-
Measurement of Spectrum Averaged Cross Sections in LR-0 Benchmark Reference Neutron Field
Authors:
Michal Košťál,
Evžen Losa,
Stanislav Simakov,
Tomáš Czakoj,
Martin Schulc,
Jan Šimon,
Vojtěch Rypar,
Martin Mareček,
Jan Uhlíř,
Alena Krechlerová,
Tomáš Peltan,
Radek Pošvař,
Zdeněk Matěj,
David Bernard,
Andrej Trkov,
Roberto Capote
Abstract:
The measured and evaluated excitation functions are fundamental quantities that affect the accuracy of all calculations in nuclear applications. Some cross sections, such as 14N(n,p)14C, have added value for special applications, as these reactions may be responsible for possible contamination in industrial processes such as spent fuel reprocessing. For the validation of the evaluated cross sectio…
▽ More
The measured and evaluated excitation functions are fundamental quantities that affect the accuracy of all calculations in nuclear applications. Some cross sections, such as 14N(n,p)14C, have added value for special applications, as these reactions may be responsible for possible contamination in industrial processes such as spent fuel reprocessing. For the validation of the evaluated cross sections, we can rely on the comparison of the calculated spectrum averaged cross sections (SACS) for the given neutron spectrum with the measured SACS value. The benchmark reference neutron field has been identified, characterized, and well validated in the LR-0 special core. A very large set of SACS measurements in the LR0 reference field is measured with low uncertainty, making it an excellent set for deconvolution codes validation. The impact of the gamma-induced reaction on the production yield of neutron-induced reactions was investigated for most of the benchmarked reactions. Gamma competition was found to contribute at most 1% for the 197Au(n,2n) reaction, while being substantially lower for other target isotopes and neutron-induced activation reactions.
△ Less
Submitted 13 May, 2024;
originally announced July 2024.
-
FENDL: A library for fusion research and applications
Authors:
G. Schnabel,
D. L. Aldama,
T. Bohm,
U. Fischer,
S. Kunieda,
A. Trkov,
C. Konno,
R. Capote,
A. J. Koning,
S. Breidokaite,
T. Eade,
M. Fabbri,
D. Flammini,
L. Isolan,
I. Kodeli,
M. Košťál,
S. Kwon,
D. Laghi,
D. Leichtle,
S. Nakayama,
M. Ohta,
L. W. Packer,
Y. Qiu,
S. Sato,
M. Sawan
, et al. (6 additional authors not shown)
Abstract:
The Fusion Evaluated Nuclear Data Library (FENDL) is a comprehensive and validated collection of nuclear cross section data coordinated by the International Atomic Energy Agency (IAEA) Nuclear Data Section (NDS). FENDL assembles the best nuclear data for fusion applications selected from available nuclear data libraries and has been under development for decades. FENDL contains sub-libraries for i…
▽ More
The Fusion Evaluated Nuclear Data Library (FENDL) is a comprehensive and validated collection of nuclear cross section data coordinated by the International Atomic Energy Agency (IAEA) Nuclear Data Section (NDS). FENDL assembles the best nuclear data for fusion applications selected from available nuclear data libraries and has been under development for decades. FENDL contains sub-libraries for incident neutron, proton, and deuteron cross sections including general purpose and activation files used for particle transport and nuclide inventory calculations.
We describe the history, selection of evaluations for the various sub-libraries (neutron, proton, deuteron) with the focus on transport and reactor dosimetry applications, the processing of the nuclear data for application codes, and the development of the TENDL-2017 library which is the currently recommended activation library for FENDL. We briefly describe the IAEA IRDFF library as the recommended library for dosimetry fusion applications. We also present work on validation of the neutron sub-library using a variety of fusion relevant computational and experimental benchmarks. A variety of cross section libraries are used for the validation work including FENDL-2.1, FENDL-3.1d, FENDL-3.2, ENDF/B-VIII.0, and JEFF-3.2 with the emphasis on the FENDL libraries. The results of the experimental validation showed that the performance of FENDL-3.2b is at least as good and in most cases better than FENDL-2.1.
