-
Antenna Arrays for CRES-based Neutrino Mass Measurement
Authors:
A. Ashtari Esfahani,
S. Bhagvati,
S. Böser,
M. J. Brandsema,
N. Buzinsky,
R. Cabral,
C. Claessens,
L. de Viveiros,
A. El Boustani,
M. G. Elliott,
M. Fertl,
J. A. Formaggio,
B. T. Foust,
J. K. Gaison,
M. Gödel,
M. Grando,
P. Harmston,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
B. J. P. Jones,
E. Karim,
K. Kazkaz,
P. T. Kolbeck
, et al. (43 additional authors not shown)
Abstract:
CRES is a technique for precision measurements of kinetic energies of charged particles, pioneered by the Project 8 experiment to measure the neutrino mass using the tritium endpoint method. It was recently employed for the first time to measure the molecular tritium spectrum and place a limit on the neutrino mass using a cm$^3$-scale detector. Future direct neutrino mass experiments are developin…
▽ More
CRES is a technique for precision measurements of kinetic energies of charged particles, pioneered by the Project 8 experiment to measure the neutrino mass using the tritium endpoint method. It was recently employed for the first time to measure the molecular tritium spectrum and place a limit on the neutrino mass using a cm$^3$-scale detector. Future direct neutrino mass experiments are developing the technique to overcome the systematic and statistical limitations of current detectors. This paper describes one such approach, namely the use of antenna arrays for CRES in free space. Phenomenology, detector design, simulation, and performance estimates are discussed, culminating with an example design with a projected sensitivity of $m_β < 0.04 \ \mathrm{eV}/c^2$. Prototype antenna array measurements are also shown for a demonstrator-scale setup as a benchmark for the simulation. By consolidating these results, this paper serves as a comprehensive reference for the development and performance of antenna arrays for CRES.
△ Less
Submitted 21 April, 2025;
originally announced April 2025.
-
Dynamics of Magnetic Evaporative Beamline Cooling for Preparation of Cold Atomic Beams
Authors:
A. Ashtari Esfahani,
S. Bhagvati,
S. Böser,
M. J. Brandsema,
R. Cabral,
V. A. Chirayath,
C. Claessens,
N. Coward,
L. de Viveiros,
P. J. Doe,
M. G. Elliott,
S. Enomoto,
M. Fertl,
J. A. Formaggio,
B. T. Foust,
J. K. Gaison,
P. Harmston,
K. M. Heeger,
B. J. P. Jones,
E. Karim,
K. Kazkaz,
P. T. Kolbeck,
M. Li,
A. Lindman,
C. Y. Liu
, et al. (33 additional authors not shown)
Abstract:
The most sensitive direct neutrino mass searches today are based on measurement of the endpoint of the beta spectrum of tritium to infer limits on the mass of the unobserved recoiling neutrino. To avoid the smearing associated with the distribution of molecular final states in the T-He molecule, the next generation of these experiments will need to employ atomic (T) rather than molecular (T$_{2}$)…
▽ More
The most sensitive direct neutrino mass searches today are based on measurement of the endpoint of the beta spectrum of tritium to infer limits on the mass of the unobserved recoiling neutrino. To avoid the smearing associated with the distribution of molecular final states in the T-He molecule, the next generation of these experiments will need to employ atomic (T) rather than molecular (T$_{2}$) tritium sources. Following production, atomic T can be trapped in gravitational and / or magnetic bottles for beta spectrum experiments, if and only if it can first be cooled to millikelvin temperatures. Accomplishing this cooling presents substantial technological challenges. The Project 8 collaboration is developing a technique based on magnetic evaporative cooling along a beamline (MECB) for the purpose of cooling T to feed a magneto-gravitational trap that also serves as a cyclotron radiation emission spectroscope. Initial tests of the approach are planned in a pathfinder apparatus using atomic Li. This paper presents a method for analyzing the dynamics of the MECB technique, and applies these calculations to the design of systems for cooling and slowing of atomic Li and T. A scheme is outlined that could provide a current of T at the millikelvin temperatures required for the Project 8 neutrino mass search.
△ Less
Submitted 31 January, 2025;
originally announced February 2025.
-
Deep Learning Based Event Reconstruction for Cyclotron Radiation Emission Spectroscopy
Authors:
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
R. Cervantes,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
J. K. Gaison,
L. Gladstone,
M. Grando,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
K. Kazkaz,
M. Li,
A. Lindman,
A. Marsteller,
C. Matthé,
R. Mohiuddin,
B. Monreal,
E. C. Morrison
, et al. (26 additional authors not shown)
Abstract:
The objective of the Cyclotron Radiation Emission Spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time-frequency plane. Due to the need for excellent instrumental energy resolution in…
▽ More
The objective of the Cyclotron Radiation Emission Spectroscopy (CRES) technology is to build precise particle energy spectra. This is achieved by identifying the start frequencies of charged particle trajectories which, when exposed to an external magnetic field, leave semi-linear profiles (called tracks) in the time-frequency plane. Due to the need for excellent instrumental energy resolution in application, highly efficient and accurate track reconstruction methods are desired. Deep learning convolutional neural networks (CNNs) - particularly suited to deal with information-sparse data and which offer precise foreground localization - may be utilized to extract track properties from measured CRES signals (called events) with relative computational ease. In this work, we develop a novel machine learning based model which operates a CNN and a support vector machine in tandem to perform this reconstruction. A primary application of our method is shown on simulated CRES signals which mimic those of the Project 8 experiment - a novel effort to extract the unknown absolute neutrino mass value from a precise measurement of tritium $β^-$-decay energy spectrum. When compared to a point-clustering based technique used as a baseline, we show a relative gain of 24.1% in event reconstruction efficiency and comparable performance in accuracy of track parameter reconstruction.
△ Less
Submitted 5 January, 2024;
originally announced February 2024.
-
Real-time Signal Detection for Cyclotron Radiation Emission Spectroscopy Measurements using Antenna Arrays
Authors:
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
B. T. Foust,
J. K. Gaison,
M. Grando,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
B. J. P. Jones,
K. Kazkaz,
B. H. LaRoque,
M. Li,
A. Lindman,
A. Marsteller,
C. Matthé,
R. Mohiuddin,
B. Monreal,
B. Mucogllava
, et al. (26 additional authors not shown)
Abstract:
Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40~meV, requiring a large supply of tritium atoms store…
▽ More
Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for precision measurement of the energies of charged particles, which is being developed by the Project 8 Collaboration to measure the neutrino mass using tritium beta-decay spectroscopy. Project 8 seeks to use the CRES technique to measure the neutrino mass with a sensitivity of 40~meV, requiring a large supply of tritium atoms stored in a multi-cubic meter detector volume. Antenna arrays are one potential technology compatible with an experiment of this scale, but the capability of an antenna-based CRES experiment to measure the neutrino mass depends on the efficiency of the signal detection algorithms. In this paper, we develop efficiency models for three signal detection algorithms and compare them using simulations from a prototype antenna-based CRES experiment as a case-study. The algorithms include a power threshold, a matched filter template bank, and a neural network based machine learning approach, which are analyzed in terms of their average detection efficiency and relative computational cost. It is found that significant improvements in detection efficiency and, therefore, neutrino mass sensitivity are achievable, with only a moderate increase in computation cost, by utilizing either the matched filter or machine learning approach in place of a power threshold, which is the baseline signal detection algorithm used in previous CRES experiments by Project 8.
△ Less
Submitted 3 October, 2023;
originally announced October 2023.
-
Cyclotron Radiation Emission Spectroscopy of Electrons from Tritium Beta Decay and $^{83\rm m}$Kr Internal Conversion
Authors:
Project 8 Collaboration,
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
C. Claessens,
L. de Viveiros,
P. J. Doe,
M. Fertl,
J. A. Formaggio,
J. K. Gaison,
L. Gladstone,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
M. Li,
A. Lindman,
E. Machado,
A. Marsteller,
C. Matthé,
R. Mohiuddin
, et al. (32 additional authors not shown)
Abstract:
Project 8 has developed a novel technique, Cyclotron Radiation Emission Spectroscopy (CRES), for direct neutrino mass measurements. A CRES-based experiment on the beta spectrum of tritium has been carried out in a small-volume apparatus. We provide a detailed account of the experiment, focusing on systematic effects and analysis techniques. In a Bayesian (frequentist) analysis, we measure the trit…
▽ More
Project 8 has developed a novel technique, Cyclotron Radiation Emission Spectroscopy (CRES), for direct neutrino mass measurements. A CRES-based experiment on the beta spectrum of tritium has been carried out in a small-volume apparatus. We provide a detailed account of the experiment, focusing on systematic effects and analysis techniques. In a Bayesian (frequentist) analysis, we measure the tritium endpoint as $18553^{+18}_{-19}$ ($18548^{+19}_{-19}$) eV and set upper limits of 155 (152) eV (90% C.L.) on the neutrino mass. No background events are observed beyond the endpoint in 82 days of running. We also demonstrate an energy resolution of $1.66\pm0.19$ eV in a resolution-optimized magnetic trap configuration by measuring $^{83\rm m}$Kr 17.8-keV internal-conversion electrons. These measurements establish CRES as a low-background, high-resolution technique with the potential to advance neutrino mass sensitivity.
