-
The Systematics and Operational Studies (SOS) Apparatus as a testbed for nEDM@SNS experiment
Authors:
V. Cianciolo,
R. Golub,
B. W. Filippone,
P. R. Huffman,
K. Leung,
E. Korobkina,
C. Swank
Abstract:
The nEDM experiment at the SNS (nEDM@SNS) is the first measurement of the neutron EDM to directly measure the precession frequency of the neutron spin due to magnetic and electric fields. Previous measurements have inferred the precession frequency by measuring the residual polarization of neutrons after a long period of free precession. This difference provides independent information on potentia…
▽ More
The nEDM experiment at the SNS (nEDM@SNS) is the first measurement of the neutron EDM to directly measure the precession frequency of the neutron spin due to magnetic and electric fields. Previous measurements have inferred the precession frequency by measuring the residual polarization of neutrons after a long period of free precession. This difference provides independent information on potential unknown systematic uncertainties compared to previous and on-going measurements. It is precisely because nEDM@SNS is using a number of novel techniques, that it is essential to perform detailed studies of these techniques in order to optimize the statistical sensitivity and minimize the systematic uncertainty. The Systematic and Operational Studies Apparatus (SOSA) was one of the main efforts of nEDM@SNS collaboration, concentrated on development of a cryogenic test-bed for learning precise manipulation of spins and studing systematic effects of the proposed new technique. The test bed does not need an electric field but designed to have full NMR capability to the same level as nEDM@SNS.
△ Less
Submitted 6 January, 2025; v1 submitted 31 October, 2024;
originally announced November 2024.
-
Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap
Authors:
C. Cude-Woods,
F. M. Gonzalez,
E. M. Fries,
T. Bailey,
M. Blatnik,
N. B. Callahan,
J. H. Choi,
S. M. Clayton,
S. A. Currie,
M. Dawid,
B. W. Filippone,
W. Fox,
P. Geltenbort,
E. George,
L. Hayen,
K. P. Hickerson,
M. A. Hoffbauer,
K. Hoffman,
A. T. Holley,
T. M. Ito,
A. Komives,
C. -Y. Liu,
M. Makela,
C. L. Morris,
R. Musedinovic
, et al. (17 additional authors not shown)
Abstract:
The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for inve…
▽ More
The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.
△ Less
Submitted 4 May, 2022;
originally announced May 2022.
-
Quantum Control of Two Critically Dressed Spin 1/2 Species in Magnetic Fluctuations
Authors:
Raymond Tat,
Christopher Swank
Abstract:
The neutron electric dipole moment experiment at the Spallation Neutron Source (nEDM@SNS experiment) proposes to measure the nEDM using the spin-dependent capture cross section of neutrons on $^3$He. The critical dressing mode of this experiment uses an oscillating magnetic field to dress the gyromagnetic ratios of neutrons and $^3$He to the same value. While this technique grants increased sensit…
▽ More
The neutron electric dipole moment experiment at the Spallation Neutron Source (nEDM@SNS experiment) proposes to measure the nEDM using the spin-dependent capture cross section of neutrons on $^3$He. The critical dressing mode of this experiment uses an oscillating magnetic field to dress the gyromagnetic ratios of neutrons and $^3$He to the same value. While this technique grants increased sensitivity to the nEDM by improving the signal-to-noise ratio, this mode of measurement also introduces additional noise from the power supply used to drive the dressing field. This can lead to randomly fluctuating magnetic fields which cause the spins of neutrons and $^3$He to drift apart over time. Here we use second-order time-dependent perturbation theory to compute relaxation and frequency shifts due to fluctuations in the dressing field in terms of the magnetic field noise power spectrum and compare these calculations to numerical solutions obtained by integrating the Bloch equations. We then use these results to develop mitigation strategies for this type of noise. Furthermore, we report on spin dressing modulation techniques that significantly amplify coherence times for the critically dressed system, and attempt to quantify the coherence time achievable.
△ Less
Submitted 3 December, 2021;
originally announced December 2021.