Future work will consider improved evaluations developed by the International Nuclear Data Evaluation Network (INDEN). Additional work will be needed to investigate differences in gas production in structural materials. Covariance matrices need to be updated to support the development of fusion technology. Additional validation work for high-energy neutrons, protons and deuterons, and the activation library will be needed.
△ Less
Submitted 17 November, 2023; v1 submitted 16 November, 2023;
originally announced November 2023.
-
Validation of IRDFF-II library in VR-1 reactor field using thin targets
Authors:
Michal Kostal,
Evzen Losa1,
Martin Schulc,
Jan Simon,
Tomas Bily,
Vojtech Rypar,
Martin Mareček,
Jan Uhlíř,
Tomáš Czakoj,
Roberto Capote,
Andrej Trkov,
Stanislav Simakov
Abstract:
Cross section data are fundamental quantities which affect the accuracy of all calculations in nuclear applications. A new dosimetry library IRDFF-II that contains cross section evaluations with full uncertainty quantification was developed by the International Atomic Energy Agency and released in January 2020 (https://www-nds.iea.org/IRDFF). A previous version, IRDFF-1.05, was released in 2014 an…
▽ More
Cross section data are fundamental quantities which affect the accuracy of all calculations in nuclear applications. A new dosimetry library IRDFF-II that contains cross section evaluations with full uncertainty quantification was developed by the International Atomic Energy Agency and released in January 2020 (https://www-nds.iea.org/IRDFF). A previous version, IRDFF-1.05, was released in 2014 and experimental validation of the newly released cross section by spectrum averaged cross section (SACS) measurements is a high priority task. For such purpose, a neutron dosimeter set containing 5 target foils was activated in 2 independent experiments at the VR-1 reactor of the Czech Technical University in Prague. Care was taken to derive SACS with low uncertainties. New experimental evaluation method is in good agreement with previous approaches based on relative measurements using monitor foils. Good agreement of measured SACS and evaluated IRDFF-II cross sections is observed. Slight overestimation of evaluated ENDF/B-VIII.0 235U(nth,f) PFNS above 10 MeV is discussed.
△ Less
Submitted 5 June, 2023;
originally announced June 2023.
-
The methodology for validation of cross sections in quasi monoenergetic neutron field
Authors:
Zdeněk Matěj,
Michal Košťál,
Mitja Majerle,
Martin Ansorge,
Evžen Losa,
Marek Zmeškal,
Martin Schulc,
Jan Šimon,
Milan Štefánik,
Jan Novák,
Daniil Koliadko,
František Cvachovec,
Filip Mravec,
Václav Přenosil,
Václav Zach,
Tomáš Czakoj,
Vojtěch Rypar,
Roberto Capote
Abstract:
Dosimetry cross sections are fundamental quantities essential in determination of neutron fluences in points of interest in technologies under heavy radiation load. The most common is their application to Reactor Pressure Vessel aging management, relating to correct estimation of its residual lifetime. The neutron spectrum in various reactor positions has a similar character as the fission spectru…
▽ More
Dosimetry cross sections are fundamental quantities essential in determination of neutron fluences in points of interest in technologies under heavy radiation load. The most common is their application to Reactor Pressure Vessel aging management, relating to correct estimation of its residual lifetime. The neutron spectrum in various reactor positions has a similar character as the fission spectrum. Due to this fact, the validation of the neutron dosimetry cross sections in reactor fields, or in a very well-known neutron field of 252Cf(s.f.) is sufficient for ensuring their validity in estimations of neutron fluxes in reactor physics. With an increasing field of applications, as in neutron dosimetry in accelerator-based fields or space applications, requests occurred on detailed validation in spectra different from fission ones. This paper presents the testing of a new methodology for the use of quasi monoenergetic neutron fields, where different sensitivity allows validations of the cross-section in different energy regions than in the fission spectrum. The exact shape of the neutron spectrum in the tested fields is determined by stilbene spectrometry and corrected to scattering by calculation, where applicable. The total flux is determined from Ni and Al flux monitors. The evaluated neutron flux in the target set of activation foils is used for calculation of theoretical reaction rate, which is compared with the experimental value determined from gamma activity. This kind of comparison can be understood as validation. It is worth noting, this methodology applied to the IRDFF-II library shows satisfactory agreement for selected reactions.
△ Less
Submitted 5 June, 2023;
originally announced June 2023.
