Skip to main content

Showing 1–19 of 19 results for author: Jebali, R

Searching in archive nucl-ex. Search in all archives.
.
  1. arXiv:2311.00725  [pdf, other

    physics.ins-det nucl-ex

    Light-yield response of liquid scintillators using 2--6 MeV tagged neutrons

    Authors: N. Mauritzson, K. G. Fissum, J. R. M. Annand, H. Perrey, R. Al Jebali, A. Backis, R. Hall-Wilton, K. Kanaki, V. Maulerova-Subert, F. Messi, R. J. W. Frost, E. Rofors, J. Scherzinger

    Abstract: Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study the scintillation light-yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event-by-event waveform digitization. Energy calibration was performed using a GEANT model to locate the edge p… ▽ More

    Submitted 24 November, 2023; v1 submitted 31 October, 2023; originally announced November 2023.

    Comments: 31 pages, 15 figures, 4 tables

  2. arXiv:2206.00948  [pdf, other

    physics.ins-det nucl-ex

    Technique for the measurement of intrinsic pulse-shape discrimination for organic scintillators using tagged neutrons

    Authors: N. Mauritzson, K. G. Fissum, J. R. M. Annand, H. Perrey, R. J. W. Frost, R. Al Jebali, A. Backis, R. Hall-Wilton, K. Kanaki, V. Maulerova-Subert, C. Maurer, F. Messi, E. Rofors

    Abstract: Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis. Gamma-ray sources and a Geant4-based simulation were used to calibrate the scintillation-light yield. The difference in pulse shape for the neutron and gamma-ray even… ▽ More

    Submitted 2 June, 2022; originally announced June 2022.

    Comments: 22 pages, 12 figures, 2 tables

  3. arXiv:2109.11963  [pdf, other

    physics.ins-det nucl-ex

    Geant4-based calibration of an organic liquid scintillator

    Authors: N. Mauritzson, K. G. Fissum, H. Perrey, J. R. M. Annand, R. J. W. Frost, R. Hall-Wilton, R. Al Jebali, K. Kanaki, V. Maulerova, F. Messi, E. Rofors

    Abstract: A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using both monoenergetic and polyenergetic gamma-ray sources. Scintillation light was detected in a photomultiplier tube, and the corresponding pulses were subjected to waveform digitization on an event-by-event basis. The resulting Compton edges have been analyzed using a Geant4 simulation of the detec… ▽ More

    Submitted 22 October, 2021; v1 submitted 24 September, 2021; originally announced September 2021.

    Comments: 20 pages, 8 figures, 4 tables

  4. arXiv:2010.06347  [pdf, other

    physics.ins-det nucl-ex

    Response of a Li-glass/multi-anode photomultiplier detector to collimated thermal-neutron beams

    Authors: E. Rofors, N. Mauritzson, H. Perrey, R. Al Jebali, J. R. M. Annand, L. Boyd, M. J. Christensen, U. Clemens, S. Desert, R. Engels, K. G. Fissum, H. Frielinghaus, C. Gheorghe, R. Hall-Wilton, S. Jaksch, K. Kanaki, S. Kazi, G. Kemmerling, I. Llamas Jansa, V. Maulerova, R. Montgomery, T. Richter, J. Scherzinger, B. Seitz, M. Shetty

    Abstract: The response of a position-sensitive Li-glass scintillator detector being developed for thermal-neutron detection with 6 mm position resolution has been investigated using collimated beams of thermal neutrons. The detector was moved perpendicularly through the neutron beams in 0.5 to 1.0 mm horizontal and vertical steps. Scintillation was detected in an 8 X 8 pixel multi-anode photomultiplier tube… ▽ More

    Submitted 9 December, 2020; v1 submitted 13 October, 2020; originally announced October 2020.

