-
The 3He(\vec n,p)3H parity-conserving asymmetry
Authors:
M. Viviani,
S. Baeßler,
L. Barrón-Palos,
N. Birge,
J. D. Bowman,
J. Calarco,
V. Cianciolo,
C. E. Coppola,
C. B. Crawford,
G. Dodson,
N. Fomin,
I. Garishvili,
M. T. Gericke,
L. Girlanda,
G. L. Greene,
G. M. Hale,
J. Hamblen,
C. Hayes,
E. B. Iverson,
M. L. Kabir,
A. Kievsky,
L. E. Marcucci,
M. McCrea,
E. Plemons,
A. Ramírez-Morales
, et al. (6 additional authors not shown)
Abstract:
Recently, the n$^3$He collaboration reported a measurement of the parity-violating (PV) proton directional asymmetry $A_{\mathrm {PV}} = (1.55\pm 0.97~\mathrm {(st\ at)} \pm 0.24~\mathrm {(sys)})\times 10^{-8}$ in the capture reaction of ${}^3$He$(\vec {n},{\mathrm p}){}^3$H at meV incident neutron energies. The result increased the limited inventory of precisely measured and calculable PV observa…
▽ More
Recently, the n$^3$He collaboration reported a measurement of the parity-violating (PV) proton directional asymmetry $A_{\mathrm {PV}} = (1.55\pm 0.97~\mathrm {(st\ at)} \pm 0.24~\mathrm {(sys)})\times 10^{-8}$ in the capture reaction of ${}^3$He$(\vec {n},{\mathrm p}){}^3$H at meV incident neutron energies. The result increased the limited inventory of precisely measured and calculable PV observables in few-body systems required to further understand the structure of hadronic weak interaction. In this letter, we report the experimental and theoretical investigation of a parity conserving (PC) asymmetry $A_{\mathrm {PC}}$ in the same reaction (the first ever measured PC observable at meV neutron energies). As a result of S- and P-wave mixing in the reaction, the $A_{\mathrm {PC}}$ is inversely proportional to the neutron wavelength $λ$. The experimental value is $(λ\times A_{\mathrm {PC}})\equivβ= (-1.97 \pm 0.28~\mathrm{(stat)}\pm 0.12~\mathrm{(sys)}) \times 10^{-6}$ Amstrongs. We present results for a theoretical analysis of this reaction by solving the four-body scattering problem within the hyperspherical harmonic method. We find that in the ${}^3$He$(\vec {n},{\mathrm p}){}^3$H reaction, $A_{\mathrm {PC}}$ depends critically on the energy and width of the close $0^-$ resonant state of ${}^4$He, resulting in a large sensitivity to the spin-orbit components of the nucleon-nucleon force and even to the three-nucleon force. The analysis of the accurately measured $A_{\mathrm {PC}}$ and $A_{\mathrm {PV}}$ using the same few-body theoretical models gives essential information needed to interpret the PV asymmetry in the ${}^3$He$(\vec {n}, {\mathrm p}){}^3$H reaction.
△ Less
Submitted 16 May, 2024;
originally announced May 2024.
-
Fundamental Neutron Physics: a White Paper on Progress and Prospects in the US
Authors:
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
D. H. Beck,
T. Bhattacharya,
M. Blatnik,
T. J. Bowles,
J. D. Bowman,
J. Brewington,
L. J. Broussard,
A. Bryant,
J. F. Burdine,
J. Caylor,
Y. Chen,
J. H. Choi,
L. Christie,
T. E. Chupp,
V. Cianciolo,
V. Cirigliano,
S. M. Clayton,
B. Collett,
C. Crawford,
W. Dekens,
M. Demarteau,
D. DeMille
, et al. (66 additional authors not shown)
Abstract:
Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with orders of magnitude more sensitivity, provide new data on the Cabibbo anomaly, more precisely measure the neutron lifetime and decay, and explore hadr…
▽ More
Fundamental neutron physics, combining precision measurements and theory, probes particle physics at short range with reach well beyond the highest energies probed by the LHC. Significant US efforts are underway that will probe BSM CP violation with orders of magnitude more sensitivity, provide new data on the Cabibbo anomaly, more precisely measure the neutron lifetime and decay, and explore hadronic parity violation. World-leading results from the US Fundamental Neutron Physics community since the last Long Range Plan, include the world's most precise measurement of the neutron lifetime from UCN$τ$, the final results on the beta-asymmetry from UCNA and new results on hadronic parity violation from the NPDGamma and n-${^3}$He runs at the FNPB (Fundamental Neutron Physics Beamline), precision measurement of the radiative neutron decay mode and n-${}^4$He at NIST. US leadership and discovery potential are ensured by the development of new high-impact experiments including BL3, Nab, LANL nEDM and nEDM@SNS. On the theory side, the last few years have seen results for the neutron EDM from the QCD $θ$ term, a factor of two reduction in the uncertainty for inner radiative corrections in beta-decay which impacts CKM unitarity, and progress on {\it ab initio} calculations of nuclear structure for medium-mass and heavy nuclei which can eventually improve the connection between nuclear and nucleon EDMs. In order to maintain this exciting program and capitalize on past investments while also pursuing new ideas and building US leadership in new areas, the Fundamental Neutron Physics community has identified a number of priorities and opportunities for our sub-field covering the time-frame of the last Long Range Plan (LRP) under development. This white paper elaborates on these priorities.
△ Less
Submitted 17 August, 2023;
originally announced August 2023.
-
Comments on Systematic Effects in the NIST Beam Neutron Lifetime Experiment
Authors:
F. E. Wietfeldt,
R. Biswas,
J. Caylor,
B. Crawford,
M. S. Dewey,
N. Fomin,
G. L. Greene,
C. C. Haddock,
S. F. Hoogerheide,
H. P. Mumm,
J. S. Nico,
W. M. Snow,
J. Zuchegno
Abstract:
We discuss issues raised by Serebrov, et al. in a recent paper regarding systematic effects in the beam neutron lifetime experiment performed at NIST. We show that these effects were considered in the original analyses and that our corrections and systematic uncertainties were appropriate. We point out some misconceptions and erroneous assumptions in the analysis of Serebrov, et al. None of the is…
▽ More
We discuss issues raised by Serebrov, et al. in a recent paper regarding systematic effects in the beam neutron lifetime experiment performed at NIST. We show that these effects were considered in the original analyses and that our corrections and systematic uncertainties were appropriate. We point out some misconceptions and erroneous assumptions in the analysis of Serebrov, et al. None of the issues raised in Serebrov, et al lead us to alter the value of the neutron lifetime reported previously.