-
Impact of Reactor Neutron Spectrum on Measured Spectrum Averaged Cross Sections
Authors:
Michal Kostal,
Evzen Losa,
Stanislav Simakov,
Martin Schulc,
Jan Simon,
Vojtech Rypar,
Martin Mareček,
Jan Uhlíř,
Tomáš Czakoj,
Andrej Trkov,
Roberto Capote
Abstract:
The cross section averaged over 235U thermal-neutron induced fission spectrum is a fundamental quantity that can be used in evaluation and validation of nuclear data. Many experiments focused on the determination of Spectrum Averaged Cross Sections (SACS) in 235U(nth,f). Prompt Fission Neutron Spectrum (PFNS) in light water reactors using enriched uranium fuel. In these reactors, there is already…
▽ More
The cross section averaged over 235U thermal-neutron induced fission spectrum is a fundamental quantity that can be used in evaluation and validation of nuclear data. Many experiments focused on the determination of Spectrum Averaged Cross Sections (SACS) in 235U(nth,f). Prompt Fission Neutron Spectrum (PFNS) in light water reactors using enriched uranium fuel. In these reactors, there is already some amount of water moderator between the uranium fuel and the irradiated sample. Due to the decrease of hydrogen cross-section with neutron energy, the high energy tail of the reactor spectrum in cores with water moderator may be harder than the pure PFNS. This paper aims to compare the shape of the actual reactor spectrum in various core positions of a research light-water reactor differing each from other by the effective water thickness. The spectrum shape is determined both by calculations and experimentally using various high energy threshold reactions. The impact of the photo-nuclear reactions (γ,n) competing with (n,2n) in production of the same residual nucleus was shown to be less than a percent for most of studied dosimeters. An important exception was found for 197Au(n,2n) 196Au dosimeter irradiated in the outcore channel where a notable photo-neutron contribution to the production of 196Au is caused by the neutron production from the high energy γ-rays from thermal-neutron capture in 54Fe. The corresponding ENDF/B-VIII.0 data turned out to underestimate such γ-yield by 40% in comparison with ENDF/B-VI.8. This has improved but however not resolved the disagreement between our measurement and calculations. The remaining deficiency was attributed to the underestimation of the evaluated cross section IAEA/PD-2019 for the 197Au(γ,n) cross section near the reaction threshold. The later was confirmed by comparison with existing measured data.
△ Less
Submitted 5 June, 2023;
originally announced June 2023.
-
Measurement of Dosimetrical Cross Sections with 14.05 MeV Neutrons From Compact Neutron Generator
Authors:
Michal Kostal,
Tomáš Czakoj,
Jan Simon,
Marek Zmeskal,
Martin Schulc,
Alena Krechlerova,
Tomáš Peltan,
Filip Mravec,
Frantisek Cvachovec,
Vojtěch Rypar,
Radim Uhlar,
Petr Alexa,
Ondrej Harkut,
Zdenek Matej
Abstract:
Dosimetry cross sections are fundamental quantities necessary for neutron dosimetry using the neutron activation method. It is worth noting that the uncertainty in cross sections is the major source of uncertainty in calculational predictions using nuclear data in simulations thus, cross section validation is a key issue in any aims for refinement of any predictions. A small compact neutron genera…
▽ More
Dosimetry cross sections are fundamental quantities necessary for neutron dosimetry using the neutron activation method. It is worth noting that the uncertainty in cross sections is the major source of uncertainty in calculational predictions using nuclear data in simulations thus, cross section validation is a key issue in any aims for refinement of any predictions. A small compact neutron generator is a promising tool for performing integral experiments and even for differential experiments. This paper deals with the measurement of the differential dosimetry cross sections using a small compact D-T neutron generator with 14.05 MeV neutron emission (10E8 n/s into 4pi). Achieving measurable activation at such a low flux field is allowed by using a larger amount of activation material placed in close measurement geometry during decay gamma measurement. The experimentally determined cross sections are in good agreement with the cross sections in the IRDFF-II dosimetry library. The comparison with other nuclear data libraries was performed as well. Its worth noting, the mean standard deviation in IRDFF-II library is about 4 %, while in case of other data libraries they are from 5.5 % - 7.5 %. This result can be understood as a validation of IRDFF-II using 14.05 MeV neutrons and also a confirmation of the applicability of small compact generators in the measurement of activation cross sections.
