-
Solar neutrino capture by 128, 130Te isotopes and Baksan Large Neutrino Telescope Project
Authors:
A. N. Fazliakhmetov,
Yu. S. Lutostansky,
B. K. Lubsandorzhiev,
G. A. Koroteev,
V. N. Tikhonov
Abstract:
This paper discusses the charge-exchange strength functions $S(E)$ of the isotopes $^{128,130}$Te. The experimental data of the $S(E)$ strength functions obtained from $(^{3}\mathrm{He}, t)$ reactions, as well as the $S(E)$ strength functions calculated in the microscopic theory of finite fermi-systems, are analyzed. The resonance structure of the strength function $S(E)$ is examined, and the Gamo…
▽ More
This paper discusses the charge-exchange strength functions $S(E)$ of the isotopes $^{128,130}$Te. The experimental data of the $S(E)$ strength functions obtained from $(^{3}\mathrm{He}, t)$ reactions, as well as the $S(E)$ strength functions calculated in the microscopic theory of finite fermi-systems, are analyzed. The resonance structure of the strength function $S(E)$ is examined, and the Gamow-Teller and Pygmy resonances are identified. The resonance structure of the strength function $S(E)$ is vital for the calculation and analysis of the process of neutrino capture by atomic nuclei.
△ Less
Submitted 14 July, 2024;
originally announced July 2024.
-
A Search for Electron Neutrino Transitions to Sterile States in the BEST Experiment
Authors:
V. V. Barinov,
B. T. Cleveland,
S. N. Danshin,
H. Ejiri,
S. R. Elliott,
D. Frekers,
V. N. Gavrin,
V. V. Gorbachev,
D. S. Gorbunov,
W. C. Haxton,
T. V. Ibragimova,
I. Kim,
Yu. P. Kozlova,
L. V. Kravchuk,
V. V. Kuzminov,
B. K. Lubsandorzhiev,
Yu. M. Malyshkin,
R. Massarczyk,
V. A. Matveev,
I. N. Mirmov,
J. S. Nico,
A. L. Petelin,
R. G. H. Robertson,
D. Sinclair,
A. A. Shikhin
, et al. (5 additional authors not shown)
Abstract:
The Baksan Experiment on Sterile Transitions (BEST) probes the gallium anomaly and its possible connections to oscillations between active and sterile neutrinos. Based on the Gallium-Germanium Neutrino Telescope (GGNT) technology of the SAGE experiment, BEST employs two zones of liquid Ga target to explore neutrino oscillations on the meter scale. Oscillations on this short scale could produce def…
▽ More
The Baksan Experiment on Sterile Transitions (BEST) probes the gallium anomaly and its possible connections to oscillations between active and sterile neutrinos. Based on the Gallium-Germanium Neutrino Telescope (GGNT) technology of the SAGE experiment, BEST employs two zones of liquid Ga target to explore neutrino oscillations on the meter scale. Oscillations on this short scale could produce deficits in the $^{71}$Ge production rates within the two zones, as well as a possible rate difference between the zones.
From July 5th to October 13th 2019, the two-zone target was exposed to a primarily monoenergetic, 3.4-MCi $^{51}$Cr neutrino source 10 times for a total of 20 independent $^{71}$Ge extractions from the two Ga targets. The $^{71}$Ge production rates from the neutrino source were measured from July 2019 to March 2020. At the end of these measurements, the counters were filled with $^{71}$Ge doped gas and calibrated during November 2020. In this paper, results from the BEST sterile neutrino oscillation experiment are presented in details. The ratio of the measured $^{71}$Ge production rates to the predicted rates for the inner and the outer target volumes are calculated from the known neutrino capture cross section. Comparable deficits in the measured ratios relative to predicted values are found for both zones, with the $4 σ$ deviations from unity consistent with the previously reported gallium anomaly. If interpreted in the context of neutrino oscillations, the deficits give best fit oscillation parameters of $Δm^2=3.3^{+\infty}_{-2.3}$ eV$^2$ and sin$^2 2θ=0.42^{+0.15}_{-0.17}$, consistent with $ν_e \rightarrow ν_s$ oscillations governed by a surprisingly large mixing angle.
△ Less
Submitted 6 May, 2022; v1 submitted 18 January, 2022;
originally announced January 2022.