△ Less
Submitted 23 December, 2023; v1 submitted 21 March, 2023;
originally announced March 2023.
-
SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration
Authors:
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Grando,
J. Hartse,
K. M. Heeger,
X. Huyan,
A. M. Jones,
K. Kazkaz,
M. Li,
A. Lindman,
C. Matthé,
R. Mohiuddin,
B. Monreal,
R. Mueller,
J. A. Nikkel,
E. Novitski,
N. S. Oblath,
J. I. Peña
, et al. (20 additional authors not shown)
Abstract:
Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenn…
▽ More
Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting $β$-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. We find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.
△ Less
Submitted 15 December, 2022;
originally announced December 2022.
-
Tritium Beta Spectrum and Neutrino Mass Limit from Cyclotron Radiation Emission Spectroscopy
Authors:
Project 8 Collaboration,
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
C. Claessens,
L. de Viveiros,
P. J. Doe,
M. Fertl,
J. A. Formaggio,
J. K. Gaison,
L. Gladstone,
M. Grando,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
M. Li,
A. Lindman,
E. Machado,
A. Marsteller
, et al. (34 additional authors not shown)
Abstract:
The absolute scale of the neutrino mass plays a critical role in physics at every scale, from the particle to the cosmological. Measurements of the tritium endpoint spectrum have provided the most precise direct limit on the neutrino mass scale. In this Letter, we present advances by Project 8 to the Cyclotron Radiation Emission Spectroscopy (CRES) technique culminating in the first frequency-base…
▽ More
The absolute scale of the neutrino mass plays a critical role in physics at every scale, from the particle to the cosmological. Measurements of the tritium endpoint spectrum have provided the most precise direct limit on the neutrino mass scale. In this Letter, we present advances by Project 8 to the Cyclotron Radiation Emission Spectroscopy (CRES) technique culminating in the first frequency-based neutrino mass limit. With only a cm$^3$-scale physical detection volume, a limit of $m_β{<}$155 eV ($152$ eV) is extracted from the background-free measurement of the continuous tritium beta spectrum in a Bayesian (frequentist) analysis. Using $^{83{\rm m}}$Kr calibration data, an improved resolution of 1.66${\pm}$0.19 eV (FWHM) is measured, the detector response model is validated, and the efficiency is characterized over the multi-keV tritium analysis window. These measurements establish the potential of CRES for a high-sensitivity next-generation direct neutrino mass experiment featuring low background and high resolution.
△ Less
Submitted 17 March, 2023; v1 submitted 9 December, 2022;
originally announced December 2022.
-
The Project 8 Neutrino Mass Experiment
Authors:
Project 8 Collaboration,
A. Ashtari Esfahani,
S. Böser,
N. Buzinsky,
M. C. Carmona-Benitez,
C. Claessens,
L. de Viveiros,
P. J. Doe,
S. Enomoto,
M. Fertl,
J. A. Formaggio,
J. K. Gaison,
M. Grando,
K. M. Heeger,
X. Huyan,
A. M. Jones,
K. Kazkaz,
M. Li,
A. Lindman,
C. Matthé,
R. Mohiuddin,
B. Monreal,
R. Mueller,
J. A. Nikkel,
E. Novitski
, et al. (23 additional authors not shown)
Abstract:
Measurements of the $β^-$ spectrum of tritium give the most precise direct limits on neutrino mass. Project 8 will investigate neutrino mass using Cyclotron Radiation Emission Spectroscopy (CRES) with an atomic tritium source. CRES is a new experimental technique that has the potential to surmount the systematic and statistical limitations of current-generation direct measurement methods. Atomic t…
▽ More
Measurements of the $β^-$ spectrum of tritium give the most precise direct limits on neutrino mass. Project 8 will investigate neutrino mass using Cyclotron Radiation Emission Spectroscopy (CRES) with an atomic tritium source. CRES is a new experimental technique that has the potential to surmount the systematic and statistical limitations of current-generation direct measurement methods. Atomic tritium avoids an irreducible systematic uncertainty associated with the final states populated by the decay of molecular tritium. Project 8 will proceed in a phased approach toward a goal of 40 meV/c$^2$ neutrino-mass sensitivity.
△ Less
Submitted 14 March, 2022;
originally announced March 2022.
-
Measurement of the $^{239}$Pu(n,f)/$^{235}$U(n,f) Cross-Section Ratio with the NIFFTE fission Time Projection Chamber
Authors:
L. Snyder,
M. Anastasiou,
N. S. Bowden,
J. Bundgaard,
R. J. Casperson,
D. A. Cebra,
T. Classen,
D. H. Dongwi,
N. Fotiades,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
C. Hagmann,
M. Heffner,
D. Hensle,
D. Higgins,
L. D. Isenhower,
K. Kazkaz,
A. Kemnitz,
J. King,
J. L. Klay,
J. Latta,
E. Leal-Cidoncha,
W. Loveland,
J. A. Magee
, et al. (15 additional authors not shown)
Abstract:
The $^{239}$Pu(n,f)/$^{235}$U(n,f) cross-section ratio has been measured with the fission Time Projection Chamber (fissionTPC) from 100 keV to 100 MeV. The fissionTPC provides three-dimensional reconstruction of fission-fragment ionization profiles, allowing for a precise quantification of measurement uncertainties. The measurement was performed at the Los Alamos Neutron Science Center which provi…
▽ More
The $^{239}$Pu(n,f)/$^{235}$U(n,f) cross-section ratio has been measured with the fission Time Projection Chamber (fissionTPC) from 100 keV to 100 MeV. The fissionTPC provides three-dimensional reconstruction of fission-fragment ionization profiles, allowing for a precise quantification of measurement uncertainties. The measurement was performed at the Los Alamos Neutron Science Center which provides a pulsed white source of neutrons. The data are recommended to be used as a cross-section ratio shape. A discussion of the status of the absolute normalization and comparisons to ENDF evaluations and previous measurements is included.
△ Less
Submitted 6 July, 2021;
originally announced July 2021.
-
Measurement of material isotopics and atom number ratio with alpha-particle spectroscopy for the NIFFTE fission Time Projection Chamber actinide target
Authors:
M. Monterial,
K. T. Schmitt,
C. Prokop,
E. Leal-Cidoncha,
M. Anastasiou,
N. S. Bowden,
J. Bundgaard,
R. J. Casperson,
D. A. Cebra,
T. Classen,
D. H. Dongwi,
N. Fotiades,
J. Gearhart,
V. Geppert-Kleinrath,
U. Greife,
C. Hagmann,
M. Heffner,
D. Hensle,
D. Higgins,
L. D. Isenhower,
K. Kazkaz,
A. Kemnitz,
J. King,
J. L. Klay,
J. Latta
, et al. (15 additional authors not shown)
Abstract:
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio betwee…
▽ More
We present the results of a measurement of isotopic concentrations and atomic number ratio of a double-sided actinide target with alpha-spectroscopy and mass spectrometry. The double-sided actinide target, with primarily Pu-239 on one side and U-235 on the other, was used in the fission Time Projection Chamber (fissionTPC) for a measurement of the neutron-induced fission cross-section ratio between the two isotopes. The measured atomic number ratio is intended to provide an absolute normalization of the measured fission cross-section ratio. The Pu-239/U-235 atom number ratio was measured with a combination of mass spectrometry and alpha-spectroscopy with a planar silicon detector with uncertainties of less than 1%.
△ Less
Submitted 9 July, 2021; v1 submitted 10 June, 2021;
originally announced June 2021.
-
Projected sensitivity of the LUX-ZEPLIN (LZ) experiment to the two-neutrino and neutrinoless double beta decays of $^{134}$Xe
Authors:
The LUX-ZEPLIN,
Collaboration,
:,
D. S. Akerib,
A. K. Al Musalhi,
S. K. Alsum,
C. S. Amarasinghe,
A. Ames,
T. J. Anderson,
N. Angelides,
H. M. Araujo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
J. W. Bargemann,
D. Bauer,
A. Baxter,
P. Beltrame,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert
, et al. (172 additional authors not shown)
Abstract:
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity t…
▽ More
The projected sensitivity of the LUX-ZEPLIN (LZ) experiment to two-neutrino and neutrinoless double beta decay of $^{134}$Xe is presented. LZ is a 10-tonne xenon time projection chamber optimized for the detection of dark matter particles, that is expected to start operating in 2021 at Sanford Underground Research Facility, USA. Its large mass of natural xenon provides an exceptional opportunity to search for the double beta decay of $^{134}$Xe, for which xenon detectors enriched in $^{136}$Xe are less effective. For the two-neutrino decay mode, LZ is predicted to exclude values of the half-life up to 1.7$\times$10$^{24}$ years at 90% confidence level (CL), and has a three-sigma observation potential of 8.7$\times$10$^{23}$ years, approaching the predictions of nuclear models. For the neutrinoless decay mode LZ, is projected to exclude values of the half-life up to 7.3$\times$10$^{24}$ years at 90% CL.
