A study on energy resolution of CANDLES detector
Authors:
B. T. Khai,
S. Ajimura,
W. M. Chan,
K. Fushimi,
R. Hazama,
H. Hiraoka,
T. Iida,
K. Kanagawa,
H. Kino,
T. Kishimoto,
T. Maeda,
K. Nakajima,
M. Nomachi,
I. Ogawa,
T. Ohata,
K. Suzuki,
Y. Takemoto,
Y. Takihira,
Y. Tamagawa,
M. Tozawa,
M. Tsuzuki,
S. Umehara,
S. Yoshida
Abstract:
In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value…
▽ More
In a neutrinoless double-beta decay ($0νββ$) experiment, energy resolution is important to distinguish between $0νββ$ and background events. CAlcium fluoride for studies of Neutrino and Dark matters by Low Energy Spectrometer (CANDLES) discerns the $0νββ$ of $^{48}$Ca using a CaF$_2$ scintillator as the detector and source. Photomultiplier tubes (PMTs) collect scintillation photons. At the Q-value of $^{48}$Ca, the current energy resolution (2.6%) exceeds the ideal statistical fluctuation of the number of photoelectrons (1.6%). Because of CaF$_2$'s long decay constant of 1000 ns, a signal integration within 4000 ns is used to calculate the energy. The baseline fluctuation ($σ_{baseline}$) is accumulated in the signal integration, thus degrading the energy resolution. This paper studies $σ_{baseline}$ in the CANDLES detector, which severely degrades the resolution by 1% at the Q-value of $^{48}$Ca. To avoid $σ_{\rm baseline}$, photon counting can be used to obtain the number of photoelectrons in each PMT; however, a significant photoelectron signal overlapping probability in each PMT causes missing photoelectrons in counting and reduces the energy resolution. "Partial photon counting" reduces $σ_{baseline}$ and minimizes photoelectron loss. We obtain improved energy resolutions of 4.5-4.0% at 1460.8 keV ($γ$-ray of $^{40}$K), and 3.3-2.9% at 2614.5 keV ($γ$-ray of $^{208}$Tl). The energy resolution at the Q-value is estimated to be improved from 2.6% to 2.2%, and the detector sensitivity for the $0νββ$ half-life of $^{48}$Ca can be improved by 1.09 times.
△ Less
Submitted 28 January, 2021; v1 submitted 24 September, 2020;
originally announced September 2020.
-
Low background measurement in CANDLES-III for studying the neutrino-less double beta decay of $^{48}$Ca
Authors:
S. Ajimura,
W. M. Chan,
K. Ichimura,
T. Ishikawa,
K. Kanagawa,
B. T. Khai,
T. Kishimoto,
H. Kino,
T. Maeda,
K. Matsuoka,
N. Nakatani,
M. Nomachi,
M. Saka,
K. Seki,
Y. Takemoto,
Y. Takihira,
D. Tanaka,
M. Tanaka,
K. Tetsuno,
V. T. T. Trang,
M. Tsuzuki,
S. Umehara,
K. Akutagawa,
T. Batpurev,
M. Doihara
, et al. (44 additional authors not shown)
Abstract:
We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal background…
▽ More
We developed a CANDLES-III system to study the neutrino-less double beta (0$νββ$) decay of $^{48}$Ca. The proposed system employs 96 CaF$_{2}$ scintillation crystals (305 kg) with natural Ca ($^{\rm nat.}$Ca) isotope which corresponds 350\,g of $^{48}$Ca. External backgrounds were rejected using a 4$π$ active shield of a liquid scintillator surrounding the CaF$_2$ crystals. The internal backgrounds caused by the radioactive impurities within the CaF$_2$ crystals can be reduced effectively through analysis of the signal pulse shape. We analyzed the data obtained in the Kamioka underground for a live-time of 130.4\,days to evaluate the feasibility of the low background measurement with the CANDLES-III detector. Using Monte Carlo simulations, we estimated the background rate from the radioactive impurities in the CaF$_{2}$ crystals and the rate of high energy $γ$-rays caused by the (n, $γ$) reactions induced by environmental neutrons. The expected background rate was in a good agreement with the measured rate, i.e., approximately 10$^{-3}$ events/keV/yr/(kg of $^{\rm nat.}$Ca), in the 0$νββ$ window. In conclusion, the background candidates were estimated properly by comparing the measured energy spectrum with the background simulations. With this measurement method, we performed the first search for 0$νββ$ decay in a low background condition using a detector with a Ca isotope, in which the Ca present was not enriched, in a scale of hundreds of kg. The $^{48}$Ca isotope has a high potential for use in 0$νββ$ decay search, and is expected to be useful for the development of a next-generation detector for highly sensitive measurements.