△ Less
Submitted 29 September, 2022;
originally announced September 2022.
-
Measurement of the Parity-Odd Angular Distribution of Gamma Rays From Polarized Neutron Capture on $^{35}$Cl
Authors:
N. Fomin,
R. Alarcon,
L. Alonzi,
E. Askanazi,
S. Baeßler,
S. Balascuta,
L. Barrón-Palos,
A. Barzilov,
D. Blyth,
J. D. Bowman,
N. Birge,
J. R. Calarco,
T. E. Chupp,
V. Cianciolo,
C. E. Coppola,
C. B. Crawford,
K. Craycraft,
D. Evans,
C. Fieseler,
E. Frlež,
J. Fry,
I. Garishvili,
M. T. W. Gericke,
R. C. Gillis,
K. B. Grammer
, et al. (39 additional authors not shown)
Abstract:
We report a measurement of two energy-weighted gamma cascade angular distributions from polarized slow neutron capture on the ${}^{35}$Cl nucleus, one parity-odd correlation proportional to $\vec{s_{n}} \cdot \vec{k_γ}$ and one parity-even correlation proportional to $\vec{s_{n}} \cdot \vec{k_{n}} \times \vec{k_γ}$. A parity violating asymmetry can appear in this reaction due to the weak nucleon-n…
▽ More
We report a measurement of two energy-weighted gamma cascade angular distributions from polarized slow neutron capture on the ${}^{35}$Cl nucleus, one parity-odd correlation proportional to $\vec{s_{n}} \cdot \vec{k_γ}$ and one parity-even correlation proportional to $\vec{s_{n}} \cdot \vec{k_{n}} \times \vec{k_γ}$. A parity violating asymmetry can appear in this reaction due to the weak nucleon-nucleon (NN) interaction which mixes opposite parity S and P-wave levels in the excited compound $^{36}$Cl nucleus formed upon slow neutron capture. If parity-violating (PV) and parity-conserving (PC) terms both exist, the measured differential cross section can be related to them via $\frac{dσ}{dΩ}\propto1+A_{γ, PV}\cosθ+A_{γ,PC}\sinθ$. The PV and PC asymmetries for energy-weighted gamma cascade angular distributions for polarized slow neutron capture on $^{35}$Cl averaged over the neutron energies from 2.27~meV to 9.53~meV were measured to be $A_{γ,PV}=(-23.9\pm0.7)\times 10^{-6}$ and $A_{γ,PC}=(0.1\pm0.7)\times 10^{-6}$. These results are consistent with previous experimental results. Systematic errors were quantified and shown to be small compared to the statistical error. These asymmetries in the angular distributions of the gamma rays emitted from the capture of polarized neutrons in $^{35}$Cl were used to verify the operation and data analysis procedures for the NPDGamma experiment which measured the parity-odd asymmetry in the angular distribution of gammas from polarized slow neutron capture on protons.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.
-
First Precision Measurement of the Parity Violating Asymmetry in Cold Neutron Capture on $^3$He
Authors:
n3He Collaboration,
M. T. Gericke,
S. Baeßler,
L. Barrón-Palos,
N. Birge,
J. D. Bowman,
C. Britton Jr.,
J. Calarco,
V. Cianciolo,
C. E. Coppola,
C. B. Crawford,
D. Ezell,
N. Fomin,
I. Garishvili,
G. L. Greene,
G. M. Hale,
J. Hamblen,
C. Hayes,
E. Iverson,
M. L. Kabir,
M. McCrea,
P. E. Mueller,
I. Novikov,
S. Penttila,
E. Plemons
, et al. (4 additional authors not shown)
Abstract:
We report the first precision measurement of the parity-violating asymmetry in the direction of proton emission with respect to the neutron spin, in the reaction $^{3}\mathrm{He}(\mathrm{n},\mathrm{p})^{3}\mathrm{H}$, using the capture of polarized cold neutrons in an unpolarized active $^3\rm{He}$ target. The asymmetry is a result of the weak interaction between nucleons, which remains one of the…
▽ More
We report the first precision measurement of the parity-violating asymmetry in the direction of proton emission with respect to the neutron spin, in the reaction $^{3}\mathrm{He}(\mathrm{n},\mathrm{p})^{3}\mathrm{H}$, using the capture of polarized cold neutrons in an unpolarized active $^3\rm{He}$ target. The asymmetry is a result of the weak interaction between nucleons, which remains one of the most poorly understood aspects of electro-weak theory. The measurement provides an important benchmark for modern effective field theory (EFT) calculations. Measurements like this are necessary to determine the spin-isospin structure of the hadronic weak interaction. Our asymmetry result is $A_{PV} = \left( 1.58 \pm 0.97 ~\mathrm{(stat)} \pm 0.24~\mathrm{(sys)}\right)\times10^{-8}$, which has the smallest uncertainty of any parity-violating asymmetry measurement so far.
△ Less
Submitted 28 April, 2020; v1 submitted 24 April, 2020;
originally announced April 2020.