△ Less
Submitted 22 November, 2021; v1 submitted 26 April, 2021;
originally announced April 2021.
-
Bayesian Analysis of a Future Beta Decay Experiment's Sensitivity to Neutrino Mass Scale and Ordering
Authors:
A. Ashtari Esfahani,
M. Betancourt,
Z. Bogorad,
S. Böser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Grando,
M. Guigue,
J. Hartse,
K. M. Heeger,
X. Huyan,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
A. Lindman,
R. Mohiuddin,
B. Monreal,
J. A. Nikkel,
E. Novitski
, et al. (21 additional authors not shown)
Abstract:
Bayesian modeling techniques enable sensitivity analyses that incorporate detailed expectations regarding future experiments. A model-based approach also allows one to evaluate inferences and predicted outcomes, by calibrating (or measuring) the consequences incurred when certain results are reported. We present procedures for calibrating predictions of an experiment's sensitivity to both continuo…
▽ More
Bayesian modeling techniques enable sensitivity analyses that incorporate detailed expectations regarding future experiments. A model-based approach also allows one to evaluate inferences and predicted outcomes, by calibrating (or measuring) the consequences incurred when certain results are reported. We present procedures for calibrating predictions of an experiment's sensitivity to both continuous and discrete parameters. Using these procedures and a new Bayesian model of the $β$-decay spectrum, we assess a high-precision $β$-decay experiment's sensitivity to the neutrino mass scale and ordering, for one assumed design scenario. We find that such an experiment could measure the electron-weighted neutrino mass within $\sim40\,$meV after 1 year (90$\%$ credibility). Neutrino masses $>500\,$meV could be measured within $\approx5\,$meV. Using only $β$-decay and external reactor neutrino data, we find that next-generation $β$-decay experiments could potentially constrain the mass ordering using a two-neutrino spectral model analysis. By calibrating mass ordering results, we identify reporting criteria that can be tuned to suppress false ordering claims. In some cases, a two-neutrino analysis can reveal that the mass ordering is inverted, an unobtainable result for the traditional one-neutrino analysis approach.
△ Less
Submitted 1 June, 2021; v1 submitted 24 December, 2020;
originally announced December 2020.
-
Discrimination of electronic recoils from nuclear recoils in two-phase xenon time projection chambers
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese
, et al. (72 additional authors not shown)
Abstract:
We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclea…
▽ More
We present a comprehensive analysis of electronic recoil vs. nuclear recoil discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014-16 runs of the Large Underground Xenon (LUX) experiment. We observe strong charge-to-light discrimination enhancement with increased event energy. For events with S1 = 120 detected photons, i.e. equivalent to a nuclear recoil energy of $\sim$100 keV, we observe an electronic recoil background acceptance of $<10^{-5}$ at a nuclear recoil signal acceptance of 50%. We also observe modest electric field dependence of the discrimination power, which peaks at a field of around 300 V/cm over the range of fields explored in this study (50-500 V/cm). In the WIMP search region of S1 = 1-80 phd, the minimum electronic recoil leakage we observe is ${(7.3\pm0.6)\times10^{-4}}$, which is obtained for a drift field of 240-290 V/cm. Pulse shape discrimination is utilized to improve our results, and we find that, at low energies and low fields, there is an additional reduction in background leakage by a factor of up to 3. We develop an empirical model for recombination fluctuations which, when used alongside the Noble Element Scintillation Technique (NEST) simulation package, correctly reproduces the skewness of the electronic recoil data. We use this updated simulation to study the width of the electronic recoil band, finding that its dominant contribution comes from electron-ion recombination fluctuations, followed in magnitude of contribution by fluctuations in the S1 signal, fluctuations in the S2 signal, and fluctuations in the total number of quanta produced for a given energy deposition.
△ Less
Submitted 9 December, 2020; v1 submitted 14 April, 2020;
originally announced April 2020.
-
Neutron Induced Fission Fragment Angular Distributions, Anisotropy, and Linear Momentum Transfer Measured with the NIFFTE Fission Time Projection Chamber
Authors:
D. Hensle,
J. T. Barker,
J. S. Barrett,
N. S. Bowden,
K. J. Brewster,
J. Bundgaard,
Z. Q. Case,
R. J. Casperson,
D. A. Cebra,
T. Classen,
D. L. Duke,
N. Fotiadis,
J Gearhart,
V. Geppert-Kleinrath,
U. Greife,
E. Guardincerri,
C. Hagmann,
M. Heffner,
C. R. Hicks,
D. Higgins,
L. D. Isenhower,
K. Kazkaz,
A. Kemnitz,
K. J. Kiesling,
J. King
, et al. (24 additional authors not shown)
Abstract:
The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has performed measurements with a fission time projection chamber (fissionTPC) to study the fission process by reconstructing full three-dimensional tracks of fission fragments and other ionizing radiation. The amount of linear momentum imparted to the fissioning nucleus by the incident neutron can be inferred by measu…
▽ More
The Neutron Induced Fission Fragment Tracking Experiment (NIFFTE) collaboration has performed measurements with a fission time projection chamber (fissionTPC) to study the fission process by reconstructing full three-dimensional tracks of fission fragments and other ionizing radiation. The amount of linear momentum imparted to the fissioning nucleus by the incident neutron can be inferred by measuring the opening angle between the fission fragments. Using this measured linear momentum, fission fragment angular distributions can be converted to the center-of-mass frame for anisotropy measurements. Angular anisotropy is an important experimental observable for understanding the quantum mechanical state of the fissioning nucleus and vital to determining detection efficiency for cross section measurements. Neutron linear momentum transfer to fissioning $^{235}$U, $^{238}$U, and $^{239}$Pu and fission fragment angular anisotropy of $^{235}$U and $^{238}$U as a function of neutron energies in the range 130 keV--250 MeV are presented.
△ Less
Submitted 25 January, 2020;
originally announced January 2020.
-
Projected sensitivity of the LUX-ZEPLIN experiment to the $0νββ$ decay of $^{136}$Xe
Authors:
D. S. Akerib,
C. W. Akerlof,
A. Alqahtani,
S. K. Alsum,
T. J. Anderson,
N. Angelides,
H. M. Araújo,
J. E. Armstrong,
M. Arthurs,
X. Bai,
J. Balajthy,
S. Balashov,
J. Bang,
A. Baxter,
J. Bensinger,
E. P. Bernard,
A. Bernstein,
A. Bhatti,
A. Biekert,
T. P. Biesiadzinski,
H. J. Birch,
K. E. Boast,
B. Boxer,
P. Brás,
J. H. Buckley
, et al. (167 additional authors not shown)
Abstract:
The LUX-ZEPLIN (LZ) experiment will enable a neutrinoless double beta decay search in parallel to the main science goal of discovering dark matter particle interactions. We report the expected LZ sensitivity to $^{136}$Xe neutrinoless double beta decay, taking advantage of the significant ($>$600 kg) $^{136}$Xe mass contained within the active volume of LZ without isotopic enrichment. After 1000 l…
▽ More
The LUX-ZEPLIN (LZ) experiment will enable a neutrinoless double beta decay search in parallel to the main science goal of discovering dark matter particle interactions. We report the expected LZ sensitivity to $^{136}$Xe neutrinoless double beta decay, taking advantage of the significant ($>$600 kg) $^{136}$Xe mass contained within the active volume of LZ without isotopic enrichment. After 1000 live-days, the median exclusion sensitivity to the half-life of $^{136}$Xe is projected to be 1.06$\times$10$^{26}$ years (90% confidence level), similar to existing constraints. We also report the expected sensitivity of a possible subsequent dedicated exposure using 90% enrichment with $^{136}$Xe at 1.06$\times$10$^{27}$ years.
△ Less
Submitted 24 April, 2020; v1 submitted 9 December, 2019;
originally announced December 2019.
