First application of mass measurement with the Rare-RI Ring reveals the solar r-process abundance trend at A=122 and A=123
Authors:
H. F. Li,
S. Naimi,
T. M. Sprouse,
M. R. Mumpower,
Y. Abe,
Y. Yamaguchi,
D. Nagae,
F. Suzaki,
M. Wakasugi,
H. Arakawa,
W. B. Dou,
D. Hamakawa,
S. Hosoi,
Y. Inada,
D. Kajiki,
T. Kobayashi,
M. Sakaue,
Y. Yokoda,
T. Yamaguchi,
R. Kagesawa,
D. Kamioka,
T. Moriguchi,
M. Mukai,
A. Ozawa,
S. Ota
, et al. (19 additional authors not shown)
Abstract:
The Rare-RI Ring (R3) is a recently commissioned cyclotron-like storage ring mass spectrometer dedicated to mass measurements of exotic nuclei far from stability at Radioactive Isotope Beam Factory (RIBF) in RIKEN. The first application of mass measurement using the R3 mass spectrometer at RIBF is reported. Rare isotopes produced at RIBF, $^{127}$Sn, $^{126}$In, $^{125}$Cd, $^{124}$Ag, $^{123}$Pd,…
▽ More
The Rare-RI Ring (R3) is a recently commissioned cyclotron-like storage ring mass spectrometer dedicated to mass measurements of exotic nuclei far from stability at Radioactive Isotope Beam Factory (RIBF) in RIKEN. The first application of mass measurement using the R3 mass spectrometer at RIBF is reported. Rare isotopes produced at RIBF, $^{127}$Sn, $^{126}$In, $^{125}$Cd, $^{124}$Ag, $^{123}$Pd, were injected in R3. Masses of $^{126}$In, $^{125}$Cd, and $^{123}$Pd were measured whereby the mass uncertainty of $^{123}$Pd was improved. This is the first reported measurement with a new storage ring mass spectrometery technique realized at a heavy-ion cyclotron and employing individual injection of the pre-identified rare nuclei. The latter is essential for the future mass measurements of the rarest isotopes produced at RIBF. The impact of the new $^{123}$Pd result on the solar $r$-process abundances in a neutron star merger event is investigated by performing reaction network calculations of 20 trajectories with varying electron fraction $Y_e$. It is found that the neutron capture cross section on $^{123}$Pd increases by a factor of 2.2 and $β$-delayed neutron emission probability, $P_\mathrm{1n}$, of $^{123}$Rh increases by 14\%. The neutron capture cross section on $^{122}$Pd decreases by a factor of 2.6 leading to pileup of material at $A=122$, thus reproducing the trend of the solar $r$-process abundances. The trend of the two-neutron separation energies (S$_\mathrm{2n}$) was investigated for the Pd isotopic chain. The new mass measurement with improved uncertainty excludes large changes of the S$_\mathrm{2n}$ value at $N=77$. Such large increase of the S$_\mathrm{2n}$ values before $N=82$ was proposed as an alternative to the quenching of the $N=82$ shell gap to reproduce $r$-process abundances in the mass region of $A=112-124$.
△ Less
Submitted 16 February, 2022; v1 submitted 9 December, 2021;
originally announced December 2021.
Development and operation of an electrostatic time-of-flight detector for the Rare RI storage Ring
Authors:
D. Nagae,
Y. Abe,
S. Okada,
S. Omika,
K. Wakayama,
S. Hosoi,
S. Suzuki,
T. Moriguchi,
M. Amano,
D. Kamioka,
Z. Ge,
S. Naimi,
F. Suzaki,
N. Tadano,
R. Igosawa,
K. Inomata,
H. Arakawa,
K. Nishimuro,
T. Fujii,
T. Mitsui,
Y. Yanagisawa,
H. Baba,
S. Michimasa,
S. Ota,
G. Lorusso
, et al. (6 additional authors not shown)
Abstract:
An electrostatic time-of-flight detector named E-MCP has been developed for quick diagnostics of circulating beam and timing measurement in mass spectrometry at the Rare-RI Ring in RIKEN. The E-MCP detector consists of a conversion foil, potential grids, and a microchannel plate. Secondary electrons are released from the surface of the foil when a heavy ion hits it. The electrons are accelerated a…
▽ More
An electrostatic time-of-flight detector named E-MCP has been developed for quick diagnostics of circulating beam and timing measurement in mass spectrometry at the Rare-RI Ring in RIKEN. The E-MCP detector consists of a conversion foil, potential grids, and a microchannel plate. Secondary electrons are released from the surface of the foil when a heavy ion hits it. The electrons are accelerated and deflected by 90$^\circ$ toward the microchannel plate by electrostatic potentials. A thin carbon foil and a thin aluminum-coated mylar foil were used as conversion foils. We obtained time resolutions of 69(1) ps and 43(1) ps (standard deviation) for a $^{84}$Kr beam at an energy of 170 MeV/u when using the carbon and the aluminum-coated mylar foils, respectively. A detection efficiency of approximately 90% was obtained for both foils. The E-MCP detector equipped with the carbon foil was installed inside the Rare-RI Ring to confirm particle circulation within a demonstration experiment on mass measurements of nuclei around $^{78}$Ge produced by in-flight fission of uranium beam at the RI Beam Factory in RIKEN. Periodic time signals from circulating ions were clearly observed. Revolution times for $^{78}$Ge, $^{77}$Ga, and $^{76}$Zn were obtained. The results confirmed successful circulation of the short-lived nuclei inside the Rare-RI Ring.
△ Less
Submitted 3 November, 2020;
originally announced November 2020.