Nuclear recoil detection with color centers in bulk lithium fluoride
Authors:
Gabriela A. Araujo,
Laura Baudis,
Nathaniel Bowden,
Jordan Chapman,
Anna Erickson,
Mariano Guerrero Perez,
Adam A. Hecht,
Samuel C. Hedges,
Patrick Huber,
Vsevolod Ivanov,
Igor Jovanovic,
Giti A. Khodaparast,
Brenden A. Magill,
Jose Maria Mateos,
Maverick Morrison,
Nicholas W. G. Smith,
Patrick Stengel,
Stuti Surani,
Nikita Vladimirov,
Keegan Walkup,
Christian Wittweg,
Xianyi Zhang
Abstract:
We present initial results on nuclear recoil detection based on the fluorescence of color centers created by nuclear recoils in lithium fluoride. We use gamma rays, fast and thermal neutrons, and study the difference in responses they induce, showing that this type of detector is rather insensitive to gamma rays. We use light-sheet fluorescence microscopy to image nuclear recoil tracks from fast a…
▽ More
We present initial results on nuclear recoil detection based on the fluorescence of color centers created by nuclear recoils in lithium fluoride. We use gamma rays, fast and thermal neutrons, and study the difference in responses they induce, showing that this type of detector is rather insensitive to gamma rays. We use light-sheet fluorescence microscopy to image nuclear recoil tracks from fast and thermal neutron interactions deep inside a cubic-centimeter sized crystal and demonstrate automated feature extraction in three dimensions using machine learning tools. The number, size, and topology of the events agree with expectations based on simulations with TRIM. These results constitute the first step towards 10-1000g scale detectors with single-event sensitivity for applications such as the detection of dark matter particles, reactor neutrinos, and neutrons.
△ Less
Submitted 26 March, 2025;
originally announced March 2025.
-
Magneto-$ν$: Heavy neutral lepton search using $^{241}$Pu $β^-$ decays
Authors:
C. Lee,
X. Zhang,
A. Kavner,
T. Parsons-Davis,
D. Lee,
S. T. P. Boyd,
M. Loidl,
X. Mougeot,
M. Rodrigues,
M. K. Lee,
J. Song,
R. Wood,
I. Jovanovic,
G. B. Kim
Abstract:
We present experimental beta spectra of $^{241}$Pu as part of the Magneto-$ν$ experiment aimed at searching for keV heavy neutral leptons (HNLs). Total 200 million beta decays are measured by metallic magnetic calorimeters (MMCs), representing the highest statistical precision achieved for $^{241}$Pu to date. The end-point energy of $^{241}$Pu beta decay is measured via in-situ alpha calibration,…
▽ More
We present experimental beta spectra of $^{241}$Pu as part of the Magneto-$ν$ experiment aimed at searching for keV heavy neutral leptons (HNLs). Total 200 million beta decays are measured by metallic magnetic calorimeters (MMCs), representing the highest statistical precision achieved for $^{241}$Pu to date. The end-point energy of $^{241}$Pu beta decay is measured via in-situ alpha calibration, yielding a value of 21.52(2) keV. The differential decay rate of the first forbidden non-unique transition of $^{241}$Pu is described with a quadratic shape correction factor $C(w) = 1 - 1.931w + 0.940w^2$. Using these high-statistics spectra, we set an upper limit on the admixture of a 10.5\,keV sterile neutrino to the electron neutrino at $|U_{e4}|^2 < 2 \times 10^{-3}$ for HNL mass of 10.5\,keV.
△ Less
Submitted 24 March, 2025;
originally announced March 2025.