    Comments: 23 pages, 8 figures

  5. arXiv:2005.08675  [pdf, other

    physics.ins-det nucl-ex

    Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams

    Authors: E. Rofors, J. Pallon, R. Al Jebali, J. R. M. Annand, L. Boyd, M. J. Christensen, U. Clemens, S. Desert, M. Elfman, R. Engels, K. G. Fissum, H. Frielinghaus, R. Frost, S. Gardner, C. Gheorghe, R. Hall-Wilton, S. Jaksch, K. Kanaki, G. Kemmerling, P. Kristiansson, K. Livingston, V. Maulerova, N. Mauritzson, R. Montgomery, H. Perrey , et al. (4 additional authors not shown)

    Abstract: The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel… ▽ More

    Submitted 18 May, 2020; originally announced May 2020.

    Comments: 22 pages, 8 figures, to be submitted to Nucl. Instr. and Meth. in Phys. Res. A

  6. arXiv:1812.08854  [pdf, other

    physics.ins-det nucl-ex

    Response of a Li-glass/multi-anode photomultiplier detector to $α$-particles from $^{241}$Am

    Authors: E. Rofors, H. Perrey, R. Al Jebali, J. R. M. Annand, L. Boyd, U. Clemens, S. Desert, R. Engels, K. G. Fissum, H. Frielinghaus, C. Gheorghe, R. Hall-Wilton, S. Jaksch, A. Jalgén, K. Kanaki, G. Kemmerling, V. Maulerova, N. Mauritzson, R. Montgomery, J. Scherzinger, B. Seitz

    Abstract: The response of a position-sensitive Li-glass scintillator detector to $α$-particles from a collimated $^{241}$Am source scanned across the face of the detector has been measured. Scintillation light was read out by an 8 X 8 pixel multi-anode photomultiplier and the signal amplitude for each pixel has been recorded for every position on a scan. The pixel signal is strongly dependent on position an… ▽ More

    Submitted 19 December, 2018; originally announced December 2018.

    Comments: 23 pages, 7 figures, to be submitted to Nuclear Instruments and Methods in Physics Research Section A

  7. Near-threshold $π^-$ photoproduction on the deuteron

    Authors: B. Strandberg, K. G. Fissum, J. R. M. Annand, W. J. Briscoe, J. Brudvik, F. Cividini, L. Clark, E. J. Downie, K. England, G. Feldman, D. I. Glazier, K. Hamilton, K. Hansen, L. Isaksson, R. Al Jebali, M. A. Kovash, A. E. Kudryavtsev, V. Lensky, S. Lipschutz, M. Lundin, M. Meshkian, D. G. Middleton, L. S. Myers, D. O'Donnell, G. V. O'Rielly , et al. (7 additional authors not shown)

    Abstract: The first experimental investigation of the near-threshold cross section for incoherent $π^-$ photoproduction on the deuteron $γ$ d -> $π^-$ pp is presented. The experimental technique involved detection of the ~131 MeV gamma ray resulting from the radiative capture of photoproduced $π^-$ in the target. The total cross section has been measured using an unpolarized tagged-photon beam, a liquid-deu… ▽ More

    Submitted 6 December, 2019; v1 submitted 7 December, 2018; originally announced December 2018.

    Comments: 8 pages, 6 figures, to be submitted to Physical Review C

    Journal ref: Phys. Rev. C 101, 035207 (2020)

  8. Compton Scattering from the Deuteron above Pion-Production Threshold

    Authors: B. Strandberg, J. R. M. Annand, W. Briscoe, J. Brudvik, F. Cividini, L. Clark, E. J. Downie, K. England, G. Feldman, K. G. Fissum, D. I. Glazier, K. Hamilton, K. Hansen, L. Isaksson, R. Al Jebali, M. A. Kovash, S. Lipschutz, M. Lundin, M. Meshkian, D. G. Middleton, L. S. Myers, D. O'Donnell, G. O'Rielly, B. Oussena, M. F. Preston , et al. (4 additional authors not shown)

    Abstract: The electromagnetic polarizabilities of the nucleon are fundamental nucleon-structure observables that characterize its response to external electromagnetic fields. The neutron polarizabilities can be accessed from Compton-scattering data on light nuclear targets. Recent measurements of the differential cross section for Compton scattering on the deuteron below the pion-production threshold have d… ▽ More

    Submitted 20 March, 2018; originally announced March 2018.