-
The n$^3$He Experiment: Parity Violation in Polarized Neutron Capture on $^{3}$He
Authors:
n3He Collaboration,
M. McCrea,
M. L. Kabir,
N. Birge,
C. E. Coppola,
C. Hayes,
E. Plemons,
A. Ramírez-Morales,
E. M. Scott,
J. Watts,
S. Baessler,
L. Barrón-Palos,
J. D. Bowman,
C. Britton Jr.,
J. Calarco,
V. Cianciolo,
C. B. Crawford,
D. Ezell,
N. Fomin,
I. Garishvili,
M. T. Gericke,
G. L. Greene,
G. M. Hale,
J. Hamblen,
E. Iverson
, et al. (4 additional authors not shown)
Abstract:
Significant progress has been made to experimentally determine a complete set of the parity-violating (PV) weak-interaction amplitudes between nucleons. In this paper we describe the design, construction and operation of the n$^3$He experiment that was used to measure the PV asymmetry $A_{\mathrm{PV}}$ in the direction of proton emission in the reaction…
▽ More
Significant progress has been made to experimentally determine a complete set of the parity-violating (PV) weak-interaction amplitudes between nucleons. In this paper we describe the design, construction and operation of the n$^3$He experiment that was used to measure the PV asymmetry $A_{\mathrm{PV}}$ in the direction of proton emission in the reaction $\vec{\mathrm{n}} + {^3}\mathrm{He} \rightarrow {^3}\mathrm{H} + \mathrm{p}$, using the capture of polarized cold neutrons in an unpolarized gaseous $^3\mathrm{He}$ target. This asymmetry has was recently calculated \cite{Viviani,Viviani2}, both in the traditional style meson exchange picture, and in effective field theory (EFT), including two-pion exchange. The high precision result (published separately) obtained with the experiment described herein forms an important benchmark for hadronic PV (HPV) theory in few-body systems, where precise calculations are possible. To this day, HPV is still one of the most poorly understood aspects of the electro-weak theory. The calculations estimate the size of the asymmetry to be in the range of $(-9.4 \rightarrow 3.5)\times 10^{-8}$, depending on the framework or model. The small size of the asymmetry and the small overall goal uncertainty of the experiment of $δA_{\mathrm{PV}} \simeq 1\times10^{-8}$ places strict requirements on the experiment, especially on the design of the target-detector chamber. In this paper we describe the experimental setup and the measurement methodology as well as the detailed design of the chamber, including results of Garfield++ and Geant4 simulations that form the basis of the chamber design and analysis. We also show data from commissioning and production and define the systematic errors that the chamber contributes to the measured $A_{\mathrm{PV}}$. We give the final uncertainty on the measurement.
△ Less
Submitted 22 April, 2020;
originally announced April 2020.
-
A Comment on "The possible explanation of neutron lifetime beam anomaly" by A. P. Serebrov, et al
Authors:
F. E. Wietfeldt,
R. Biswas,
R. W. Haun,
M. S. Dewey,
J. Caylor,
N. Fomin,
G. L. Greene,
C. C. Haddock,
S. F. Hoogerheide,
H. P. Mumm,
J. S. Nico,
B. Crawford,
W. M. Snow
Abstract:
We comment on a recent manuscript by A. P. Serebrov, et al. regarding residual gas charge exchange in the beam neutron lifetime experiment
We comment on a recent manuscript by A. P. Serebrov, et al. regarding residual gas charge exchange in the beam neutron lifetime experiment
△ Less
Submitted 2 April, 2020;
originally announced April 2020.
-
The neutron electric dipole moment experiment at the Spallation Neutron Source
Authors:
K. K. H. Leung,
M. Ahmed,
R. Alarcon,
A. Aleksandrova,
S. Baeßler,
L. Barrón-Palos,
L. Bartoszek,
D. H. Beck,
M. Behzadipour,
J. Bessuille,
M. A. Blatnik,
M. Broering,
L. J. Broussard,
M. Busch,
R. Carr,
P. -H. Chu,
V. Cianciolo,
S. M. Clayton,
M. D. Cooper,
C. Crawford,
S. A. Currie,
C. Daurer,
R. Dipert,
K. Dow,
D. Dutta
, et al. (68 additional authors not shown)
Abstract:
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarize…
▽ More
Novel experimental techniques are required to make the next big leap in neutron electric dipole moment experimental sensitivity, both in terms of statistics and systematic error control. The nEDM experiment at the Spallation Neutron Source (nEDM@SNS) will implement the scheme of Golub & Lamoreaux [Phys. Rep., 237, 1 (1994)]. The unique properties of combining polarized ultracold neutrons, polarized $^3$He, and superfluid $^4$He will be exploited to provide a sensitivity to $\sim 10^{-28}\,e{\rm \,\cdot\, cm}$. Our cryogenic apparatus will deploy two small ($3\,{\rm L}$) measurement cells with a high density of ultracold neutrons produced and spin analyzed in situ. The electric field strength, precession time, magnetic shielding, and detected UCN number will all be enhanced compared to previous room temperature Ramsey measurements. Our $^3$He co-magnetometer offers unique control of systematic effects, in particular the Bloch-Siegert induced false EDM. Furthermore, there will be two distinct measurement modes: free precession and dressed spin. This will provide an important self-check of our results. Following five years of "critical component demonstration," our collaboration transitioned to a "large scale integration" phase in 2018. An overview of our measurement techniques, experimental design, and brief updates are described in these proceedings.
△ Less
Submitted 4 October, 2019; v1 submitted 6 March, 2019;
originally announced March 2019.
-
The Nab Experiment: A Precision Measurement of Unpolarized Neutron Beta Decay
Authors:
J. Fry,
R. Alarcon,
S. Baessler,
S. Balascuta,
L. Barron-Palos,
T. Bailey,
K. Bass,
N. Birge,
A. Blose,
D. Borissenko,
J. D. Bowman,
L. J. Broussard,
A. T. Bryant,
J. Byrne,
J. R. Calarco,
J. Caylor,
K. Chang,
T. Chupp,
T. V. Cianciolo,
C. Crawford,
X. Ding,
M. Doyle,
W. Fan,
W. Farrar,
N. Fomin
, et al. (47 additional authors not shown)
Abstract:
Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, $λ= g_A / g_V$, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlati…
▽ More
Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, $λ= g_A / g_V$, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlation parameter $a$ with a precision of $δa / a = 10^{-3}$ and the Fierz interference term $b$ to $δb = 3\times10^{-3}$ in unpolarized free neutron beta decay. These results, along with a more precise measurement of the neutron lifetime, aim to deliver an independent determination of the ratio $λ$ with a precision of $δλ/ λ= 0.03\%$ that will allow an evaluation of $V_{ud}$ and sensitively test CKM unitarity, independent of nuclear models. Nab utilizes a novel, long asymmetric spectrometer that guides the decay electron and proton to two large area silicon detectors in order to precisely determine the electron energy and an estimation of the proton momentum from the proton time of flight. The Nab spectrometer is being commissioned at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source at Oak Ridge National Lab. We present an overview of the Nab experiment and recent updates on the spectrometer, analysis, and systematic effects.
△ Less
Submitted 7 January, 2020; v1 submitted 25 November, 2018;
originally announced November 2018.