-
Measurement of Ionization Produced by 254 eVnr Nuclear Recoils in Germanium
Authors:
A. R. L. Kavner,
I. Jovanovic
Abstract:
Ionization produced by low-energy nuclear recoils is among the primary direct signatures of dark matter interactions. Despite the urgency of dark matter detection and the recent measurements of coherent elastic neutrino-nucleus scattering, detector response to nuclear recoils is not well characterized in the keVnr and sub-keVnr regime across a variety of materials. We have re-performed a measureme…
▽ More
Ionization produced by low-energy nuclear recoils is among the primary direct signatures of dark matter interactions. Despite the urgency of dark matter detection and the recent measurements of coherent elastic neutrino-nucleus scattering, detector response to nuclear recoils is not well characterized in the keVnr and sub-keVnr regime across a variety of materials. We have re-performed a measurement of the ionization produced by monoenergetic 254 eVnr nuclear recoils in Ge with improved digital electronics and additional systematic studies. Our results indicate an ionization yield of 64 +/- 8 eVee corresponding to a quenching factor of 25 +/- 3%, greater than the 14% predicted by the Lindhard model. This ionization enhancement could greatly improve the sensitivity of high-purity Ge detectors in dark matter detection and measurement of neutrinos via coherent scattering.
△ Less
Submitted 23 September, 2024; v1 submitted 16 May, 2024;
originally announced May 2024.
-
Evaluation of a Positron-Emission-Tomography-based SiPM readout for Compact Segmented Neutron Imagers
Authors:
Viacheslav A. Li,
Felicia Sutanto,
Timothy M. Classen,
Steven A. Dazeley,
Igor Jovanovic,
Tingshiuan C. Wu
Abstract:
Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural back…
▽ More
Gamma-ray emission from special nuclear material (SNM) is relatively easy to shield from detection using modest amounts of high-Z material. In contrast, fast-neutrons are much more penetrating and can escape relatively thick high-Z shielding without losing significant energy. Furthermore, fast neutrons provide a clear and unambiguous signature of the presence of SNM with few competing natural background sources. The challenge of detecting fast neutrons is twofold. First, the neutron flux from SNM are only a fraction of the corresponding gamma-ray flux. Second, fast neutrons can be difficult to differentiate from gamma rays. The ability to discriminate gamma rays from neutrons combined with neutron imaging can yield large benefit to isolate the localized SNM neutron source from background. With the recent developments of pulse-shape-sensitive plastic scintillators that offer excellent gamma-ray/neutron discrimination, and arrays of silicon photomultipliers combined with highly scalable and fast positron-emission-tomography (PET) multi-channel readout systems, field-deployable neutron imagers suitable for SNM detection might now be within reach. In this paper, we present a characterization of the performance of a recently available commercial PET-scanner readout, including its sensitivity to pulse-shape differences between fast neutrons and gamma rays, energy and timing resolution, as well as linearity and dynamic range. We find that, while the pulse-shape discrimination is achievable with stilbene, further improvement of the readout is required to achieve it with the best available plastic scintillators. The time and energy resolution appear to be adequate for neutron imaging in some circumstances.
△ Less
Submitted 15 February, 2022;
originally announced February 2022.
-
Nu Tools: Exploring Practical Roles for Neutrinos in Nuclear Energy and Security
Authors:
Oluwatomi Akindele,
Nathaniel Bowden,
Rachel Carr,
Andrew Conant,
Milind Diwan,
Anna Erickson,
Michael Foxe,
Bethany L. Goldblum,
Patrick Huber,
Igor Jovanovic,
Jonathan Link,
Bryce Littlejohn,
Pieter Mumm,
Jason Newby
Abstract:
For decades, physicists have used neutrinos from nuclear reactors to advance basic science. These pursuits have inspired many ideas for application of neutrino detectors in nuclear energy and security. While developments in neutrino detectors are now making some of these ideas technically feasible, their value in the context of real needs and constraints has been unclear. This report seeks to help…
▽ More
For decades, physicists have used neutrinos from nuclear reactors to advance basic science. These pursuits have inspired many ideas for application of neutrino detectors in nuclear energy and security. While developments in neutrino detectors are now making some of these ideas technically feasible, their value in the context of real needs and constraints has been unclear. This report seeks to help focus the picture of where neutrino technology may find practical roles in nuclear energy and security.
This report is the final product of the Nu Tools study, commissioned in 2019 by the DOE National Nuclear Security Administration (NNSA) Office of Defense Nuclear Nonproliferation Research and Development (DNN R&D). The study was conducted over two years by a group of neutrino physicists and nuclear engineers. A central theme of the study and this report is that useful application of neutrinos will depend not only on advancing physics and technology but also on understanding the needs and constraints of potential end-users.