-
Improved neutron lifetime measurement with UCN$τ$
Authors:
F. M. Gonzalez,
E. M. Fries,
C. Cude-Woods,
T. Bailey,
M. Blatnik,
L. J. Broussard,
N. B. Callahan,
J. H. Choi,
S. M. Clayton,
S. A. Currie,
M. Dawid,
E. B. Dees,
B. W. Filippone,
W. Fox,
P. Geltenbort,
E. George,
L. Hayen,
K. P. Hickerson,
M. A. Hoffbauer,
K. Hoffman,
A. T. Holley,
T. M. Ito,
A. Komives,
C. -Y. Liu,
M. Makela
, et al. (19 additional authors not shown)
Abstract:
We report an improved measurement of the free neutron lifetime $τ_{n}$ using the UCN$τ$ apparatus at the Los Alamos Neutron Science Center. We counted a total of approximately $38\times10^{6}$ surviving ultracold neutrons (UCN) after storing in UCN$τ$'s magneto-gravitational trap over two data acquisition campaigns in 2017 and 2018. We extract $τ_{n}$ from three blinded, independent analyses by bo…
▽ More
We report an improved measurement of the free neutron lifetime $τ_{n}$ using the UCN$τ$ apparatus at the Los Alamos Neutron Science Center. We counted a total of approximately $38\times10^{6}$ surviving ultracold neutrons (UCN) after storing in UCN$τ$'s magneto-gravitational trap over two data acquisition campaigns in 2017 and 2018. We extract $τ_{n}$ from three blinded, independent analyses by both pairing long and short storage-time runs to find a set of replicate $τ_{n}$ measurements and by performing a global likelihood fit to all data while self-consistently incorporating the $β$-decay lifetime. Both techniques achieve consistent results and find a value $τ_{n}=877.75\pm0.28_{\text{ stat}}+0.22/-0.16_{\text{ syst}}$~s. With this sensitivity, neutron lifetime experiments now directly address the impact of recent refinements in our understanding of the standard model for neutron decay.
△ Less
Submitted 21 September, 2021; v1 submitted 18 June, 2021;
originally announced June 2021.
-
Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment
Authors:
Xuan Sun,
E. Adamek,
B. Allgeier,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
A. T. Holley,
T. M. Ito,
A. Knecht
, et al. (34 additional authors not shown)
Abstract:
The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sens…
▽ More
The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to $b_{n}$, the Fierz interference term in the neutron $β$-decay rate. In this work, we determine $b_{n}$ from the energy dependence of $A_0$ using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 $A$ dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new $b_{n}$ measurement using the weighted average of our asymmetry dataset fits, to obtain $b_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}}$ which corresponds to a limit of $-0.012 < b_{n} < 0.144$ at the 90% confidence level.
△ Less
Submitted 13 November, 2019;
originally announced November 2019.
-
A New Cryogenic Apparatus to Search for the Neutron Electric Dipole Moment
Authors:
M. W. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baessler,
L. Barron-Palos,
L. M. Bartoszek,
D. H. Beck,
M. Behzadipour,
I. Berkutov,
J. Bessuille,
M. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta,
Y. Efremenko
, et al. (69 additional authors not shown)
Abstract:
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallati…
▽ More
A cryogenic apparatus is described that enables a new experiment, nEDM@SNS, with a major improvement in sensitivity compared to the existing limit in the search for a neutron Electric Dipole Moment (EDM). It uses superfluid $^4$He to produce a high density of Ultra-Cold Neutrons (UCN) which are contained in a suitably coated pair of measurement cells. The experiment, to be operated at the Spallation Neutron Source at Oak Ridge National Laboratory, uses polarized $^3$He from an Atomic Beam Source injected into the superfluid $^4$He and transported to the measurement cells as a co-magnetometer. The superfluid $^4$He is also used as an insulating medium allowing significantly higher electric fields, compared to previous experiments, to be maintained across the measurement cells. These features provide an ultimate statistical uncertainty for the EDM of $2-3\times 10^{-28}$ e-cm, with anticipated systematic uncertainties below this level.