-
Search for two neutrino double electron capture of $^{124}$Xe and $^{126}$Xe in the full exposure of the LUX detector
Authors:
LUX Collaboration,
D. S. Akerib,
S. Alsum,
H. M. Araújo,
X. Bai,
J. Balajthy,
A. Baxter,
E. P. Bernard,
A. Bernstein,
T. P. Biesiadzinski,
E. M. Boulton,
B. Boxer,
P. Brás,
S. Burdin,
D. Byram,
M. C. Carmona-Benitez,
C. Chan,
J. E. Cutter,
L. de Viveiros,
E. Druszkiewicz,
A. Fan,
S. Fiorucci,
R. J. Gaitskell,
C. Ghag,
M. G. D. Gilchriese
, et al. (74 additional authors not shown)
Abstract:
Two-neutrino double electron capture is a process allowed in the Standard Model of Particle Physics. This rare decay has been observed in $^{78}$Kr, $^{130}$Ba and more recently in $^{124}$Xe. In this publication we report on the search for this process in $^{124}$Xe and $^{126}$Xe using the full exposure of the Large Underground Xenon (LUX) experiment, in a total of of 27769.5~kg-days. No evidenc…
▽ More
Two-neutrino double electron capture is a process allowed in the Standard Model of Particle Physics. This rare decay has been observed in $^{78}$Kr, $^{130}$Ba and more recently in $^{124}$Xe. In this publication we report on the search for this process in $^{124}$Xe and $^{126}$Xe using the full exposure of the Large Underground Xenon (LUX) experiment, in a total of of 27769.5~kg-days. No evidence of a signal was observed, allowing us to set 90\% C.L. lower limits for the half-lives of these decays of $2.0\times10^{21}$~years for $^{124}$Xe and $1.9\times10^{21}$~years for $^{126}$Xe.
△ Less
Submitted 19 May, 2020; v1 submitted 5 December, 2019;
originally announced December 2019.
-
Cyclotron Radiation Emission Spectroscopy Signal Classification with Machine Learning in Project 8
Authors:
A. Ashtari Esfahani,
S. Boser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Guigue,
K. M. Heeger,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
A. Lindman,
E. Machado,
B. Monreal,
E. C. Morrison,
J. A. Nikkel,
E. Novitski,
N. S. Oblath,
W. Pettus,
R. G. H. Robertson,
G. Rybka
, et al. (10 additional authors not shown)
Abstract:
The Cyclotron Radiation Emission Spectroscopy (CRES) technique pioneered by Project 8 measures electromagnetic radiation from individual electrons gyrating in a background magnetic field to construct a highly precise energy spectrum for beta decay studies and other applications. The detector, magnetic trap geometry, and electron dynamics give rise to a multitude of complex electron signal structur…
▽ More
The Cyclotron Radiation Emission Spectroscopy (CRES) technique pioneered by Project 8 measures electromagnetic radiation from individual electrons gyrating in a background magnetic field to construct a highly precise energy spectrum for beta decay studies and other applications. The detector, magnetic trap geometry, and electron dynamics give rise to a multitude of complex electron signal structures which carry information about distinguishing physical traits. With machine learning models, we develop a scheme based on these traits to analyze and classify CRES signals. Understanding and proper use of these traits will be instrumental to improve cyclotron frequency reconstruction and help Project 8 achieve world-leading sensitivity on the tritium endpoint measurement in the future.
△ Less
Submitted 3 March, 2020; v1 submitted 17 September, 2019;
originally announced September 2019.
-
Electron Radiated Power in Cyclotron Radiation Emission Spectroscopy Experiments
Authors:
A. Ashtari Esfahani,
V. Bansal,
S. Boser,
N. Buzinsky,
R. Cervantes,
C. Claessens,
L. de Viveiros,
P. J. Doe,
M. Fertl,
J. A. Formaggio,
L. Gladstone,
M. Guigue,
K. M. Heeger,
J. Johnston,
A. M. Jones,
K. Kazkaz,
B. H. LaRoque,
M. Leber,
A. Lindman,
E. Machado,
B. Monreal,
E. C. Morrison,
J. A. Nikkel,
E. Novitski,
N. S. Oblath
, et al. (16 additional authors not shown)
Abstract:
The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about…
▽ More
The recently developed technique of Cyclotron Radiation Emission Spectroscopy (CRES) uses frequency information from the cyclotron motion of an electron in a magnetic bottle to infer its kinetic energy. Here we derive the expected radio frequency signal from an electron in a waveguide CRES apparatus from first principles. We demonstrate that the frequency-domain signal is rich in information about the electron's kinematic parameters, and extract a set of measurables that in a suitably designed system are sufficient for disentangling the electron's kinetic energy from the rest of its kinematic features. This lays the groundwork for high-resolution energy measurements in future CRES experiments, such as the Project 8 neutrino mass measurement.
△ Less
Submitted 9 January, 2019;
originally announced January 2019.
-
Project 8 detector upgrades for a tritium beta decay spectrum using cyclotron radiation
Authors:
A Ashtari Esfahani,
S Böser,
C Claessens,
L de Viveiros,
P J Doe,
S Doeleman,
M Fertl,
E C Finn,
J A Formaggio,
M Guigue,
K M Heeger,
A M Jones,
K Kazkaz,
B H LaRoque,
E Machado,
B Monreal,
J A Nikkel,
N S Oblath,
R G H Robertson,
L J Rosenberg,
G Rybka,
L Saldaña,
P L Slocum,
J R Tedeschi,
T Thümmler
, et al. (5 additional authors not shown)
Abstract:
Following the successful observation of single conversion electrons from $^{83m}$Kr using Cyclotron Radiation Emission Spectroscopy (CRES), Project 8 is now advancing its focus toward a tritium beta decay spectrum. A tritium spectrum will be an important next step toward a direct measurement of the neutrino mass for Project 8. Here we discuss recent progress on the development and commissioning of…
▽ More
Following the successful observation of single conversion electrons from $^{83m}$Kr using Cyclotron Radiation Emission Spectroscopy (CRES), Project 8 is now advancing its focus toward a tritium beta decay spectrum. A tritium spectrum will be an important next step toward a direct measurement of the neutrino mass for Project 8. Here we discuss recent progress on the development and commissioning of a new gas cell for use with tritium, and outline the primary goals of the experiment for the near future.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
Results from the Project 8 phase-1 cyclotron radiation emission spectroscopy detector
Authors:
A Ashtari Esfahani,
S Böser,
C Claessens,
L de Viveiros,
P J Doe,
S Doeleman,
M Fertl,
E C Finn,
J A Formaggio,
M Guigue,
K M Heeger,
A M Jones,
K Kazkaz,
B H LaRoque,
E Machado,
B Monreal,
J A Nikkel,
N S Oblath,
R G H Robertson,
L J Rosenberg,
G Rybka,
L Saldaña,
P L Slocum,
J R Tedeschi,
T Thümmler
, et al. (5 additional authors not shown)
Abstract:
The Project 8 collaboration seeks to measure the absolute neutrino mass scale by means of precision spectroscopy of the beta decay of tritium. Our technique, cyclotron radiation emission spectroscopy, measures the frequency of the radiation emitted by electrons produced by decays in an ambient magnetic field. Because the cyclotron frequency is inversely proportional to the electron's Lorentz facto…
▽ More
The Project 8 collaboration seeks to measure the absolute neutrino mass scale by means of precision spectroscopy of the beta decay of tritium. Our technique, cyclotron radiation emission spectroscopy, measures the frequency of the radiation emitted by electrons produced by decays in an ambient magnetic field. Because the cyclotron frequency is inversely proportional to the electron's Lorentz factor, this is also a measurement of the electron's energy. In order to demonstrate the viability of this technique, we have assembled and successfully operated a prototype system, which uses a rectangular waveguide to collect the cyclotron radiation from internal conversion electrons emitted from a gaseous $^{83m}$Kr source. Here we present the main design aspects of the first phase prototype, which was operated during parts of 2014 and 2015. We will also discuss the procedures used to analyze these data, along with the features which have been observed and the performance achieved to date.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
Project 8 Phase III Design Concept
Authors:
A Ashtari Esfahani,
S Böser,
C Claessens,
L de Viveiros,
P J Doe,
S Doeleman,
M Fertl,
E C Finn,
J A Formaggio,
M Guigue,
K M Heeger,
A M Jones,
K Kazkaz,
B H LaRoque,
E Machado,
B Monreal,
J A Nikkel,
N S Oblath,
R G H Robertson,
L J Rosenberg,
G Rybka,
L Saldaña,
P L Slocum,
J R Tedeschi,
T Thümmler
, et al. (5 additional authors not shown)
Abstract:
We present a working concept for Phase III of the Project 8 experiment, aiming to achieve a neutrino mass sensitivity of $2~\mathrm{eV}$ ($90~\%$ C.L.) using a large volume of molecular tritium and a phased antenna array. The detection system is discussed in detail.
We present a working concept for Phase III of the Project 8 experiment, aiming to achieve a neutrino mass sensitivity of $2~\mathrm{eV}$ ($90~\%$ C.L.) using a large volume of molecular tritium and a phased antenna array. The detection system is discussed in detail.