△ Less
Submitted 5 June, 2023;
originally announced June 2023.
-
Spectrum averaged cross section measurements of lutetium using standard 252Cf neutron source
Authors:
Martin Schulc,
Michal Kostal,
Tomas Czakoj,
Evzen Novak,
Jan Simon,
Nella Hynkova,
Roberto Capote
Abstract:
The spectrum averaged cross section (SACS) in standard neutron field is a preferable tool for cross section validation. There are very few measurements involving lutetium neutron cross sections. The presented work uses only neutron standard, i.e., 252Cf(sf) neutron field, for validation of lutetium threshold cross sections. SACS were inferred from gamma spectrometry derived reaction rates. The SAC…
▽ More
The spectrum averaged cross section (SACS) in standard neutron field is a preferable tool for cross section validation. There are very few measurements involving lutetium neutron cross sections. The presented work uses only neutron standard, i.e., 252Cf(sf) neutron field, for validation of lutetium threshold cross sections. SACS were inferred from gamma spectrometry derived reaction rates. The SACS which were derived include 175Lu(n,2n)174Lu, 175Lu(n,3n)173Lu, 175Lu(n,p)175Yb, and 176Lu(n,n)176m1Lu reactions. All these reactions SACS were measured for the first time. MCNP6 calculations using JEFF-3.3 or ENDF/B-VIII.0 libraries for lutetium cross sections were compared with experimental data. The agreement was found very poor for all reactions under study. Thus there is a need for their improvement. The presented data can be also used for validation of the various theoretical models.
△ Less
Submitted 5 June, 2023;
originally announced June 2023.
-
IRDFF-II: A New Neutron Metrology Library
Authors:
A. Trkov,
P. J. Griffin,
S. P. Simakov,
L. R. Greenwood,
K. I. Zolotarev,
R. Capote,
D. L. Aldama,
V. Chechev,
C. Destouches,
A. C. Kahler,
C. Konno,
M. Koštál,
M. Majerle,
E. Malambu,
M. Ohta,
V. G. Pronyaev,
V. Radulović,
S. Sato,
M. Schulc,
E. Šimečková,
I. Vavtar,
J. Wagemans,
M. White,
H. Yashima
Abstract:
High quality nuclear data is the most fundamental underpinning for all neutron metrology applications. This paper describes the release of version II of the International Reactor Dosimetry and Fusion File (IRDFF-II) that contains a consistent set of nuclear data for fission and fusion neutron metrology applications up to 60~MeV neutron energy. The library is intended to support: a) applications in…
▽ More
High quality nuclear data is the most fundamental underpinning for all neutron metrology applications. This paper describes the release of version II of the International Reactor Dosimetry and Fusion File (IRDFF-II) that contains a consistent set of nuclear data for fission and fusion neutron metrology applications up to 60~MeV neutron energy. The library is intended to support: a) applications in research reactors; b) safety and regulatory applications in the nuclear power generation in commercial fission reactors; and c) material damage studies in support of the research and development of advanced fusion concepts. The paper describes the contents of the library, documents the thorough verification process used in its preparation, and provides an extensive set of validation data gathered from a wide range of neutron benchmark fields. The new \mbox{IRDFF-II} library includes 119 metrology reactions, four cover material reactions to support self-shielding corrections, five metrology metrics used by the dosimetry community, and cumulative fission products yields for seven fission products in three different neutron energy regions. In support of characterizing the measurement of the residual nuclei from the dosimetry reactions and the fission product decay modes, the present document lists the recommended decay data, particle emission energies and probabilities for 68 activation products. It also includes neutron spectral characterization data for 29 neutron benchmark fields for the validation of the library contents. The IRDFF-II library and comprehensive documentation is available online at https://www-nds.iaea.org/IRDFF/. Evaluated cross sections can be compared with experimental data and other evaluations at https://www-nds.iaea.org/exfor/endf.htm. The new library is expected to become the international reference in neutron metrology for multiple applications.
△ Less
Submitted 21 October, 2019; v1 submitted 7 September, 2019;
originally announced September 2019.