    Comments: 6 pages, 4 figures, to be submitted to Physical Review C Rapid Communications

    Journal ref: Phys. Rev. C 98, 012201 (2018)

  9. Tagging fast neutrons from a 252Cf fission-fragment source

    Authors: Julius Scherzinger, Ramsey Al Jebali, John Annand, Kevin Fissum, Richard Hall-Wilton, Nicholai Mauritzson, Francesco Messi, Hanno Perrey, Emil Rofors

    Abstract: Coincidence and time-of-flight measurement techniques are employed to tag fission neutrons emitted from a 252Cf source sealed on one side with a very thin layer of Au. The source is positioned within a gaseous 4He scintillator detector. Together with alpha particles, both light and heavy fission fragments pass through the thin layer of Au and are detected. The fragments enable the corresponding fi… ▽ More

    Submitted 2 December, 2016; v1 submitted 9 November, 2016; originally announced November 2016.

    Comments: 15 pages, 8 figures, to be submitted to Applied Radiation and Isotopes

    Journal ref: Applied Radiation and Isotopes 127 (2017) 270-274

  10. arXiv:1611.00213  [pdf, ps, other

    physics.ins-det nucl-ex

    A comparison of untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe sources

    Authors: Julius Scherzinger, Ramsey Al Jebali, John Annand, Kevin Fissum, Richard Hall-Wilton, Sharareh Koufigar, Nicholai Mauritzson, Francesco Messi, Hanno Perrey, Emil Rofors

    Abstract: Untagged gamma-ray and tagged-neutron yields from 241AmBe and 238PuBe mixed-field sources have been measured. Gamma-ray spectroscopy measurements from 1 - 5 MeV were performed in an open environment using a CeBr3 detector and the same experimental conditions for both sources. The shapes of the distributions are very similar and agree well with previous data. Tagged-neutron measurements from 2 - 6… ▽ More

    Submitted 14 June, 2017; v1 submitted 1 November, 2016; originally announced November 2016.

    Comments: 16 pages, 6 figures

    Journal ref: Applied Radiation and Isotopes 127, 98-102 (2017)

  11. arXiv:1608.08778  [pdf, ps, other

    physics.ins-det nucl-ex

    The light-yield response of a NE-213 liquid-scintillator detector measured using 2 -- 6 MeV tagged neutrons

    Authors: J. Scherzinger, R. Al Jebali, J. R. M. Annand, K. G. Fissum, R. Hall-Wilton, K. Kanaki, M. Lundin, B. Nilsson, H. Perrey, A. Rosborg, H. Svensson

    Abstract: The response of a NE-213 liquid-scintillator detector has been measured using tagged neutrons from 2--6 MeV originating from an Am/Be neutron source. The neutron energies were determined using the time-of-flight technique. Pulse-shape discrimination was employed to discern between gamma-rays and neutrons. The behavior of both the fast (35 ns) and the combined fast and slow (475 ns) components of t… ▽ More

    Submitted 1 November, 2016; v1 submitted 31 August, 2016; originally announced August 2016.

    Comments: 10 pages, 7 figures, to be submitted to Nucl. Instr. and Meth. in Phys. Res. A, Referee comments addressed

    Journal ref: Nucl. Instr. and Meth. in Phys. Res. A 840 (2016) 121

  12. Compton Scattering from the Deuteron below Pion-Production Threshold

    Authors: Luke Myers, John Annand, Jason Brudvik, Gerald Feldman, Kevin Fissum, Harald Grießhammer, Kurt Hansen, Seth Henshaw, Lennart Isaksson, Ramsey Jebali, Michael Kovash, Magnus Lundin, Duncan Middleton, Alan Nathan, Bent Schröder, Sean Stave

    Abstract: Differential cross sections for elastic scattering of photons from the deuteron have recently been measured at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. These first new measurements in more than a decade further constrain the isoscalar electromagnetic polarizabilities of the nucleon and provide the first-ever results above 100 MeV, where the sensitivity to the polarizabi… ▽ More

    Submitted 27 March, 2015; originally announced March 2015.

