Skip to main content

Showing 1–9 of 9 results for author: LaBounty, J

Searching in archive nucl-ex. Search in all archives.
.
  1. arXiv:2506.03069  [pdf, ps, other

    hep-ex nucl-ex

    Measurement of the Positive Muon Anomalous Magnetic Moment to 127 ppb

    Authors: The Muon $g-2$ Collaboration, :, D. P. Aguillard, T. Albahri, D. Allspach, J. Annala, K. Badgley, S. Baeßler, I. Bailey, L. Bailey, E. Barlas-Yucel, T. Barrett, E. Barzi, F. Bedeschi, M. Berz, M. Bhattacharya, H. P. Binney, P. Bloom, J. Bono, E. Bottalico, T. Bowcock, S. Braun, M. Bressler, G. Cantatore, R. M. Carey , et al. (171 additional authors not shown)

    Abstract: A new measurement of the magnetic anomaly $a_μ$ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon $g-2$ Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with pr… ▽ More

    Submitted 3 June, 2025; originally announced June 2025.

    Comments: 11 pages, 3 figures; 2 pages of supplement material

    Report number: FERMILAB-PUB-25-0364-PPD

  2. arXiv:2409.14691  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Measurements of a LYSO crystal array from threshold to 100 MeV

    Authors: O. Beesley, J. Carlton, B. Davis-Purcell, D. Ding, S. Foster, K. Frahm, L. Gibbons, T. Gorringe, D. W. Hertzog, S. Hochrein, J. Hui, P. Kammel, J. LaBounty, J. Liu, R. Roehnelt, P. Schwendimann, A. Soter, E. Swanson, B. Taylor

    Abstract: We report measurements of ten custom-made high-homogeneity LYSO crystals. The investigation is motivated by the need for a compact, high-resolution, and fast electromagnetic calorimeter for a new rare pion decay experiment. Each $2.5\times 2.5 \times 18$ cm$^3$ crystal was first characterized for general light yield properties and then its longitudinal response uniformity and energy resolution wer… ▽ More

    Submitted 2 February, 2025; v1 submitted 22 September, 2024; originally announced September 2024.

    Comments: Minor editorial revision and additional table of manufacturer measurements

  3. arXiv:2402.15410  [pdf, other

    hep-ex hep-ph nucl-ex

    Detailed Report on the Measurement of the Positive Muon Anomalous Magnetic Moment to 0.20 ppm

    Authors: D. P. Aguillard, T. Albahri, D. Allspach, A. Anisenkov, K. Badgley, S. Baeßler, I. Bailey, L. Bailey, V. A. Baranov, E. Barlas-Yucel, T. Barrett, E. Barzi, F. Bedeschi, M. Berz, M. Bhattacharya, H. P. Binney, P. Bloom, J. Bono, E. Bottalico, T. Bowcock, S. Braun, M. Bressler, G. Cantatore, R. M. Carey, B. C. K. Casey , et al. (168 additional authors not shown)

    Abstract: We present details on a new measurement of the muon magnetic anomaly, $a_μ= (g_μ-2)/2$. The result is based on positive muon data taken at Fermilab's Muon Campus during the 2019 and 2020 accelerator runs. The measurement uses $3.1$ GeV$/c$ polarized muons stored in a $7.1$-m-radius storage ring with a $1.45$ T uniform magnetic field. The value of $ a_μ$ is determined from the measured difference b… ▽ More

    Submitted 22 May, 2024; v1 submitted 23 February, 2024; originally announced February 2024.

    Comments: 48 pages, 29 figures; 4 pages of Supplement Material; version accepted for publication in Physical Review D

    Report number: FERMILAB-PUB-24-0084-AD-CSAID-PPD

  4. Measurement of the Positive Muon Anomalous Magnetic Moment to 0.46 ppm

    Authors: B. Abi, T. Albahri, S. Al-Kilani, D. Allspach, L. P. Alonzi, A. Anastasi, A. Anisenkov, F. Azfar, K. Badgley, S. Baeßler, I. Bailey, V. A. Baranov, E. Barlas-Yucel, T. Barrett, E. Barzi, A. Basti, F. Bedeschi, A. Behnke, M. Berz, M. Bhattacharya, H. P. Binney, R. Bjorkquist, P. Bloom, J. Bono, E. Bottalico , et al. (212 additional authors not shown)

    Abstract: We present the first results of the Fermilab Muon g-2 Experiment for the positive muon magnetic anomaly $a_μ\equiv (g_μ-2)/2$. The anomaly is determined from the precision measurements of two angular frequencies. Intensity variation of high-energy positrons from muon decays directly encodes the difference frequency $ω_a$ between the spin-precession and cyclotron frequencies for polarized muons in… ▽ More

    Submitted 7 April, 2021; originally announced April 2021.

    Comments: 10 pages; 4 figures

    Report number: FERMILAB-PUB-21-132-E

    Journal ref: Phys. Rev. Lett. 126, 141801 (2021)

  5. Measurement of the anomalous precession frequency of the muon in the Fermilab Muon g-2 experiment

    Authors: T. Albahri, A. Anastasi, A. Anisenkov, K. Badgley, S. Baeßler, I. Bailey, V. A. Baranov, E. Barlas-Yucel, T. Barrett, A. Basti, F. Bedeschi, M. Berz, M. Bhattacharya, H. P. Binney, P. Bloom, J. Bono, E. Bottalico, T. Bowcock, G. Cantatore, R. M. Carey, B. C. K. Casey, D. Cauz, R. Chakraborty, S. P. Chang, A. Chapelain , et al. (153 additional authors not shown)

    Abstract: The Muon g-2 Experiment at Fermi National Accelerator Laboratory (FNAL) has measured the muon anomalous precession frequency $ω_a$ to an uncertainty of 434 parts per billion (ppb), statistical, and 56 ppb, systematic, with data collected in four storage ring configurations during its first physics run in 2018. When combined with a precision measurement of the magnetic field of the experiment's muo… ▽ More

    Submitted 7 April, 2021; originally announced April 2021.