The Study Approach emphasized broad end-user engagement. The major effort, undertaken from May to December 2020, was a series of engagements with the wider nuclear energy and security communities. Interviews with 41 experts revealed points of common understanding, which this report captures in three Cross-Cutting Findings, a Framework for Evaluating Utility, and seven Use Case Findings. The report concludes with two Recommendations. The findings and recommendations are summarized below. The respective ordering within each category does not represent a prioritization or implied value judgement.
△ Less
Submitted 20 December, 2021;
originally announced December 2021.
-
Discriminating Uranium Isotopes Based on Fission Signatures Induced by Delayed Neutrons
Authors:
Kristofer Ogren,
Jason Nattress,
Igor Jovanovic
Abstract:
The use of active interrogation (AI) to induce delayed neutron emission is a well-established technique for the characterization of special nuclear materials (SNM). Delayed neutrons have isotope-characteristic spectral and temporal signatures, which provide the basis for isotope identification. However, in bulk materials that contain an appreciable fissile (e.g., $^{235}$U or $^{233}$U) fraction,…
▽ More
The use of active interrogation (AI) to induce delayed neutron emission is a well-established technique for the characterization of special nuclear materials (SNM). Delayed neutrons have isotope-characteristic spectral and temporal signatures, which provide the basis for isotope identification. However, in bulk materials that contain an appreciable fissile (e.g., $^{235}$U or $^{233}$U) fraction, such as highly-enriched uranium (HEU), delayed neutrons have a high probability of inducing additional fissions. As a result, the overall delayed neutron signature consists of two distinct components: the "primary" delayed neutrons (emitted directly by fission fragments), and the "secondary prompt" fission neutrons produced in fission induced by primary delayed neutrons. These prompt products differ from "primary" delayed neutrons both in their energy spectra and in the presence of coincident radiation released by the parent fission event. The presence and relative quantity of prompt products from delayed fission depend on the cross-section of the material in the energy range of delayed neutrons, which may differ significantly between isotopes, thus providing an exploitable means for isotope differentiation. In this work, we demonstrate two experimental approaches for discriminating between $^{235}$U and $^{238}$U isotopes based on the measurement of delayed neutron-induced fission products. First, HEU and depleted uranium objects are differentiated through the detection of high-energy prompt neutrons from delayed fission using both recoil-based organic liquid scintillators and thermalization spectra from a custom-built capture-gated composite detector. Secondly, coincident radiation measurements are used as the basis for discrimination by comparing the overall rates and time evolution of fission events when delayed neutrons are present.
△ Less
Submitted 1 June, 2020; v1 submitted 13 November, 2019;
originally announced November 2019.
-
Characterization of the $^{12}$C(p,p')$^{12}$C Reaction (E$_p$=19.5$-$30 MeV) for Active Interrogation
Authors:
J. Nattress,
F. Sutanto,
P. -W. Fang,
Y. -Z. Chen,
A. Chen,
K. -Y. Chu,
T. S. Duh,
H. -Y. Tsai,
M. -W. Lin,
I. Jovanovic
Abstract:
Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation (AI), the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a pr…
▽ More
Passive detection of special nuclear material (SNM) is challenging due to its inherently low rate of spontaneous emission of penetrating radiation, the relative ease of shielding, and the fluctuating and frequently overwhelming background. Active interrogation (AI), the use of external radiation to increase the emission rate of characteristic radiation from SNM, has long been considered to be a promising method to overcome those challenges. Current AI systems that incorporate radiography tend to use bremsstrahlung beams, which can deliver high radiation doses. Low-energy ion-driven nuclear reactions that produce multiple monoenergetic photons may be used as an alternative. The $^{12}$C(p,p')$^{12}$C is one such reaction that could produce large gamma-ray yields of highly penetrating 4.4- and 15.1-MeV gamma rays. This reaction does not directly produce neutrons below the $\sim$19.7-MeV threshold, and the 15.1-MeV gamma-ray line is well matched to the photofission cross-section of $^{235}$U and $^{238}$U. We report the measurements of thick-target gamma-ray yields at 4.4 and 15.1 MeV from the $^{12}$C(p,p')$^{12}$C at proton energies of 19.5, 25, and 30 MeV. Measurements were made with two 3'' EJ309 cylindrical liquid scintillation detectors and thermoluminescent dosimeters placed at 0 and 90 degrees. We estimate the highest yields of the 4.4- and 15.1-MeV gamma rays of 1.65$\times10^{10}$ sr$^{-1}μ$ C$^{-1}$ and 4.47$\times10^8$ sr$^{-1}μ$ C$^{-1}$ at a proton energy of 30 MeV, respectively. The yield of 4.4 and 15.1 MeV gamma rays in all experimental configurations is greater than a comparable deuteron-driven reaction that produces the same gamma-ray energies- $^{11}$B(d,n$γ$)$^{12}$C. However, a two orders of magnitude increase of the neutron radiation dose is observed when the proton energy increases from 19.5 to 30 MeV.