-
First Observation of $P$-odd $γ$ Asymmetry in Polarized Neutron Capture on Hydrogen
Authors:
D. Blyth,
J. Fry,
N. Fomin,
R. Alarcon,
L. Alonzi,
E. Askanazi,
S. Baeßler,
S. Balascuta,
L. Barrón-Palos,
A. Barzilov,
J. D. Bowman,
N. Birge,
J. R. Calarco,
T. E. Chupp,
V. Cianciolo,
C. E. Coppola,
C. B. Crawford,
K. Craycraft,
D. Evans,
C. Fieseler,
E. Frlež,
I. Garishvili,
M. T. W. Gericke,
R. C. Gillis,
K. B. Grammer
, et al. (39 additional authors not shown)
Abstract:
We report the first observation of the parity-violating 2.2 MeV gamma-ray asymmetry $A^{np}_γ$ in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. $A^{np}_γ$ isolates the $ΔI=1$, \mbox{$^{3}S_{1}\rightarrow {^{3}P_{1}}$} component of the weak nucleon-nucleon interaction, which is dominat…
▽ More
We report the first observation of the parity-violating 2.2 MeV gamma-ray asymmetry $A^{np}_γ$ in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. $A^{np}_γ$ isolates the $ΔI=1$, \mbox{$^{3}S_{1}\rightarrow {^{3}P_{1}}$} component of the weak nucleon-nucleon interaction, which is dominated by pion exchange and can be directly related to a single coupling constant in either the DDH meson exchange model or pionless EFT. We measured $A^{np}_γ= [-3.0 \pm 1.4 (stat) \pm 0.2 (sys)]\times 10^{-8}$, which implies a DDH weak $πNN$ coupling of $h_π^{1} = [2.6 \pm 1.2(stat) \pm 0.2(sys)] \times 10^{-7}$ and a pionless EFT constant of $C^{^{3}S_{1}\rightarrow ^{3}P_{1}}/C_{0}=[-7.4 \pm 3.5 (stat) \pm 0.5 (sys)] \times 10^{-11}$ MeV$^{-1}$. We describe the experiment, data analysis, systematic uncertainties, and the implications of the result.
△ Less
Submitted 14 December, 2018; v1 submitted 26 July, 2018;
originally announced July 2018.
-
Measurement of the absolute neutron beam polarization from a supermirror polarizer and the absolute efficiency of a neutron spin rotator for the NPDGamma experiment using a polarized $^{3}$He neutron spin-filter
Authors:
M. M. Musgrave,
S. Baessler,
S. Balascuta,
L. Barron-Palos,
D. Blyth,
J. D. Bowman,
T. E. Chupp,
V. Cianciolo,
C. Crawford,
K. Craycraft,
N. Fomin,
J. Fry,
M. Gericke,
R. C. Gillis,
K. Grammer,
G. L. Greene,
J. Hamblen,
C. Hayes,
P. Huffman,
C. Jiang,
S. Kucuker,
M. McCrea,
P. E. Mueller,
S. I. Penttila,
W. M. Snow
, et al. (4 additional authors not shown)
Abstract:
Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of $\sim10^9$ neutrons per seco…
▽ More
Accurately measuring the neutron beam polarization of a high flux, large area neutron beam is necessary for many neutron physics experiments. The Fundamental Neutron Physics Beamline (FnPB) at the Spallation Neutron Source (SNS) is a pulsed neutron beam that was polarized with a supermirror polarizer for the NPDGamma experiment. The polarized neutron beam had a flux of $\sim10^9$ neutrons per second per cm$^2$ and a cross sectional area of 10$\times$12~cm$^2$. The polarization of this neutron beam and the efficiency of a RF neutron spin rotator installed downstream on this beam were measured by neutron transmission through a polarized $^{3}$He neutron spin-filter. The pulsed nature of the SNS enabled us to employ an absolute measurement technique for both quantities which does not depend on accurate knowledge of the phase space of the neutron beam or the $^{3}$He polarization in the spin filter and is therefore of interest for any experiments on slow neutron beams from pulsed neutron sources which require knowledge of the absolute value of the neutron polarization. The polarization and spin-reversal efficiency measured in this work were done for the NPDGamma experiment, which measures the parity violating $γ$-ray angular distribution asymmetry with respect to the neutron spin direction in the capture of polarized neutrons on protons. The experimental technique, results, systematic effects, and applications to neutron capture targets are discussed.
△ Less
Submitted 3 April, 2018; v1 submitted 26 March, 2018;
originally announced March 2018.
-
Precision determination of absolute neutron flux
Authors:
A. T. Yue,
E. S. Anderson,
M. S. Dewey,
D. M. Gilliam,
G. L. Greene,
A. B. Laptev,
J. S. Nico,
W. M. Snow
Abstract:
A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using a method of an alpha-gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed…
▽ More
A technique for establishing the total neutron rate of a highly-collimated monochromatic cold neutron beam was demonstrated using a method of an alpha-gamma counter. The method involves only the counting of measured rates and is independent of neutron cross sections, decay chain branching ratios, and neutron beam energy. For the measurement, a target of 10B-enriched boron carbide totally absorbed the neutrons in a monochromatic beam, and the rate of absorbed neutrons was determined by counting 478keV gamma rays from neutron capture on 10B with calibrated high-purity germanium detectors. A second measurement based on Bragg diffraction from a perfect silicon crystal was performed to determine the mean de Broglie wavelength of the beam to a precision of 0.024 %. With these measurements, the detection efficiency of a neutron monitor based on neutron absorption on 6Li was determined to an overall uncertainty of 0.058 %. We discuss the principle of the alpha-gamma method and present details of how the measurement was performed including the systematic effects. We also describe how this method may be used for applications in neutron dosimetry and metrology, fundamental neutron physics, and neutron cross section measurements.
△ Less
Submitted 8 January, 2018;
originally announced January 2018.
-
Determination of the Free Neutron Lifetime
Authors:
J. David Bowman,
L. J. Broussard,
S. M. Clayton,
M. S. Dewey,
N. Fomin,
K. B. Grammer,
G. L. Greene,
P. R. Huffman,
A. T. Holley,
G. L. Jones,
C. -Y. Liu,
M. Makela,
M. P. Mendenhall,
C. L. Morris,
J. Mulholland,
K. M. Nollett,
R. W. Pattie, Jr.,
S. Penttila,
M. Ramsey-Musolf,
D. J. Salvat,
A. Saunders,
S. J. Seestrom,
W. M. Snow,
A. Steyerl,
F. E. Wietfeldt
, et al. (2 additional authors not shown)
Abstract:
We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve bot…
▽ More
We present the status of current US experimental efforts to measure the lifetime of the free neutron by the "beam" and "bottle" methods. BBN nucleosynthesis models require accurate measurements with 1 second uncertainties, which are currently feasible. For tests of physics beyond the standard model, future efforts will need to achieve uncertainties well below 1 second. We outline paths achieve both.
