-
Accelerated electron thermometer: observation of 1D Planck radiation
Authors:
Morgan H. Lynch,
Evgenii Ievlev,
Michael R. R. Good
Abstract:
We report on the observation of thermal photons from an accelerated electron via examination of radiative beta decay of free neutrons measured by the RDK II collaboration. The emitted photon spectrum is shown to corroborate a thermal distribution consistent with the dynamical Casimir effect. Supported by a robust chi-squared statistic, we find the photons reside in a one-dimensional Planck spectru…
▽ More
We report on the observation of thermal photons from an accelerated electron via examination of radiative beta decay of free neutrons measured by the RDK II collaboration. The emitted photon spectrum is shown to corroborate a thermal distribution consistent with the dynamical Casimir effect. Supported by a robust chi-squared statistic, we find the photons reside in a one-dimensional Planck spectrum with a temperature predicted by the moving mirror model.
△ Less
Submitted 27 December, 2023; v1 submitted 27 November, 2022;
originally announced November 2022.
-
Improvements to TITAN's Mass Measurement and Decay Spectroscopy Capabilities
Authors:
D. Lascar,
A. A. Kwiatkowski,
M. Alanssari,
U. Chowdhury,
J. Even,
A. Finlay,
A. T. Gallant,
M. Good,
R. Klawitter,
B. Kootte,
T. Li K. G. Leach,
A. Lennarz,
E. Leistenschneider,
A. J. Mayer,
B. E. Schultz,
R. Schupp,
D. A. Short,
C. Andreoiu,
J. Dilling,
G. Gwinner
Abstract:
The study of nuclei farther from the valley of $β$-stability goes hand-in-hand with shorter-lived nuclei produced in smaller abundances than their more stable counterparts. The measurement, to high precision, of nuclear masses therefore requires innovations in technique in order to keep up. TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) facility deploys three ion traps, with a fourth in…
▽ More
The study of nuclei farther from the valley of $β$-stability goes hand-in-hand with shorter-lived nuclei produced in smaller abundances than their more stable counterparts. The measurement, to high precision, of nuclear masses therefore requires innovations in technique in order to keep up. TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN) facility deploys three ion traps, with a fourth in the commissioning phase, to perform and support Penning trap mass spectrometry and in-trap decay spectroscopy on some of the shortest-lived nuclei ever studied. We report on recent advances and updates to the TITAN facility since the 2012 EMIS Conference.
TITAN's charge breeding capabilities have been improved and in-trap decay spectroscopy can be performed in TITAN's electron beam ion trap (EBIT). Higher charge states can improve the precision of mass measurements, reduce the beam-time requirements for a given measurement, improve beam purity and opens the door to access, via in-trap decay and recapture, isotopes not available from the ISOL method. This was recently demonstrated during TITAN's mass measurement of $^{30}$Al. The EBIT's decay spectroscopy setup was commissioned with a successful branching ratio and half-life measurement of $^{124}$Cs.
Charge breeding in the EBIT increases the energy spread of the ion bunch sent to the Penning trap for mass measurement so a new Cooler Penning Trap (CPET), which aims to cool highly charge ions with an electron plasma, is undergoing online commissioning. Already, CPET has demonstrated the trapping and self-cooling of a room-temperature electron plasma which was stored for several minutes. A new detector has been installed inside the CPET magnetic field which will allow for in-magnet charged particle detection.
△ Less
Submitted 2 August, 2017; v1 submitted 26 August, 2015;
originally announced August 2015.
-
Sensitivity Increases for the TITAN Decay Spectroscopy Program
Authors:
K. G. Leach,
A. Lennarz,
A. Grossheim,
C. Andreoiu,
J. Dilling,
D. Frekers,
M. Good,
S. Seeraji
Abstract:
The TITAN facility at TRIUMF has recently initiated a program of performing decay spectroscopy measurements in an electron-beam ion-trap (EBIT). The unique environment of the EBIT provides backing-free storage of the radioactive ions, while guiding charged decay particles from the trap centre via the strong magnetic field. This measurement technique is able to provide a significant increase in det…
▽ More
The TITAN facility at TRIUMF has recently initiated a program of performing decay spectroscopy measurements in an electron-beam ion-trap (EBIT). The unique environment of the EBIT provides backing-free storage of the radioactive ions, while guiding charged decay particles from the trap centre via the strong magnetic field. This measurement technique is able to provide a significant increase in detection sensitivity for photons which result from radioactive decay. A brief overview of this device is presented, along with methods of improving the signal-to-background ratio for photon detection by reducing Compton scattered events, and eliminating vibrational noise.
△ Less
Submitted 30 October, 2014;
originally announced November 2014.
-
The TITAN in-trap decay spectroscopy facility at TRIUMF
Authors:
K. G. Leach,
A. Grossheim,
A. Lennarz,
T. Brunner,
J. R. Crespo López-Urrutia,
A. T. Gallant,
M. Good,
R. Klawitter,
A. A. Kwiatkowski,
T. Ma,
T. D. Macdonald,
S. Seeraji,
M. C. Simon,
C. Andreoiu,
J. Dilling,
D. Frekers
Abstract:
This article presents an upgraded in-trap decay spectroscopy apparatus which has been developed and constructed for use with TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This device consists of an open-access electron-beam ion-trap (EBIT), which is surrounded radially by seven low-energy planar Si(Li) detectors. The environment of the EBIT allows for the detection of low-energy photon…
▽ More
This article presents an upgraded in-trap decay spectroscopy apparatus which has been developed and constructed for use with TRIUMF's Ion Trap for Atomic and Nuclear science (TITAN). This device consists of an open-access electron-beam ion-trap (EBIT), which is surrounded radially by seven low-energy planar Si(Li) detectors. The environment of the EBIT allows for the detection of low-energy photons by providing backing-free storage of the radioactive ions, while guiding charged decay particles away from the trap centre via the strong (up to 6 T) magnetic field. In addition to excellent ion confinement and storage, the EBIT also provides a venue for performing decay spectroscopy on highly-charged radioactive ions. Recent technical advancements have been able to provide a significant increase in sensitivity for low-energy photon detection, towards the goal of measuring weak electron-capture branching ratios of the intermediate nuclei in the two-neutrino double beta ($2νββ$) decay process. The design, development, and commissioning of this apparatus are presented together with the main physics objectives. The future of the device and experimental technique are discussed.