△ Less
Submitted 15 March, 2017;
originally announced March 2017.
-
Determining the neutrino mass with Cyclotron Radiation Emission Spectroscopy - Project 8
Authors:
Ali Ashtari Esfahani,
David M. Asner,
Sebastian Böser,
Raphael Cervantes,
Christine Claessens,
Luiz de Viveiros,
Peter J. Doe,
Shepard Doeleman,
Justin L. Fernandes,
Martin Fertl,
Erin C. Finn,
Joseph A. Formaggio,
Daniel Furse,
Mathieu Guigue,
Karsten M. Heeger,
A. Mark Jones,
Kareem Kazkaz,
Jared A. Kofron,
Callum Lamb,
Benjamin H. LaRoque,
Eric Machado,
Elizabeth L. McBride,
Michael L. Miller,
Benjamin Monreal,
Prajwal Mohanmurthy
, et al. (19 additional authors not shown)
Abstract:
The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with $\mathcal{O}({\rm eV})$ resolution. A lower bound of $m(ν_e) \gtrsim 9(0.1)\, {\rm meV}$ is set by observati…
▽ More
The most sensitive direct method to establish the absolute neutrino mass is observation of the endpoint of the tritium beta-decay spectrum. Cyclotron Radiation Emission Spectroscopy (CRES) is a precision spectrographic technique that can probe much of the unexplored neutrino mass range with $\mathcal{O}({\rm eV})$ resolution. A lower bound of $m(ν_e) \gtrsim 9(0.1)\, {\rm meV}$ is set by observations of neutrino oscillations, while the KATRIN Experiment - the current-generation tritium beta-decay experiment that is based on Magnetic Adiabatic Collimation with an Electrostatic (MAC-E) filter - will achieve a sensitivity of $m(ν_e) \lesssim 0.2\,{\rm eV}$. The CRES technique aims to avoid the difficulties in scaling up a MAC-E filter-based experiment to achieve a lower mass sensitivity. In this paper we review the current status of the CRES technique and describe Project 8, a phased absolute neutrino mass experiment that has the potential to reach sensitivities down to $m(ν_e) \lesssim 40\,{\rm meV}$ using an atomic tritium source.
△ Less
Submitted 6 March, 2017;
originally announced March 2017.
-
Fabrication and characterization of a lithium-glass-based composite neutron detector
Authors:
G. C. Rich,
K. Kazkaz,
H. P. Martinez,
T. Gushue
Abstract:
A novel composite, scintillating material intended for neutron detection and composed of small (1.5 mm) cubes of KG2-type lithium glass embedded in a matrix of scintillating plastic has been developed in the form of a 2.2 in.-diameter, 3.1 in.-tall cylindrical prototype loaded with $\left( 5.82 \pm 0.02 \right)\%$ lithium glass by mass. The response of the material when exposed to ${}^{252}$Cf fis…
▽ More
A novel composite, scintillating material intended for neutron detection and composed of small (1.5 mm) cubes of KG2-type lithium glass embedded in a matrix of scintillating plastic has been developed in the form of a 2.2 in.-diameter, 3.1 in.-tall cylindrical prototype loaded with $\left( 5.82 \pm 0.02 \right)\%$ lithium glass by mass. The response of the material when exposed to ${}^{252}$Cf fission neutrons and various $γ$-ray sources has been studied; using the charge-integration method for pulse shape discrimination, good separation between neutron and $γ$-ray events is observed and intrinsic efficiencies of $\left( 1.15 \pm 0.16 \right)\times 10^{-2}$ and $\left( 2.28 \pm 0.21 \right)\times 10^{-4}$ for ${}^{252}$Cf fission neutrons and ${}^{60}$Co $γ$ rays are obtained; an upper limit for the sensitivity to ${}^{137}$Cs $γ$ rays is determined to be $< 3.70 \times 10^{-8}$. The neutron/$γ$ discrimination capabilities are improved in circumstances when a neutron capture signal in the lithium glass can be detected in coincidence with a preceding elastic scattering event in the plastic scintillator; with this coincidence requirement, the intrinsic efficiency of the prototype detector for ${}^{60}$Co $γ$ rays is $\left( 2.42 \pm 0.61 \right)\times 10^{-6}$ while its intrinsic efficiency for unmoderated ${}^{252}$Cf fission neutrons is $\left( 4.31 \pm 0.59 \right)\times 10^{-3}$. Through use of subregion-integration ratios in addition to the coincidence requirement, the efficiency for $γ$ rays from ${}^{60}$Co is reduced to $\left( 7.15 \pm 4.10 \right) \times 10^{-7}$ while the ${}^{252}$Cf fission neutron efficiency becomes $\left( 2.78 \pm 0.38 \right) \times 10^{-3}$.
△ Less
Submitted 25 May, 2015; v1 submitted 9 October, 2014;
originally announced October 2014.
-
CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy
Authors:
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
S. Copello
, et al. (95 additional authors not shown)
Abstract:
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrino…
▽ More
The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrinoless double beta decay half-life sensitivity is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). Further background rejection with auxiliary light detector can significantly improve the search sensitivity and competitiveness of bolometric detectors to fully explore the inverted neutrino mass hierarchy with $^{130}$Te and possibly other double beta decay candidate nuclei.
△ Less
Submitted 3 July, 2014;
originally announced July 2014.
-
Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors
Authors:
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (94 additional authors not shown)
Abstract:
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simu…
▽ More
Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simulate several configurations of a future CUORE-like bolometer array which would utilize these improvements and present the sensitivity reach of a hypothetical next-generation bolometric 0nubb experiment. We demonstrate that a bolometric experiment with the isotope mass of about 1 ton is capable of reaching the sensitivity to the effective Majorana neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the so-called inverted neutrino mass hierarchy region. We highlight the main challenges and identify priorities for an R&D program addressing them.
△ Less
Submitted 17 April, 2014;
originally announced April 2014.
-
Searching for neutrinoless double-beta decay of $^{130}$Te with CUORE
Authors:
CUORE Collaboration,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
A. Camacho,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza
, et al. (96 additional authors not shown)
Abstract:
Neutrinoless double-beta ($0νββ$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0νββ$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detecto…
▽ More
Neutrinoless double-beta ($0νββ$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0νββ$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detector will contain 206 kg of $^{130}$Te and have an average energy resolution of 5 keV; the projected $0νββ$ decay half-life sensitivity after five years of live time is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). In this paper we review the experimental techniques used in CUORE as well as its current status and anticipated physics reach.
△ Less
Submitted 13 February, 2015; v1 submitted 25 February, 2014;
originally announced February 2014.
-
First measurement of the ionization yield of nuclear recoils in liquid argon
Authors:
T. H. Joshi,
S. Sangiorgio,
A. Bernstein,
M. Foxe,
C. Hagmann,
I. Jovanovic,
K. Kazkaz,
V. Mozin,
E. B. Norman,
S. V. Pereverzev,
F. Rebassoo,
P. Sorensen
Abstract:
This Letter details a measurement of the ionization yield ($Q_y$) of 6.7 keV $^{40}Ar$ atoms stopping in a liquid argon detector. The $Q_y$ of 3.6-6.3 detected $e^{-}/\mbox{keV}$, for applied electric fields in the range 240--2130 V/cm, is encouraging for the use of this detector medium to search for the signals from hypothetical dark matter particle interactions and from coherent elastic neutrino…
▽ More
This Letter details a measurement of the ionization yield ($Q_y$) of 6.7 keV $^{40}Ar$ atoms stopping in a liquid argon detector. The $Q_y$ of 3.6-6.3 detected $e^{-}/\mbox{keV}$, for applied electric fields in the range 240--2130 V/cm, is encouraging for the use of this detector medium to search for the signals from hypothetical dark matter particle interactions and from coherent elastic neutrino nucleus scattering. A significant dependence of $Q_y$ on the applied electric field is observed and explained in the context of ion recombination.
△ Less
Submitted 1 May, 2014; v1 submitted 10 February, 2014;
originally announced February 2014.
-
Initial performance of the CUORE-0 experiment
Authors:
CUORE Collaboration,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
X. G. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (88 additional authors not shown)
Abstract:
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-domina…
▽ More
CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-dominated region (2.70 to 3.90 MeV) have been measured to be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7 keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.
△ Less
Submitted 31 July, 2014; v1 submitted 4 February, 2014;
originally announced February 2014.
-
First demonstration of a sub-keV electron recoil energy threshold in a liquid argon ionization chamber
Authors:
S. Sangiorgio,
T. H. Joshi,
A. Bernstein,
J. Coleman,
M. Foxe,
C. Hagmann,
I. Jovanovic,
K. Kazkaz,
K. Mavrokoridis,
V. Mozin,
S. Pereverzev,
P. Sorensen
Abstract:
We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV a…
▽ More
We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV and 0.27 keV, following the K- and L-shell electron capture decay of Ar-37, respectively. The Ar-37 source preparation is described in detail, since it enables calibration that may also prove useful in dark matter direct detection experiments. An internally placed Fe-55 x-ray source simultaneously provided another calibration point at 5.9 keV. We discuss the ionization yield and electron recombination in liquid argon at those three calibration energies.
