Backscattering Study of Electrons from 0.1 to 3.4 MeV
Authors:
M. Kanafani,
X. Fléchard,
O. Naviliat-Cuncic,
R. Garreau,
T. E. Haugen,
L. Hayen,
S. Leblond,
E. Liénard,
X. Mougeot,
G. Quéméner,
A. Rani,
J-C. Thomas,
S. Vanlangendonck
Abstract:
Benchmarking simulation codes for electron transport and scattering in matter is a crucial step for estimating uncertainties in many applications. However, experimental data for electron energies of a few MeV is scarce to make such comparisons. We report here the measurement and the quantitative analysis of backscattering probabilities of electrons in the energy range 0.1 to 3.4~MeV impinging on Y…
▽ More
Benchmarking simulation codes for electron transport and scattering in matter is a crucial step for estimating uncertainties in many applications. However, experimental data for electron energies of a few MeV is scarce to make such comparisons. We report here the measurement and the quantitative analysis of backscattering probabilities of electrons in the energy range 0.1 to 3.4~MeV impinging on YAP:Ce scintillator. The setup consists of a $2\times 2π$ calorimeter which enables, in particular, the inclusion of large incidence angles. The results are used to benchmark various scattering models incorporated in Geant4, showing relative deviations smaller than 5% between experiment and simulations. They demonstrate the current rather high reliability of the simulations when employing appropriate electromagnetic Physics Lists.
△ Less
Submitted 23 May, 2025;
originally announced May 2025.
High precision measurement of the $^6$He half-life
Authors:
M. Kanafani,
X. Fléchard,
O. Naviliat-Cuncic,
G. D. Chung,
S. Leblond,
E. Liénard,
X. Mougeot,
G. Quéméner,
A. Simancas Di Filippo,
J-C. Thomas
Abstract:
The half-life of $^{6}$He has been measured using a low energy radioactive beam implanted in a YAP scintillator and recording decay events in a 4$π$ geometry. Events were time-stamped with a digital data acquisition system enabling a reliable control of dead-time effects and detector gain variations. The result, $T_{1/2} = (807.25 \pm 0.16_{\rm stat} \pm 0.11_{\rm sys}$)~ms, provides the most prec…
▽ More
The half-life of $^{6}$He has been measured using a low energy radioactive beam implanted in a YAP scintillator and recording decay events in a 4$π$ geometry. Events were time-stamped with a digital data acquisition system enabling a reliable control of dead-time effects and detector gain variations. The result, $T_{1/2} = (807.25 \pm 0.16_{\rm stat} \pm 0.11_{\rm sys}$)~ms, provides the most precise value obtained so far and is consistent with the only previous measurement having a precision smaller than 0.1%. This resolves the longstanding discrepancy previously observed between two sets of measurements.
△ Less
Submitted 2 September, 2022; v1 submitted 13 July, 2022;
originally announced July 2022.