△ Less
Submitted 19 April, 2021; v1 submitted 20 August, 2020;
originally announced August 2020.
-
The energy calibration system for CANDLES using (n, γ) reaction
Authors:
T. Iida,
K. Mizukoshi,
T. Ohata,
T. Uehara,
T. Batpurev,
W. M. Chan,
K. Fushimi,
R. Hazama,
M. Ishikawa,
H. Kakubata,
K. Kanagawa,
S. Katagiri,
B. T. Khai,
T. Kishimoto,
X. Li,
T. Maeda,
K. Matsuoka,
K. Morishita,
M. Moser,
K. Nakajima,
M. Nomachi,
I. Ogawa,
M. Shokati,
K. Suzuki,
Y. Takemoto
, et al. (6 additional authors not shown)
Abstract:
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of…
▽ More
CAlcium fluoride for the study of Neutrinos and Dark matters by Low-energy Spectrometer (CANDLES) searches for neutrino-less double beta decay of $^{48}$Ca using a CaF$_2$ scintillator array. A high Q-value of $^{48}$Ca at 4,272 keV enabled us to achieve very low background condition, however, at the same it causes difficulties in calibrating the detector's Q-value region because of the absence of a standard high-energy $γ$-ray source. Therefore, we have developed a novel calibration system based on $γ$-ray emission by neutron capture on $^{28}$Si, $^{56}$Fe and $^{58}$Ni nuclei. In the paper, we report the development of the new calibration system as well as the results of energy calibration in CANDLES up to 9 MeV.
△ Less
Submitted 26 March, 2020;
originally announced March 2020.
-
Establishment of Imaging Spectroscopy of Nuclear Gamma-Rays based on Geometrical Optics
Authors:
Toru Tanimori,
Yoshitaka Mizumura,
Atsushi Takada,
Shohei Miyamoto,
Taito Takemura,
Tetsuro Kishimoto,
Shotaro Komura,
Hidetoshi Kubo,
Shunsuke Kurosawa,
Yoshihiro Matsuoka,
Kentaro Miuchi,
Tetsuya Mizumoto,
Yuma Nakamasu,
Kiseki Nakamura,
Joseph D. Parker,
Tatsuya Sawano,
Shinya Sonoda,
Dai Tomono,
Kei Yoshikawa
Abstract:
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, whic…
▽ More
Since the discovery of nuclear gamma-rays, its imaging has been limited to pseudo imaging, such as Compton Camera (CC) and coded mask. Pseudo imaging does not keep physical information (intensity, or brightness in Optics) along a ray, and thus is capable of no more than qualitative imaging of bright objects. To attain quantitative imaging, cameras that realize geometrical optics is essential, which would be, for nuclear MeV gammas, only possible via complete reconstruction of the Compton process. Recently we have revealed that "Electron Tracking Compton Camera" (ETCC) provides a well-defined Point Spread Function (PSF). The information of an incoming gamma is kept along a ray with the PSF and that is equivalent to geometrical optics. Here we present an imaging-spectroscopic measurement with the ETCC. Our results highlight the intrinsic difficulty with CCs in performing accurate imaging, and show that the ETCC surmounts this problem. The imaging capability also helps the ETCC suppress the noise level dramatically by ~3 orders of magnitude without a shielding structure. Furthermore, full reconstruction of Compton process with the ETCC provides spectra free of Compton edges. These results mark the first proper imaging of nuclear gammas based on the genuine geometrical optics.