△ Less
Submitted 27 May, 2020; v1 submitted 13 November, 2019;
originally announced November 2019.
-
Neutrino Detectors as Tools for Nuclear Security
Authors:
Adam Bernstein,
Nathaniel Bowden,
Bethany L. Goldblum,
Patrick Huber,
Igor Jovanovic,
John Mattingly
Abstract:
For over 40 years, physicists have considered possible uses for neutrino detectors in nuclear nonproliferation, arms control, and fissile materials security. Neutrinos are an attractive fission signature because they readily pass through matter. The same property makes neutrinos challenging to detect in systems that would be practical for nuclear security applications. This colloquium presents a b…
▽ More
For over 40 years, physicists have considered possible uses for neutrino detectors in nuclear nonproliferation, arms control, and fissile materials security. Neutrinos are an attractive fission signature because they readily pass through matter. The same property makes neutrinos challenging to detect in systems that would be practical for nuclear security applications. This colloquium presents a broad overview of several potential neutrino applications, including the near-field monitoring of known reactors, far-field monitoring of known or discovery of undeclared reactors, detection of reactor waste streams, and detection of nuclear explosions. We conclude that recent detector advances have made near-field monitoring feasible. Farther-field reactor detection and waste stream detection monitoring are possible in some cases with further research and development. Very long-range reactor monitoring and nuclear explosion detection do not appear feasible for the foreseeable future due to considerable physical and/or practical constraints.
△ Less
Submitted 25 March, 2020; v1 submitted 19 August, 2019;
originally announced August 2019.
-
A prototype for SANDD: A highly-segmented pulse-shape-sensitive plastic scintillator detector incorporating silicon photomultiplier arrays
Authors:
Viacheslav A. Li,
Timothy M. Classen,
Steven A. Dazeley,
Mark J. Duvall,
Igor Jovanovic,
Andrew N. Mabe,
Edward T. E. Reedy,
Felicia Sutanto
Abstract:
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will event…
▽ More
We report the first clear observation of neutron/gamma-ray pulse-shape sensitivity of a fully-instrumented 8 $\times$ 8 array of plastic scintillator segments coupled to two 5 cm $\times$ 5 cm 64-channel SiPM arrays as part of a study of the key metrics of a prototype antineutrino detector module designed for directional sensitivity. SANDD (a Segmented AntiNeutrino Directional Detector) will eventually comprise a central module of 64 elongated segments of $^{6}$Li-doped pulse-shape-sensitive scintillator rods, each with a square cross section of 5.4 mm $\times$ 5.4 mm, surrounded by larger cross section bars of the same material. The most important metrics with the potential to impact the performance of the central module of SANDD are neutron and gamma-ray pulse-shape sensitivity using silicon photomultipliers (SiPMs), particle identification via scintillator rod multiplicity, and energy and position resolution. As a first step, we constructed a prototype detector to investigate the performance of a central SANDD-like module using two 64-channel SiPM arrays and rods of undoped pulse-shape-sensitive plastic scintillator.
△ Less
Submitted 11 August, 2019; v1 submitted 27 March, 2019;
originally announced March 2019.