    Comments: 13 pages, 8 figures, to be submitted to Physical Review C

    Journal ref: Phys. Rev. C 92, 025203 (2015)

  13. arXiv:1503.05545  [pdf, other

    physics.ins-det nucl-ex

    A Helium Gas-Scintillator Active Target for Photoreaction Measurements

    Authors: R. Al Jebali, J. R. M. Annand, J. -O. Adler, I. Akkurt, E. Buchanan, J. Brudvik, K. Fissum, S. Gardner, D. J. Hamilton, K. Hansen, L. Isaksson, K. Livingston, M. Lundin, J. C. McGeorge, I. J. D. MacGregor, R. MacRae, D. G. Middleton, A. J. H. Reiter, G. Rosner, B. Schröder, J. Sjögren, D. Sokhan, B. Strandberg

    Abstract: A multi-cell He gas-scintillator active target, designed for the measurement of photoreaction cross sections, is described. The target has four main chambers, giving an overall thickness of 0.103 $\mathrm{g/cm^{2}}$ at an operating pressure of 2 MPa. Scintillations are read out by photomultiplier tubes and the addition of small amounts of $\mathrm{N}_{2}$ to the He, to shift the scintillation emis… ▽ More

    Submitted 18 March, 2015; originally announced March 2015.

    Comments: 24 pages, 15 figures

  14. arXiv:1502.03931  [pdf, ps, other

    physics.ins-det nucl-ex

    A First Comparison of the responses of a He4-based fast-neutron detector and a NE-213 liquid-scintillator reference detector

    Authors: R. Jebali, J. Scherzinger, J. R. M. Annand, R. Chandra, G. Davatz, K. G. Fissum, H. Friederich, U. Gendotti, R. Hall-Wilton, E. Håkansson, K. Kanaki, M. Lundin, D. Murer, B. Nilsson, A. Rosborg, H. Svensson

    Abstract: A first comparison has been made between the pulse-shape discrimination characteristics of a novel $^{4}$He-based pressurized scintillation detector and a NE-213 liquid-scintillator reference detector using an Am/Be mixed-field neutron and gamma-ray source and a high-resolution scintillation-pulse digitizer. In particular, the capabilities of the two fast neutron detectors to discriminate between… ▽ More

    Submitted 27 April, 2015; v1 submitted 13 February, 2015; originally announced February 2015.

    Comments: 23 pages, 7 figures, Nuclear Instruments and Methods in Physics Research Section A review addressed

  15. New Measurement of Compton Scattering from the Deuteron and an Improved Extraction of the Neutron Electromagnetic Polarizabilities

    Authors: L. S. Myers, J. R. M. Annand, J. Brudvik, G. Feldman, K. G. Fissum, H. W. Grießhammer, K. Hansen, S. S. Henshaw, L. Isaksson, R. Jebali, M. A. Kovash, M. Lundin, J. A. McGovern, D. G. Middleton, A. M. Nathan, D. R. Phillips, B. Schröder, S. C. Stave

    Abstract: The electromagnetic polarizabilities of the nucleon are fundamental properties that describe its response to external electric and magnetic fields. They can be extracted from Compton-scattering data --- and have been, with good accuracy, in the case of the proton. In contradistinction, information for the neutron requires the use of Compton scattering from nuclear targets. Here we report a new mea… ▽ More

    Submitted 13 November, 2014; v1 submitted 12 September, 2014; originally announced September 2014.