△ Less
Submitted 5 February, 2017;
originally announced February 2017.
-
New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)
Authors:
Tetsuya Mizumoto,
Yoshihiro Matsuoka,
Yoshitaka Mizumura,
Toru Tanimori,
Hidetoshi Kubo,
Atsushi Takada,
Satoru Iwaki,
Tatsuya Sawano,
Kiseki Nakamura,
Shotaro Komura,
Shogo Nakamura,
Tetsuro Kishimoto,
Makoto Oda,
Shohei Miyamoto,
Taito Takemura,
Joseph D. Parker,
Dai Tomono,
Shinya Sonoda,
Kentaro Miuchi,
Shunsuke Kurosawa
Abstract:
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for d…
▽ More
For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$ TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$ medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.
△ Less
Submitted 29 August, 2015; v1 submitted 5 August, 2015;
originally announced August 2015.
-
Performance of a new electron-tracking Compton camera under intense radiations from a water target irradiated with a proton beam
Authors:
Yoshihiro Matsuoka,
T. Tanimori,
H. Kubo,
A. Takada,
J. D. Parker,
T. Mizumoto,
Y. Mizumura,
S. Iwaki,
T. Sawano,
S. Komura,
T. Kishimoto,
M. Oda,
T. Takemura,
S. Miyamoto,
S. Sonoda,
D. Tomono,
K. Miuchi,
S. Kabuki,
S. Kurosawa
Abstract:
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient back…
▽ More
We have developed an electron-tracking Compton camera (ETCC) for use in next-generation MeV gamma ray telescopes. An ETCC consists of a gaseous time projection chamber (TPC) and pixel scintillator arrays (PSAs). Since the TPC measures the three dimensional tracks of Compton-recoil electrons, the ETCC can completely reconstruct the incident gamma rays. Moreover, the ETCC demonstrates efficient background rejection power in Compton-kinematics tests, identifies particle from the energy deposit rate (dE/dX) registered in the TPC, and provides high quality imaging by completely reconstructing the Compton scattering process. We are planning the "Sub-MeV gamma ray Imaging Loaded-on-balloon Experiment" (SMILE) for our proposed all-sky survey satellite. Performance tests of a mid-sized 30 cm-cubic ETCC, constructed for observing the Crab nebula, are ongoing. However, observations at balloon altitudes or satellite orbits are obstructed by radiation background from the atmosphere and the detector itself. The background rejection power was checked using proton accelerator experiments conducted at the Research Center for Nuclear Physics, Osaka University. To create the intense radiation fields encountered in space, which comprise gamma rays, neutrons, protons, and other energetic entities, we irradiated a water target with a 140 MeV proton beam and placed a SMILE-II ETCC near the target. In this situation, the counting rate was five times than that expected at the balloon altitude. Nonetheless, the ETCC stably operated and identified particles sufficiently to obtain a clear gamma ray image of the checking source. Here, we report the performance of our detector and demonstrate its effective background rejection based in electron tracking experiments.
△ Less
Submitted 22 January, 2015; v1 submitted 12 December, 2014;
originally announced December 2014.
-
Search for a bound state of kaon and pion
Authors:
T. Kishimoto,
F. Khanam,
T. Hayakawa,
S. Ajimura,
T. Itabashi,
K. Matsuoka,
S. Minami,
Y. Mitoma,
A. Sakaguchi,
Y. Shimizu,
K. Terai,
T. Sato,
H. Noumi,
M. Sekimoto,
H. Takahashi,
T. Fukuda,
W. Imoto,
Y. Mizoi
Abstract:
We have searched for a bound state of kaon and pion denoted by $X$. The $X$ was conjectured to explain the so-called $Θ^+$ resonance as a bound state of kaon, pion and nucleon. This model explains almost all properties of the $Θ^+$, however, the model works only if the $K π$ interaction is strongly attractive. It is so strong that it could make a bound state $X$. Here we report a result of the sea…
▽ More
We have searched for a bound state of kaon and pion denoted by $X$. The $X$ was conjectured to explain the so-called $Θ^+$ resonance as a bound state of kaon, pion and nucleon. This model explains almost all properties of the $Θ^+$, however, the model works only if the $K π$ interaction is strongly attractive. It is so strong that it could make a bound state $X$. Here we report a result of the search for the $X$ by using the $K^+ + N \rightarrow X^+ + N$ reaction at P$_K\sim$ 1.2 GeV/c. The $X^+ \rightarrow K^+ γγ$ decay produces $K^+$ in momentum region where other processes cannot fill. We observed signature of the $X^+$ with statistical significance of 2 $σ$. Production cross section of $X$ with respect to that of $π^0$ is 1$\pm$0.5% if we take it as an evidence and 1.5% if we set an upper limit.