△ Less
Submitted 20 October, 2014;
originally announced October 2014.
-
New measurement of the scattering cross section of slow neutrons on liquid parahydrogen from neutron transmission
Authors:
K. B. Grammer,
R. Alarcon,
L. Barrón-Palos,
D. Blyth,
J. D. Bowman,
J. Calarco,
C. Crawford,
K. Craycraft,
D. Evans,
N. Fomin,
J. Fry,
M. Gericke,
R. C. Gillis,
G. L. Greene,
J. Hamblen,
C. Hayes,
S. Kucuker,
R. Mahurin,
M. Maldonado-Velázquez,
E. Martin,
M. McCrea,
P. E. Mueller,
M. Musgrave,
H. Nann,
S. I. Penttilä
, et al. (3 additional authors not shown)
Abstract:
Liquid hydrogen is a dense Bose fluid whose equilibrium properties are both calculable from first principles using various theoretical approaches and of interest for the understanding of a wide range of questions in many body physics. Unfortunately, the pair correlation function $g(r)$ inferred from neutron scattering measurements of the differential cross section $dσ\over dΩ$ from different measu…
▽ More
Liquid hydrogen is a dense Bose fluid whose equilibrium properties are both calculable from first principles using various theoretical approaches and of interest for the understanding of a wide range of questions in many body physics. Unfortunately, the pair correlation function $g(r)$ inferred from neutron scattering measurements of the differential cross section $dσ\over dΩ$ from different measurements reported in the literature are inconsistent. We have measured the energy dependence of the total cross section and the scattering cross section for slow neutrons with energies between 0.43~meV and 16.1~meV on liquid hydrogen at 15.6~K (which is dominated by the parahydrogen component) using neutron transmission measurements on the hydrogen target of the NPDGamma collaboration at the Spallation Neutron Source at Oak Ridge National Laboratory. The relationship between the neutron transmission measurement we perform and the total cross section is unambiguous, and the energy range accesses length scales where the pair correlation function is rapidly varying. At 1~meV our measurement is a factor of 3 below the data from previous work. We present evidence that these previous measurements of the hydrogen cross section, which assumed that the equilibrium value for the ratio of orthohydrogen and parahydrogen has been reached in the target liquid, were in fact contaminated with an extra non-equilibrium component of orthohydrogen. Liquid parahydrogen is also a widely-used neutron moderator medium, and an accurate knowledge of its slow neutron cross section is essential for the design and optimization of intense slow neutron sources. We describe our measurements and compare them with previous work.
△ Less
Submitted 24 April, 2015; v1 submitted 8 October, 2014;
originally announced October 2014.
-
Fundamental Neutron Physics Beamline at the Spallation Neutron Source at ORNL
Authors:
N. Fomin,
G. L. Greene,
R. Allen,
V. Cianciolo,
C. Crawford,
T. Ito,
P. R. Huffman,
E. B. Iverson,
R. Mahurin,
W. M. Snow
Abstract:
We describe the Fundamental Neutron Physics Beamline (FnPB) facility located at the Spallation Neutron Source at Oak Ridge National Laboratory. The FnPB was designed for the conduct of experiments that investigate scientific issues in nuclear physics, particle physics, astrophysics and cosmology using a pulsed slow neutron beam. We present a detailed description of the design philosophy, beamline…
▽ More
We describe the Fundamental Neutron Physics Beamline (FnPB) facility located at the Spallation Neutron Source at Oak Ridge National Laboratory. The FnPB was designed for the conduct of experiments that investigate scientific issues in nuclear physics, particle physics, astrophysics and cosmology using a pulsed slow neutron beam. We present a detailed description of the design philosophy, beamline components, and measured fluxes of the polychromatic and monochromatic beams.
△ Less
Submitted 4 August, 2014;
originally announced August 2014.
-
Improved Determination of the Neutron Lifetime
Authors:
A. T. Yue,
M. S. Dewey,
D. M. Gilliam,
G. L. Greene,
A. B. Laptev,
J. S. Nico,
W. M. Snow,
F. E. Wietfeldt
Abstract:
The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of $τ_n = (886.3 \pm 1.2 [\textrm{stat}] \pm 3.2 [\textrm{syst}])$ s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged par…
▽ More
The most precise determination of the neutron lifetime using the beam method was completed in 2005 and reported a result of $τ_n = (886.3 \pm 1.2 [\textrm{stat}] \pm 3.2 [\textrm{syst}])$ s. The dominant uncertainties were attributed to the absolute determination of the fluence of the neutron beam (2.7 s). The fluence was measured with a neutron monitor that counted the neutron-induced charged particles from absorption in a thin, well-characterized 6Li deposit. The detection efficiency of the monitor was calculated from the areal density of the deposit, the detector solid angle, and the evaluated nuclear data file, ENDF/B-VI 6Li(n,t)4He thermal neutron cross section. In the current work, we have measured the detection efficiency of the same monitor used in the neutron lifetime measurement with a second, totally-absorbing neutron detector. This direct approach does not rely on the 6Li(n,t)4He cross section or any other nuclear data. The detection efficiency is consistent with the value used in 2005 but was measured with a precision of 0.057 %, which represents a five-fold improvement in the uncertainty. We have verified the temporal stability of the neutron monitor through ancillary measurements, allowing us to apply the measured neutron monitor efficiency to the lifetime result from the 2005 experiment. The updated lifetime is $τ_n = (887.7 \pm 1.2 [\textrm{stat}] \pm 1.9 [\textrm{syst}])$ s.
△ Less
Submitted 27 November, 2013; v1 submitted 10 September, 2013;
originally announced September 2013.
