-
Measurements using a prototype array of plastic scintillator bars for reactor based electron anti-neutrino detection
Authors:
P. K. Netrakanti,
D. Mulmule,
D. K. Mishra,
S. P. Behera,
R. Dey,
R. Sehgal,
S. K. Sinha,
V. Jha,
L. M. Pant
Abstract:
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy d…
▽ More
We report measurement of reactor based electron anti-neutrinos from a prototype array of plastic scintillator bars ( mini-ISMRAN ) located inside Dhruva research reactor hall, BARC. The detector setup took data for 128 days for reactor on (RON) and 51 days for reactor off (ROFF) condition. A detailed analysis procedure is developed to select the anti-neutrino candidate events based on the energy deposition, number of bars hit as well as topological event selection criteria in position and time. Each of these selection criteria are compared with Monte Carlo based simulations and further an embedding technique is used to estimate the efficiencies from a data driven background study. The obtained anti-neutrino like events in RON condition are 218 $\pm$ 50 (stat) $\pm$ 37 (sys) after background subtraction. The obtained results are compared with theoretical estimation which yields 214 $\pm$ 32 (sys) anti-neutrino events for the RON condition.
△ Less
Submitted 28 December, 2021; v1 submitted 24 December, 2021;
originally announced December 2021.
-
Characterization of plastic scintillator bars using fast neutrons from D-D and D-T reactions
Authors:
R. Dey,
P. K. Netrakanti,
D. K. Mishra,
S. P. Behera,
D. Mulmule,
T. Patel,
P. S. Sarkar,
V. Jha,
L. M. Pant
Abstract:
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse…
▽ More
We report results of fast neutron response in plastic scintillator (PS) bars from deuterium-deuterium (D-D) and deuterium-tritium (D-T) reactions using Purnima Neutron Generator Facility, BARC, Mumbai. These measurements are useful in context of Indian Scintillator Matrix for Reactor Anti-Neutrino (ISMRAN) detection, an array of 10x10 PS bars, used to measure reactor anti-neutrinos through inverse beta decay (IBD) signal. ISMRAN detector, an above-ground experiment close to the reactor core (~13m), deals with an active fast neutron background inside the reactor hall. A good understanding of fast neutron response in PS bars is an essential pre-requisite for suppression and discrimination of fast neutron background from IBD events. A monoenergetic neutron beam from the fusion reaction of D-D at 2.45 MeV and D-T at 14.1 MeV are used to characterize the energy response in these bars. The neutron energy response function has been simulated using the GEANT4 package and are compared with the measured data. A reasonable agreement of deposited energies by fast neutrons in PS bars between data and simulation are obtained for these reactions. The ratio of energy deposition in adjacent bars is used to discriminate between prompt IBD, fast neutron and neutron capture cascade gamma events.
△ Less
Submitted 4 November, 2021; v1 submitted 15 October, 2021;
originally announced October 2021.
-
Machine learning technique to improve anti-neutrino detection efficiency for the ISMRAN experiment
Authors:
D. Mulmule,
P. K. Netrakanti,
L. M. Pant,
B. K. Nayak
Abstract:
The Indian Scintillator Matrix for Reactor Anti-Neutrino detection - ISMRAN experiment aims to detect electron anti-neutrinos ($\barν_e$) emitted from a reactor via inverse beta decay reaction (IBD). The setup, consisting of 1 ton segmented Gadolinium foil wrapped plastic scintillator array, is planned for remote reactor monitoring and sterile neutrino search. The detection of prompt positron and…
▽ More
The Indian Scintillator Matrix for Reactor Anti-Neutrino detection - ISMRAN experiment aims to detect electron anti-neutrinos ($\barν_e$) emitted from a reactor via inverse beta decay reaction (IBD). The setup, consisting of 1 ton segmented Gadolinium foil wrapped plastic scintillator array, is planned for remote reactor monitoring and sterile neutrino search. The detection of prompt positron and delayed neutron from IBD will provide the signature of $\barν_e$ event in ISMRAN. The number of segments with energy deposit ($\mathrm{N_{bars}}$) and sum total of these deposited energies are used as discriminants for identifying prompt positron event and delayed neutron capture event. However, a simple cut based selection of above variables leads to a low $\barν_e$ signal detection efficiency due to overlapping region of $\mathrm{N_{bars}}$ and sum energy for the prompt and delayed events. Multivariate analysis (MVA) tools, employing variables suitably tuned for discrimination, can be useful in such scenarios. In this work we report the results from an application of artificial neural network -- the multilayer perceptron (MLP), particularly the Bayesian extension -- MLPBNN, to the simulated signal and background events in ISMRAN. The results from application of MLP to classify prompt positron events from delayed neutron capture events on Hydrogen, Gadolinium nuclei and also from the typical reactor $γ$-ray and fast neutron backgrounds is reported. An enhanced efficiency of $\sim$91$\%$ with a background rejection of $\sim$73$\%$ for prompt selection and an efficiency of $\sim$89$\%$ with a background rejection of $\sim$71$\%$ for the delayed capture event, is achieved using the MLPBNN classifier for the ISMRAN experiment.
△ Less
Submitted 20 May, 2020; v1 submitted 2 January, 2020;
originally announced January 2020.