    Comments: 6 pages, 3 figures, comments from Physical Review Letters Referees addressed

    Journal ref: Phys. Rev. Lett. 113, 262506 (2014)

  16. arXiv:1405.2686  [pdf, ps, other

    physics.ins-det nucl-ex

    Tagging fast neutrons from an 241Am/9Be source

    Authors: J. Scherzinger, J. R. M. Annand, G. Davatz, K. G. Fissum, U. Gendotti, R. Hall-Wilton, A. Rosborg, E. Håkansson, R. Jebali, K. Kanaki, M. Lundin, B. Nilsson, H. Svensson

    Abstract: We report on an investigation of the fast-neutron spectrum emitted by 241Am/9Be. Well-understood shielding, coincidence, and time-of-flight measurement techniques are employed to produce a continuous, polychromatic, energy-tagged neutron beam.

    Submitted 3 January, 2015; v1 submitted 12 May, 2014; originally announced May 2014.

    Comments: 17 pages, 7 figures, submitted to Journal of Applied Radiation and Isotopes

    Journal ref: Applied Radiation and Isotopes 98 (2015) 74

  17. Compton scattering from 12C using tagged photons in the energy range 65 - 115 MeV

    Authors: L. S. Myers, K. Shoniyozov, M. F. Preston, M. D. Anderson, J. R. M. Annand, M. Boselli, W. J. Briscoe, J. Brudvik, J. I. Capone, G. Feldman, K. G. Fissum, K. Hansen, S. S. Henshaw, L. Isaksson, R. Jebali, M. A. Kovash, K. Lewis, M. Lundin, I. J. D. MacGregor, D. G. Middleton, D. E. Mittelberger, M. Murray, A. M. Nathan, S. Nutbeam, G. V. O'Rielly , et al. (4 additional authors not shown)

    Abstract: Elastic scattering of photons from 12C has been investigated using quasi-monoenergetic tagged photons with energies in the range 65 - 115 MeV at laboratory angles of 60 deg, 120 deg, and 150 deg at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. A phenomenological model was employed to provide an estimate of the sensitivity of the 12C(g,g)12C cross section to the bound-nucleon… ▽ More

    Submitted 16 January, 2014; originally announced January 2014.

    Comments: 9 pages, 7 figures, to be submitted to Physical Review C

    Journal ref: Phys. Rev. C 89, 035202 (2014)

  18. arXiv:1311.5692  [pdf, ps, other

    physics.ins-det nucl-ex

    Tests of the Monte Carlo Simulation of the Photon-Tagger Focal-Plane Electronics at the MAX IV Laboratory

    Authors: M. F. Preston, L. S. Myers, J. R. M. Annand, K. G. Fissum, K. Hansen, L. Isaksson, R. Jebali, M. Lundin

    Abstract: Rate-dependent effects in the electronics used to instrument the tagger focal plane at the MAX IV Laboratory were recently investigated using the novel approach of Monte Carlo simulation to allow for normalization of high-rate experimental data acquired with single-hit time-to-digital converters (TDCs). The instrumentation of the tagger focal plane has now been expanded to include multi-hit TDCs.… ▽ More

    Submitted 22 November, 2013; originally announced November 2013.

    Comments: 10 pages, 8 figures, to be submitted to Nuclear Instruments and Methods in Physics Research Section A

    Journal ref: Nuclear Instruments and Methods in Physics Research Section A 744, 17 (2014)

  19. arXiv:1212.4050  [pdf, other

    physics.ins-det nucl-ex

    Suitability of high-pressure xenon as scintillator for gamma ray spectroscopy

    Authors: F. Resnati, U. Gendotti, R. Chandra, A. Curioni, G. Davatz, H. Frederich, A. Gendotti, L. Goeltl, R. Jebali, D. Murer, A. Rubbia

    Abstract: In this paper we report the experimental study of high-pressure xenon used as a scintillator, in the context of developing a gamma ray detector. We measure a light yield near 2 photoelectrons per keV for xenon at 40 bar. Together with the light yield, we also measured an energy resolution of ~9% (FWHM) at 662 keV, dominated by the statistical fluctuations in the number of photoelectrons.

    Submitted 17 December, 2012; originally announced December 2012.

    Comments: 15 pages, 11 figures