Temperature dependence of the probability of "small heating" and total losses of ucns on the surface of fomblin oils of different molecular mass
Authors:
S. M. Cherniavsky,
E. V. Lychagin,
A. Yu. Muzychka,
G. V. Nekhaev,
V. V. Nesvizhevsky,
S. Reynaud,
A. V. Strelkov,
K. Turlybekuly
Abstract:
We measured the temperature dependence of the probability of small heating and total losses of UCNs on the PFPE Fomblin Y surface with various molecular masses Mw=2800, 3300, 6500 amu in the temperature range of 100-300 K. The probability of small heating sharply decreases with increasing Mw and decreasing temperature. The probability of total loss weakly decreases with decreasing temperature and…
▽ More
We measured the temperature dependence of the probability of small heating and total losses of UCNs on the PFPE Fomblin Y surface with various molecular masses Mw=2800, 3300, 6500 amu in the temperature range of 100-300 K. The probability of small heating sharply decreases with increasing Mw and decreasing temperature. The probability of total loss weakly decreases with decreasing temperature and takes the minimum value at Mw=3300 amu. As this oil provides a homogeneous surface with minimal probabilities of small heating and total losses of UCNs, it is the preferred candidate for experiments on measuring the neutron lifetime.
△ Less
Submitted 5 April, 2019;
originally announced April 2019.
-
Design and test of a compact and high-resolution time-of-flight measurement device for cold neutron beams
Authors:
Damien Roulier,
Valery Nesvizhevsky,
Benoît Clément,
Guilhem Freche,
Guillaume Pignol,
Dominique Rebreyend,
Francis Vezzu,
Stefan Baeßler,
Alexander Strelkov
Abstract:
A time-of-flight device was developed to characterize wavelength distribution and uniformity of a cold neutron beam. This device is very compact -- the distance of flight is $60$ cm -- but achieves very high resolution -- the intrinsic resolution $Δλ/λ=2.4\cdot 10^{-3}$ at $λ=0.89$ nm. The time-of-flight device is composed of a fixed slit, a disk rotating up to $216$ Hz and a neutron detector with…
▽ More
A time-of-flight device was developed to characterize wavelength distribution and uniformity of a cold neutron beam. This device is very compact -- the distance of flight is $60$ cm -- but achieves very high resolution -- the intrinsic resolution $Δλ/λ=2.4\cdot 10^{-3}$ at $λ=0.89$ nm. The time-of-flight device is composed of a fixed slit, a disk rotating up to $216$ Hz and a neutron detector with a thin spherical conversion layer with the chopper slit in its focus. The device accepts the complete angular divergence of the initial neutron beam. The efficiency of neutron detection is constant over the detector area. Systematic corrections caused by neutron scattering in air are minimized due to the reduction of the time-of-flight length. Measurements have been performed on the beamline of the GRANIT experiment at ILL (part of the H172 beamline) on level C, and the first order diffraction peak of the crystal monochromator used for the GRANIT beamline was found to be at $λ=0.8961(11)$ nm, and having a width of $σ=0.0213(13)$ nm.
△ Less
Submitted 8 March, 2019; v1 submitted 29 May, 2018;
originally announced May 2018.
-
Temperature dependence of the probability of "small heating" and spectrum of UCNs up-scattered on the surface of Fomblin oil Y-HVAC 18/8
Authors:
V. V. Nesvizhevsky,
A. Yu. Voronin,
A. Lambrecht,
S. Reynaud,
E. V. Lychagin,
A. Yu. Muzychka,
G. V. Nekhaev,
A. V. Strelkov
Abstract:
We performed precision measurements of the probability of small heating and spectrum of UCNs up-scattered on the surface of hydrogen-free oil Fomblin Y-HVAC 18/8 as a function of temperature. The probability is well reproducible, does not depend on sample thickness and does not evolve in time. It is equal (9.8+-0.2)10^(-6) at the ambient temperature. The spectrum coincides with those measured with…
▽ More
We performed precision measurements of the probability of small heating and spectrum of UCNs up-scattered on the surface of hydrogen-free oil Fomblin Y-HVAC 18/8 as a function of temperature. The probability is well reproducible, does not depend on sample thickness and does not evolve in time. It is equal (9.8+-0.2)10^(-6) at the ambient temperature. The spectrum coincides with those measured with solid-surface and nanoparticle samples. Indirect arguments indicate that spectrum shape weakly depends on temperature. Measured experimental data can be satisfactory described both within the model of near-surface nanodroplets and the model of capillary waves.
△ Less
Submitted 20 September, 2016;
originally announced September 2016.
