Multi-layer scintillation detector for the MOON double beta decay experiment: Scintillation photon responses studied by a prototype detector MOON-1
Authors:
H. Nakamura,
P. Doe,
H. Ejiri,
S. R. Elliott,
J. Engel,
M. Finger,
M. Finger. Jr,
K. Fushimi,
V. Gehman,
A. Gorin,
M. Greenfield,
V. H. Hai,
R. Hazama,
K. Higa,
T. Higashiguchi,
K. Ichihara,
Y. Ikegami,
J. Imoto,
H. Ishii,
T. Itahashi,
H. Kaneko,
P. Kavitov,
H. Kawasuso,
V. Kekelidze,
K. Matsuoka
, et al. (28 additional authors not shown)
Abstract:
An ensemble of multi-layer scintillators is discussed as an option of the high-sensitivity detector Mo Observatory Of Neutrinos (MOON) for spectroscopic measurements of neutrino-less double beta decays. A prototype detector MOON-1, which consists of 6 layer plastic-scintillator plates, was built to study the sensitivity of the MOON-type detector. The scintillation photon collection and the energ…
▽ More
An ensemble of multi-layer scintillators is discussed as an option of the high-sensitivity detector Mo Observatory Of Neutrinos (MOON) for spectroscopic measurements of neutrino-less double beta decays. A prototype detector MOON-1, which consists of 6 layer plastic-scintillator plates, was built to study the sensitivity of the MOON-type detector. The scintillation photon collection and the energy resolution, which are key elements for the high-sensitivity experiments, are found to be 1835+/-30 photo-electrons for 976 keV electrons and sigma = 2.9+/-0.1% (dE/E = 6.8+/-0.3 % in FWHM) at the Qbb ~ 3 MeV region, respectively. The multi-layer plastic-scintillator structure with good energy resolution as well as good background suppression of beta-gamma rays is crucial for the MOON-type detector to achieve the inverted hierarchy neutrino mass sensitivity.
△ Less
Submitted 12 September, 2006; v1 submitted 7 September, 2006;
originally announced September 2006.
The performance of thin NaI(Tl) scintillator plate for dark matter search
Authors:
K. Fushimi,
H. Kawasuso,
E. Aihara,
R. Hayami,
M. Toi,
K. Yasuda,
S. Nakayama,
N. Koori,
M. Nomachi,
K. Ichihara,
R. Hazama,
S. Yoshida,
S. Umehara,
K. Imagawa,
H. Ito
Abstract:
A thin (0.05cm) and wide area (5cmX5cm) NaI(Tl) scintillator was developed. The performance of the thin NaI(Tl) plate, energy resolution, single photoelectron energy and position sensitivity were tested. An excellent energy resolution of 20% (FWHM) at 60keV was obtained. The single photoelectron energy was calculated to be approximately 0.42 0.02keV. Position information in the 5cmx5cm area of t…
▽ More
A thin (0.05cm) and wide area (5cmX5cm) NaI(Tl) scintillator was developed. The performance of the thin NaI(Tl) plate, energy resolution, single photoelectron energy and position sensitivity were tested. An excellent energy resolution of 20% (FWHM) at 60keV was obtained. The single photoelectron energy was calculated to be approximately 0.42 0.02keV. Position information in the 5cmx5cm area of the detector was also obtained by analyzing the ratio of the number of photons collected at opposite ends of the detector. The position resolution was obtained to be 1cm (FWHM) in the 5cmx5cm area.
△ Less
Submitted 15 April, 2006; v1 submitted 8 December, 2005;
originally announced December 2005.