-
First measurement of the ionization yield of nuclear recoils in liquid argon
Authors:
T. H. Joshi,
S. Sangiorgio,
A. Bernstein,
M. Foxe,
C. Hagmann,
I. Jovanovic,
K. Kazkaz,
V. Mozin,
E. B. Norman,
S. V. Pereverzev,
F. Rebassoo,
P. Sorensen
Abstract:
This Letter details a measurement of the ionization yield ($Q_y$) of 6.7 keV $^{40}Ar$ atoms stopping in a liquid argon detector. The $Q_y$ of 3.6-6.3 detected $e^{-}/\mbox{keV}$, for applied electric fields in the range 240--2130 V/cm, is encouraging for the use of this detector medium to search for the signals from hypothetical dark matter particle interactions and from coherent elastic neutrino…
▽ More
This Letter details a measurement of the ionization yield ($Q_y$) of 6.7 keV $^{40}Ar$ atoms stopping in a liquid argon detector. The $Q_y$ of 3.6-6.3 detected $e^{-}/\mbox{keV}$, for applied electric fields in the range 240--2130 V/cm, is encouraging for the use of this detector medium to search for the signals from hypothetical dark matter particle interactions and from coherent elastic neutrino nucleus scattering. A significant dependence of $Q_y$ on the applied electric field is observed and explained in the context of ion recombination.
△ Less
Submitted 1 May, 2014; v1 submitted 10 February, 2014;
originally announced February 2014.
-
Coherent Scattering Investigations at the Spallation Neutron Source: a Snowmass White Paper
Authors:
D. Akimov,
A. Bernstein,
P. Barbeau,
P. Barton,
A. Bolozdynya,
B. Cabrera-Palmer,
F. Cavanna,
V. Cianciolo,
J. Collar,
R. J. Cooper,
D. Dean,
Y. Efremenko,
A. Etenko,
N. Fields,
M. Foxe,
E. Figueroa-Feliciano,
N. Fomin,
F. Gallmeier,
I. Garishvili,
M. Gerling,
M. Green,
G. Greene,
A. Hatzikoutelis,
R. Henning,
R. Hix
, et al. (32 additional authors not shown)
Abstract:
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, Tennessee, provides an intense flux of neutrinos in the few tens-of-MeV range, with a sharply-pulsed timing structure that is beneficial for background rejection. In this white paper, we describe how the SNS source can be used for a measurement of coherent elastic neutrino-nucleus scattering (CENNS), and the physics reach of dif…
▽ More
The Spallation Neutron Source (SNS) at Oak Ridge National Laboratory, Tennessee, provides an intense flux of neutrinos in the few tens-of-MeV range, with a sharply-pulsed timing structure that is beneficial for background rejection. In this white paper, we describe how the SNS source can be used for a measurement of coherent elastic neutrino-nucleus scattering (CENNS), and the physics reach of different phases of such an experimental program (CSI: Coherent Scattering Investigations at the SNS).
△ Less
Submitted 30 September, 2013;
originally announced October 2013.
-
First demonstration of a sub-keV electron recoil energy threshold in a liquid argon ionization chamber
Authors:
S. Sangiorgio,
T. H. Joshi,
A. Bernstein,
J. Coleman,
M. Foxe,
C. Hagmann,
I. Jovanovic,
K. Kazkaz,
K. Mavrokoridis,
V. Mozin,
S. Pereverzev,
P. Sorensen
Abstract:
We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV a…
▽ More
We describe the first demonstration of a sub-keV electron recoil energy threshold in a dual-phase liquid argon time projection chamber. This is an important step in an effort to develop a detector capable of identifying the ionization signal resulting from nuclear recoils with energies of order a few keV and below. We obtained this result by observing the peaks in the energy spectrum at 2.82 keV and 0.27 keV, following the K- and L-shell electron capture decay of Ar-37, respectively. The Ar-37 source preparation is described in detail, since it enables calibration that may also prove useful in dark matter direct detection experiments. An internally placed Fe-55 x-ray source simultaneously provided another calibration point at 5.9 keV. We discuss the ionization yield and electron recombination in liquid argon at those three calibration energies.
△ Less
Submitted 19 July, 2013; v1 submitted 17 January, 2013;
originally announced January 2013.