Low-threshold response of a scintillating xenon bubble chamber to nuclear and electronic recoils
Authors:
E. Alfonso-Pita,
E. Behnke,
M. Bressler,
B. Broerman,
K. Clark,
R. Coppejans,
J. Corbett,
M. Crisler,
C. E. Dahl,
K. Dering,
A. de St. Croix,
D. Durnford,
P. Giampa,
J. Hall,
O. Harris,
H. Hawley-Herrera,
N. Lamb,
M. Laurin,
I. Levine,
W. H. Lippincott,
R. Neilson,
M. -C. Piro,
D. Pyda,
Z. Sheng,
G. Sweeney
, et al. (7 additional authors not shown)
Abstract:
A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ~4 keV showed sensitivity to ~20 keV nuclear recoils with no observable bubble nucleation by $γ$-ray interactions. This paper presents results from further operation of the same device at…
▽ More
A device filled with pure xenon first demonstrated the ability to operate simultaneously as a bubble chamber and scintillation detector in 2017. Initial results from data taken at thermodynamic thresholds down to ~4 keV showed sensitivity to ~20 keV nuclear recoils with no observable bubble nucleation by $γ$-ray interactions. This paper presents results from further operation of the same device at thermodynamic thresholds as low as 0.50 keV, hardware limited. The bubble chamber has now been shown to have sensitivity to ~1 keV nuclear recoils while remaining insensitive to bubble nucleation by $γ$-rays. A robust calibration of the chamber's nuclear recoil nucleation response, as a function of nuclear recoil energy and thermodynamic state, is presented. Stringent upper limits are established for the probability of bubble nucleation by $γ$-ray-induced Auger cascades, with a limit of $<1.1\times10^{-6}$ set at 0.50 keV, the lowest thermodynamic threshold explored.
△ Less
Submitted 12 February, 2025; v1 submitted 7 October, 2024;
originally announced October 2024.
-
Snowmass 2021 Scintillating Bubble Chambers: Liquid-noble Bubble Chambers for Dark Matter and CE$ν$NS Detection
Authors:
E. Alfonso-Pita,
M. Baker,
E. Behnke,
A. Brandon,
M. Bressler,
B. Broerman,
K. Clark,
R. Coppejans,
J. Corbett,
C. Cripe,
M. Crisler,
C. E. Dahl,
K. Dering,
A. de St. Croix,
D. Durnford,
K. Foy,
P. Giampa,
J. Gresl,
J. Hall,
O. Harris,
H. Hawley-Herrera,
C. M. Jackson,
M. Khatri,
Y. Ko,
N. Lamb
, et al. (20 additional authors not shown)
Abstract:
The Scintillating Bubble Chamber (SBC) Collaboration is developing liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This dev…
▽ More
The Scintillating Bubble Chamber (SBC) Collaboration is developing liquid-noble bubble chambers for the quasi-background-free detection of low-mass (GeV-scale) dark matter and coherent scattering of low-energy (MeV-scale) neutrinos (CE$ν$NS). The first physics-scale demonstrator of this technique, a 10-kg liquid argon bubble chamber dubbed SBC-LAr10, is now being commissioned at Fermilab. This device will calibrate the background discrimination power and sensitivity of superheated argon to nuclear recoils at energies down to 100 eV. A second functionally-identical detector with a focus on radiopure construction is being built for SBC's first dark matter search at SNOLAB. The projected spin-independent sensitivity of this search is approximately $10^{-43}$ cm$^2$ at 1 GeV$/c^2$ dark matter particle mass. The scalability and background discrimination power of the liquid-noble bubble chamber make this technique a compelling candidate for future dark matter searches to the solar neutrino fog at 1 GeV$/c^2$ particle mass (requiring a $\sim$ton-year exposure with non-neutrino backgrounds sub-dominant to the solar CE$ν$NS signal) and for high-statistics CE$ν$NS studies at nuclear reactors.
△ Less
Submitted 29 September, 2022; v1 submitted 21 July, 2022;
originally announced July 2022.
