d, and t particles from 40,48Ca + 58,64Ni, 112,124Sn collisions reactions at 139.8 MeV/u. Non-linearities, arising in particular from Tl doping and light collection efficiency in the CsI crystals, are found to significantly affect the light output and therefore the calibration of the detector response for light charged particles, especially the hydrogen isotopes. A new empirical parametrization of the hydrogen light output, L(E,Z=1,A), is proposed to account for the observed effects. Results are found to be consistent for all 48 CsI(Tl) crystals in a cluster of 12 HiRA10 telescopes.
△ Less
Submitted 21 March, 2019; v1 submitted 18 February, 2019;
originally announced February 2019.
-
Constraint on the Ground-state Mass of 21Al and Three-Nucleon Forces
Authors:
X. Z. Teng,
C. E. Teh,
J. Lee,
X. X. Xu,
C. J. Lin,
L. J. Sun,
J. S. Wang,
D. Q. Fang,
S. Leblond,
Z. H. Li,
J. Li,
N. R. Ma,
J. B. Ma,
H. L. Zang,
P. Ma,
S. L. Jin,
M. R. Huang,
Z. Bai,
J. J. Liu,
T. Lokotko,
F. Yang,
H. M. Jia,
D. X. Wang,
Y. Y. Yang,
Z. G. Hu
, et al. (2 additional authors not shown)
Abstract:
Fragmentation cross section of $^{28}$Si + $^{9}$Be reaction at 75.8 MeV/u was analyzed for studying the decay mode of single-proton emission in $^{21}$Al (the proton-rich nucleus with neutron closed-shell of $N = 8$ and $T_z = -5/2$). With the comparison between the measured fragmentation cross section and the theoretical cross section produced by EPAX3.1a for the observed nuclei (i.e. $^{20}$Mg,…
▽ More
Fragmentation cross section of $^{28}$Si + $^{9}$Be reaction at 75.8 MeV/u was analyzed for studying the decay mode of single-proton emission in $^{21}$Al (the proton-rich nucleus with neutron closed-shell of $N = 8$ and $T_z = -5/2$). With the comparison between the measured fragmentation cross section and the theoretical cross section produced by EPAX3.1a for the observed nuclei (i.e. $^{20}$Mg, $^{21}$Al and $^{22}$Si), the expected yield for a particle stable $^{21}$Al was estimated. With the exponential decay law, an upper limit of half-life of $13$ ns was determined. Using the single-proton penetration model, the upper limit of single-proton separation energy of $-105$ keV was deduced. This deduced mass limit agrees with the microscopic calculation based on nucleon-nucleon (NN) + three-nucleon (3N) forces in $sdf_{7/2}p_{3/2}$ valence space, which indicates the importance of 3N forces in $^{21}$Al.
△ Less
Submitted 19 April, 2017; v1 submitted 11 April, 2017;
originally announced April 2017.