△ Less
Submitted 20 November, 2019; v1 submitted 26 August, 2019;
originally announced August 2019.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
The neutron electric dipole moment experiment at the Spallation Neutron Source
Authors:
K. K. H. Leung,
M. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
L. Barrón-Palos,
L. Bartoszek,
D. H. Beck,
M. Behzadipour,
J. Bessuille,
M. A. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
P. -H. Chu,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta
, et al. (68 additional authors not shown)
Abstract:
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarize…
▽ More
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.
△ Less
Submitted 4 October, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
Search for dark matter decay of the free neutron from the UCNA experiment: n $\rightarrow χ+ e^+e^-$
Authors:
X. Sun,
E. Adamek,
B. Allgeier,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
G. E. Hogan,
A. T. Holley,
T. M. Ito,
A. Knecht,
C. -Y. Liu
, et al. (35 additional authors not shown)
Abstract:
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) exper…
▽ More
It has been proposed recently that a previously unobserved neutron decay branch to a dark matter particle ($χ$) could account for the discrepancy in the neutron lifetime observed in experiments that use two different measurement techniques. One of the possible final states discussed includes a single $χ$ along with an $e^{+}e^{-}$ pair. We use data from the UCNA (Ultracold Neutron Asymmetry) experiment to set limits on this decay channel. Coincident electron-like events are detected with $\sim 4π$ acceptance using a pair of detectors that observe a volume of stored Ultracold Neutrons (UCNs). The summed kinetic energy ($E_{e^{+}e^{-}}$) from such events is used to set limits, as a function of the $χ$ mass, on the branching fraction for this decay channel. For $χ$ masses consistent with resolving the neutron lifetime discrepancy, we exclude this as the dominant dark matter decay channel at $\gg~5σ$ level for $100~\text{keV} < E_{e^{+}e^{-}} < 644~\text{keV}$. If the $χ+e^{+}e^{-}$ final state is not the only one, we set limits on its branching fraction of $< 10^{-4}$ for the above $E_{e^{+}e^{-}}$ range at $> 90\%$ confidence level.
△ Less
Submitted 28 March, 2018;
originally announced March 2018.
-
New result for the neutron $β$-asymmetry parameter $A_0$ from UCNA
Authors:
M. A. -P. Brown,
E. B. Dees,
E. Adamek,
B. Allgeier,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
X. Ding,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
G. E. Hogan,
A. T. Holley,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. Liu
, et al. (34 additional authors not shown)
Abstract:
The neutron $β$-decay asymmetry parameter $A_0$ defines the correlation between the spin of the neutron and the momentum of the emitted electron, which determines $λ=\frac{g_{A}}{g_{V}}$, the ratio of the axial-vector to vector weak coupling constants. The UCNA Experiment, located at the Ultracold Neutron facility at the Los Alamos Neutron Science Center, is the first to measure such a correlation…
▽ More
The neutron $β$-decay asymmetry parameter $A_0$ defines the correlation between the spin of the neutron and the momentum of the emitted electron, which determines $λ=\frac{g_{A}}{g_{V}}$, the ratio of the axial-vector to vector weak coupling constants. The UCNA Experiment, located at the Ultracold Neutron facility at the Los Alamos Neutron Science Center, is the first to measure such a correlation coefficient using ultracold neutrons (UCN). Following improvements to the systematic uncertainties and increased statistics, we report the new result $A_0 = -0.12054(44)_{\mathrm{stat}}(68)_{\mathrm{syst}}$ which yields $λ\equiv \frac{g_{A}}{g_{V}}=-1.2783(22)$. Combination with the previous UCNA result and accounting for correlated systematic uncertainties produces $A_0=-0.12015(34)_{\mathrm{stat}}(63)_{\mathrm{syst}}$ and $λ\equiv \frac{g_{A}}{g_{V}}=-1.2772(20)$.
△ Less
Submitted 14 August, 2018; v1 submitted 3 December, 2017;
originally announced December 2017.