-
UCN sources at external beams of thermal neutrons. An example of PIK reactor
Authors:
E. V. Lychagin,
V. A. Mityukhlyaev,
A. Yu. Muzychka,
G. V. Nekhaev,
V. V. Nesvizhevsky,
M. S. Onegin,
E. I. Sharapov,
A. V. Strelkov
Abstract:
We consider ultracold neutron (UCN) sources based on a new method of UCN production in superfluid helium (4He). The PIK reactor is chosen as a perspective example of the application of this idea, which consists of installing a 4He UCN source in a beam of thermal or cold neutrons and surrounding the source with a moderator-reflector, which plays the role of a source of cold neutrons (CNs) feeding t…
▽ More
We consider ultracold neutron (UCN) sources based on a new method of UCN production in superfluid helium (4He). The PIK reactor is chosen as a perspective example of the application of this idea, which consists of installing a 4He UCN source in a beam of thermal or cold neutrons and surrounding the source with a moderator-reflector, which plays the role of a source of cold neutrons (CNs) feeding the UCN source. The CN flux in the source can be several times larger than the incident flux, due to multiple neutron reflections from the moderator-reflector. We show that such a source at the PIK reactor would provide an order of magnitude larger density and production rate than an analogous source at the ILL reactor.
We estimate parameters of a 4He source with solid methane (CH4) or/and liquid deuterium (D2) moderator-reflector. We show that such a source with CH4 moderator-reflector at the PIK reactor would provide the UCN density of ~1x10^5 1/cm^3, and the UCN production rate of ~2x10^7 1/s. These values are respectively 1000 and 20 times larger than those for the most intense UCN user source. The UCN density in a source with D2 moderator-reflector would reach the value of ~2x10^5 1/cm^3, and the UCN production rate would be equal ~8x10^7 1/s. Installation of such sources in beams of CNs with equal flux would slightly increase the density and production rate.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
Quasi-specular albedo of cold neutrons from powder of nanoparticles
Authors:
R. Cubitt,
E. V. Lychagin,
A. Yu. Muzychka,
G. V. Nekhaev,
V. V. Nesvizhevsky,
G. Pignol,
K. V. Protasov,
A. V. Strelkov
Abstract:
We predicted and observed for the first time the quasi-specular albedo of cold neutrons at small incidence angles from a powder of nanoparticles. This albedo (reflection) is due to multiple neutron small-angle scattering. The reflection angle as well as the half-width of angular distribution of reflected neutrons is approximately equal to the incidence angle. The measured reflection probability…
▽ More
We predicted and observed for the first time the quasi-specular albedo of cold neutrons at small incidence angles from a powder of nanoparticles. This albedo (reflection) is due to multiple neutron small-angle scattering. The reflection angle as well as the half-width of angular distribution of reflected neutrons is approximately equal to the incidence angle. The measured reflection probability was equal to ~30% within the detector angular size that corresponds to 40-50% total calculated probability of quasi-specular reflection.
△ Less
Submitted 8 October, 2009;
originally announced October 2009.
-
Storage of very cold neutrons in a trap with nano-structured walls
Authors:
E. V. Lychagin,
A. Yu. Muzychka,
V. V. Nesvizhevsky,
G. Pignol,
K. V. Protasov,
A. V. Strelkov
Abstract:
We report on storage of Very Cold Neutrons (VCN) in a trap with walls containing powder of diamond nanoparticles. The efficient VCN reflection is provided by multiple diffusive elastic scattering of VCN at single nanoparticles in powder. The VCN storage times are sufficiently long for accumulating large density of neutrons with complete VCN energy range of up to a few times 10(-4) eV. Methods fo…
▽ More
We report on storage of Very Cold Neutrons (VCN) in a trap with walls containing powder of diamond nanoparticles. The efficient VCN reflection is provided by multiple diffusive elastic scattering of VCN at single nanoparticles in powder. The VCN storage times are sufficiently long for accumulating large density of neutrons with complete VCN energy range of up to a few times 10(-4) eV. Methods for further improvements of VCN storage times are discussed.
△ Less
Submitted 9 December, 2008;
originally announced December 2008.
-
The reflection of very cold neutrons from diamond powder nanoparticles
Authors:
V. V. Nesvizhevsky,
E. V. Lychagin,
A. Yu. Muzychka,
A. V. Strelkov,
G. Pignol,
K. V. Protasov
Abstract:
We study possibility of efficient reflection of very cold neutrons (VCN) from powders of nanoparticles. In particular, we measured the scattering of VCN at a powder of diamond nanoparticles as a function of powder sample thickness, neutron velocity and scattering angle. We observed extremely intense scattering of VCN even off thin powder samples. This agrees qualitatively with the model of indep…
▽ More
We study possibility of efficient reflection of very cold neutrons (VCN) from powders of nanoparticles. In particular, we measured the scattering of VCN at a powder of diamond nanoparticles as a function of powder sample thickness, neutron velocity and scattering angle. We observed extremely intense scattering of VCN even off thin powder samples. This agrees qualitatively with the model of independent nanoparticles at rest. We show that this intense scattering would allow us to use nanoparticle powders very efficiently as the very first reflectors for neutrons with energies within a complete VCN range up to $10^{-4}$ eV.
△ Less
Submitted 16 May, 2008;
originally announced May 2008.