-
Light-yield response of liquid scintillators using 2--6 MeV tagged neutrons
Authors:
N. Mauritzson,
K. G. Fissum,
J. R. M. Annand,
H. Perrey,
R. Al Jebali,
A. Backis,
R. Hall-Wilton,
K. Kanaki,
V. Maulerova-Subert,
F. Messi,
R. J. W. Frost,
E. Rofors,
J. Scherzinger
Abstract:
Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study the scintillation light-yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event-by-event waveform digitization. Energy calibration was performed using a GEANT model to locate the edge p…
▽ More
Knowledge of the neutron light-yield response is crucial to the understanding of scintillator-based neutron detectors. In this work, neutrons from 2--6 MeV have been used to study the scintillation light-yield response of the liquid scintillators NE 213A, EJ 305, EJ 331 and EJ 321P using event-by-event waveform digitization. Energy calibration was performed using a GEANT model to locate the edge positions of the Compton distributions produced by gamma-ray sources. The simulated light yield for neutrons from a PuBe source was compared to measured recoil proton distributions, where neutron energy was selected by time-of-flight. This resulted in an energy-dependent Birks parametrization to characterize the non-linear response to the lower energy neutrons. The NE 213A and EJ 305 results agree very well with existing data and are reproduced nicely by the simulation. New results for EJ 331 and EJ 321P, where the simulation also reproduces the data well, are presented.
△ Less
Submitted 24 November, 2023; v1 submitted 31 October, 2023;
originally announced November 2023.
-
Technique for the measurement of intrinsic pulse-shape discrimination for organic scintillators using tagged neutrons
Authors:
N. Mauritzson,
K. G. Fissum,
J. R. M. Annand,
H. Perrey,
R. J. W. Frost,
R. Al Jebali,
A. Backis,
R. Hall-Wilton,
K. Kanaki,
V. Maulerova-Subert,
C. Maurer,
F. Messi,
E. Rofors
Abstract:
Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis. Gamma-ray sources and a Geant4-based simulation were used to calibrate the scintillation-light yield. The difference in pulse shape for the neutron and gamma-ray even…
▽ More
Fast-neutron/gamma-ray pulse-shape discrimination has been performed for the organic liquid scintillators NE 213A and EJ 305 using a time-of-flight based neutron-tagging technique and waveform digitization on an event-by-event basis. Gamma-ray sources and a Geant4-based simulation were used to calibrate the scintillation-light yield. The difference in pulse shape for the neutron and gamma-ray events was analysed by integrating selected portions of the digitized waveform to produce a figure-of-merit for neutron/gamma-ray separation. This figure-of-merit has been mapped as a function of detector threshold and also of neutron energy determined from time-of-flight. It shows clearly that the well-established pulse-shape discrimination capabilities of NE 213A are superior to those of EJ 305. The extra information provided by the neutron-tagging technique has resulted in a far more detailed assessment of the pulse-shape discrimination capabilities of these organic scintillators.
△ Less
Submitted 2 June, 2022;
originally announced June 2022.
-
Geant4-based calibration of an organic liquid scintillator
Authors:
N. Mauritzson,
K. G. Fissum,
H. Perrey,
J. R. M. Annand,
R. J. W. Frost,
R. Hall-Wilton,
R. Al Jebali,
K. Kanaki,
V. Maulerova,
F. Messi,
E. Rofors
Abstract:
A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using both monoenergetic and polyenergetic gamma-ray sources. Scintillation light was detected in a photomultiplier tube, and the corresponding pulses were subjected to waveform digitization on an event-by-event basis. The resulting Compton edges have been analyzed using a Geant4 simulation of the detec…
▽ More
A light-yield calibration of an NE 213A organic liquid scintillator detector has been performed using both monoenergetic and polyenergetic gamma-ray sources. Scintillation light was detected in a photomultiplier tube, and the corresponding pulses were subjected to waveform digitization on an event-by-event basis. The resulting Compton edges have been analyzed using a Geant4 simulation of the detector which models both the interactions of the ionizing radiation as well as the transport of scintillation photons. The simulation is calibrated and also compared to well-established prescriptions used to determine the Compton edges, resulting ultimately in light-yield calibration functions. In the process, the simulation-based method produced information on the gain and intrinsic pulse-height resolution of the detector. It also facilitated a previously inaccessible understanding of the systematic uncertainties associated with the calibration of the scintillation-light yield. The simulation-based method was also compared to well-established numerical prescriptions for locating the Compton edges. Ultimately, the simulation predicted as much as 17% lower light-yield calibrations than the prescriptions. These calibrations indicate that approximately 35% of the scintillation light associated with a given gamma-ray reaches the photocathode. It is remarkable how well two 50 year old prescriptions for calibrating scintillation-light yield in organic scintillators have stood the test of time.
△ Less
Submitted 22 October, 2021; v1 submitted 24 September, 2021;
originally announced September 2021.
-
Response of a Li-glass/multi-anode photomultiplier detector to focused proton and deuteron beams
Authors:
E. Rofors,
J. Pallon,
R. Al Jebali,
J. R. M. Annand,
L. Boyd,
M. J. Christensen,
U. Clemens,
S. Desert,
M. Elfman,
R. Engels,
K. G. Fissum,
H. Frielinghaus,
R. Frost,
S. Gardner,
C. Gheorghe,
R. Hall-Wilton,
S. Jaksch,
K. Kanaki,
G. Kemmerling,
P. Kristiansson,
K. Livingston,
V. Maulerova,
N. Mauritzson,
R. Montgomery,
H. Perrey
, et al. (4 additional authors not shown)
Abstract:
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel…
▽ More
The response of a position-sensitive Li-glass based scintillation detector to focused beams of 2.5 MeV protons and deuterons has been investigated. The beams were scanned across the detector in 0.5 mm horizontal and vertical steps perpendicular to the beams. Scintillation light was registered using an 8 by 8 pixel multi-anode photomultiplier tube. The signal amplitudes were recorded for each pixel on an event-by-event basis. Several pixels generally registered considerable signals at each beam location. The number of pixels above set thresholds were investigated, with the optimization of the single-hit efficiency over the largest possible area as the goal. For both beams, at a threshold of ~50% of the mean of the full-deposition peak, ~80% of the events were registered in a single pixel, resulting in an effective position resolution of ~5 mm in X and Y.
△ Less
Submitted 18 May, 2020;
originally announced May 2020.