-
Discovering the New Standard Model: Fundamental Symmetries and Neutrinos
Authors:
V. Cianciolo,
A. B. Balantekin,
A. Bernstein,
V. Cirigliano,
M. D. Cooper,
D. J. Dean,
S. R. Elliott,
B. W. Filippone,
S. J. Freedman,
G. L. Greene,
K. M. Heeger,
D. W. Hertzog,
B. R. Holstein,
P. Huffman,
T. Ito,
K. Kumar,
Z. -T. Lu,
J. S. Nico,
G. D. Orebi Gann,
K. Paschke,
A. Piepke,
B. Plaster,
D. Pocanic,
A. W. P. Poon,
D. C. Radford
, et al. (6 additional authors not shown)
Abstract:
This White Paper describes recent progress and future opportunities in the area of fundamental symmetries and neutrinos.
This White Paper describes recent progress and future opportunities in the area of fundamental symmetries and neutrinos.
△ Less
Submitted 20 December, 2012;
originally announced December 2012.
-
Neutron Beta Decay Studies with Nab
Authors:
S. Baeßler,
R. Alarcon,
L. P. Alonzi,
S. Balascuta,
L. Barrón-Palos,
J. D. Bowman,
M. A. Bychkov,
J. Byrne,
J. R. Calarco,
T. Chupp,
T. V. Vianciolo,
C. Crawford,
E. Frlež,
M. T. Gericke,
F. Glück,
G. L. Greene,
R. K. Grzywacz,
V. Gudkov,
D. Harrison,
F. W. Hersman,
T. Ito,
M. Makela,
J. Martin,
P. L. McGaughey,
S. McGovern
, et al. (9 additional authors not shown)
Abstract:
Precision measurements in neutron beta decay serve to determine the coupling constants of beta decay and allow for several stringent tests of the standard model. This paper discusses the design and the expected performance of the Nab spectrometer.
Precision measurements in neutron beta decay serve to determine the coupling constants of beta decay and allow for several stringent tests of the standard model. This paper discusses the design and the expected performance of the Nab spectrometer.
△ Less
Submitted 20 September, 2012;
originally announced September 2012.
-
Study of the dependence of 198Au half-life on source geometry
Authors:
R. M. Lindstrom,
E. Fischbach,
J. B. Buncher,
G. L. Greene,
J. H. Jenkins,
D. E. Krause,
J. J. Mattes,
A. Yue
Abstract:
We report the results of an experiment to determine whether the half-life of \Au{198} depends on the shape of the source. This study was motivated by recent suggestions that nuclear decay rates may be affected by solar activity, perhaps arising from solar neutrinos. If this were the case then the $β$-decay rates, or half-lives, of a thin foil sample and a spherical sample of gold of the same mass…
▽ More
We report the results of an experiment to determine whether the half-life of \Au{198} depends on the shape of the source. This study was motivated by recent suggestions that nuclear decay rates may be affected by solar activity, perhaps arising from solar neutrinos. If this were the case then the $β$-decay rates, or half-lives, of a thin foil sample and a spherical sample of gold of the same mass and activity could be different. We find for \Au{198}, $(T_{1/2})_{\rm foil}/(T_{1/2})_{\rm sphere} = 0.999 \pm 0.002$, where $T_{1/2}$ is the mean half-life. The maximum neutrino flux at the sample in our experiments was several times greater than the flux of solar neutrinos at the surface of the Earth. We show that this increase in flux leads to a significant improvement in the limits that can be inferred on a possible solar contribution to nuclear decays.
△ Less
Submitted 25 June, 2010;
originally announced June 2010.
-
Nab: Measurement Principles, Apparatus and Uncertainties
Authors:
D. Pocanic,
R. Alarcon,
L. P. Alonzi,
S. Baessler,
S. Balascuta,
J. D. Bowman,
M. A. Bychkov,
J. Byrne,
J. R. Calarco,
V. Cianciolo,
C. Crawford,
E. Frlez,
M. T. Gericke,
G. L. Greene,
R. K. Grzywacz,
V. Gudkov,
F. W. Hersman,
A. Klein,
J. Martin,
S. A. Page,
A. Palladino,
S. I. Penttila,
K. P. Rykaczewski,
W. S. Wilburn,
A. R. Young
, et al. (1 additional authors not shown)
Abstract:
The Nab collaboration will perform a precise measurement of 'a', the electron-neutrino correlation parameter, and 'b', the Fierz interference term in neutron beta decay, in the Fundamental Neutron Physics Beamline at the SNS, using a novel electric/magnetic field spectrometer and detector design. The experiment is aiming at the 10^{-3} accuracy level in (Delta a)/a, and will provide an independe…
▽ More
The Nab collaboration will perform a precise measurement of 'a', the electron-neutrino correlation parameter, and 'b', the Fierz interference term in neutron beta decay, in the Fundamental Neutron Physics Beamline at the SNS, using a novel electric/magnetic field spectrometer and detector design. The experiment is aiming at the 10^{-3} accuracy level in (Delta a)/a, and will provide an independent measurement of lambda = G_A/G_V, the ratio of axial-vector to vector coupling constants of the nucleon. Nab also plans to perform the first ever measurement of 'b' in neutron decay, which will provide an independent limit on the tensor weak coupling.
△ Less
Submitted 1 October, 2008;
originally announced October 2008.
-
High-Efficiency Resonant RF Spin Rotator with Broad Phase Space Acceptance for Pulsed Polarized Cold Neutron Beams
Authors:
P. -N. Seo,
L. Barron-Palos,
J. D. Bowman,
T. E. Chupp,
C. Crawford,
M. Dabaghyan,
M. Dawkins,
S. J. Freedman,
T. Gentile,
M. T. Gericke,
R. C. Gillis,
G. L. Greene,
F. W. Hersman,
G. L. Jones,
M. Kandes,
S. Lamoreaux,
B. Lauss,
M. B. Leuschner,
R. Mahurin,
M. Mason,
J. Mei,
G. S. Mitchell,
H. Nann,
S. A. Page,
S. I. Penttila
, et al. (8 additional authors not shown)
Abstract:
We have developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to RF neutron spin flippers based on adiabatic fast passage. The spin rotator does not chang…
▽ More
We have developed a radio-frequency resonant spin rotator to reverse the neutron polarization in a 9.5 cm x 9.5 cm pulsed cold neutron beam with high efficiency over a broad cold neutron energy range. The effect of the spin reversal by the rotator on the neutron beam phase space is compared qualitatively to RF neutron spin flippers based on adiabatic fast passage. The spin rotator does not change the kinetic energy of the neutrons and leaves the neutron beam phase space unchanged to high precision. We discuss the design of the spin rotator and describe two types of transmission-based neutron spin-flip efficiency measurements where the neutron beam was both polarized and analyzed by optically-polarized 3He neutron spin filters. The efficiency of the spin rotator was measured to be 98.0+/-0.8% on resonance for neutron energies from 3.3 to 18.4 meV over the full phase space of the beam. As an example of the application of this device to an experiment we describe the integration of the RF spin rotator into an apparatus to search for the small parity-violating asymmetry A_gamma in polarized cold neutron capture on para-hydrogen by the NPDGamma collaboration at LANSCE.