△ Less
Submitted 27 September, 2012;
originally announced September 2012.
-
Production of Neutron-Rich Lambda Hypernuclei at J-PARC
Authors:
A. Sakaguchi,
S. Ajimura,
H. Bhang,
L. Busso,
M. Endo,
D. Faso,
T. Fukuda,
T. Kishimoto,
K. Matsuda,
K. Matsuoka,
Y. Mizoi,
O. Morra,
H. Noumi,
P. K. Saha,
C. Samanta,
Y. Shimizu,
T. Takahashi,
T. N. Takahashi,
K. Yoshida
Abstract:
We discuss the usefulness of the double charge-exchange reactions (DCX) for the production of the neutron-rich Lambda-hypernuclei. We believe the (pi-,K+) reaction is one of the most promising DCX reactions, and propose to produce the neutron-rich Lambda-hypernuclei, 6(Lambda)H and 9(Lambda)He, at the J-PARC 50 GeV PS by the reaction (J-PARC E10 experiment). The design of the experiment is prese…
▽ More
We discuss the usefulness of the double charge-exchange reactions (DCX) for the production of the neutron-rich Lambda-hypernuclei. We believe the (pi-,K+) reaction is one of the most promising DCX reactions, and propose to produce the neutron-rich Lambda-hypernuclei, 6(Lambda)H and 9(Lambda)He, at the J-PARC 50 GeV PS by the reaction (J-PARC E10 experiment). The design of the experiment is presented.
△ Less
Submitted 1 April, 2009;
originally announced April 2009.
-
Neutrino-less Double Beta Decay of 48Ca studied by CaF2(Eu) Scintillators
Authors:
S. Umehara,
T. Kishimoto,
I. Ogawa,
R. Hazama,
H. Miyawaki,
S. Yoshida,
K. Matsuoka,
K. Kishimoto,
A. Katsuki,
H. Sakai,
D. Yokoyama,
K. Mukaida,
S. Tomii,
Y. Tatewaki,
T. Kobayashi,
A. Yanagisawa
Abstract:
We searched for the neutrino-less double beta decay(0nbb) of 48Ca by using CaF2(Eu) scintillators. Analysis of their pulse shapes was effective to reduce backgrounds. No events are observed in the Q-value region for the data of 3394 kg days. It gives a lower limit (90% confidence level) of T > 2.7 x 10^22 year for the half life of 0nbb of 48Ca. Combined with our previous data for 1553 kg days, w…
▽ More
We searched for the neutrino-less double beta decay(0nbb) of 48Ca by using CaF2(Eu) scintillators. Analysis of their pulse shapes was effective to reduce backgrounds. No events are observed in the Q-value region for the data of 3394 kg days. It gives a lower limit (90% confidence level) of T > 2.7 x 10^22 year for the half life of 0nbb of 48Ca. Combined with our previous data for 1553 kg days, we obtained more stringent limit of T > 5.8 x 10^22 year.
△ Less
Submitted 27 October, 2008;
originally announced October 2008.