△ Less
Submitted 19 July, 2013; v1 submitted 17 January, 2013;
originally announced January 2013.
-
Validation of techniques to mitigate copper surface contamination in CUORE
Authors:
F. Alessandria,
R. Ardito,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
T. Bloxham,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (93 additional authors not shown)
Abstract:
In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniques explored to mitigate these backgrounds. Using data from a dedicated test apparatus constructed to validate and compare these techniques we demonstrate that copper surface contamination levels better than 10E-07 - 10E-…
▽ More
In this article we describe the background challenges for the CUORE experiment posed by surface contamination of inert detector materials such as copper, and present three techniques explored to mitigate these backgrounds. Using data from a dedicated test apparatus constructed to validate and compare these techniques we demonstrate that copper surface contamination levels better than 10E-07 - 10E-08 Bq/cm2 are achieved for 238U and 232Th. If these levels are reproduced in the final CUORE apparatus the projected 90% C.L. upper limit on the number of background counts in the region of interest is 0.02-0.03 counts/keV/kg/y depending on the adopted mitigation technique.
△ Less
Submitted 4 April, 2013; v1 submitted 3 October, 2012;
originally announced October 2012.
-
The low energy spectrum of TeO2 bolometers: results and dark matter perspectives for the CUORE-0 and CUORE experiments
Authors:
F. Alessandria,
R. Ardito,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
T. Bloxham,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
N. Chott,
M. Clemenza,
C. Cosmelli
, et al. (91 additional authors not shown)
Abstract:
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data…
▽ More
We collected 19.4 days of data from four 750 g TeO2 bolometers, and in three of them we were able to set the energy threshold around 3 keV using a new analysis technique. We found a background rate ranging from 25 cpd/keV/kg at 3 keV to 2 cpd/keV/kg at 25 keV, and a peak at 4.7 keV. The origin of this peak is presently unknown, but its presence is confirmed by a reanalysis of 62.7 kg.days of data from the finished CUORICINO experiment. Finally, we report the expected sensitivities of the CUORE0 (52 bolometers) and CUORE (988 bolometers) experiments to a WIMP annual modulation signal.
△ Less
Submitted 1 February, 2013; v1 submitted 12 September, 2012;
originally announced September 2012.
-
LUXSim: A Component-Centric Approach to Low-Background Simulations
Authors:
D. S. Akerib,
X. Bai,
S. Bedikian,
E. Bernard,
A. Bernstein,
A. Bradley,
S. B. Cahn,
M. C. Carmona-Benitez,
D. Carr,
J. J. Chapman,
K. Clark,
T. Classen,
T. Coffey,
S. Dazeley,
L. de Viveiros,
M. Dragowsky,
E. Druszkiewicz,
C. H. Faham,
S. Fiorucci,
R. J. Gaitskell,
K. R. Gibson,
C. Hall,
M. Hanhardt,
B. Holbrook,
M. Ihm
, et al. (38 additional authors not shown)
Abstract:
Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpo…
▽ More
Geant4 has been used throughout the nuclear and high-energy physics community to simulate energy depositions in various detectors and materials. These simulations have mostly been run with a source beam outside the detector. In the case of low-background physics, however, a primary concern is the effect on the detector from radioactivity inherent in the detector parts themselves. From this standpoint, there is no single source or beam, but rather a collection of sources with potentially complicated spatial extent. LUXSim is a simulation framework used by the LUX collaboration that takes a component-centric approach to event generation and recording. A new set of classes allows for multiple radioactive sources to be set within any number of components at run time, with the entire collection of sources handled within a single simulation run. Various levels of information can also be recorded from the individual components, with these record levels also being set at runtime. This flexibility in both source generation and information recording is possible without the need to recompile, reducing the complexity of code management and the proliferation of versions. Within the code itself, casting geometry objects within this new set of classes rather than as the default Geant4 classes automatically extends this flexibility to every individual component. No additional work is required on the part of the developer, reducing development time and increasing confidence in the results. We describe the guiding principles behind LUXSim, detail some of its unique classes and methods, and give examples of usage.
* Corresponding author, [email protected]
△ Less
Submitted 8 November, 2011;
originally announced November 2011.
-
Comparison of Lithium Gadolinium Borate Crystal Shards in Scintillating and Nonscintillating Plastic Matrices
Authors:
Kareem Kazkaz,
Nathaniel S. Bowden,
Marisa Pedretti
Abstract:
We present a method for detecting neutrons using scintillating lithium gadolinium borate crystal shards in a plastic matrix while maintaining high gamma rejection. We have procured two cylindrical detectors, 5"\times5", containing 1% crystal by mass. Crystal shards have a typical dimension of 1 mm. One detector was made with scintillating plastic, and one with nonscintillating plastic. Pulse shape…
▽ More
We present a method for detecting neutrons using scintillating lithium gadolinium borate crystal shards in a plastic matrix while maintaining high gamma rejection. We have procured two cylindrical detectors, 5"\times5", containing 1% crystal by mass. Crystal shards have a typical dimension of 1 mm. One detector was made with scintillating plastic, and one with nonscintillating plastic. Pulse shape analysis was used to reject gamma ray backgrounds. The scintillating detector was measured to have an intrinsic fast fission neutron efficiency of 0.4% and a gamma sensitivity of less than 2.3 \times 10-9, while the nonscintillating detector had a neutron efficiency of 0.7% and gamma sensitivity of (4.75\pm3.94)\times10-9. We determine that increasing the neutron detection efficiency by a factor of 2 will make the detector competitive with moderated 3He tubes, and we discuss several simple and straightforward methods for obtaining or surpassing such an improvement. We end with a discussion of possible applications, both for the scintillating-plastic and nonscintillating-plastic detectors.
△ Less
Submitted 16 September, 2011;
originally announced September 2011.
-
Sensitivity and Discovery Potential of CUORE to Neutrinoless Double-Beta Decay
Authors:
F. Alessandria,
R. Ardito,
D. R. Artusa,
F. T. Avignone III,
O. Azzolini,
M. Balata,
T. I. Banks,
G. Bari,
J. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
T. Bloxham,
C. Brofferio,
C. Bucci,
X. Z. Cai,
L. Canonica,
X. Cao,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Casali,
D. Chiesa,
N. Chott
, et al. (96 additional authors not shown)
Abstract:
We present a study of the sensitivity and discovery potential of CUORE, a bolometric double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso in Italy. Two approaches to the computation of experimental sensitivity for various background scenarios are presented, and an extension of the sensitivity formulation to the discovery potential case is also discussed. Assum…
▽ More
We present a study of the sensitivity and discovery potential of CUORE, a bolometric double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso in Italy. Two approaches to the computation of experimental sensitivity for various background scenarios are presented, and an extension of the sensitivity formulation to the discovery potential case is also discussed. Assuming a background rate of 10^-2 cts/(keV kg y), we find that, after 5 years of live time, CUORE has a 1 sigma sensitivity to the neutrinoless double-beta decay half-life of T_1/2(1 sigma) = 1.6 \times 10^26 y and thus a potential to probe the effective Majorana neutrino mass down to 40-100 meV; the sensitivity at 1.64 sigma, which corresponds to 90% C.L., will be T_1/2(1.64 sigma) = 9.5 \times 10^25 y. This range is compared with the claim of observation of neutrinoless double-beta decay in 76Ge and the preferred range of the neutrino mass parameter space from oscillation results.
△ Less
Submitted 20 March, 2013; v1 submitted 2 September, 2011;
originally announced September 2011.
-
CUORE crystal validation runs: results on radioactive contamination and extrapolation to CUORE background
Authors:
F. Alessandria,
E. Andreotti,
R. Ardito,
C. Arnaboldi,
F. T. Avignone III,
M. Balata,
I. Bandac,
T. I. Banks,
G. Bari,
J. W. Beeman,
F. Bellini,
A. Bersani,
M. Biassoni,
T. Bloxham,
C. Brofferio,
A. Bryant,
C. Bucci,
X. Z. Cai,
L. Canonica,
S. Capelli,
L. Carbone,
L. Cardani,
M. Carrettoni,
N. Chott,
M. Clemenza
, et al. (94 additional authors not shown)
Abstract:
The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performances and the radiopurity of the TeO$_2$ crystals produced at SICCAS (Shanghai Institute of Ceramics, Chinese Academy of Sciences) for the CUORE experiment. In this work the results of the first 5 validation runs are presented. Results have been…
▽ More
The CUORE Crystal Validation Runs (CCVRs) have been carried out since the end of 2008 at the Gran Sasso National Laboratories, in order to test the performances and the radiopurity of the TeO$_2$ crystals produced at SICCAS (Shanghai Institute of Ceramics, Chinese Academy of Sciences) for the CUORE experiment. In this work the results of the first 5 validation runs are presented. Results have been obtained for bulk contaminations and surface contaminations from several nuclides. An extrapolation to the CUORE background has been performed.
