Skip to main content

Showing 1–6 of 6 results for author: Komura, S

Searching in archive nucl-ex. Search in all archives.
.
  1. arXiv:1702.01484  [pdf

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    First On-Site True Gamma-Ray Imaging-Spectroscopy of Contamination near Fukushima Plant

    Authors: Dai Tomono, Tetsuya Mizumoto, Atsushi Takada, Shotaro Komura, Yoshihiro Matsuoka, Yoshitaka Mizumura, Makoto Oda, Toru Tanimori

    Abstract: We have developed an Electron Tracking Compton Camera (ETCC), which provides a well-defined Point Spread Function (PSF) by reconstructing a direction of each gamma as a point and realizes simultaneous measurement of brightness and spectrum of MeV gamma-rays for the first time. Here, we present the results of our on-site pilot gamma-imaging-spectroscopy with ETCC at three contaminated locations in… ▽ More

    Submitted 5 February, 2017; originally announced February 2017.

    Comments: 19 pages, 7 figures, 2 tables

    Journal ref: Scientific Reports 7, 41972 (2017)

  2. arXiv:1702.01483  [pdf

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics

    Authors: Toru Tanimori, Yoshitaka Mizumura, Atsushi Takada, Shohei Miyamoto, Taito Takemura, Tetsuro Kishimoto, Shotaro Komura, Hidetoshi Kubo, Shunsuke Kurosawa, Yoshihiro Matsuoka, Kentaro Miuchi, Tetsuya Mizumoto, Yuma Nakamasu, Kiseki Nakamura, Joseph D. Parker, Tatsuya Sawano, Shinya Sonoda, Dai Tomono, Kei Yoshikawa

    Abstract: Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, whic… ▽ More

    Submitted 5 February, 2017; originally announced February 2017.

    Comments: 22 pages, 8 figures

    Journal ref: Scientific Reports 7, 41511 (2017)

  3. arXiv:1508.01287  [pdf, ps, other

    physics.ins-det astro-ph.IM hep-ex nucl-ex

    A performance study of an electron-tracking Compton camera with a compact system for environmental gamma-ray observation

    Authors: Tetsuya Mizumoto, Dai Tomono, Atsushi Takada, Toru Tanimori, Shotaro Komura, Hidetoshi Kubo, Yoshihiro Matsuoka, Yoshitaka Mizumura, Kiseki Nakamura, Shogo Nakamura, Makoto Oda, Joseph D. Parker, Tatsuya Sawano, Naoto Bando, Akira Nabetani

    Abstract: An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the sc… ▽ More

    Submitted 6 August, 2015; originally announced August 2015.

    Comments: 10 pages, 7 figures, proceeding of the 10th International Conference on Position Sensitive Detectors (PSD10)

    Journal ref: JINST 10 (2015) C06003

  4. arXiv:1508.00990  [pdf, ps, other

    astro-ph.IM astro-ph.CO astro-ph.HE hep-ex nucl-ex

    New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)

    Authors: Tetsuya Mizumoto, Yoshihiro Matsuoka, Yoshitaka Mizumura, Toru Tanimori, Hidetoshi Kubo, Atsushi Takada, Satoru Iwaki, Tatsuya Sawano, Kiseki Nakamura, Shotaro Komura, Shogo Nakamura, Tetsuro Kishimoto, Makoto Oda, Shohei Miyamoto, Taito Takemura, Joseph D. Parker, Dai Tomono, Shinya Sonoda, Kentaro Miuchi, Shunsuke Kurosawa

    Abstract: For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for d… ▽ More

    Submitted 29 August, 2015; v1 submitted 5 August, 2015; originally announced August 2015.

    Comments: 11 pages, 24 figures

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A 800 (2015) 40-50

  5. arXiv:1507.03850  [pdf, ps, other

    astro-ph.IM astro-ph.CO astro-ph.HE hep-ex nucl-ex

    An Electron-Tracking Compton Telescope for a Survey of the Deep Universe by MeV gamma-rays

    Authors: T. Tanimori, H. Kubo, A. Takada, S. Iwaki, S. Komura, S. Kurosawa, Y. Matsuoka, K. Miuchi, S. Miyamoto, T. Mizumoto, Y. Mizumura, K. Nakamura, S. Nakamura, M. Oda, J. D. Parker, T. Sawano, S. Sonoda, T. Takemura, D. Tomono, K. Ueno

    Abstract: Photon imaging for MeV gammas has serious difficulties due to huge backgrounds and unclearness in images, which are originated from incompleteness in determining the physical parameters of Compton scattering in detection, e.g., lack of the directional information of the recoil electrons. The recent major mission/instrument in the MeV band, Compton Gamma Ray Observatory/COMPTEL, which was Compton C… ▽ More

    Submitted 4 August, 2015; v1 submitted 14 July, 2015; originally announced July 2015.

    Comments: 19 pages, 12 figures, Accepted to the Astrophysical Journal

    Journal ref: ApJ, 810 (2015), 28

  6. arXiv:1412.3918  [pdf, ps, other

    astro-ph.IM hep-ex nucl-ex physics.ins-det

    Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam

    Authors: Yoshihiro Matsuoka, T. Tanimori, H. Kubo, A. Takada, J. D. Parker, T. Mizumoto, Y. Mizumura, S. Iwaki, T. Sawano, S. Komura, T. Kishimoto, M. Oda, T. Takemura, S. Miyamoto, S. Sonoda, D. Tomono, K. Miuchi, S. Kabuki, S. Kurosawa

    Abstract: We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient back… ▽ More

    Submitted 22 January, 2015; v1 submitted 12 December, 2014; originally announced December 2014.

    Comments: 10 pages, 8figures, http://www-cr.scphys.kyoto-u.ac.jp/research/MeV-gamma/wiki/wiki.cgi , PSD10