-
Recent advancements of the experiment to search for $2K$-capture in $^{124}$Xe using a Large Low-background Proportional Counter
Authors:
O. D. Petrenko,
I. D. Fedorets,
A. M. Gangapshev,
Yu. M. Garilyuk,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich
Abstract:
A new method for correcting the charge signal from the large proportional counter is proposed. The correction method makes it possible to take into account the loss of primary ionization electrons in the presence of weakly increasing micro impurities of electronegative gases during long-term measurements. It allows increasing the efficiency of the selection of useful events and thereby increasing…
▽ More
A new method for correcting the charge signal from the large proportional counter is proposed. The correction method makes it possible to take into account the loss of primary ionization electrons in the presence of weakly increasing micro impurities of electronegative gases during long-term measurements. It allows increasing the efficiency of the selection of useful events and thereby increasing the sensitivity to $2\nu2K$-decay in $^{124}$Xe at the level of $2\times10^{22}$ from over six years of measurements using a large proportional counter. Analysis of the calibration data, taking into account the new method for correcting the energy release in the detector, made it possible to register events from double $K$ photoionization by a single photon.
△ Less
Submitted 6 October, 2021;
originally announced October 2021.
-
Annual variations of the $^{214}$Po, $^{213}$Po and $^{212}$Po half-life values
Authors:
E. N. Alexeev,
A. M. Gangapshev,
Yu. M. Gavrilyuk,
A. M. Gezhaev,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
O. D. Petrenko,
S. S. Ratkevich
Abstract:
Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47\pm0.03$ $μ$s), $^{213}$Po ($T_{1/2}=3.705 \pm 0.001$ $μ$s) and $^{212}$Po ($T_{1/2}=294.09\pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two independent sequential sets of the $^{214}$Po $τ$-values $(τ\equiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal function…
▽ More
Results of a comparative analysis of the $^{214}$Po ($T_{1/2}= 163.47\pm0.03$ $μ$s), $^{213}$Po ($T_{1/2}=3.705 \pm 0.001$ $μ$s) and $^{212}$Po ($T_{1/2}=294.09\pm0.07$ ns) half-life annular variation parameters are presented. It is shown that two independent sequential sets of the $^{214}$Po $τ$-values $(τ\equiv T_{1/2})$ obtained in the spaced laboratories can be described by sinusoidal functions. The sinusoid curve with amplitude $A=(5.0 \pm1.5) \cdot 10^{-4}$, period $ω=(365\pm 8)$ days, and phase $φ=(170 \pm 7)$ days approximates the set of $^{214}$Po $τ$ values obtained at BNO INR RAS during the $\sim$973 days starting on January 4, 2012. The function approximates a set of $τ$-values with a time duration of $\sim1460$ days obtained at the KhNU has an amplitude $A=(4.9\pm1.8)\cdot10^{-4}$, a period $ω= (377\pm13)$ days and a phase $φ=(77\pm10)$ days. The $^{213}$Po $τ$-value set with a time duration of $\sim1700$ days can be described by a sinusoidal function with an amplitude $A=(3.9\pm1.2)\cdot10^{-4}$, a period $ω= (370\pm13)$ days and a phase $φ=(130\pm9)$ days. The $^{212}$Po $τ$-value set with a time duration of $\sim670$ days can be described by a sinusoidal function with an amplitude $A=(7.5\pm1.6)\cdot10^{-4}$, a period $ω= (375\pm13)$ days and a phase $φ=(40\pm10)$ days.
△ Less
Submitted 16 October, 2020;
originally announced October 2020.
-
Improving Calibration of the Large Low-Background Proportional Counter
Authors:
O. D. Petrenko,
A. M. Gangapshev,
Yu. M. Garilyuk,
V. V. Kazalov,
V. V. Kuzminov,
S. I. Panasenko,
S. S. Ratkevich,
D. A. Tekueva
Abstract:
The study of low-yield effects requires not only good quality of the original data but also puts high requirements for their processing procedures to increase the efficiency of the selection of useful events. The exploiting of the large cylindrical proportional counter's electrostatic topology allows improving the extrapolation of information about the primary ionization of a multipoint event. Lon…
▽ More
The study of low-yield effects requires not only good quality of the original data but also puts high requirements for their processing procedures to increase the efficiency of the selection of useful events. The exploiting of the large cylindrical proportional counter's electrostatic topology allows improving the extrapolation of information about the primary ionization of a multipoint event. Long-term calibration measurements with an external $^{109}$Cd-source allowed the development of a new method for analyzing the pulse shape from a sizeable proportional counter. Optimized analysis of the current's pulse shape from the electron cloud of primary ionization in the counter improved the resolution and energy calibration. As a result, the efficiency of selecting useful events was increased by 25\%.
△ Less
Submitted 15 October, 2020;
originally announced October 2020.