-
Challenge on Ca-48 enrichment for CANDLES double beta decay experiment
Authors:
R. Hazama,
Y. Tatewaki,
T. Kishimoto,
K. Matsuoka,
N. Endo,
K. Kume,
Y. Shibahara,
M. Tanimizu
Abstract:
Chemical isotope effects of calcium were studied by liquid-liquid extraction using a crown ether of dicyclohexano-18-crown-6 for the purpose of finding a cost-effective and efficient way of enrichment of Ca-48 towards the study of the neutrinoless double beta decay of Ca-48. We evaluated each contribution ratio of the field shift effect and the hyperfine splitting shift effect to the mass effect…
▽ More
Chemical isotope effects of calcium were studied by liquid-liquid extraction using a crown ether of dicyclohexano-18-crown-6 for the purpose of finding a cost-effective and efficient way of enrichment of Ca-48 towards the study of the neutrinoless double beta decay of Ca-48. We evaluated each contribution ratio of the field shift effect and the hyperfine splitting shift effect to the mass effect of the calcium isotopes for the first time. The present preliminary result suggests the contribution of the field shift effect is small, especially for Ca-40-Ca-48 case, compared with the case of Chromium trichloride-crown in which the isotope enrichment factors are strongly affected by the field shifts. These indications are promising towards the mass producion of enriched Ca-48 by the chemical separation method.
△ Less
Submitted 20 October, 2007;
originally announced October 2007.
-
Neutrinoless double beta decay and direct searches for neutrino mass
Authors:
Craig Aalseth,
Henning Back,
Loretta Dauwe,
David Dean,
Guido Drexlin,
Yuri Efremenko,
Hiro Ejiri,
Steven Elliott,
Jon Engel,
Brian Fujikawa,
Reyco Henning,
G. W. Hoffmann,
Karol Lang,
Kevin Lesko,
Tadafumi Kishimoto,
Harry Miley,
Rick Norman,
Silvia Pascoli,
Serguey Petcov,
Andreas Piepke,
Werner Rodejohann,
David Saltzberg,
Sean Sutton,
Petr Vogel,
Ray Warner
, et al. (2 additional authors not shown)
Abstract:
Study of the neutrinoless double beta decay and searches for the manifestation of the neutrino mass in ordinary beta decay are the main sources of information about the absolute neutrino mass scale, and the only practical source of information about the charge conjugation properties of the neutrinos. Thus, these studies have a unique role in the plans for better understanding of the whole fast e…
▽ More
Study of the neutrinoless double beta decay and searches for the manifestation of the neutrino mass in ordinary beta decay are the main sources of information about the absolute neutrino mass scale, and the only practical source of information about the charge conjugation properties of the neutrinos. Thus, these studies have a unique role in the plans for better understanding of the whole fast expanding field of neutrino physics.
△ Less
Submitted 20 December, 2004;
originally announced December 2004.
-
Mesonic and nonmesonic weak decay widths of medium-heavy lambda hypernuclei
Authors:
Y. Sato,
S. Ajimura,
K. Aoki,
H. Bhang,
T. Hasegawa,
O. Hashimoto,
H. Hotchi,
Y. D. Kim,
T. Kishimoto,
K. Maeda,
H. Noumi,
Y. Ohta,
K. Omata,
H. Outa,
H. Park,
M. Sekimoto,
T. Shibata,
T. Takahashi,
M. Youn
Abstract:
We have measured the energy spectra of pions and protons emitted in the weak decay of 12_Lambda_C, 28_Lambda_Si, and Lambda_Fe hypernuclei produced via the (pi+, K+) reaction. The decay widths of the pi- mesonic decay (Lambda -> p + pi-) and the nonmesonic decay (Lambda + N -> N + N) were extracted. The present results demonstrate an increase of the mesonic decay width due to a distortion of the…
▽ More
We have measured the energy spectra of pions and protons emitted in the weak decay of 12_Lambda_C, 28_Lambda_Si, and Lambda_Fe hypernuclei produced via the (pi+, K+) reaction. The decay widths of the pi- mesonic decay (Lambda -> p + pi-) and the nonmesonic decay (Lambda + N -> N + N) were extracted. The present results demonstrate an increase of the mesonic decay width due to a distortion of the pion wave function in nuclear medium for the first time. The ratios of the neutron- to proton-induced nonmesonic decay widths, Gamma_n(Lambda + n -> n + n)/Gamma_p(Lambda + p -> n + p), were evaluated by a direct comparison of the measured proton energy spectra with the calculated ones. No theoretical calculation which has been proposed so far can simultaneously account for both the nonmesonic decay widths and the Gamma_n/Gamma_p ratios in the present data.