△ Less
Submitted 15 October, 2007;
originally announced October 2007.
-
Upper Bounds on Parity Violating Gamma-Ray Asymmetries in Compound Nuclei from Polarized Cold Neutron Capture
Authors:
M. T. Gericke,
J. D. Bowman,
R. D. Carlini,
T. E. Chupp,
K. P. Coulter,
M. Dabaghyan,
M. Dawkins,
D. Desai,
S. J. Freedman,
T. R. Gentile,
R. C. Gillis,
G. L. Greene,
F. W. Hersman,
T. Ino,
G. L. Jones,
M. Kandes,
B. Lauss,
M. Leuschner,
W. R. Lozowski,
R. Mahurin,
M. Mason,
Y. Masuda,
G. S. Mitchell,
S. Muto,
H. Nann
, et al. (11 additional authors not shown)
Abstract:
Parity-odd asymmetries in the electromagnetic decays of compound nuclei can sometimes be amplified above values expected from simple dimensional estimates by the complexity of compound nuclear states. In this work we use a statistical approach to estimate the root mean square (RMS) of the distribution of expected parity-odd correlations $\vec{s_{n}} \cdot \vec{k_γ}$, where $\vec {s_{n}}$ is the…
▽ More
Parity-odd asymmetries in the electromagnetic decays of compound nuclei can sometimes be amplified above values expected from simple dimensional estimates by the complexity of compound nuclear states. In this work we use a statistical approach to estimate the root mean square (RMS) of the distribution of expected parity-odd correlations $\vec{s_{n}} \cdot \vec{k_γ}$, where $\vec {s_{n}}$ is the neutron spin and $\vec{k_γ}$ is the momentum of the gamma, in the integrated gamma spectrum from the capture of cold polarized neutrons on Al, Cu, and In and we present measurements of the asymmetries in these and other nuclei. Based on our calculations, large enhancements of asymmetries were not predicted for the studied nuclei and the statistical estimates are consistent with our measured upper bounds on the asymmetries.
△ Less
Submitted 3 August, 2006;
originally announced August 2006.
-
A Neutron Interferometric Method to Provide Improved Constraints on Non-Newtonian Gravity at the Nanometer Scale
Authors:
Geoffrey L. Greene,
Vladimir Gudkov
Abstract:
In recent years, an energetic experimental program has set quite stringent limits on a possible "non - 1/r^2" dependence on gravity at short length scales. This effort has been largely driven by the predictions of theories based on compactification of extra spatial dimensions. It is characteristic of many such theories that the strength and length scales of such anomalous gravity are not clearly…
▽ More
In recent years, an energetic experimental program has set quite stringent limits on a possible "non - 1/r^2" dependence on gravity at short length scales. This effort has been largely driven by the predictions of theories based on compactification of extra spatial dimensions. It is characteristic of many such theories that the strength and length scales of such anomalous gravity are not clearly determined from first principles. As a result, it is productive to extend the current limits the range and strength of such hypothetical interactions. As a heavy, neutral, and (almost) stable particle, the neutron provides an ideal probe for the study of such hypothetical interactions at very short range. In this work, we describe methods based on neutron interferometry which have the capability to provide improved sensitivity non-Newtonian forces down to length scales at and below an nanometer.
△ Less
Submitted 31 August, 2006;
originally announced August 2006.
-
Optimization of the Ballistic Guide Design for the SNS FNPB 8.9 A Neutron Line
Authors:
Takeyasu M. Ito,
Christopher B. Crawford,
Geoffrey L. Greene
Abstract:
The optimization of the ballistic guide design for the SNS Fundamental Neutron Physics Beamline 8.9 A line is described. With a careful tuning of the shape of the curve for the tapered section and the width of the straight section, this optimization resulted in more than 75% increase in the neutron flux exiting the 33 m long guide over a straight m=3.5 guide with the same length.
The optimization of the ballistic guide design for the SNS Fundamental Neutron Physics Beamline 8.9 A line is described. With a careful tuning of the shape of the curve for the tapered section and the width of the straight section, this optimization resulted in more than 75% increase in the neutron flux exiting the 33 m long guide over a straight m=3.5 guide with the same length.
△ Less
Submitted 27 April, 2006; v1 submitted 24 April, 2006;
originally announced April 2006.
-
Measurement of the Neutron Lifetime by Counting Trapped Protons in a Cold Neutron Beam
Authors:
J. S. Nico,
M. S. Dewey,
D. M. Gilliam,
F. E. Wietfeldt,
X. Fei,
W. M. Snow,
G. L. Greene,
J. Pauwels,
R. Eykens,
A. Lamberty,
J. Van Gestel,
R. D. Scott
Abstract:
A measurement of the neutron lifetime $τ_{n}$ performed by the absolute counting of in-beam neutrons and their decay protons has been completed. Protons confined in a quasi-Penning trap were accelerated onto a silicon detector held at a high potential and counted with nearly unit efficiency. The neutrons were counted by a device with an efficiency inversely proportional to neutron velocity, whic…
▽ More
A measurement of the neutron lifetime $τ_{n}$ performed by the absolute counting of in-beam neutrons and their decay protons has been completed. Protons confined in a quasi-Penning trap were accelerated onto a silicon detector held at a high potential and counted with nearly unit efficiency. The neutrons were counted by a device with an efficiency inversely proportional to neutron velocity, which cancels the dwell time of the neutron beam in the trap. The result is $τ_{n} = (886.6\pm1.2{\rm [stat]}\pm3.2{\rm [sys]})$ s, which is the most precise measurement of the lifetime using an in-beam method. The systematic uncertainty is dominated by neutron counting, in particular the mass of the deposit and the $^{6}$Li({\it{n,t}}) cross section. The measurement technique and apparatus, data analysis, and investigation of systematic uncertainties are discussed in detail.
△ Less
Submitted 19 November, 2004;
originally announced November 2004.