-
Results from the Baksan Experiment on Sterile Transitions (BEST)
Authors:
V. V. Barinov,
B. T. Cleveland,
S. N. Danshin,
H. Ejiri,
S. R. Elliott,
D. Frekers,
V. N. Gavrin,
V. V. Gorbachev,
D. S. Gorbunov,
W. C. Haxton,
T. V. Ibragimova,
I. Kim,
Yu. P. Kozlova,
L. V. Kravchuk,
V. V. Kuzminov,
B. K. Lubsandorzhiev,
Yu. M. Malyshkin,
R. Massarczyk,
V. A. Matveev,
I. N. Mirmov,
J. S. Nico,
A. L. Petelin,
R. G. H. Robertson,
D. Sinclair,
A. A. Shikhin
, et al. (5 additional authors not shown)
Abstract:
The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos, $ν_{e}$, observed in previous gallium-based radiochemical measurements with high-intensity neutrino sources, commonly referred to as the \textit{gallium anomaly}, which could be interpreted as evidence for oscillations between $ν_e$ and sterile neutrino ($ν_s$) states. A 3.414-MCi \nu…
▽ More
The Baksan Experiment on Sterile Transitions (BEST) was designed to investigate the deficit of electron neutrinos, $ν_{e}$, observed in previous gallium-based radiochemical measurements with high-intensity neutrino sources, commonly referred to as the \textit{gallium anomaly}, which could be interpreted as evidence for oscillations between $ν_e$ and sterile neutrino ($ν_s$) states. A 3.414-MCi \nuc{51}{Cr} $ν_e$ source was placed at the center of two nested Ga volumes and measurements were made of the production of \nuc{71}{Ge} through the charged current reaction, \nuc{71}{Ga}($ν_e$,e$^-$)\nuc{71}{Ge}, at two average distances. The measured production rates for the inner and the outer targets respectively are ($54.9^{+2.5}_{-2.4}(\mbox{stat})\pm1.4 (\mbox{syst})$) and ($55.6^{+2.7}_{-2.6}(\mbox{stat})\pm1.4 (\mbox{syst})$) atoms of \nuc{71}{Ge}/d. The ratio ($R$) of the measured rate of \nuc{71}{Ge} production at each distance to the expected rate from the known cross section and experimental efficiencies are $R_{in}=0.79\pm0.05$ and $R_{out}= 0.77\pm0.05$. The ratio of the outer to the inner result is 0.97$\pm$0.07, which is consistent with unity within uncertainty. The rates at each distance were found to be similar, but 20-24\% lower than expected, thus reaffirming the anomaly. These results are consistent with $ν_e \rightarrow ν_s$ oscillations with a relatively large $Δm^2$ ($>$0.5 eV$^2$) and mixing sin$^2 2θ$ ($\approx$0.4).
△ Less
Submitted 30 March, 2022; v1 submitted 23 September, 2021;
originally announced September 2021.
-
Direct Measurement of Backgrounds using Reactor-Off Data in Double Chooz
Authors:
Y. Abe,
C. Aberle,
J. C. dos Anjos,
J. C. Barriere,
M. Bergevin,
A. Bernstein,
T. J. C. Bezerra,
L. Bezrukhov,
E. Blucher,
N. S. Bowden,
C. Buck,
J. Busenitz,
A. Cabrera,
E. Caden,
L. Camilleri,
R. Carr,
M. Cerrada,
P. -J. Chang,
P. Chimenti,
T. Classen,
A. P. Collin,
E. Conover,
J. M. Conrad,
J. I. Crespo-Anadon,
K. Crum
, et al. (148 additional authors not shown)
Abstract:
Double Chooz is unique among modern reactor-based neutrino experiments studying $\bar ν_e$ disappearance in that data can be collected with all reactors off. In this paper, we present data from 7.53 days of reactor-off running. Applying the same selection criteria as used in the Double Chooz reactor-on oscillation analysis, a measured background rate of 1.0$\pm$0.4 events/day is obtained. The back…
▽ More
Double Chooz is unique among modern reactor-based neutrino experiments studying $\bar ν_e$ disappearance in that data can be collected with all reactors off. In this paper, we present data from 7.53 days of reactor-off running. Applying the same selection criteria as used in the Double Chooz reactor-on oscillation analysis, a measured background rate of 1.0$\pm$0.4 events/day is obtained. The background model for accidentals, cosmogenic $β$-$n$-emitting isotopes, fast neutrons from cosmic muons, and stopped-$μ$ decays used in the oscillation analysis is demonstrated to be correct within the uncertainties. Kinematic distributions of the events, which are dominantly cosmic-ray-produced correlated-background events, are provided. The background rates are scaled to the shielding depths of two other reactor-based oscillation experiments, Daya Bay and RENO.