△ Less
Submitted 5 September, 2011; v1 submitted 24 August, 2011;
originally announced August 2011.
-
Double-beta decay of $^{130}$Te to the first 0$^{+}$ excited state of $^{130}$Xe with CUORICINO
Authors:
E. Andreotti,
C. Arnaboldi,
F. T. Avignone III,
M. Balata,
I. Bandac,
M. Barucci,
J. W. Beeman,
F. Bellini,
C. Brofferio,
A. Bryant,
C. Bucci,
L. Canonica,
S. Capelli,
L. Carbone,
M. Carrettoni,
M. Clemenza,
O. Cremonesi,
R. J. Creswick,
S. Di Domizio,
M. J. Dolinski,
L. Ejzak,
R. Faccini,
H. A. Farach,
E. Ferri,
E. Fiorini
, et al. (41 additional authors not shown)
Abstract:
The CUORICINO experiment was an array of 62 TeO$_{2}$ single-crystal bolometers with a total $^{130}$Te mass of $11.3\,$kg. The experiment finished in 2008 after more than 3 years of active operating time. Searches for both $0ν$ and $2ν$ double-beta decay to the first excited $0^{+}$ state in $^{130}$Xe were performed by studying different coincidence scenarios. The analysis was based on data repr…
▽ More
The CUORICINO experiment was an array of 62 TeO$_{2}$ single-crystal bolometers with a total $^{130}$Te mass of $11.3\,$kg. The experiment finished in 2008 after more than 3 years of active operating time. Searches for both $0ν$ and $2ν$ double-beta decay to the first excited $0^{+}$ state in $^{130}$Xe were performed by studying different coincidence scenarios. The analysis was based on data representing a total exposure of N($^{130}$Te)$\cdot$t=$9.5\times10^{25}\,$y. No evidence for a signal was found. The resulting lower limits on the half lives are $T^{2ν}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>1.3\times10^{23}\,$y (90% C.L.), and $T^{0ν}_{1/2}(^{130} Te\rightarrow^{130} Xe^{*})>9.4\times10^{23}\,$y (90% C.L.).
△ Less
Submitted 30 January, 2012; v1 submitted 22 August, 2011;
originally announced August 2011.
-
Combining Stochastics and Analytics for a Fast Monte Carlo Decay Chain Generator
Authors:
Kareem Kazkaz,
Nick Walsh
Abstract:
Various Monte Carlo programs, developed either by small groups or widely available, have been used to calculate the effects of decays of radioactive chains, from the original parent nucleus to the final stable isotopes. These chains include uranium, thorium, radon, and others, and generally have long-lived parent nuclei. Generating decays within these chains requires a certain amount of computing…
▽ More
Various Monte Carlo programs, developed either by small groups or widely available, have been used to calculate the effects of decays of radioactive chains, from the original parent nucleus to the final stable isotopes. These chains include uranium, thorium, radon, and others, and generally have long-lived parent nuclei. Generating decays within these chains requires a certain amount of computing overhead related to simulating unnecessary decays, time-ordering the final results in post-processing, or both. We present a combination analytic/stochastic algorithm for creating a time-ordered set of decays with position and time correlations, and starting with an arbitrary source age. Thus the simulation costs are greatly reduced, while at the same time avoiding chronological post-processing. We discuss optimization methods within the approach to minimize calculation time.
△ Less
Submitted 14 April, 2011;
originally announced April 2011.
-
130Te Neutrinoless Double-Beta Decay with CUORICINO
Authors:
E. Andreotti,
C. Arnaboldi,
F. T. Avignone III,
M. Balata,
I. Bandac,
M. Barucci,
J. W. Beeman,
F. Bellini,
C. Brofferio,
A. Bryant,
C. Bucci,
L. Canonica,
S. Capelli,
L. Carbone,
M. Carrettoni,
M. Clemenza,
O. Cremonesi,
R. J. Creswick,
S. Di Domizio,
M. J. Dolinski,
L. Ejzak,
R. Faccini,
H. A. Farach,
E. Ferri,
E. Fiorini
, et al. (41 additional authors not shown)
Abstract:
We report the final result of the CUORICINO experiment. Operated between 2003 and 2008, with a total exposure of 19.75 kg y of 130Te, CUORICINO was able to set a lower bound on the 130Te 0nDBD half-life of 2.8 10^{24} years at 90% C.L. The limit here reported includes the effects of systematic uncertainties that are examined in detail in the paper. The corresponding upper bound on the neutrino Maj…
▽ More
We report the final result of the CUORICINO experiment. Operated between 2003 and 2008, with a total exposure of 19.75 kg y of 130Te, CUORICINO was able to set a lower bound on the 130Te 0nDBD half-life of 2.8 10^{24} years at 90% C.L. The limit here reported includes the effects of systematic uncertainties that are examined in detail in the paper. The corresponding upper bound on the neutrino Majorana mass is in the range 300--710 meV, depending on the adopted nuclear matrix element evaluation.
△ Less
Submitted 15 December, 2010;
originally announced December 2010.
-
Search for beta plus/EC double beta decay of 120Te
Authors:
E. Andreotti,
C. Arnaboldi,
F. T. Avignone III,
M. Balata,
I. Bandac,
M. Barucci,
J. W. Beeman,
F. Bellini,
C. Brofferio,
A. Bryant,
C. Bucci,
L. Canonica,
S. Capelli,
L. Carbone,
M. Carrettoni,
M. Clemenza,
O. Cremonesi,
R. J. Creswick,
S. Di Domizio,
M. J. Dolinski,
L. Ejzak,
R. Faccini,
H. A. Farach,
E. Ferri,
E. Fiorini
, et al. (41 additional authors not shown)
Abstract:
We present a search for beta plus/EC double beta decay of 120Te performed with the CUORICINO experiment, an array of TeO2 cryogenic bolometers. After collecting 0.0573 kg y of 120Te, we see no evidence of a signal and therefore set the following limits on the half-life: T1/2 (0nu) > 1.9 10^{21} y at 90% C.L. for the 0 neutrino mode and T1/2 (2nu) > 7.6 10^{19} y at 90% C.L. for the two neutrino mo…
▽ More
We present a search for beta plus/EC double beta decay of 120Te performed with the CUORICINO experiment, an array of TeO2 cryogenic bolometers. After collecting 0.0573 kg y of 120Te, we see no evidence of a signal and therefore set the following limits on the half-life: T1/2 (0nu) > 1.9 10^{21} y at 90% C.L. for the 0 neutrino mode and T1/2 (2nu) > 7.6 10^{19} y at 90% C.L. for the two neutrino mode. These results improve the existing limits by almost three orders of magnitude (four in the case of 0 neutrino mode).
△ Less
Submitted 11 January, 2011; v1 submitted 22 November, 2010;
originally announced November 2010.
-
\textsc{MaGe} - a {\sc Geant4}-based Monte Carlo Application Framework for Low-background Germanium Experiments
Authors:
Melissa Boswell,
Yuen-Dat Chan,
Jason A. Detwiler,
Padraic Finnerty,
Reyco Henning,
Victor M. Gehman,
Rob A. Johnson,
David V. Jordan,
Kareem Kazkaz,
Markus Knapp,
Kevin Kröninger,
Daniel Lenz,
Lance Leviner,
Jing Liu,
Xiang Liu,
Sean MacMullin,
Michael G. Marino,
Akbar Mokhtarani,
Luciano Pandola,
Alexis G. Schubert,
Jens Schubert,
Claudia Tomei,
Oleksandr Volynets
Abstract:
We describe a physics simulation software framework, MAGE, that is based on the GEANT4 simulation toolkit. MAGE is used to simulate the response of ultra-low radioactive background radiation detectors to ionizing radiation, specifically the MAJORANA and GERDA neutrinoless double-beta decay experiments. MAJORANA and GERDA use high-purity germanium detectors to search for the neutrinoless double-bet…
▽ More
We describe a physics simulation software framework, MAGE, that is based on the GEANT4 simulation toolkit. MAGE is used to simulate the response of ultra-low radioactive background radiation detectors to ionizing radiation, specifically the MAJORANA and GERDA neutrinoless double-beta decay experiments. MAJORANA and GERDA use high-purity germanium detectors to search for the neutrinoless double-beta decay of 76Ge, and MAGE is jointly developed between these two collaborations. The MAGE framework contains the geometry models of common objects, prototypes, test stands, and the actual experiments. It also implements customized event generators, GEANT4 physics lists, and output formats. All of these features are available as class libraries that are typically compiled into a single executable. The user selects the particular experimental setup implementation at run-time via macros. The combination of all these common classes into one framework reduces duplication of efforts, eases comparison between simulated data and experiment, and simplifies the addition of new detectors to be simulated. This paper focuses on the software framework, custom event generators, and physics lists.