-
Measurement of the Neutron Lifetime Using a Proton Trap
Authors:
M. S. Dewey,
D. M. Gilliam,
J. S. Nico,
F. E. Wietfeldt,
X. Fei,
W. M. Snow,
G. L. Greene,
J. Pauwels,
R. Eykens,
A. Lamberty,
J. Van Gestel
Abstract:
We report a new measurement of the neutron decay lifetime by the absolute counting of in-beam neutrons and their decay protons. Protons were confined in a quasi-Penning trap and counted with a silicon detector. The neutron beam fluence was measured by capture in a thin 6LiF foil detector with known absolute efficiency. The combination of these simultaneous measurements gives the neutron lifetime…
▽ More
We report a new measurement of the neutron decay lifetime by the absolute counting of in-beam neutrons and their decay protons. Protons were confined in a quasi-Penning trap and counted with a silicon detector. The neutron beam fluence was measured by capture in a thin 6LiF foil detector with known absolute efficiency. The combination of these simultaneous measurements gives the neutron lifetime: tau_n = 886.8 +/- 1.2[stat] +/- 3.2[sys] seconds. The systematic uncertainty is dominated by uncertainties in the mass of the 6LiF deposit and the 6Li(n,t) cross section. This is the most precise measurement of the neutron lifetime to date using an in-beam method.
△ Less
Submitted 4 November, 2003;
originally announced November 2003.
-
Magnetic trapping of ultracold neutrons
Authors:
C. R. Brome,
J. S. Butterworth,
S. N. Dzhosyuk,
C. E. H. Mattoni,
D. N. McKinsey,
J. M. Doyle,
P. R. Huffman,
M. S. Dewey,
F. E. Wietfeldt,
R. Golub,
K. Habicht,
G. L. Greene,
S. K. Lamoreaux,
K. J. Coakley
Abstract:
Three-dimensional magnetic confinement of neutrons is reported. Neutrons are loaded into an Ioffe-type superconducting magnetic trap through inelastic scattering of cold neutrons with 4He. Scattered neutrons with sufficiently low energy and in the appropriate spin state are confined by the magnetic field until they decay. The electron resulting from neutron decay produces scintillations in the l…
▽ More
Three-dimensional magnetic confinement of neutrons is reported. Neutrons are loaded into an Ioffe-type superconducting magnetic trap through inelastic scattering of cold neutrons with 4He. Scattered neutrons with sufficiently low energy and in the appropriate spin state are confined by the magnetic field until they decay. The electron resulting from neutron decay produces scintillations in the liquid helium bath that results in a pulse of extreme ultraviolet light. This light is frequency downconverted to the visible and detected. Results are presented in which 500 +/- 155 neutrons are magnetically trapped in each loading cycle, consistent with theoretical predictions. The lifetime of the observed signal, 660 s +290/-170 s, is consistent with the neutron beta-decay lifetime.
△ Less
Submitted 13 March, 2001;
originally announced March 2001.
-
New Limit on the D Coefficient in Polarized Neutron Decay
Authors:
L. J. Lising,
S. R. Hwang,
J. M. Adams,
T. J. Bowles,
M. C. Browne,
T. E. Chupp,
K. P. Coulter,
M. S. Dewey,
S. J. Freedman,
B. K. Fujikawa,
A. Garcia,
G. L. Greene,
G. L. Jones,
H. P. Mumm,
J. S. Nico,
J. M. Richardson,
R. G. H. Robertson,
T. D. Steiger,
W. A. Teasdale,
A. K. Thompson,
E. G. Wasserman,
F. E. Wietfeldt,
R. C. Welsh,
J. F. Wilkerson
Abstract:
We describe an experiment that has set new limits on the time reversal invariance violating D coefficient in neutron beta-decay. The emiT experiment measured the angular correlation J . p_e x p_p using an octagonal symmetry that optimizes electron-proton coincidence rates. The result is D=[-0.6+/-1.2(stat)+/-0.5(syst)]x10^(-3). This improves constraints on the phase of g_A/g_V and limits contrib…
▽ More
We describe an experiment that has set new limits on the time reversal invariance violating D coefficient in neutron beta-decay. The emiT experiment measured the angular correlation J . p_e x p_p using an octagonal symmetry that optimizes electron-proton coincidence rates. The result is D=[-0.6+/-1.2(stat)+/-0.5(syst)]x10^(-3). This improves constraints on the phase of g_A/g_V and limits contributions to T violation due to leptoquarks. This paper presents details of the experiment, data analysis, and the investigation of systematic effects.
△ Less
Submitted 19 July, 2000; v1 submitted 1 June, 2000;
originally announced June 2000.
-
Magnetic Trapping of Neutrons
Authors:
P. R. Huffman,
C. R. Brome,
J. S. Butterworth,
K. J. Coakley,
M. S. Dewey,
S. N. Dzhosyuk,
R. Golub,
G. L. Greene,
K. Habicht,
S. K. Lamoreaux,
C. E. H. Mattoni,
D. N. McKinsey,
F. E. Wietfeldt,
J. M. Doyle
Abstract:
Accurate measurement of the lifetime of the neutron (which is unstable to beta decay) is important for understanding the weak nuclear force and the creation of matter during the Big Bang. Previous measurements of the neutron lifetime have mainly been limited by certain systematic errors; however, these could in principle be avoided by performing measurements on neutrons stored in a magnetic trap…
▽ More
Accurate measurement of the lifetime of the neutron (which is unstable to beta decay) is important for understanding the weak nuclear force and the creation of matter during the Big Bang. Previous measurements of the neutron lifetime have mainly been limited by certain systematic errors; however, these could in principle be avoided by performing measurements on neutrons stored in a magnetic trap. Neutral and charged particle traps are widely used tool for studying both composite and elementary particles, because they allow long interaction times and isolation from perturbing environments. Here we report the magnetic trapping of neutrons. The trapping region is filled with superfluid 4-He, which is used to load neutrons into the trap and as a scintillator to detect their decay. Neutrons have a lifetime in the trap of 750 +330/-200 seconds, mainly limited by their beta decay rather than trap losses. Our experiment verifies theoretical predictions regarding the loading process and magnetic trapping of neutrons. Further refinement of this method should lead to improved precision in the neutron lifetime measurement.
△ Less
Submitted 7 January, 2000;
originally announced January 2000.