△ Less
Submitted 20 October, 2012; v1 submitted 13 October, 2012;
originally announced October 2012.
-
An observation of a new class of afterpulses with delay time in the range of 70-200 microseconds in classical vacuum photomultipliers
Authors:
R. V. Poleshchuk,
B. K. Lubsandorzhiev,
R. V. Vasiliev
Abstract:
We present results of the first observation of afterpulses with extremely long (~120 microseconds) delay time from the main pulse in 8 inch classical vacuum photomultipliers.
We present results of the first observation of afterpulses with extremely long (~120 microseconds) delay time from the main pulse in 8 inch classical vacuum photomultipliers.
△ Less
Submitted 28 February, 2012;
originally announced February 2012.
-
The Quest for the Ideal Scintillator for Hybrid Phototubes
Authors:
B. K. Lubsandorzhiev,
B. Combettes
Abstract:
In this paper we present the results of extensive studies of scintillators for hybrid phototubes with luminescent screens. The results of the developments of such phototubes with a variety of scintillators are presented. New scintillator materials for such kind of application are discussed. The requirements for scintillators to use in such hybrid phototubes are formulated. It is shown that very…
▽ More
In this paper we present the results of extensive studies of scintillators for hybrid phototubes with luminescent screens. The results of the developments of such phototubes with a variety of scintillators are presented. New scintillator materials for such kind of application are discussed. The requirements for scintillators to use in such hybrid phototubes are formulated. It is shown that very fast and highly efficient inorganic scintillators like ZnO:Ga will be ideal scintillators for such kind of application.
△ Less
Submitted 10 October, 2007;
originally announced October 2007.
-
On the history of photomultiplier tube invention
Authors:
B. K. Lubsandorzhiev
Abstract:
In this very short note we review some historical aspects of photomultiplier tube invention. It is our tribute to the memory of great Soviet-Russian physicist and engineer Leonid Aleksandrovitch Kubetsky whose life and scientific achievements are described briefly. Particular efforts are made to shed light on a controversial issue of who invented the first photomultiplier tube. It is asserted th…
▽ More
In this very short note we review some historical aspects of photomultiplier tube invention. It is our tribute to the memory of great Soviet-Russian physicist and engineer Leonid Aleksandrovitch Kubetsky whose life and scientific achievements are described briefly. Particular efforts are made to shed light on a controversial issue of who invented the first photomultiplier tube. It is asserted that if to recognize L.A.Kubetsky's priority on the photomultiplier tube invention the last Beaune Conference would be held on the eve of the 75th Anniversary of that great event.
△ Less
Submitted 20 January, 2006;
originally announced January 2006.
-
Photoelectron backscattering in vacuum phototubes
Authors:
B. K. Lubsandorzhiev,
R. V. Vasiliev,
Y. E. Vyatchin,
B. A. J. Shaibonov
Abstract:
In this article we describe results of a photoelectron backscattering effect in vacuum phototubes: classical photomultipliers (PMT) and hybrid phototubes (PH). Late pulses occurring in PMTs are attributed to the photoelectron backscattering and distinguished from pulses due to an anode glow effect. The late pulses are measured in a number of PMTs and HPs with various photocathode sizes covering…
▽ More
In this article we describe results of a photoelectron backscattering effect in vacuum phototubes: classical photomultipliers (PMT) and hybrid phototubes (PH). Late pulses occurring in PMTs are attributed to the photoelectron backscattering and distinguished from pulses due to an anode glow effect. The late pulses are measured in a number of PMTs and HPs with various photocathode sizes covering 1-50 cm range and different types of the first dynode materials and construction designs. It is shown that the late pulses are a generic feature of all vacuum photodetectors - PMTs and PHs and they don't deteriorate dramatically amplitude and timing responses of vacuum phototubes.
△ Less
Submitted 20 January, 2006;
originally announced January 2006.