-
Johnson-Nyquist Noise Effects in Neutron Electric-Dipole-Moment Experiments
Authors:
N. J. Ayres,
G. Ban,
G. Bison,
K. Bodek,
V. Bondar,
P. -J. Chiu,
B. Clement,
C. B. Crawford,
M. Daum,
S. Emmenegger,
M. Fertl,
A. Fratangelo,
W. C. Griffith,
Z. D. Grujić,
P. G. Harris,
K. Kirch,
P. A. Koss,
B. Lauss,
T. Lefort,
P. Mohanmurthy,
O. Naviliat-Cuncic,
D. Pais,
F. M. Piegsa,
G. Pignol,
D. Rebreyend
, et al. (15 additional authors not shown)
Abstract:
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and v…
▽ More
Magnetic Johnson-Nyquist noise (JNN) originating from metal electrodes, used to create a static electric field in neutron electric-dipole-moment (nEDM) experiments, may limit the sensitivity of measurements. We present here the first dedicated study on JNN applied to a large-scale long-measurement-time experiment with the implementation of a co-magnetometry. In this study, we derive surface- and volume-averaged root-mean-square normal noise amplitudes at a certain frequency bandwidth for a cylindrical geometry. In addition, we model the source of noise as a finite number of current dipoles and demonstrate a method to simulate temporal and three-dimensional spatial dependencies of JNN. The calculations are applied to estimate the impact of JNN on measurements with the new apparatus, n2EDM, at the Paul Scherrer Institute. We demonstrate that the performances of the optically pumped $^{133}$Cs magnetometers and $^{199}$Hg co-magnetometers, which will be used in the apparatus, are not limited by JNN. Further, we find that in measurements deploying a co-magnetometer system, the impact of JNN is negligible for nEDM searches down to a sensitivity of $4\,\times\,10^{-28}\,e\cdot{\rm cm}$ in a single measurement; therefore, the use of economically and mechanically favored solid aluminum electrodes is possible.
△ Less
Submitted 9 July, 2021; v1 submitted 2 February, 2021;
originally announced February 2021.
-
The design of the n2EDM experiment
Authors:
N. J. Ayres,
G. Ban,
L. Bienstman,
G. Bison,
K. Bodek,
V. Bondar,
T. Bouillaud,
E. Chanel,
J. Chen,
P. -J. Chiu,
B. Clément,
C. Crawford,
M. Daum,
B. Dechenaux,
C. B. Doorenbos,
S. Emmenegger,
L. Ferraris-Bouchez,
M. Fertl,
A. Fratangelo,
P. Flaux,
D. Goupillière,
W. C. Griffith,
Z. D. Grujic,
P. G. Harris,
K. Kirch
, et al. (36 additional authors not shown)
Abstract:
We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnit…
▽ More
We present the design of a next-generation experiment, n2EDM, currently under construction at the ultracold neutron source at the Paul Scherrer Institute (PSI) with the aim of carrying out a high-precision search for an electric dipole moment of the neutron. The project builds on experience gained with the previous apparatus operated at PSI until 2017, and is expected to deliver an order of magnitude better sensitivity with provision for further substantial improvements. An overview is given of the experimental method and setup, the sensitivity requirements for the apparatus are derived, and its technical design is described.
△ Less
Submitted 22 January, 2021; v1 submitted 21 January, 2021;
originally announced January 2021.
-
Upgrade of the ultracold neutron source at the pulsed reactor TRIGA Mainz
Authors:
Jan Kahlenberg,
Dieter Ries,
Kim Ulrike Ross,
Christian Siemensen,
Marcus Beck,
Christopher Geppert,
Werner Heil,
Nicolas Hild,
Jan Karch,
Sergei Karpuk,
Fabian Kories,
Matthias Kretschmer,
Bernhard Lauss,
Tobias Reich,
Yuri Sobolev,
Norbert Trautmann
Abstract:
The performance of the upgraded solid deuterium ultracold neutron source at the pulsed reactor TRIGA Mainz is described. The current configuration stage comprises the installation of a He liquefier to run UCN experiments over long-term periods, the use of stainless steel neutron guides with improved transmission as well as sputter-coated non-magnetic $^{58}$NiMo alloy at the inside walls of the th…
▽ More
The performance of the upgraded solid deuterium ultracold neutron source at the pulsed reactor TRIGA Mainz is described. The current configuration stage comprises the installation of a He liquefier to run UCN experiments over long-term periods, the use of stainless steel neutron guides with improved transmission as well as sputter-coated non-magnetic $^{58}$NiMo alloy at the inside walls of the thermal bridge and the converter cup. The UCN yield was measured in a `standard' UCN storage bottle (stainless steel) with a volume of 32 litres outside the biological shield at the experimental area yielding UCN densities of 8.5 /cm$^3$; an increase by a factor of 3.5 compared to the former setup. The measured UCN storage curve is in good agreement with the predictions from a Monte Carlo simulation developed to model the source. The growth and formation of the solid deuterium converter during freeze-out are affected by the ortho/para ratio of the H$_2$ premoderator.
△ Less
Submitted 9 November, 2017; v1 submitted 23 June, 2017;
originally announced June 2017.