-
Cryogenic magnetic coil and superconducting magnetic shield for neutron electric dipole moment searches
Authors:
S. Slutsky,
C. M. Swank,
A. Biswas,
R. Carr,
J. Escribano,
B. W. Filippone,
W. C. Griffith,
M. Mendenhall,
N. Nouri,
C. Osthelder,
A. Pérez Galván,
R. Picker,
B. Plaster
Abstract:
A magnetic coil operated at cryogenic temperatures is used to produce spatial, relative field gradients below 6 ppm/cm, stable for several hours. The apparatus is a prototype of the magnetic components for a neutron electric dipole moment (nEDM) search, which will take place at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory using ultra-cold neutrons (UCN). That search require…
▽ More
A magnetic coil operated at cryogenic temperatures is used to produce spatial, relative field gradients below 6 ppm/cm, stable for several hours. The apparatus is a prototype of the magnetic components for a neutron electric dipole moment (nEDM) search, which will take place at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory using ultra-cold neutrons (UCN). That search requires a uniform magnetic field to mitigate systematic effects and obtain long polarization lifetimes for neutron spin precession measurements. This paper details upgrades to a previously described apparatus, particularly the introduction of super-conducting magnetic shielding and the associated cryogenic apparatus. The magnetic gradients observed are sufficiently low for the nEDM search at SNS.
△ Less
Submitted 20 June, 2017; v1 submitted 10 January, 2017;
originally announced January 2017.
-
High-Sensitivity Measurement of 3He-4He Isotopic Ratios for Ultracold Neutron Experiments
Authors:
H. P. Mumm,
M. G. Huber,
W. Bauder,
N. Abrams,
C. M. Deibel,
C. R. Huffer,
P. R. Huffman,
K. W. Schelhammer,
C. M. Swank,
R. Janssens,
C. L. Jiang,
R. H. Scott,
R. C. Pardo,
K. E. Rehm,
R. Vondrasek,
C. M. O'Shaughnessy,
M. Paul,
L. Yang
Abstract:
Research efforts ranging from studies of solid helium to searches for a neutron electric dipole moment require isotopically purified helium with a ratio of 3He to 4He at levels below that which can be measured using traditional mass spectroscopy techniques. We demonstrate an approach to such a measurement using accelerator mass spectroscopy, reaching the 10e-14 level of sensitivity, several orders…
▽ More
Research efforts ranging from studies of solid helium to searches for a neutron electric dipole moment require isotopically purified helium with a ratio of 3He to 4He at levels below that which can be measured using traditional mass spectroscopy techniques. We demonstrate an approach to such a measurement using accelerator mass spectroscopy, reaching the 10e-14 level of sensitivity, several orders of magnitude more sensitive than other techniques. Measurements of 3He/4He in samples relevant to the measurement of the neutron lifetime indicate the need for substantial corrections. We also argue that there is a clear path forward to sensitivity increases of at least another order of magnitude.
△ Less
Submitted 31 December, 2015;
originally announced December 2015.
-
A prototype vector magnetic field monitoring system for a neutron electric dipole moment experiment
Authors:
N. Nouri,
A. Biswas,
M. A. Brown,
R. Carr,
B. Filippone,
C. Osthelder,
B. Plaster,
S. Slutsky,
C. Swank
Abstract:
We present results from a first demonstration of a magnetic field monitoring system for a neutron electric dipole moment experiment. The system is designed to reconstruct the vector components of the magnetic field in the interior measurement region solely from exterior measurements.
We present results from a first demonstration of a magnetic field monitoring system for a neutron electric dipole moment experiment. The system is designed to reconstruct the vector components of the magnetic field in the interior measurement region solely from exterior measurements.
△ Less
Submitted 10 November, 2015; v1 submitted 17 August, 2015;
originally announced August 2015.