-
Physics reach of a low threshold scintillating argon bubble chamber in coherent elastic neutrino-nucleus scattering reactor experiments
Authors:
L. J. Flores,
Eduardo Peinado,
E. Alfonso-Pita,
K. Allen,
M. Baker,
E. Behnke,
M. Bressler,
K. Clark,
R. Coppejans,
C. Cripe,
M. Crisler,
C. E. Dahl,
A. de St. Croix,
D. Durnford,
P. Giampa,
O. Harris,
P. Hatch,
H. Hawley,
C. M. Jackson,
Y. Ko,
C. Krauss,
N. Lamb,
M. Laurin,
I. Levine,
W. H. Lippincott
, et al. (9 additional authors not shown)
Abstract:
The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the sig…
▽ More
The physics reach of a low threshold (100 eV) scintillating argon bubble chamber sensitive to Coherent Elastic neutrino-Nucleus Scattering (CE$ν$NS) from reactor neutrinos is studied. The sensitivity to the weak mixing angle, neutrino magnetic moment, and a light $Z'$ gauge boson mediator are analyzed. A Monte Carlo simulation of the backgrounds is performed to assess their contribution to the signal. The analysis shows that world-leading sensitivities are achieved with a one-year exposure for a 10 kg chamber at 3 m from a 1 MW$_{th}$ research reactor or a 100 kg chamber at 30 m from a 2000 MW$_{th}$ power reactor. Such a detector has the potential to become the leading technology to study CE$ν$NS using nuclear reactors.
△ Less
Submitted 26 May, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
Demonstration of Laser-produced Neutron Diagnostic by Radiative Capture Gamma-rays
Authors:
Xiaopeng Zhang,
Wenqing Wei,
Changbo Fu,
Xiaohui Yuan,
Songhai An,
Yanqing Deng,
Yuan Fang,
Jian Gao,
Xulei Ge,
Bing Guo,
Chuangye He,
Peng Hu,
Neng Hua,
Weiman Jiang,
Liang Li,
Mengting Li,
Yifei Li,
Yutong Li,
Guoqiang Liao,
Feng Liu,
Longxiang Liu,
Hongwei Wang,
Pengqian Yang,
Su Yang,
Tao Yang
, et al. (7 additional authors not shown)
Abstract:
We report a new scenario of time-of-flight (TOF) technique in which fast neutrons and delayed gamma-ray signals were both recorded in a millisecond time window in harsh environments induced by high-intensity lasers. The delayed gamma signals, arriving far later than the original fast neutron and often being ignored previously, were identified to be the results of radiative captures of thermalized…
▽ More
We report a new scenario of time-of-flight (TOF) technique in which fast neutrons and delayed gamma-ray signals were both recorded in a millisecond time window in harsh environments induced by high-intensity lasers. The delayed gamma signals, arriving far later than the original fast neutron and often being ignored previously, were identified to be the results of radiative captures of thermalized neutrons. The linear correlation between gamma photon number and the fast neutron yield shows that these delayed gamma events can be employed for neutron diagnosis. This method can reduce the detecting efficiency dropping problem caused by prompt high-flux gamma radiation, and provides a new way for neutron diagnosing in high-intensity laser-target interaction experiments.
△ Less
Submitted 19 September, 2017;
originally announced September 2017.
-
Sensitivity of deexcitation energies of superdeformed secondary minima to the density dependence of symmetry energy with the relativistic mean-field theory
Authors:
W. Z. Jiang,
Z. Z. Ren,
Z. Q. Sheng,
Z. Y. Zhu
Abstract:
The relationship between deexcitation energies of superdeformed secondary minima relative to ground states and the density dependence of the symmetry energy is investigated for heavy nuclei using the relativistic mean field (RMF) model. It is shown that the deexcitation energies of superdeformed secondary minima are sensitive to differences in the symmetry energy that are mimicked by the isoscalar…
▽ More
The relationship between deexcitation energies of superdeformed secondary minima relative to ground states and the density dependence of the symmetry energy is investigated for heavy nuclei using the relativistic mean field (RMF) model. It is shown that the deexcitation energies of superdeformed secondary minima are sensitive to differences in the symmetry energy that are mimicked by the isoscalar-isovector coupling included in the model. With deliberate investigations on a few Hg isotopes that have data of deexcitation energies, we find that the description for the deexcitation energies can be improved due to the softening of the symmetry energy. Further, we have investigated deexcitation energies of odd-odd heavy nuclei that are nearly independent of pairing correlations, and have discussed the possible extraction of the constraint on the density dependence of the symmetry energy with the measurement of deexcitation energies of these nuclei.
△ Less
Submitted 11 April, 2010;
originally announced April 2010.