△ Less
Submitted 21 November, 2014; v1 submitted 28 May, 2014;
originally announced May 2014.
-
Verifying the accuracy of the TITAN Penning-trap mass spectrometer
Authors:
M. Brodeur,
V. L. Ryjkov,
T. Brunner,
S. Ettenauer,
A. T. Gallant,
V. V. Simon,
M. J. Smith,
A. Lapierre,
R. Ringle,
P. Delheij,
M. Good,
D. Lunney,
J. Dilling
Abstract:
TITAN (TRIUMF's Ion Traps for Atomic and Nuclear science) is an online facility designed to carry out high-precision mass measurements on singly and highly charged radioactive ions. The TITAN Penning trap has been built and optimized in order to perform such measurements with an accuracy in the sub ppb-range. A detailed characterization of the TITAN Penning trap is presented and a new compensation…
▽ More
TITAN (TRIUMF's Ion Traps for Atomic and Nuclear science) is an online facility designed to carry out high-precision mass measurements on singly and highly charged radioactive ions. The TITAN Penning trap has been built and optimized in order to perform such measurements with an accuracy in the sub ppb-range. A detailed characterization of the TITAN Penning trap is presented and a new compensation method is derived and demonstrated, verifying the performance in the range of sub-ppb.
△ Less
Submitted 4 November, 2011; v1 submitted 13 October, 2011;
originally announced October 2011.
-
A large Bradbury Nielsen ion gate with flexible wire spacing based on photo-etched stainless steel grids and its characterization applying symmetric and asymmetric potentials
Authors:
T. Brunner,
A. R. Mueller,
K. O'Sullivan,
M. C. Simon,
M. Kossick,
S. Ettenauer,
A. T. Gallant,
E. Mané,
D. Bishop,
M. Good,
G. Gratta,
J. Dilling
Abstract:
Bradbury Nielsen gates are well known devices used to switch ion beams and are typically applied in mass or mobility spectrometers for separating beam constituents by their different flight or drift times. A Bradbury Nielsen gate consists of two interleaved sets of electrodes. If two voltages of the same amplitude but opposite polarity are applied the gate is closed, and for identical (zero) poten…
▽ More
Bradbury Nielsen gates are well known devices used to switch ion beams and are typically applied in mass or mobility spectrometers for separating beam constituents by their different flight or drift times. A Bradbury Nielsen gate consists of two interleaved sets of electrodes. If two voltages of the same amplitude but opposite polarity are applied the gate is closed, and for identical (zero) potential the gate is open. Whereas former realizations of the device employ actual wires resulting in difficulties with winding, fixing and tensioning them, our approach is to use two grids photo-etched from a metallic foil. This design allows for simplified construction of gates covering large beam sizes up to at least 900\,mm$^2$ with variable wire spacing down to 250\,\textmu m. By changing the grids the wire spacing can be varied easily. A gate of this design was installed and systematically tested at TRIUMF's ion trap facility, TITAN, for use with radioactive beams to separate ions with different mass-to-charge ratios by their time-of-flight.
△ Less
Submitted 14 September, 2011; v1 submitted 20 July, 2011;
originally announced July 2011.
-
TITAN's Digital RFQ Ion Beam Cooler and Buncher, Operation and Performance
Authors:
T. Brunner,
M. J. Smith,
M. Brodeur,
S. Ettenauer,
A. T. Gallant,
V. V. Simon,
A. Chaudhuri A. Lapierre,
E. Mané,
R. Ringle,
M. C. Simon,
J. A. Vaz,
P. Delheij,
M. Good,
M. R. Pearson,
J. Dilling
Abstract:
We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching radioactive ion beams delivered from ISAC-TRIUMF. This is the first such device to be driven digitally, i.e., using a high voltage (…
▽ More
We present a description of the Radio Frequency Quadrupole (RFQ) ion trap built as part of the TITAN facility. It consists of a gas-filled, segmented, linear Paul trap and is the first stage of the TITAN setup with the purpose of cooling and bunching radioactive ion beams delivered from ISAC-TRIUMF. This is the first such device to be driven digitally, i.e., using a high voltage ($V_{pp} = \rm{400 \, V}$), wide bandwidth ($0.2 < f < 1.2 \, \rm{MHz}$) square-wave as compared to the typical sinusoidal wave form. Results from the commissioning of the device as well as systematic studies with stable and radioactive ions are presented including efficiency measurements with stable $^{133}$Cs and radioactive $^{124, 126}$Cs. A novel and unique mode of operation of this device is also demonstrated where the cooled ion bunches are extracted in reverse mode, i.e., in the same direction as previously injected.
△ Less
Submitted 7 February, 2012; v1 submitted 12 July, 2011;
originally announced July 2011.