△ Less
Submitted 16 November, 2010;
originally announced November 2010.
-
Production of high purity TeO2 single crystals for the study of neutrinoless double beta decay
Authors:
C. Arnaboldi,
C. Brofferio,
A. Bryant,
C. Bucci,
L. Canonica,
S. Capelli,
M. Carrettoni,
M. Clemenza,
I. Dafinei,
S. Di Domizio,
F. Ferroni,
E. Fiorini,
Z. Ge,
A. Giachero,
L. Gironi,
A. Giuliani,
P. Gorla,
E. Guardincerri,
R. Kadel,
K. Kazkaz,
L. Kogler,
Y. Kolomensky,
J. Larsen,
M. Laubenstein,
Y. Li
, et al. (21 additional authors not shown)
Abstract:
High purity TeO2 crystals are produced to be used for the search for the neutrinoless double beta decay of 130Te. Dedicated production lines for raw material synthesis, crystal growth and surface processing were built compliant with radio-purity constraints specific to rare event physics experiments. High sensitivity measurements of radio-isotope concentrations in raw materials, reactants, consuma…
▽ More
High purity TeO2 crystals are produced to be used for the search for the neutrinoless double beta decay of 130Te. Dedicated production lines for raw material synthesis, crystal growth and surface processing were built compliant with radio-purity constraints specific to rare event physics experiments. High sensitivity measurements of radio-isotope concentrations in raw materials, reactants, consumables, ancillaries and intermediary products used for TeO2 crystals production are reported. Production and certification protocols are presented and resulting ready-to-use TeO2 crystals are described.
△ Less
Submitted 20 May, 2010;
originally announced May 2010.
-
Muon-induced backgrounds in the CUORICINO experiment
Authors:
E. Andreotti,
C. Arnaboldi,
F. T. Avignone III,
M. Balata,
I. Bandac,
M. Barucci,
J. W. Beeman,
F. Bellini,
T. Bloxham,
C. Brofferio,
A. Bryant,
C. Bucci,
L. Canonica,
S. Capelli,
L. Carbone,
M. Carrettoni,
M. Clemenza,
O. Cremonesi,
R. J. Creswick,
S. Di Domizio,
M. J. Dolinski,
L. Ejzak,
R. Faccini,
H. A. Farach,
E. Ferri
, et al. (46 additional authors not shown)
Abstract:
To better understand the contribution of cosmic ray muons to the CUORICINO background, 10 plastic scintillator detectors were installed at the CUORICINO site and operated during the final 3 months of the experiment. From these measurements, an upper limit of 0.0021 counts/(keV kg yr) (95% CL) was obtained on the cosmic ray-induced background in the neutrinoless double beta decay region of interest…
▽ More
To better understand the contribution of cosmic ray muons to the CUORICINO background, 10 plastic scintillator detectors were installed at the CUORICINO site and operated during the final 3 months of the experiment. From these measurements, an upper limit of 0.0021 counts/(keV kg yr) (95% CL) was obtained on the cosmic ray-induced background in the neutrinoless double beta decay region of interest. The measurements were also compared to Geant4 simulations.
△ Less
Submitted 21 June, 2010; v1 submitted 18 December, 2009;
originally announced December 2009.
-
MaGe - a Geant4-based Monte Carlo framework for low-background experiments
Authors:
Yuen-Dat Chan,
Jason A. Detwiler,
Reyco Henning,
Victor M. Gehman,
Rob A. Johnson,
David V. Jordan,
Kareem Kazkaz,
Markus Knapp,
Kevin Kroninger,
Daniel Lenz,
Jing Liu,
Xiang Liu,
Michael G. Marino,
Akbar Mokhtarani,
Luciano Pandola,
Alexis G. Schubert,
Claudia Tomei
Abstract:
A Monte Carlo framework, MaGe, has been developed based on the Geant4 simulation toolkit. Its purpose is to simulate physics processes in low-energy and low-background radiation detectors, specifically for the Majorana and Gerda $^{76}$Ge neutrinoless double-beta decay experiments. This jointly-developed tool is also used to verify the simulation of physics processes relevant to other low-backgr…
▽ More
A Monte Carlo framework, MaGe, has been developed based on the Geant4 simulation toolkit. Its purpose is to simulate physics processes in low-energy and low-background radiation detectors, specifically for the Majorana and Gerda $^{76}$Ge neutrinoless double-beta decay experiments. This jointly-developed tool is also used to verify the simulation of physics processes relevant to other low-background experiments in Geant4. The MaGe framework contains simulations of prototype experiments and test stands, and is easily extended to incorporate new geometries and configurations while still using the same verified physics processes, tunings, and code framework. This reduces duplication of efforts and improves the robustness of and confidence in the simulation output.
△ Less
Submitted 6 February, 2008;
originally announced February 2008.
-
Neutron Inelastic Scattering Processes as Background for Double-Beta Decay Experiments
Authors:
D. -M. Mei,
S. R. Elliott,
A. Hime,
V. Gehman,
K. Kazkaz
Abstract:
We investigate several Pb$(n,n'γ$) and Ge$(n,n'γ$) reactions. We measure $γ$-ray production from Pb$(n,n'γ$) reactions that can be a significant background for double-beta decay experiments which use lead as a massive inner shield. Particularly worrisome for Ge-based double-beta decay experiments are the 2041-keV and 3062-keV $γ$ rays produced via Pb$(n,n'γ$). The former is very close to the ^{7…
▽ More
We investigate several Pb$(n,n'γ$) and Ge$(n,n'γ$) reactions. We measure $γ$-ray production from Pb$(n,n'γ$) reactions that can be a significant background for double-beta decay experiments which use lead as a massive inner shield. Particularly worrisome for Ge-based double-beta decay experiments are the 2041-keV and 3062-keV $γ$ rays produced via Pb$(n,n'γ$). The former is very close to the ^{76}Ge double-beta decay endpoint energy and the latter has a double escape peak energy near the endpoint. Excitation $γ$-ray lines from Ge$(n,n'γ$) reactions are also observed. We consider the contribution of such backgrounds and their impact on the sensitivity of next-generation searches for neutrinoless double-beta decay using enriched germanium detectors.
△ Less
Submitted 26 January, 2008; v1 submitted 2 April, 2007;
originally announced April 2007.
-
Pulse shape analysis in segmented detectors as a technique for background reduction in Ge double-beta decay experiments
Authors:
S. R. Elliott,
V. M. Gehman,
K. Kazkaz,
D-M. Mei,
A. R. Young
Abstract:
The need to understand and reject backgrounds in Ge-diode detector double-beta decay experiments has given rise to the development of pulse shape analysis in such detectors to discern single-site energy deposits from multiple-site deposits. Here, we extend this analysis to segmented Ge detectors to study the effectiveness of combining segmentation with pulse shape analysis to identify the multip…
▽ More
The need to understand and reject backgrounds in Ge-diode detector double-beta decay experiments has given rise to the development of pulse shape analysis in such detectors to discern single-site energy deposits from multiple-site deposits. Here, we extend this analysis to segmented Ge detectors to study the effectiveness of combining segmentation with pulse shape analysis to identify the multiplicity of the energy deposits.
△ Less
Submitted 20 September, 2005;
originally announced September 2005.
-
Comment on "Evidence for Neutrinoless Double Beta Decay"
Authors:
C. E. Aalseth,
F. T. Avignone III,
A. Barabash,
F. Boehm,
R. L. Brodzinski,
J. I. Collar,
P. J. Doe,
H. Ejiri,
S. R. Elliott,
E. Fiorini,
R. J. Gaitskell,
G. Gratta,
R. Hazama,
K. Kazkaz,
G. S. King III,
R. T. Kouzes,
H. S. Miley,
M. K. Moe,
A. Morales,
J. Morales,
A. Piepke,
R. G. H. Robertson,
W. Tornow,
P. Vogel,
R. A. Warner
, et al. (1 additional authors not shown)
Abstract:
We comment on the recent claim for the experimental observation of neutrinoless double-beta decay. We discuss several limitations in the analysis provided in that paper and conclude that there is no basis for the presented claim.
We comment on the recent claim for the experimental observation of neutrinoless double-beta decay. We discuss several limitations in the analysis provided in that paper and conclude that there is no basis for the presented claim.
△ Less
Submitted 22 May, 2002; v1 submitted 7 February, 2002;
originally announced February 2002.