-
Relaxation of Spin Polarized $^3$He in Mixtures of $^3$He and $^4$He at $\sim$330 mK
Authors:
Q. Ye,
H. Gao,
W. Zheng,
D. Dutta,
F. Dubose,
R. Golub,
P. Huffman,
C. Swank,
E. Korobkina
Abstract:
We report the measurements of depolarization probabilities of polarized $^3$He in a rectangular acrylic cell with a deuterated tetraphenyl butadiene-doped deuterated polystyrene coating filled with superfluid $^4$He at $\sim$330 mk with a magnetic holding field of $\sim$7.3 G. We achieve a wall depolarization probability of $\sim1.0\times10^{-7}$. Such a surface will find application in a new ex…
▽ More
We report the measurements of depolarization probabilities of polarized $^3$He in a rectangular acrylic cell with a deuterated tetraphenyl butadiene-doped deuterated polystyrene coating filled with superfluid $^4$He at $\sim$330 mk with a magnetic holding field of $\sim$7.3 G. We achieve a wall depolarization probability of $\sim1.0\times10^{-7}$. Such a surface will find application in a new experiment searching for the neutron electric dipole moment and other applications.
△ Less
Submitted 18 November, 2009;
originally announced November 2009.
-
Measuring the Neutron Lifetime Using Magnetically Trapped Neutrons
Authors:
C. M. O'Shaughnessy,
R. Golub,
K. W. Schelhammer,
C. M. Swank,
P. -N. Seo,
P. R. Huffman,
S. N. Dzhosyuk,
C. E. H. Mattoni,
L. Yang,
J. M. Doyle,
K. J. Coakley,
A. K. Thompson,
H. P. Mumm,
S. K. Lamoreaux,
G. Yang
Abstract:
The neutron beta-decay lifetime plays an important role both in understanding weak interactions within the framework of the Standard Model and in theoretical predictions of the primordial abundance of 4He in Big Bang Nucleosynthesis. In previous work, we successfully demonstrated the trapping of ultracold neutrons (UCN) in a conservative potential magnetic trap. A major upgrade of the apparatus…
▽ More
The neutron beta-decay lifetime plays an important role both in understanding weak interactions within the framework of the Standard Model and in theoretical predictions of the primordial abundance of 4He in Big Bang Nucleosynthesis. In previous work, we successfully demonstrated the trapping of ultracold neutrons (UCN) in a conservative potential magnetic trap. A major upgrade of the apparatus is nearing completion at the National Institute of Standards and Technology Center for Neutron Research (NCNR). In our approach, a beam of 0.89 nm neutrons is incident on a superfluid 4He target within the minimum field region of an Ioffe-type magnetic trap. A fraction of the neutrons is downscattered in the helium to energies <200 neV, and those in the appropriate spin state become trapped. The inverse process is suppressed by the low phonon density of helium at temperatures less than 200 mK, allowing the neutron to travel undisturbed. When the neutron decays the energetic electron ionizes the helium, producing scintillation light that is detected using photomultiplier tubes. Statistical limitations of the previous apparatus will be alleviated by significant increases in field strength and trap volume resulting in twenty times more trapped neutrons.
△ Less
Submitted 31 March, 2009;
originally announced March 2009.
-
Electric dipole moment searches: Effect of linear electric field frequency shifts induced in confined gases, II
Authors:
R. Golub,
C. M. Swank,
S. K. Lamoreaux
Abstract:
The next generation of particle edm searches will be at such a high sensitivity that it will be possible for the results to be contaminated by a systematic error resulting from the interaction of the motional (E x v/c) magnetic field with stray field gradients. In this paper we extend previous work to present an analytic form for the frequency shift in the case of a rectangular storage vessel an…
▽ More
The next generation of particle edm searches will be at such a high sensitivity that it will be possible for the results to be contaminated by a systematic error resulting from the interaction of the motional (E x v/c) magnetic field with stray field gradients. In this paper we extend previous work to present an analytic form for the frequency shift in the case of a rectangular storage vessel and discuss the implications of the result for the neutron edm experiment which will be installed at the SNS (Spallation Neutron Source) by the LANL collaboration
△ Less
Submitted 3 June, 2009; v1 submitted 29 October, 2008;
originally announced October 2008.