△ Less
Submitted 14 March, 2005; v1 submitted 11 September, 2004;
originally announced September 2004.
-
Study of the Sigma-nucleus potential by the (pi^-,K^+) reaction on medium-to-heavy nuclear targets
Authors:
P. K. Saha,
H. Noumi,
D. Abe,
S. Ajimura,
K. Aoki,
H. C. Bhang,
K. Dobashi,
T. Endo,
Y. Fujii,
T. Fukuda,
H. C. Guo,
O. Hashimoto,
H. Hotchi,
K. Imai,
E. H. Kim,
J. H. Kim,
T. Kishimoto,
A. Krutenkova,
K. Maeda,
T. Nagae,
M Nakamura,
H. Outa,
T. Saito,
A. Sakaguchi,
Y. Sato
, et al. (12 additional authors not shown)
Abstract:
In order to study the Sigma-nucleus optical potential, we measured inclusive (pi^-,K^+) spectra on medium-to-heavy nuclear targets: CH_2, Si, Ni, In and Bi. The CH_2 target was used to calibrate the excitation energy scale by using the elementary process p + pi^- -> K^+ + Sigma^-, where the C spectrum was also extracted. The calibration was done with +-0.1 MeV precision. The angular distribution…
▽ More
In order to study the Sigma-nucleus optical potential, we measured inclusive (pi^-,K^+) spectra on medium-to-heavy nuclear targets: CH_2, Si, Ni, In and Bi. The CH_2 target was used to calibrate the excitation energy scale by using the elementary process p + pi^- -> K^+ + Sigma^-, where the C spectrum was also extracted. The calibration was done with +-0.1 MeV precision. The angular distribution of the elementary cross section was measured, and agreed well with the previous bubble chamber data, but with better statistics, and the magnitudes of the cross sections of the measured inclusive (pi^-,K^+) spectra were also well calibrated. All of the inclusive spectra were found to be similar in shape at a region near to the Sigma^- binding energy threshold, showing a weak mass-number dependence on the magnitude of the cross section. The measured spectra were compared with a theoretical calculation performed within the framework of the Distorted Wave Impulse Approximation (DWIA). It has been demonstrated that a strongly repulsive \sig-nucleus potential with a non-zero size of the imaginary part is required to reproduce the shape of the measured spectra.
△ Less
Submitted 26 May, 2004;
originally announced May 2004.
-
Scintillation efficiency of nuclear recoils in a CaF-2(Eu) crystal for dark matter search
Authors:
R. Hazama,
S. Ajimura,
H. Hayakawa,
K. Matsuoka,
H. Miyawaki,
K. Morikubo,
N. Suzuki,
T. Kishimoto
Abstract:
The scintillation efficiency (quenching factor) of fluorine and calcium nuclei recoiling in a CaF-2(Eu) crystal was measured in an energy region relevant to dark matter searches. The recoiling nuclei were obtained via the 19-F(n,n') and 40-Ca(n,n') reactions, where the neutron beam was provided via the d(d,n)3-He reaction. The quenching factor of F and Ca nuclei in the CaF-2(Eu) crystal was foun…
▽ More
The scintillation efficiency (quenching factor) of fluorine and calcium nuclei recoiling in a CaF-2(Eu) crystal was measured in an energy region relevant to dark matter searches. The recoiling nuclei were obtained via the 19-F(n,n') and 40-Ca(n,n') reactions, where the neutron beam was provided via the d(d,n)3-He reaction. The quenching factor of F and Ca nuclei in the CaF-2(Eu) crystal was found to be 11 ~ 20 %, and 9 ~ 23 % relative to the electron equivalent energy for 53 ~ 192 keV and 25 ~ 91 keV recoil energies, respectively, and the energy dependence was observed. The quenching factor we measured here is a little larger than that of previous studies, which may depend on the Eu doping concentration of the crystal.
△ Less
Submitted 2 July, 2001;
originally announced July 2001.