    Comments: 29 pages, 19 figures. Published in Physical Review D

    Report number: FERMILAB-PUB-21-183-E

    Journal ref: Phys. Rev. D 103, 072002 (2021)

  6. Magnetic Field Measurement and Analysis for the Muon g-2 Experiment at Fermilab

    Authors: T. Albahri, A. Anastasi, K. Badgley, S. Baeßler, I. Bailey, V. A. Baranov, E. Barlas-Yucel, T. Barrett, F. Bedeschi, M. Berz, M. Bhattacharya, H. P. Binney, P. Bloom, J. Bono, E. Bottalico, T. Bowcock, G. Cantatore, R. M. Carey, B. C. K. Casey, D. Cauz, R. Chakraborty, S. P. Chang, A. Chapelain, S. Charity, R. Chislett , et al. (148 additional authors not shown)

    Abstract: The Fermi National Accelerator Laboratory has measured the anomalous precession frequency $a^{}_μ= (g^{}_μ-2)/2$ of the muon to a combined precision of 0.46 parts per million with data collected during its first physics run in 2018. This paper documents the measurement of the magnetic field in the muon storage ring. The magnetic field is monitored by nuclear magnetic resonance systems and calibrat… ▽ More

    Submitted 17 June, 2022; v1 submitted 7 April, 2021; originally announced April 2021.

    Comments: Added one citation and corrected missing normalization in Eqs (35) and (36)

    Report number: FERMILAB-PUB-21-109-E

    Journal ref: Phys. Rev. A 103, 042208 (2021)

  7. arXiv:1707.02361  [pdf, other

    physics.acc-ph nucl-ex physics.ins-det

    A Magnetic Field Cloak For Charged Particle Beams

    Authors: K. Capobianco-Hogan, R. Cervantes, A. Deshpande, N. Feege, T. Krahulik, J. LaBounty, R. Sekelsky, A. Adhyatman, G. Arrowsmith-Kron, B. Coe, K. Dehmelt, T. K. Hemmick, S. Jeffas, T. LaByer, S. Mahmud, A. Oliveira, A. Quadri, K. Sharma, A. Tishelman-Charny

    Abstract: Shielding charged particle beams from transverse magnetic fields is a common challenge for particle accelerators and experiments. We demonstrate that a magnetic field cloak is a viable solution. It allows for the use of dipole magnets in the forward regions of experiments at an Electron Ion Collider (EIC) and other facilities without interfering with the incoming beams. The dipoles can improve the… ▽ More

    Submitted 20 November, 2017; v1 submitted 6 July, 2017; originally announced July 2017.

    Journal ref: Nucl.Instrum.Meth. A877 (2018) 149-156

  8. arXiv:1704.01461  [pdf, other

    physics.ins-det hep-ex nucl-ex

    Design and Beam Test Results for the sPHENIX Electromagnetic and Hadronic Calorimeter Prototypes

    Authors: C. A. Aidala, V. Bailey, S. Beckman, R. Belmont, C. Biggs, J. Blackburn, S. Boose, M. Chiu, M. Connors, E. Desmond, A. Franz, J. S. Haggerty, X. He, M. M. Higdon, J. Huang, K. Kauder, E. Kistenev, J. LaBounty, J. G. Lajoie, M. Lenz, W. Lenz, S. Li, V. R. Loggins, E. J. Mannel, T. Majoros , et al. (25 additional authors not shown)

    Abstract: The super Pioneering High Energy Nuclear Interaction eXperiment (sPHENIX) at the Relativistic Heavy Ion Collider (RHIC) will perform high precision measurements of jets and heavy flavor observables for a wide selection of nuclear collision systems, elucidating the microscopic nature of strongly interacting matter ranging from nucleons to the strongly coupled quark-gluon plasma. A prototype of the… ▽ More

    Submitted 16 December, 2018; v1 submitted 5 April, 2017; originally announced April 2017.

    Comments: 19 pages, 31 figures, 3 tables. Published in IEEE Transactions on Nuclear Science (Volume: 65 , Issue: 12 , Dec. 2018 ). Revisions over previous version in response to referee and editor comments, plus updating of references and acknowledgement

    Journal ref: IEEE Transactions on Nuclear Science, Volume 65, Issue 12, pp. 2901-2919, December 2018

  9. arXiv:1311.3594  [pdf, other

    physics.ins-det hep-ex nucl-ex

    The PHENIX Forward Silicon Vertex Detector

    Authors: C. Aidala, L. Anaya, E. Anderssen, A. Bambaugh, A. Barron, J. G. Boissevain, J. Bok, S. Boose, M. L. Brooks, S. Butsyk, M. Cepeda, P. Chacon, S. Chacon, L. Chavez, T. Cote, C. D'Agostino, A. Datta, K. DeBlasio, L. DelMonte, E. J. Desmond, J. M. Durham, D. Fields, M. Finger, C. Gingu, B. Gonzales , et al. (60 additional authors not shown)

    Abstract: A new silicon detector has been developed to provide the PHENIX experiment with precise charged particle tracking at forward and backward rapidity. The Forward Silicon Vertex Tracker (FVTX) was installed in PHENIX prior to the 2012 run period of the Relativistic Heavy Ion Collider (RHIC). The FVTX is composed of two annular endcaps, each with four stations of silicon mini-strip sensors, covering a… ▽ More

    Submitted 14 February, 2014; v1 submitted 14 November, 2013; originally announced November 2013.

    Comments: version submitted to NIM